• Title/Summary/Keyword: Threshold Level

Search Result 1,287, Processing Time 0.027 seconds

For 5-years the Longitudinal Study on the Effect of Noise Exposure and Aging to the Changes of Hearing Threshold Level (청력에 대한 연령과 소음 노출의 영향에 관한 5년간 청력역치 변화)

  • Chae, Chang Ho;Kim, Ja Hyun;Son, Jun Seok
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.25 no.4
    • /
    • pp.573-583
    • /
    • 2015
  • Objectives: This study was carried out to evaluate the effect of noise exposure and aging on changes in hearing threshold level and the relationship between age and noise. Materials: The author selected 274 male shipyard and assembly line workers as the noise exposed group and 582 males not exposed to noise as the general population group. Data were collected from five years of consecutive annual audiometric tests performed from 2008 to 2012. Results: In the general population and noise exposed groups, there was a reverse phenomenon that hearing threshold level for 2009 was lower than that of 2008, which seemed to be due to the learning effect, but from 2010 hearing threshold level increased. In the noise exposed group, the mean hearing threshold level in the left ear was significantly higher than that for right ear. In the general population group, the older was the age, the higher was the hearing threshold level, especially at 4000 Hz. In the general population and noise exposed groups, frequency, age group and noise exposure independently affected hearing threshold level, and there was no relationship between age and noise exposure. Over all frequencies, the change of hearing threshold level was larger in the noise exposed group than in the general population group. In the noise exposed group below thirty years old, the change at 4000 Hz was remarkable. Conclusions: Age and noise exposure seem to affect hearing threshold level independently and contribute to an additive effect on hearing threshold level.

Difference of Time Weighted Averages in Different Setting Ups for Noise Dosimeter (소음노출량측정기의 Set Up 방법간의 시간가중평균값(TWA)의 차이)

  • Yang, Hong Seok;Lee, Kwang Mook;Won, Jung Il
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.5 no.2
    • /
    • pp.193-199
    • /
    • 1995
  • This study was designed to investigate the difference of time weighted average(TWA) of noise levels and noise doses by the different operating parameter settings such as exchange rate, threshold level and criterion level for noise dosimeter in the field measurements of noise at industrial working environments. The time weighted averages of noise level and noise doses for noise working environments were determined by noise dosimeter on 80 workers employed at 20 industrial establishments of 8 industries. The results obtained were as follows: 1. The mean time weighted average(TWA) of the noise working environments by the operating parameter settings showed 93.4 dB(A) in 3 dB of exchange rate, 80 dB of threshold level and 90dB of criterion level 92.0 dB(A) in 3 dB-exchange rate, 90 dB-threshold level and 90 dB-criterion level, in 90.8 dB(A) in 5 dB of exchange rate, 80 dB of threshold level and 90 dB of criterion level, and 86.7 dB(A) in 5 dB of exchange rate, 90 dB of threshold level and 90dB of criterion level. 2. ln group of noise level less than 90 dB(A), mean TWAs of 80 dB of threshold level were significantly higher than that of 90 dB of threshold level in 3 dB and 5 dB of exchange rate. 3. The case exceeded threshold limit value of noise was 49(61.3 %) in 3dB, 80dB and 90 dB setting, 44(55.0 %) in 3 dB, 90 dB, 90 dB setting, 33(41.3 %) in 5 dB, 80dB, 90 dB setting and 26(32.5%) in 5 dB, 90 dB, 90 dB setting. Above considerations in mind, it is suggested that exchange rate and threshold level be specified in related laws and regulations in the evaluation of working environments noise.

  • PDF

Comparison of Safety Level between Driver's Ages by Threshold Zone Luminance Level of Vehicular Traffic Tunnel (터널 경계부 휘도수준에 따른 운전자 연령대별 안전수준 비교)

  • Cho, Won Bum;Jeong, Jun Hwa;Kim, Do Gyeong;Park, Won Il
    • International Journal of Highway Engineering
    • /
    • v.17 no.1
    • /
    • pp.129-142
    • /
    • 2015
  • PURPOSES : The purpose of this study is to suggest a basis for setting appropriate safety goals specifically related to the threshold zone luminance in a vehicular traffic tunnel. METHODS : In the test, drivers were divided into two groups. One group consisted of all drivers (average drivers) group with an age ratio of drivers holding domestic driver's license and driver group by age to produce threshold zone luminance in the tunnel. The threshold zone luminance produced as a result was used to analyze how it affects the safety level of each driver group and provide a basis for setting an appropriate safety criterion that can be used to determine threshold zone luminance. We used test equipment, test conditions, and ananalysis of threshold zone luminance identical to that reported by ChoandJung(2014) but the values of adaptation luminance in our analys is were expanded to range from100 to $10,000cd/m^2$. RESULTS : Adaptation luminance and threshold zone luminance are found to be related by a quadratic function. The threshold zone luminance needed by older drivers to ensure a certain safety level is significantly higher than that for drivers of other age brackets when adaptation luminance increases. 56% of older drivers are at an increased risk of an accident at the same luminance for which the safety level of average drivers is 75%. The safety level that can be achieved for older drivers increases to above 60% when threshold zone luminance level is set with the goal of attaining a safety level of more than 85% for average drivers. The safety level that can be attained for average drivers is above 90% when the threshold zone luminance is high enough to ensure over 75% in the safety level of older drivers. Results of this study are applicable to highways and others whose designed speed is 100 km/h. CONCLUSIONS : Threshold zone luminance determined on the basis of drivers having average visual ability is of limited value as a performance standard for ensuring the safety of older drivers. Hence, safety level for older drivers should be considered separately from safety levels for drivers with an average ability to avoid risk. Upward adjustment of older drivers' safety level in the process of determining appropriate threshold zone luminance in a vehicular traffic tunnel may bring both tangible and intangible benefit as a result of reducing accidents. However, there is an associated dollar cost arising from installing and operating lights. As a result, the economic impact of these trade-offs should also be considered.

