• Title/Summary/Keyword: Thyristor valve

Search Result 30, Processing Time 0.032 seconds

Design of Characteristics Test Equipment for a Large Capacity Thyristor (대용량 사이리스터 특성평가 장비의 설계 및 제작)

  • Seo Kil-Soo;Kim Hyoung-Woo;Kim Ki-Hyun;Kim Nam-Kun;Kim Eun-Dong
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.54 no.12
    • /
    • pp.567-572
    • /
    • 2005
  • Recently, application area of the thyristor is extends to power conversion systems, such as HVDC, BTB, SVC and FACTS. Therefore, reliability diagnostic technique on thyristor is needed to obtain stability and maintenance of power conversion systems. To measure the characteristics of the thyristor, test equipments which based on IEC 747-6 and KS C 7023 standard are needed. In this paper, we presents the design and manufacture of the test equipments for 6.5kV/4.2kA thyristor which used in thyristor valve of HVDC conversion systems by using test standard. Voltage, current, dv/dt and turn-off time test equipments were designed and manufactured. Each systems were made separately, but unity operation can possible.

Improved Current Source using Full-Bridge Converter Type for Thyristor Valve Test of HVDC System (HVDC 시스템의 SCR 사이리스터 밸브 시험을 위한 Full-Bridge Converter 방식의 개선된 전류원 회로)

  • Jung, Jae-Hun;Cho, Han-Je;Goo, Beob-Jin;Nho, Eui-Cheol;Chung, Yong-Ho;Baek, Seung-Taek
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.20 no.4
    • /
    • pp.363-368
    • /
    • 2015
  • This paper deals with an improved current source using full-bridge converter type for thyristor valve test of HVDC system. The conventional high-current and low-voltage source of synthetic test circuit requires additional auxiliary power supply to provide the reverse voltage for the auxiliary thyristor valve during turn-off process. The proposed circuit diagram to provide the reverse voltage is extremely simple because no additional component is required. The reverse voltage can be obtained from the input DC voltage of the high-current and low-voltage power supply. The operation principle and design method of the proposed system are described. Simulation and experimental results in scaled down STC of 200 V, 30 A demonstrate the validity of the proposed scheme.

The Study of Thyristor Valve Water Cooling Control Systems (대전력 반도체 정류기 수냉식 냉각 설비 냉매 온도 제어시스템에 관한 연구)

  • 임익헌;류호선
    • Proceedings of the KIPE Conference
    • /
    • 1999.07a
    • /
    • pp.230-233
    • /
    • 1999
  • The design and implementation of thyristor water cooling control systems in considered in this pape Coolant water is pumped through the thyristor heat sinks where heat is transferred from the thyristo to the water. This water is then pumped through outdoor air-to-water heat exchangers where heat I transferred to the outside air. Since the water must be pure, it is filtered and de-ionized. Also the water temperature must be below dew-point temperature. Redundant pumps, outdoor heat exchangers, power supply system, controller monitoring system are provided for system reliability and availability.

  • PDF

Study on the fault current test of HVDC thyristor valve (전류형 HVDC Valve의 단락시험에 대한 연구)

  • Lee, Jin-Hee;Kwon, Jun-Bum;Baek, Seung-Taek;Yun, Ji-Ho;Lee, Wook-Hwa;Chung, Yong-Ho
    • Proceedings of the KIPE Conference
    • /
    • 2013.11a
    • /
    • pp.81-82
    • /
    • 2013
  • HVDC 시스템은 초고압 직류 송전 시스템으로써, AC를 DC로 변환하여 장거리 송전에 유리한 시스템이다. 현재 대륙간 송전 및 주파수 변환을 위한 BtB Topology에 많이 응용되고 있다. HVDC 시스템의 장점은 일정 송전거리 이상이 되면, DC가 AC에 비하여 손실율이 적고 유리한 장점이 있다. 해당 HVDC Valve는 전력을 AC-DC-AC로 변환하려면, HVDC Valve(Module)이라고 불리는 전력 변환 장치가 필수적이다. 해당 Valve를 현장에 설치하기 전에 IEC 60700-1 또는 CIGRE 같은 국제 표준 규격에 맞추어 Type Test를 진행 후에 통과 시 현장에 설치되어야 한다. 해당 Type Test는 크게 2가지로 분류되며, 절연 성능을 시험하기위한 Dielectric Test 그리고, 실제 Thyristor Valve의 동작을 가혹 한 조건에서 시험하기위한 Operational Test가 필요하다. 본 논문은 IEC 규격 (IEC 60700-1)에 의거 사이리스터 밸브에 대한 Operational Test 중 단락시험방법과 시험내용을 기술하고, 시험결과로 검증한다.

  • PDF

Study on Dielectric Tests for SVC Thyristor Valves (SVC용 사이리스터 밸브 절연 시험에 대한 고찰)

  • Yun, Ji-Ho;Cho, Han-Je;Hong, Gi-Yong;Jung, Teag-Sun;Lee, Jin-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.355-356
    • /
    • 2015
  • LS산전은 전기적 트리거 방식의 사이리스터(electrical-triggered thyristor)를 이용한 Static Var Compensator(이하 SVC) 개발에 성공했다. 개발된 SVC는 ${\pm}100MVar$ 급으로 과전압에 대한 자체 보호 기능을 내장하고 있으며 LS산전표준과 IEC 규격에 따라 성능이 검증되었다. 본 논문에서는 SVC 시스템의 핵심 구성품인 Thyristor Controlled Reactor (이하 TCR) / Thyristor Switched Capacitor (이하 TSC) Valve 개발 시험의 일부로 진행한 절연 시험에 대해 상세히 소개하고자 한다.

