• Title/Summary/Keyword: Threshold Level

Search Result 1,287, Processing Time 0.03 seconds

Threshold level analysis of the FFH-MA system using noncoherent FSK modulation under the presence of frequency and timing offsets (주파수와 타이밍 옵셋에 의한 빠른 주파수 호핑 시스템의 임계값 분석)

  • Jeungmin Joo;Yeomin Yoon;Miheung Choe;Lee, Kwangeog;Kim, Kiseon
    • Proceedings of the IEEK Conference
    • /
    • 2003.07a
    • /
    • pp.226-229
    • /
    • 2003
  • Under the prsence of the frequency and timing offset, we evaluate the BER performance of the FFH-MA system using noncoherent M-ary FSK modulation in the Rayleigh fading channel. The numerical resuts show that while the frequency and timing offset increases at a given SNR, the BER is severely degraded. The threshold level used in the envelope detector increases with the increase of the frequency and timing offset, and with the proper selection of the threshold level, the BER can be improved under the presence of such offsets.

  • PDF

Therapeutic Effects of Korean Medical Treatment Combined with Threshold Sound Conditioning on Bilateral Sudden Sensorineural Hearing Loss : A Case Report (한방 복합 치료 및 소리재활치료로 호전된 양측성 돌발성 난청 치험 1례)

  • Park, Soyoung;Jea, Ha-Kyung;Min, Ye-Eun;Kang, Jun-Hyeok;Hong, Eun-Been
    • The Journal of Korean Medicine Ophthalmology and Otolaryngology and Dermatology
    • /
    • v.35 no.2
    • /
    • pp.72-81
    • /
    • 2022
  • Objectives : The purpose of this study is to report the case of a bilateral sudden sensorineural hearing loss patient whose hearing had improved by Korean medical treatment combined with threshold sound. Methods : A woman diagnosed with bilateral sudden sensorineural hearing loss has treated with Korean medical interventions(acupuncture combined with electromagnetic stimulation and pharmacoacupuncture) and threshold sound conditioning(TSC) for 20 weeks. Pure tone audiometry(PTA) was performed for the evaluation. Results : The average hearing level has improved from mild to normal level. The level of tinnitus has decreased from VAS 10 to VAS 4. Conclusions : We observed an improvement in a bilateral sudden sensorineural hearing loss patient's hearing and hereby suggest the possibility of Korean medical treatment and TSC's ameliorating effect on sensorineural hearing loss.

Effect of Cochlear Implant Electrode Array Design on Electrophysiological and Psychophysical Measures: Lateral Wall versus Perimodiolar Types

  • Lee, Ji Young;Hong, Sung Hwa;Moon, Il Joon;Kim, Eun Yeon;Baek, Eunjoo;Seol, Hye Yoon;Kang, Sihyung
    • Journal of Audiology & Otology
    • /
    • v.23 no.3
    • /
    • pp.145-152
    • /
    • 2019
  • Background and Objectives: The present study aims to investigate whether the cochlear implant electrode array design affects the electrophysiological and psychophysical measures. Subjects and Methods: Eighty five ears were used as data in this retrospective study. They were divided into two groups by the electrode array design: lateral wall type (LW) and perimodiolar type (PM). The electrode site was divided into three regions (basal, medial, apical). The evoked compound action potential (ECAP) threshold, T level, C level, dynamic range (DR), and aided air conduction threshold were measured. Results: The ECAP threshold was lower for the PM than for the LW, and decreased as the electrode site was closer to the apical region. The T level was lower for the PM than for the LW, and was lower on the apical region than on the other regions. The C level on the basal region was lower for the PM than for the LW whereas the C level was lower on the apical region than on the other regions. The DRs on the apical region was greater for the PM than for the LW whereas the DR was narrower on the apical region than on the other regions. The aided air conduction threshold was not different for the electrode design and frequency. Conclusions: The current study would support the advantages of the PM over the LW in that the PM had the lower current level and greater DR, which could result in more localized neural stimulation and reduced power consumption.

