• Title/Summary/Keyword: Through Transmission

Search Result 4,635, Processing Time 0.027 seconds

Dust collector strainer and carbon filter pressure permeation analysis (흡연집진기 내 스트레이너 및 카본필터 압력투과 해석)

  • Lee, Chi-Woo
    • Journal of Power System Engineering
    • /
    • v.19 no.4
    • /
    • pp.5-10
    • /
    • 2015
  • Dust collector is one of the most widely used equipment among the method of separating particles, it filters exhaust gas having various kinds of dusts through several filters installed on parallel. This research investigated the moving characteristic of Honeycomb-type carbon filter in pressure drop of smoking collector's ventilation system. It also compared pressure transmission coefficient through pressure drop according to flow velocity change.

Study on the Biomedical Signal Processing System (신호처리 알고리즘을 적용한 생체신호처리 시스템에 관한 연구)

  • 박차훈;김태선
    • Proceedings of the Korea Society for Industrial Systems Conference
    • /
    • 2001.05a
    • /
    • pp.252-255
    • /
    • 2001
  • The purpose of this study is to realize the real time monitoring ECG telemetry system applied by the telemetry unit, in which transmission is made through the electronic wave and reception is made through the light, and by the wavelet algorithm as well. A light receiver via existing telemetry unit which is based on baseband, the reception length was 50cm, but when the frequency modulation is used, the reception length is extended to 3m. In addition to this, we have found that the full-duplex method of transmission became available by using dual-mechanism.

  • PDF

A study on the Railway signal Control Using Radio Frequency (무선통신을 이용한 철도신호제어에 관한 연구)

  • 강민수;김윤집;이정석;이동선;유광균;이기서
    • Proceedings of the KSR Conference
    • /
    • 2001.05a
    • /
    • pp.327-332
    • /
    • 2001
  • This paper proposes the system to describe the data transmission methods using the simply frequency transmission methods between a railway track and the train. This system can control the railway signals through the ABS or ATS system located in the train and stations, having the frequency about 433.92 MHz. It shows the advanced system to send a lot of data through the microprocessor installed in a transmitter and transmitter-receiver at the train and railway.

  • PDF

A Study on the TCM Transmission of Voice/Nonvoice Signals Modulated by DPSK through the 2-Wire Subscriber Loop (2-선식가입자 선로를 통해 DPSK로 변조된 음성 및 비음성 신호의 시간압축다중화 전송에 관한 연구)

  • 장청룡;강창언
    • Proceedings of the Korean Institute of Communication Sciences Conference
    • /
    • 1986.04a
    • /
    • pp.107-112
    • /
    • 1986
  • This paper presents one method to resolve the end-to-end digital connectivity through 2-wire subscriber loop. This system which consists of the subscriber`s device and the line termination device makes use of the advantages of time compressed multiplexing and modified DPSK. Experimental results show that the transmission range of the lab test covers 2km and that of the field test covers 1.5km.

  • PDF

A Novel Non-contact Measurement Method for the Detection of Current Flowing Through Concealed Conductors

  • Yang, Fan;Liu, Kai;Zhu, Liwei;Hu, Jiayuan;Wang, Xiaoyu;Shen, Xiaoming;Luo, Hanwu;Ammad, Jadoon
    • Journal of Magnetics
    • /
    • v.22 no.1
    • /
    • pp.43-48
    • /
    • 2017
  • In order to detect the current flowing through concealed conductor, this paper proposes a new method based on derivative method. Firstly, this paper analyzes the main peak characteristic of the derivative function of magnetic field generated by a current-carrying conductor, and a relationship between the current flowing through the conductor and the main peak of the derivative function is obtained and applied to calculate the current. Then, the method is applied to detect the conductor current flowing through grounding grids of substations. Finally, the numerical experimental and field experiment verified the feasibility and accuracy of the method, and the computing results show that the method can effectively measure the conductor current of grounding grids with low error, and the error is within 5 %.

Near-infrared Laser Energy Transmission through Teeth with Crack Lines: An In-vitro Study

  • Sapra, Ashita;Darbar, Arun;George, Roy
    • Medical Lasers
    • /
    • v.10 no.4
    • /
    • pp.214-219
    • /
    • 2021
  • Background and Objectives To evaluate the difference in near-infrared (810 nm) laser energy transmission through teeth with and without cracks. Materials and Methods Extracted teeth were sectioned and examined visually for the presence of cracks with the aid of photographs and a trans-illuminator. Fourteen sections, each with cracks (Group A) and no cracks (Group B) were identified and placed 15 mm from the tip of a 300 micron fiber, prior to activation with an 810 nm diode laser (0.1W, 50 ms interval,100 ms duration). A power meter positioned behind the tooth recorded the average energy that was transmitted through the samples. Unpaired t-test analysis was used to determine if the tooth sections with cracks allowed higher power passage compared to sound teeth. Results The mean power recording for the cracked teeth (Group A) was significantly greater (p = 0.0005) than that for the non-cracked teeth (Group B). Conclusion Within the limitations of this study, it is evident that significantly higher laser energy passes through teeth with cracks in comparison to teeth without cracks. A recent clinical study has also shown that lasers could be used to assess symptomatic cracked teeth. Hence, further research is required to determine the relative increase in energy required to identify symptomatic cracked teeth.

