• Title/Summary/Keyword: Three-phase ac/dc/ac PWM converter

Search Result 81, Processing Time 0.023 seconds

Characteristics of DC 48[V] telecommunication power supply (DC 48[V] 통신용 전원 장치의 특성)

  • Jung, H.T.;Jo, M.C.;Youn, Y.T.;Kim, J.Y.;Mun, S.P.;Suh, K.Y.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.902-904
    • /
    • 2005
  • The AC-DC converter, which has three-phase AC power as input and isolated DC power as output is used for the regulated DC power supply of the telecommunication power processing system for several kilowatt class applications. The conventional DC power supply for the telecommunication power system comprises a PWM rectifier with sine-wave shaping input current unity power factor and a DC/DC converter connected to the PWM converter, which obtains DC 48[V]. Since power passes through these two power stage converters, the conversion power loss is difficult to provide high efficiency. To resolve these problems, this paper presents a new PWM rectified as a 1-stage power conversion method. It simulation and experimental results as proved from a practical point of view that 92.1[%]of conversion efficiency and input current which can meet harmonics regulation of the Class-A in IEC61000-3-3 are achieved.

  • PDF

Characteristics of DC 48[V] telecommunication power supply (DC 48[V] 통신용 전원 장치의 특성)

  • Jung, H.T.;Jo, M.C.;Youn, Y.T.;Kim, J.Y.;Mun, S.P.;Suh, K.V.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07d
    • /
    • pp.3114-3116
    • /
    • 2005
  • The AC-DC converter, which has three-phase AC power as input and isolated DC power as output is used for the regulated DC power supply of the telecommunication power processing system for several kilowatt class applications. The conventional DC power supply for the telecommunication power system comprises a PWM rectifier with sine-wave shaping input current unity power factor and a DC/DC converter connected to the PWM converter, which obtains DC 48[V]. Since power passes through these two power stage converters, the conversion power loss is difficult to provide high efficiency. To resolve these problems, this paper presents a new PWM rectified as a 1-stage power conversion method. It simulation and experimental results as proved from a practical point of view that 92.1[%] of conversion efficiency and input current which can meet harmonics regulation of the Class-A in IEC61000-3-3 are achieved.

  • PDF

Characteristics of DC 48[V] telecommunication power supply (DC 48[V] 통신용 전원 장치의 특성)

  • Jung, H.T.;Jo, M.C.;Youn, Y.T.;Kim, J.Y.;Mun, S.P.;Suh, K.Y.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07c
    • /
    • pp.2462-2464
    • /
    • 2005
  • The AC-DC converter, which has three-phase AC power as input and isolated DC power as output is used for the regulated DC power supply of the telecommunication power processing system for several kilowatt class applications. The conventional DC power supply for the telecommunication power system comprises a PWM rectifier with sine-wave shaping input current unity power factor and a DC/DC converter connected to the PWM converter, which obtains DC 48[V]. Since power passes through these two power stage converters, the conversion power loss is difficult to provide high efficiency. To resolve these problems, this paper presents a new PWM rectified as a 1-stage power conversion method. It simulation and experimental results as proved from a Practical point of view that 92.1[%]of conversion efficiency and input current which can meet harmonics regulation of the Class-A in IEC61000-3-3 are achieved.

  • PDF

Characteristics of DC 48[V] telecommunication power supply (DC 48[V] 통신용 전원 장치의 특성)

  • Jung, H.T.;Jo, M.C.;Youn, Y.T.;Kim, J.Y.;Mun, S.P.;Suh, K.Y.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.1820-1822
    • /
    • 2005
  • The AC-DC converter, which has three-phase AC power as input and isolated DC power as output is used for the regulated DC power supply of the telecommunication power processing system for several kilowatt class applications. The conventional DC power supply for the telecommunication power system comprises a PWM rectifier with sine-wave shaping input current unity power factor and a DC/DC converter connected to the PWM converter, which obtains DC 48[V]. Since power passes through these two power stage converters, the conversion power loss is difficult to provide high efficiency. To resolve these problems, this paper presents a new PWM rectified as a 1-stage power conversion method. It simulation and experimental results as proved from a practical point of view that 92.1[%]of conversion efficiency and input current which can meet harmonics regulation of the Class-A in IEC61000-3-3 are achieved.

  • PDF

Drive of induction motor using three-phase inverter and voltage type PWM single-phase converter (전압형 PWM 단상 컨버터와 3상 인버터를 이용한 유도전동기의 운전)

  • 문상필;서기영;이현우;강욱중
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.15 no.3
    • /
    • pp.18-24
    • /
    • 2001
  • This paper deals with a three-phase Pulse width Modulation(PWM) voltage souse inverter-induction motor drive with a single-phase PWM converter. The single-phase system has the pulsating instantaneous power with twice the frequency of the ac source. The power pulsation generates the dc voltage pulsation of the converter. In result, the waveforms of the inverter output current and voltage are distorted. The steady-stare operations of the system are analyzed by employing a state-spare method Such everything confirmed it's validity throughout simulation and experiment.

