• Title/Summary/Keyword: Threshold angle

Search Result 183, Processing Time 0.037 seconds

The Effect of Applying Various Tools to the Stiffness and Muscle Tone of Hamstring Muscles (다양한 도구의 적용이 뒤넙다리근의 뻣뻣함과 근 긴장도에 미치는 영향)

  • Hwang, Sunghyun;Kim, Taeho
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.8 no.4
    • /
    • pp.223-230
    • /
    • 2020
  • Purpose : The purpose of this study was to examine the effects of tools (i., extracorporeal shock wave therapy, massage gun, and foam roller) on range of motion, muscle tone and pain threshold among patients with hamstring stiffness. Methods : Fourteen participants with hamstrings stiffness were recruited. Interventions were performed 6 times, and each session was for 30 seconds using the three tools. The range of motion, muscle tone, and pain threshold were measured. The order of the use of the three tools was randomly determined. The foam roller was made to move from the bottom of the hip crease to the upper part of the back of the hamstring. Additionally, velocity 5 vibration stimulation was performed on the hamstring using a massage gun. Moreover, vibration stimulation was performed on the hamstring with extracorporeal shock wave therapy 5 minutes, 5 Hz, and 1,500 strokes. The flexibility of the posterior thigh muscle was based on maintaining the knee and hip joints in a 90 ° bend in the supine position. The joint angle of the knee was measured, when the knee was actively extended, at the maximum point where the posterior thigh muscle was stretched. The elasticity of the posterior thigh muscle was measured while the subject was prone and in a relaxed state without any force. Measurements were made at the muscle abdominal area of the semitendinosus muscle of the posterior femur, and the area to be measured was marked with a pen. The measurement of the tenderness threshold of the posterior femur was measured using a tenderness meter(Commander Algometer, J-Tech, USA). The force value at the point at which the pressure sensation change to pain was measured after applying vertical pressure to the posterior femur muscle, which was the halfway point between the ischial tuberosity and the popliteal surface of the subject lying on their stomach. Results : The extracorporeal shock wave therapy increased stiffness and, muscle tone, and caused changes in the pain threshold, whereas the other two tools had no effect on these indices. Conclusion : Extracorporeal shock wave therapy has important effects on range of motion and muscle stiffness and can be used in warmup protocols.

Organic Thin Film Transistors with Gate Dielectrics of Plasma Polymerized Styrene and Vinyl Acetate Thin Films

  • Lim, Jae-Sung;Shin, Paik-Kyun;Lee, Boong-Joo
    • Transactions on Electrical and Electronic Materials
    • /
    • v.16 no.2
    • /
    • pp.95-98
    • /
    • 2015
  • Organic polymer dielectric thin films of styrene and vinyl acetate were prepared by the plasma polymerization deposition technique and applied for the fabrication of an organic thin film transistor device. The structural properties of the plasma polymerized thin films were characterized by Fourier-transform infrared spectroscopy, X-ray diffraction, atomic force microscopy, and contact angle measurement. Investigation of the electrical properties of the plasma polymerized thin films was carried out by capacitance-voltage and current-voltage measurements. The organic thin film transistor device with gate dielectric of the plasma polymerized thin film revealed a low operation voltage of −10V and a low threshold voltage of −3V. It was confirmed that plasma polymerized thin films of styrene and vinyl acetate could be applied to functional organic thin film transistor devices as the gate dielectric.

ROLLOVER INDEX-BASED ROLLOVER MITIGATION CONTROL SYSTEM

  • Yoon, J.;Yi, K.;Kim, D.
    • International Journal of Automotive Technology
    • /
    • v.7 no.7
    • /
    • pp.821-826
    • /
    • 2006
  • This paper describes a rollover index (RI)-based rollover mitigation control (RMC) system. A rollover index which indicates an impending rollover has been developed by a roll dynamics phase plane analysis. The rollover index is calculated using the roll angle, the roll rate, the lateral acceleration and time to wheel lift (TTWL). A differential braking control law based on a 2-D bicycle model has been designed using the direct yaw control (DYC) method. An RMC threshold has been determined from the rollover index. The performance of the RMC scheme and the effectiveness of the proposed rollover index are illustrated using a vehicle simulator.

Walk-off Output Characteristics of OPO Pumpedby SHG of Nd:YAG Laser (Nd:YAG 레이저의 SHG로 펌핑된 OPO의 Walk-off 출력특성)

  • 이용우
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2003.05a
    • /
    • pp.419-423
    • /
    • 2003
  • In this paper, we have constructed singly resonant KTP OPO system pumped by 532 nm to obtain broadly frequency tunable pulses. Also we have mathematically simulated frequency tuning range, phase matching angle for 900 nm output and threshold energy, and we calculated output intensity using wave propagation equations for optical parametric oscillator which include walk-off, pump depletion.