Development of Video Transmission Device for Monitoring of a Cable-Based Retractable Roof (케이블-기반 개폐식 지붕의 모니터링을 위한 영상 전송 장치 개발)

  • Ahn, Soohong;Shon, Sudeok;Lee, Seungjae;Kang, Joo-Won
    • Journal of Korean Association for Spatial Structures
    • /
    • v.19 no.4
    • /
    • pp.103-110
    • /
    • 2019
  • The cable-based retractable membrane roof makes it impossible to maintain its shape and stiffness during driving process, unlike the hard-type retractable roof. Consequently, monitoring using a relatively simple wireless video transmission device is required. However, since video data has a bigger transmission rating than other monitoring data in terms of the structure velocity or acceleration, there is a need to develop transmission device that is easy to install and entails low maintenance cost. This paper studies on a real-time video transmission system for monitoring the cable-based retractable membrane roof while driving. A video transfer software, using the mobile network, is designed and the embedded system is constructed. Ultimately, the data transmission server is tested. Connecting a trolley to the system allows testing of the validity and efficiency of the developed system through the video data transmitted in the driving process. Result of the test shows that the developed system enables multi-device data transfer with monitoring via the mobile network.

Development of the Technical Calculation System for Transmission Line in Myanmar (미얀마 송전선로 설계 기술계산시스템 개발)

  • Baik, Seung-Do;Min, Byeong-Wook;Kim, Jong-Hwa;Shin, Tai-Woo;Kim, Sae-Hyun;Park, Jae-Ung
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.632-634
    • /
    • 2005
  • Korea takes part in overseas business by use of accumulated advanced technology through construction of the worlds first 765kV double circuit transmission system designed with pure local technology. 'Development Study on the Power System Network Analysis in Myanmar' was received in the year 2001 and was completed in the year 2002. The following project,'Feasibility Study and Basic Designs for the 500kV Transmission System in Myanmar' has been in progress since January, 2004. With regards to this project the master plan for the Myanmar long term power system was submitted in January 2005, and now the basic designs for the 500kV transmission system construction are in progress. Technical data for the design of the transmission line is calculated using a very complex numerical formula that is almost impossible to be completed by hand. So the transmission technical calculation system was developed to calculate and support Myanmar technical data for the design of transmission line with respect to factors such as wind prossure load, tower design data conductor design data and insulator design data on the basis of weather conditions for the Myamar transmission line design area of the Myanmar 500kV trans- mission line construction basic design.

  • PDF

Seed Transmission Rates of Bean pod mottle virus and Soybean mosaic virus in Soybean May Be Affected by Mixed Infection or Expression of the Kunitz Trypsin Inhibitor

  • Nam, Moon;Bae, Hanhong;Hammond, John;Domier, Leslie L.;Youn, Young-Nam;Lee, Bong-Choon;Lim, Hyoun-Sub
    • Research in Plant Disease
    • /
    • v.19 no.2
    • /
    • pp.114-117
    • /
    • 2013
  • To facilitate their spread, plant viruses have developed several methods for dispersal including insect and seed transmission. While insect transmission requires virus stability against insect digestion, seed-transmitted viruses have to overcome barriers to entry into embryos. Bean pod mottle virus (BPMV) is transmitted through seed at levels typically below 0.1%, but co-infection with Soybean mosaic virus (SMV) enhanced the seed transmission rate of BPMV in one experiment. In contrast, the rate of SMV seed transmission was not affected by BPMV co-infection. In a second preliminary study, the rate of SMV transmission was lower in an isoline of Williams 82 that contained a null mutation for the Kunitz trypsin inhibitor gene than in Williams 82. In this preliminary study, we observed that factors such as protease inhibitor expression and dual infection may affect the frequency of seed transmission of BPMV and SMV.

Identification and Seed Transmission of Peanut Viruses Occurenced in Honam Area (호남지방에 발병되는 땅콩바이러스의 분리, 동정 및 종자전염)

  • So, In-Young;Cheong, Seong-Soo;Chon, Kil-Hyong
    • Applied Microscopy
    • /
    • v.22 no.1
    • /
    • pp.55-69
    • /
    • 1992
  • Viral disease incidence in the peanut fields at Iri, Kochang, Iksan and Puan in Chonbuk province was 0.93% on July and 8.46% on August in 1991. The causal pathogen was identified as peanut stripe virus (PStV) by the results of host plant reaction, immunological assay and observation of virus particles. Seed transmission rates of collected seeds from diseased plants ranged from 12.9 to 14.8% at peanut fields. PStV transmission was higher in small than in large seeds. Seed transmission of PStV was correlated with the age of the plant when inoculated; infection of young plants resulted in more seed transmission than did infection of old plants. Seed transmission of PStV was correlated with pod formation stages when inoculated at the 45th day after sowing; formed seeds for 2 weeks after inoculation resulted in more seed transmission than did formed seeds after 4 weeks. In seed transmission, this causal virus was moved to embryo and cotyledon through gynophore, pod, and funicle from leaves.

  • PDF