  • PDF

Power factor correction of the three phase boost converter using space vector PWM strategy (공간 벡터 PWM 법을 적용한 3상 boost 콘버터의 역률개선)

  • 백종현;홍성태;배상준;배영호;권순결
    • Journal of the Korean Institute of Telematics and Electronics S
    • /
    • v.34S no.2
    • /
    • pp.104-111
    • /
    • 1997
  • In this paper, three-phase PWM AC to DC boost converter that operates with unity power factor and sinusodial input line currents is presented. The current control of this converter is based on the space vector PWM strategy with fixed switching frequency and the line currents track to reference currents within one sampling time interval. By using this control strategy low ripples in the outut current and the voltage as well as fast dynamic response are achieved with small dc link cpacitance employed.

  • PDF

A New Random SPWM Technique for AC-AC Converter-Based WECS

  • Singh, Navdeep;Agarwal, Vineeta
    • Journal of Power Electronics
    • /
    • v.15 no.4
    • /
    • pp.939-950
    • /
    • 2015
  • A single-stage AC-AC converter has been designed for a wind energy conversion system (WECS) that eliminates multistage operation and DC-link filter elements, thus resolving size, weight, and reliability issues. A simple switching strategy is used to control the switches that changes the variable-frequency AC output of an electrical generator to a constant-frequency supply to feed into a distributed electrical load/grid. In addition, a modified random sinusoidal pulse width modulation (RSPWM) technique has been developed for the designed converter to make the overall system more efficient by increasing generating power capacity and reducing the effects of inter-harmonics and sub-harmonics generated in the WECS. The technique uses carrier and reference waves of variable switching frequency to calculate the firing angles of the switches of the converter so that the three-phase output voltage of the converter is very close to a sine wave with reduced THD. A comparison of the performance of the proposed RSPWM technique with the conventional SPWM demonstrated that the power generated by a turbine in the proposed approximately increased by 5% to 10% and THD reduces by 40% both in voltage and current with respect to conventional SPWM.

Analysis of Input·Output Characteristics in the PWM Converter with Unbalance Supply Voltage (불평형 전원 전압을 갖는 PWM 컨버터의 입·출력 특성 분석)

  • Khoo, Ja-Kyeung;Kim, Sang-Hoon
    • Journal of Industrial Technology
    • /
    • v.25 no.B
    • /
    • pp.203-210
    • /
    • 2005
  • The PWM(Pulse Width Modulated) converter for the AC to DC rectification has become attractive in the industrial variable-speed drive application and the electric utilities due to the following benefits: Nearly the sinusoidal input current with unity power factor; Controllable DC link voltage; Bidirectional power flow. This paper presents a quantitative analysis of single and three phase PWM converter's input and output characteristics as a function of the input filter inductance under balanced and unbalanced conditions. Also, its performance under the supply voltage including harmonics is investigated by simulation with Matlab Simlulink and experiments. These results provide a reference for selecting the reasonable converter's input filter inductance for given harmonics or power factor criterion.

  • PDF

Pulse Width and Pulse Frequency Modulated Soft Commutation Inverter Type AC-DC Power Converter with Lowered Utility 200V AC Grid Side Harmonic Current Components

  • Matsushige T.;Ishitobi M.;Nakaoka M.;Bessyo D.;Yamashita H.;Omori H.;Terai H.
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.484-488
    • /
    • 2001
  • The grid voltage of commercial utility power source hi Japan and USA is 100rms, but in China and European countries, it is 200rms. In recent years, In Japan 200Vrms out putted single phase three wire system begins to be used for high power applications. In 100Vrms utility AC power applications and systems, an active voltage clamped quasi-resonant Inverter circuit topology using IGBTs has been effectively used so far for the consumer microwave oven. In this paper, presented is a half bridge type voltage-clamped high-frequency Inverter type AC-DC converter using which is designed for consumer magnetron drive used as the consumer microwave oven in 200V utility AC power system. This zero voltage soft switching Inverter can use the same power rated switching semiconductor devices and three-winding high frequency transformer as those of the active voltage clamped quasi-resonant Inverter using the IGBTs that has already been used for 100V utility AC power source. The operating performances of the voltage source single ended push pull type Inverter are evaluated and discussed for consumer microwave oven. The harmonic line current components In the utility AC power side of the AC-DC power converter operating at ZVS­PWM strategy reduced and improved on the basis of sine wave like pulse frequency modulation and sine wave like pulse width modulation for the utility AC voltage source.

  • PDF

A Study on the Analysis of the Output Waveform of Three-Phase Regular Sampling PWM Inverter (3상 레귤러 샘플링 PWM 인버터의 출력파행 분석에 관한 연구)

  • 노창주
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.28 no.3
    • /
    • pp.274-285
    • /
    • 1992
  • Among various Power converters, a variable voltage variable frequency (VVVF) three-phase PWM inverter is regarded as most promising power converter due to its capabilities, which permits the control of voltage, frequency and harmonic contents in a single power stage employing only on DC source. As a modulating technique of the PWM inverter, the regular sampling technique has rendered possible the on-line computation and generation of PWM control waveforms with a reasonably high switching frequencies. In this paper, microprocessor based three-phase regular samping PWM inverter with real-time control algorithm and control circuits for driving three phase AC motor has been developed. Harmocic components of PWM waveform were analized theoretically in terms of Bessel function series and then calculated by digital computer and observed with spectrum analyzer.

  • PDF