Study on Relations among Use of Earphones, Stress, and Hearing Threshold in University Students (대학생의 이어폰 사용, 스트레스 및 청력의 관계)

  • Kwak, Hye-Weon;Kim, Na-Hyun
    • Journal of Korean Public Health Nursing
    • /
    • v.26 no.1
    • /
    • pp.126-136
    • /
    • 2012
  • Purpose: The purpose of this study was to investigate the relationship among use of earphones, stress level, and hearing threshold in university students. Methods: Study subjects included 210 university students (76 men, 134 women). Data were collected by questionnaire and audiometer from December 17 to 20, 2011. The SPSS win 19.0 program was used for data analysis by descriptive statistics, t-test, one-way ANOVA, and Pearson's correlation coefficient. Results: 1) 4KHz, 6KHz hearing threshold of subjects who used earphones was higher than average hearing threshold of same age group. 2) Not significant differences in hearing threshold were observed according to frequency of use, and stress level. 3) Significant differences in 4KHz hearing threshold were observed according to earphone volume. 4) A significant positive correlation was observed between frequency of use and stress level (r=0.15, p<.05), earphone volume, and 4KHz hearing threshold (left) (r=0.15, p<.05); however, a negative correlation was observed between stress level and 4KHz hearing threshold (right) (r=-0.14, p<.05). Conclusion: A significant positive correlation was observed between frequency of use and stress level and earphone volume and 4KHz hearing threshold (left). Development of a program for hearing conservation is needed.

A Study on Efficient Threshold Level for False Alarm Probability Decrease (오 경보 확률 감소를 위한 효율적인 임계치에 대한 연구)

  • Lee, Kwan-Hyeong
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.8 no.2
    • /
    • pp.140-146
    • /
    • 2015
  • We have studied an efficient threshold level for desired target detection in radar system in the paper. A desired target searching detection method detects desired target according to changing for false alarm probability. This time, false alarm probability is close relation to threshold level. Low threshold level can improve detection for desired target, but detect noise signal. Therefor, This method is not good one. In this paper, we propose efficient threshold level method in order to estimation for desired target. Through simulation, we are analysis and performance to compare general method with proposal method. We show that proposed method is more good proof than general method.

Application of Streamflow Drought Index using Threshold Level Method (임계수준 방법을 이용한 하천수 가뭄지수의 적용)

  • Sung, Jang Hyun;Chung, Eun-Sung
    • Journal of Korea Water Resources Association
    • /
    • v.47 no.5
    • /
    • pp.491-500
    • /
    • 2014
  • To estimate the severity of streamflow drought, this study introduced the concept of streamflow drought index based on threshold level method and Seomjingang Dam inflow was applied. Threshold levels used in this study are fixed, monthly and daily threshold, The $1^{st}{\sim}3^{rd}$ analysis results of annual drought, the severe hydrological droughts were occurred in 1984, 1988 and 1995 and the drought lasted for a long time. Annual compared to extreme values of total water deficit and duration, the drought occurred in 1984, 1988, 1995 and 2001 was serious level. In the results of study, because a fixed threshold level is not reflect seasonal variability, at least the threshold under seasonal level was required. Threshold levels determined by the monthly and daily were appropriate. The proposed methodology in this study can be used to forecast low-flow and determine reservoirs capacity.

Relationship between Adaptation Luminance and Threshold Zone Luminance for Vehicular Traffic Tunnels (터널 순응휘도와 경계부 휘도의 관계 연구)