  • PDF

The Analysis of Electrical Conduction and Corrosion Phenomena in HVDC Cooling System and the Optimized Design of the Heat Sink of the Semiconductor Devices (HVDC 냉각시스템의 전기전도현상 및 부식현상 기술 분석과 스위칭 소자의 방열판 최적 설계 검토)

  • Kim, Chan-Ki;Park, Chang-Hwan;Kim, Jang-Mok
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.22 no.6
    • /
    • pp.484-495
    • /
    • 2017
  • In HVDC thyristor valves, more than 95% of heat loss occurs in snubber resistors and valve reactors. In order to dissipate the heat from the valves and to suppress the electrolytic current, water with a high heat capacity and a low conductivity of less than 0.2 uS/cm must be used as a refrigerant of the heat sink. The cooling parts must also be arranged to reduce the electrolytic current, whereas the pipe that supplies water to the thyristor heat sink must have the same electric potential as the valve. Corrosion is mainly caused by electrochemical reactions and the influence of water quality and leakage current. This paper identifies the refrigerants involved in the ionization, electrical conductivity, and corrosion in HVDC thyristor valves. A method for preventing corrosion is then introduced. The design of the heat sink with an excellent heat radiation is also analyzed in detail.

Reduction Method of Radio Interference in HVDC Converter System (HVDC 컨버터 시스템에서 라디오 장해에 대한 대책)

  • Kim, Chan-Ki;Choi, Soon-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.6
    • /
    • pp.833-837
    • /
    • 2012
  • In HVDC System, the rapid voltage breakdown between anodes and cathodes during valve firing causes radio interference in HVDC converter station. These voltage breakdown causes steep current pulse and inject current in system. As a result, harmonic frequencies are generated from valve, switchyard. In this paper, theoretical background of radio interference in HVDC converter is discussed and its reduction method for radio interference is proposed.

A study of the dielectric test of thyristor valve for HVDC conversion

  • Jung, Teag-sun;Kwon, Jun-bum;Baek, Seung-taek;Yun, Ji-ho;Jung, Yong-ho
    • Proceedings of the KIPE Conference
    • /
    • 2012.07a
    • /
    • pp.572-573
    • /
    • 2012
  • 전력 수요 급증과 전력 기술 발전으로 인해, 오늘날 HVDC 기술이 널리 사용되고 있다. 또한 지구 온난화, 녹색 에너지 개발, 스마트 그리드 사업 등으로 인해 세계적으로 HVDC 수요가 급증하고 있는 추세이다. 국내에서도 제주-해남간 HVDC 1호기가 이미 운영 중에 있으며, 제주-진도간 HVDC 2호기가 2012년 완공을 목표로 현재 설치 중에 있다. 2009년 HVDC 사업에 진출한 LS산전은 지난해 변환용 변압기를 국내 최초로 생산한데 이어, HVDC 핵심 요소인 싸이리스터 밸브(thyristor valve)도 개발 완료 하였다. 싸이리스터 밸브는 HVDC 시스템의 변환설비 중 심장 역할을 하는 핵심적인 설비로 교류를 직류로, 또는 직류를 교류로 변환시켜 교류 계통에 전력을 공급하는 장치로, 사용하기 전에 성능을 충분히 검증해야 한다. LS산전은 독자적으로 개발한 싸이리스터 밸브를 IEC 규격에 따라 엄격히 시험하여 성능을 입증하였다. 본 논문에서는 개발 시험의 일부로 수행한 싸이리스터 밸브에 대한 절연 시험(dielectric test)를 소개하고자 한다.

  • PDF

Synthetic Test Circuit protection design for HVDC Valve Operational test (HVDC Valve Operational Test를 위한 합성시험설비 보호 설계)

  • Kim, Young Woo;Baek, Seung Taek;Lee, Uk Hwa;Chung, Young Ho
    • Proceedings of the KIPE Conference
    • /
    • 2013.07a
    • /
    • pp.516-517
    • /
    • 2013
  • 신재생 에너지의 비중 확대와 보급이 늘어남에 따라, 국가 간, 도시 간의 송전이 중요한 이슈로 대두 되고 있다. 위와 같은 요구 조건을 만족시키기 위해서 초고압 직류 송전의 개발이 필요하다. 초고압 직류송전(HVDC)에는 전류형과 전압형으로 나뉘는데. 각 HVDC에서 사용되는 Valve는 실제 운전 전에 여러 가지 방법으로 검증이 필요하다. 합성 시험회로 설비(Synthetic Test Circuit = 이하 STC)는 전류형 HVDC에서 사용되는 주요 전력변환 장치로, Thyristor Valve의 동작을 실제 동작 조건에 맞추어 동작을 시켜, 동작의 신뢰성을 검증하는 시험 설비이다. 본 논문에서는 전류형 HVDC Valve의 Operational Test를 위한 STC의 보호기능에 대해 기술하고 있다. 합성시험회로는 2상 초퍼와 6 펄스 사이리스터 컨버터를 사용하였고 설계된 보호기능은 PSCAD를 사용하여 검증하였다. HVDC Valve Operational Test시 합성시험회로 내에서 발생할 수 있는 사고 상황을 상정하고 그에 따른 보호 기능을 모의하였다.

  • PDF