Effect of Cochlear Implant Electrode Array Design on Electrophysiological and Psychophysical Measures: Lateral Wall versus Perimodiolar Types

  • Lee, Ji Young;Hong, Sung Hwa;Moon, Il Joon;Kim, Eun Yeon;Baek, Eunjoo;Seol, Hye Yoon;Kang, Sihyung
    • Korean Journal of Audiology
    • /
    • v.23 no.3
    • /
    • pp.145-152
    • /
    • 2019
  • Background and Objectives: The present study aims to investigate whether the cochlear implant electrode array design affects the electrophysiological and psychophysical measures. Subjects and Methods: Eighty five ears were used as data in this retrospective study. They were divided into two groups by the electrode array design: lateral wall type (LW) and perimodiolar type (PM). The electrode site was divided into three regions (basal, medial, apical). The evoked compound action potential (ECAP) threshold, T level, C level, dynamic range (DR), and aided air conduction threshold were measured. Results: The ECAP threshold was lower for the PM than for the LW, and decreased as the electrode site was closer to the apical region. The T level was lower for the PM than for the LW, and was lower on the apical region than on the other regions. The C level on the basal region was lower for the PM than for the LW whereas the C level was lower on the apical region than on the other regions. The DRs on the apical region was greater for the PM than for the LW whereas the DR was narrower on the apical region than on the other regions. The aided air conduction threshold was not different for the electrode design and frequency. Conclusions: The current study would support the advantages of the PM over the LW in that the PM had the lower current level and greater DR, which could result in more localized neural stimulation and reduced power consumption.

Comparison of a hearing threshold level using a headphone (헤드폰을 이용한 가청역치레벨의 측정 방법 비교)

  • Kim, Deuk-Seong;Jang, Seol-Il;Kim, Dong-Jun;Lee, Yeon-Su
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.796-801
    • /
    • 2007
  • This research presents a laboratory study about a comparison between two methods that measure a hearing threshold of the Subjects who participated in an experiment of the Jury test. The Subjects heard a signal by a headphone. The Subjects of total 63 persons (man=42, woman=21 persons) participated in an experiment. A test of hearing was divided into two (Top-Down, Bottom-Up) methods. Total time of hearing test was about 80 minute(40min/day). As a results of the hearing test, a hearing threshold of the Subjects who used to wear a headphone was higher than that of the Subjects who not used to wear a headphone. A hearing threshold of a man was higher than that of a woman. The result of hearing test was showed that ISO's hearing threshold(MAF) was lower than a result that get from an experiment.

  • PDF

An Algorithm for Bit Error Rate Monitoring and Adaptive Decision Threshold Optimization Based on Pseudo-error Counting Scheme

  • Kim, Sung-Man
    • Journal of the Optical Society of Korea
    • /
    • v.14 no.1
    • /
    • pp.22-27
    • /
    • 2010
  • Bit error rate (BER) monitoring is the ultimate goal of performance monitoring in all digital transmission systems as well as optical fiber transmission systems. To achieve this goal, optimization of the decision threshold must also be considered because BER is dependent on the level of decision threshold. In this paper, we analyze a pseudo-error counting scheme and propose an algorithm to achieve both BER monitoring and adaptive decision threshold optimization in optical fiber transmission systems. To verify the effectiveness of the proposed algorithm, we conduct computer simulations in both Gaussian and non-Gaussian distribution cases. According to the simulation results, BER and the optimum decision threshold can be estimated with the errors of < 20% and < 10 mV, respectively, within 0.1-s processing time in > 40-Gb/s transmission systems.

Threshold Level Setting of a Receiver in Optical Subscriber Network with Manchester Coded Downstream and NRZ Upstream Re-modulation for the Improvement of Upstream Data Ratios (맨체스터 부호로 코딩된 하향신호의 재변조를 이용한 광가입자 망에서 상향속도개선을 위한 임계치의 설정)

  • Park, Sang-Jo
    • Journal of the Korea Society of Computer and Information
    • /
    • v.16 no.12
    • /
    • pp.175-185
    • /
    • 2011
  • The threshold level of a receiver is analyzed for the simplification of system and the improvement of upstream data ratios in optical subscriber network of which the upstream date rate and the optical transmitted power are changed to meet the requested BER (Bit Error Rate) defined per interactive multimedia services. In asynchronous optical subscriber network of which the upstream to downstream data ratios are 1:1/2, 1:1/4, 1:1/8 and 1:1/16 with manchester coded downstream and NRZ (Non Return to Zero) downstream re-modulation, the BER performance is theoretically analyzed and it is performed by simulation with MATLAB according to the four types of downstream data for four models. The results have shown that in the cases which the upstream to downstream data ratios are 1:1/4, 1:1/8 and 1:1/16 the conventional receiver with threshold level of 1/2 can be applied regardless of average received optical powers and the BER is not much deteriorated compared with using the optimal threshold level. In the case that the upstream to downstream data ratio is 1:1/2 the threshold level in an optical receiver could be fixed at 1/3 and the BER is not much deteriorated compared with using the optimal threshold level as the average received optical power increases.