  • PDF

Unified Chassis Control to Prevent Vehicle Rollover (차량전복 방지를 위한 통합섀시제어)

  • Yoon, Jang-Yeol;Yi, Kyoung-Su;Cho, Wan-Ki;Kim, Dong-Shin
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.1132-1137
    • /
    • 2007
  • This paper describes a Unified Chassis Control (UCC) strategy to prevent vehicle rollover by integrating individual modular chassis control systems such as Electronic Stability Control (ESC) and Continuous Damping Control (CDC). The UCC threshold is determined from a rollover index computed by estimated roll angle, roll rate and measured lateral acceleration. A direct yaw moment control method is used to design the ESC based on a 2-D bicycle model. Similarly, the CDC is designed based on a 2-D roll model using a direct roll moment control method. The performance of the proposed UCC scheme is investigated and compared to that of modular chassis controllers through computer simulations using a validated vehicle simulator. It is shown that the proposed the UCC can lead to improvements in vehicle stability and efficient actuation of chassis control systems.

  • PDF

A Study on an Application of the Protection for the Visual Segment of the Approach Procedure focused on Taean Airport (접근절차의 시계구간 보호 적용 연구 - 태안비행장을 중심으로 -)

  • Kim, Dohyun;Hong, Seung Beom
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.22 no.2
    • /
    • pp.9-15
    • /
    • 2014
  • 'Visual segment surface' means a surface that extends from the missed approach point of non precision approaches (or the decision altitude location for approaches with vertical guidance and precision approaches) to the threshold to facilitate the identification of and protection from obstacles in this visual segment of the approach. Validation is the necessary final quality assurance step in the procedure design process, prior to publication. The purpose of validation is the verification of all obstacle and navigation data, and assessment of flyability of the procedure. This paper shows how to apply the protection for the visual segment of the approach procedure, and the results of the validation for visual segment surface conducted at an airport.

A TDOA Sign-Based Algorithm for Fast Sound Source Localization using an L-Shaped Microphone Array

  • Yiwere, Mariam;Rhee, Eun Joo
    • Journal of Information Technology Applications and Management
    • /
    • v.23 no.3
    • /
    • pp.87-97
    • /
    • 2016
  • This paper proposes a fast sound source localization method using a TDOA sign-based algorithm. We present an L-shaped microphone set-up which creates four major regions in the range of $0^{\circ}{\sim}360^{\circ}$ by the intersection of the positive and negative regions of the individual microphone pairs. Then, we make an initial source region prediction based on the signs of two TDOA estimates before computing the azimuth value. Also, we apply a threshold and angle comparison to tackle the existing front-back confusion problem. Our experimental results show that the proposed method is comparable in accuracy to previous three microphone array methods; however, it takes a shorter computation time because we compute only two TDOA values.

Enhancement of Off-Axis Viewing Quality with Temporal Dual Gamma Drive in Patterned Vertical Alignment Mode

  • Yang, Young-Chol;Lee, Baek-Woon;Park, Dae-Jin
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.286-289
    • /
    • 2006
  • Temporal dual gamma drive technology employing the 120Hz refresh rate was developed to enhance the off-axis viewing quality in patterned vertical alignment mode. The color shift ${\Delta}u'v'$ from on-axis to off-axis (60 deg.) for pale orange color, (R,G,B) = (196,124,96), was below 0.01, and the power exponent of gamma curve for off-axis viewing angle (60 deg.) was about 1.8, when the gamma curve for on-axis was set with power exponent of 2.4. The off-axis image distortion index was below 0.180 in contrast to the normal case ${\sim}0.23$. To elevate the response speed of liquid crystal in the intra-frame, the voltage below threshold voltage of liquid crystals was used.

  • PDF

Characteristics measurement of fabricated micromirror array with vertical springs (제작된 수직 마이크로미러 어레이의 특성 측정)

  • Shin, Jong-Woo;Kim, Yong-Kweon;Park, Jin-Goo;Shin, Hyung-Jae;Moon, Jae-Ho
    • Proceedings of the KIEE Conference
    • /
    • 1997.11a
    • /
    • pp.618-620
    • /
    • 1997
  • A $50{\times}50{\mu}m^2$ aluminum micromirror array is fabricated using shadow evaporation process. The fabrication process is very simple with use of shadow evaporation process, and the micromirror array has a high fill-factor. The static and dynamic characteristics such as deflection angle vs. applied voltage, step response, and frequency response are measured using a contact free optical measurement technique. The downward threshold voltage was 8 V, step response time was $13.5{\mu}s$ when 32 V step voltage applied, and a resonance observed at 11kHz. The lifetime of micromirror with anti-stiction coating was tested and micromirror operated successfully over 200 million cycles of touch-down operations.

  • PDF

Estimation of Human Height Using Downward Depth Images (하방 촬영된 깊이 영상을 이용한 신장 추정)

  • Kim, Heung-Jun;Lee, Dong-Seok;Kwon, Soon-Kak
    • Journal of Korea Multimedia Society
    • /
    • v.20 no.7
    • /
    • pp.1014-1023
    • /
    • 2017
  • In this paper, we propose a method for estimating the human height by using downward depth images. We detect a point with the lowest depth value in an object as top of the head and estimate the height by calculating the depth difference with the floor. Since the depth of the floor varies depending on the angle of the camera, the correction formula is applied. In addition, the binarization threshold is variably applied so that height can be estimated even when several people are adjacent. Simulation results show that the proposed method has better performance than the conventional methods. The proposed method is expected to be widely used in body measurement, intelligent surveillance, and marketing.