  • Cho, Won Bum;Jeong, Jun Hwa
    • International Journal of Highway Engineering
    • /
    • v.16 no.3
    • /
    • pp.85-99
    • /
    • 2014
  • PURPOSES : This study has been performed with the objective to determine threshold zone luminance of adaptation luminance by target safety level in a vehicular traffic tunnel with design speed set at 100km/h. METHODS : The study made a miniature capable of portraying changes in luminance distribution within $2{\times}10^{\circ}$ conical field of view of the driver approaching to the tunnel for the test. Test conditions were set based on justifications for CIE 88-1990's threshold zone luminance used as a reference by domestic tunnel light standards (KS C 3703 : 2010). Luminance contrast of object background and object is 23%, object presentation duration is 0.5 seconds, and size of the object background is $7.3{\times}11.5m^2$ RESULTS : Threshold zone luminance was set within adaptation luminance of $100{\sim}3,000cd/m^2$. Adaptation luminance and threshold zone luminance based on 50%, 75% and 90% target safety level all showed a relatively high linear relationship. According to findings in the study, it is not appropriate to specify the relationship between adaptation luminance and threshold zone luminance as luminance ratio. Rather, direct utilization of the linear relationship gained from the study findings appears to be the better solution. CONCLUSIONS : Findings of this study may be used to determine operation of threshold zone luminance based on target safety level. However, a proper verification and validity of test results are required. Furthermore, a study to determine proper threshold zone luminance level considering target safety level reviewed in this study and various decision-making factors such as economic conditions in Korea and energy-related policies should be carried out in addition. Additional tests on adaptation luminance greater than $3,000cd/m^2$ will be performed, through which application scope of the test findings will be broadened.

Outlier Detection of Real-Time Reservoir Water Level Data Using Threshold Model and Artificial Neural Network Model (임계치 모형과 인공신경망 모형을 이용한 실시간 저수지 수위자료의 이상치 탐지)

  • Kim, Maga;Choi, Jin-Yong;Bang, Jehong;Lee, Jaeju
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.61 no.1
    • /
    • pp.107-120
    • /
    • 2019
  • Reservoir water level data identify the current water storage of the reservoir, and they are utilized as primary data for management and research of agricultural water. For the reservoir storage management, Korea Rural Community Corporation (KRC) installed water level stations at around 1,600 agricultural reservoirs and has been collecting the water level data every 10 minutes. However, various kinds of outliers due to noise and erroneous problems are frequently appearing because of environmental and physical causes. Therefore, it is necessary to detect outlier and improve the quality of reservoir water level data to utilize the water level data in purpose. This study was conducted to detect and classify outlier and normal data using two different models including the threshold model and the artificial neural network (ANN) model. The results were compared to evaluate the performance of the models. The threshold model identifies the outlier by setting the upper/lower bound of water level data and variation data and by setting bandwidth of water level data as a threshold of regarding erroneous water level. The ANN model was trained with prepared training dataset as normal data (T) and outlier (F), and the ANN model operated for identifying the outlier. The models are evaluated with reference data which were collected reservoir water level data in daily by KRC. The outlier detection performance of the threshold model was better than the ANN model, but ANN model showed better detection performance for not classifying normal data as outlier.

Analysis on the Risk-Based Screening Levels Determined by Various Risk Assessment Tools (III): Proposed Methodology for Lead Risk Assessment in Korea (다양한 위해성평가 방법에 따라 도출한 토양오염 판정기준의 차이에 관한 연구(III): 우리나라 납 오염 위해성평가 방법 제안)

  • Jung, Jae-Woong;Nam, Kyoungphile
    • Journal of Soil and Groundwater Environment
    • /
    • v.20 no.6
    • /
    • pp.1-7
    • /
    • 2015
  • The most critical health effect of lead exposure is the neurodevelopmental effect to children caused by the increased blood lead level. Therefore, the endpoint of the risk assessment for lead-contaminated sites should be set at the blood lead level of children. In foreign countries, the risk assessment for lead-contaminated sites is conducted by estimating the increased blood lead level of children via oral intake and/or inhalation (United States Environmental Protection Agency, USEPA), or by comparing the estimated oral dose to the threshold oral dose of lead, which is derived from the permissible blood lead level of children (Dutch National Institute for Public Health and the Environment, RIVM). For the risk assessment, USEPA employs Integrated-Exposure-Uptake-Biokinetic (IEUBK) Model to check whether the estimated portion of children whose blood lead level exceeds 10 µg/dL, threshold blood lead level determined by USEPA, is higher than 5%, while Dutch RIVM compares the estimated oral dose of lead to the threshold oral dose (2.8 µg/kg-day), which is derived from the permissible blood lead level of children. In Korea, like The Netherlands, risk assessment for lead-contaminated sites is conducted by comparing the estimated oral dose to the threshold oral dose; however, because the threshold oral dose listed in Korean risk assessment guidance is an unidentified value, it is recommended to revise the existing threshold oral dose described in Korean risk assessment guidance. And, if significant lead exposure via inhalation is suspected, it is useful to employ IEUBK Model to derive the risk posed via multimedia exposure (i.e., both oral ingestion and inhalation).

X-ray fluorescence spectrum of the block algorithm to apply the interval threshold method using DWT (DWT를 이용한 형광 X-선 스펙트럼의 interval Threshold를 적용하기 위한 블록화 알고리즘)

  • Yang, Sang-Hoon;Lee, Jae-Hwan;Park, Dong-Sun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.5
    • /
    • pp.2291-2297
    • /
    • 2012
  • X-ray fluorescence sprectrum signal include the continuum. XRF analysis the components of material by the amplitude of peaks. XRF remove the noise and background. To remove the noise, we apply the smoothing filter. And background removal methods applied such as SNIP, Morphology, Threshold methods. In this paper, we applied Threshold using DWT. Interval threshold method divide the some blocks in particular levels. We propose the method that is divided the particular level.