Effect of Acupuncture-like Transcutaneous Electrical Nerve Stimulation on Plasma $\beta-endorphin$ and ACTH, Serum Cortisol and Urinary 17-OHCS Levels (저빈도-고강도 경피신경전기자극이 혈장 $\beta-endorphin$ 과 ACTH, 혈청 Cortisol 및 요중 17-OHCS 농도에 미치는 영향)

  • Park Chun-Seo;Lee Jae-Hyoung
    • The Journal of Korean Physical Therapy
    • /
    • v.6 no.1
    • /
    • pp.5-15
    • /
    • 1994
  • The purpose of this study was to examine the effect of electroanalgeia and $\beta-endorphin$ action by acupuncture-like (Lof/Hil) transcutaneous electrical nerve stimulation (TENS) applied to acupuncture points. Twelve healthy adult male aged between 19 ann 25 were randomly assigned to TENS group (n=6) and naloxone group (n=6). Subjects of both groups were strongly stimulated TENS with 4 pps and $200{\mu}s$ for 30 minutes on the LI 3 and LI 10 meridian points of dominant am. Naloxone group was injected naloxone hydrochloride before TENS application. The experimental pain threshold was measured by chronaxie meter CX-2 on the distal end of radius just before and after TENS application. The levels of plasma $\beta-endorphin$ and ACTH. serum cortisol and urinary 17-OHCS were analyzed by radioimmunoassay (RIA) kits before and after TENS application. In TENS group, there was a significant increase of experimental pain threshold (p<0.01), plasma $\beta-endorphin$ level (p<0.05), serum cortisol level (p<0,001) and urinary 17-OHCS levels (p<0.05) after TENS application. The plasma ACTH level was not significantly increased, but it showed an increasing tendency. In naloxone group, although there was a decreasing trend, ACTH and cortisol level did not show a significant change, but $\beta-endorphin$ and 17-OHCS level were significantly decreased (p<0.01). The result of this study stewed that acupuncture-like TENS induced analgesic effect, such that the levels of plasma $\beta-endorphin$, plasma ACTH, serum cortisol and urinary 17-OHCS were concomitantly increased with experimental pain threshold. It is suggested that the analgesic mechanism of the acupuncture-like TENS probably related to endogenous opioid component such as $\beta-endorphin$.

  • PDF

FPGA based Dynamic Thresholding Circuit

  • Cho, J.U.;Lee, S.H.;Jeon, J.W.;Kim, J.T.;Cho, J.D.;Lee, K.M.;Lee, J.H.;Byun, J.E.;Choi, J.C.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.1235-1238
    • /
    • 2004
  • Thresholding has been used to reduce the number of gray values in images. Typically, a single threshold value has been used, resulting in two gray level images. Image reduction of one single threshold value, however, may lose too much of the high-frequency edge information. Thus, dynamic thresholding that uses a different threshold for each pixel is preferred instead of using a single threshold value. Dynamic thresholding can preserve high frequency details as well as reduce the size of images. Since it takes long time to perform existing software dynamic thresholding in an embedded system, this paper proposes and implements a circuit by using a FPGA in order to perform a real-time dynamic thresholding,. The proposed circuit consists of two counters, and threshold look-up table, and control unit. The values of two counters determine each pixel position, the threshold look-up table converts each pixel value into other value, and the control unit generates necessary control signals. On arriving from a camera to the proposed circuit, each pixel is compared with its threshold value and is converted into other gray value. An image processing system by using the proposed circuit will be implemented and some experiments will be performed.

  • PDF

Multilevel Threshold Selection Method Based on Gaussian-Type Finite Mixture Distributions (가우시안형 유한 혼합 분포에 기반한 다중 임계값 결정법)

  • Seo, Suk-T.;Lee, In-K.;Jeong, Hye-C.;Kwon, Soon-H.
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.17 no.6
    • /
    • pp.725-730
    • /
    • 2007
  • Gray-level histogram-based threshold selection methods such as Otsu's method, Huang and Wang's method, and etc. have been widely used for the threshold selection in image processing. They are simple and effective, but take too much time to determine the optimal multilevel threshold values as the number of thresholds are increased. In this paper, we measure correlation between gray-levels by using the Gaussian function and define a Gaussian-type finite mixture distribution which is combination of the Gaussian distribution function with the gray-level histogram, and propose a fast and effective threshold selection method using it. We show the effectiveness of the proposed through experimental results applied it to three images and the efficiency though comparison of the computational complexity of the proposed with that of Otsu's method.