• 제목/요약/키워드: Three-leg Inverter System

검색결과 22건 처리시간 0.024초

Implementation of Space Vector Two-Arm Modulation for Independent Motor Control Drive Fed by a Five-Leg Inverter

  • Talib, Md Hairul Nizam;Ibrahim, Zulkifilie;Rahim, Nasrudin Abd.;Abu Hasim, Ahmad Shukri
    • Journal of Power Electronics
    • /
    • 제14권1호
    • /
    • pp.115-124
    • /
    • 2014
  • This paper presents the implementation of two-arm modulation (TAM) technique for the independent control of a two-induction motor drive fed by a five-leg inverter (FLI). A carrier-based space vector pulse width modulation technique for TAM is proposed to generate switching signals for FLI. Two independent three-phase space vector modulators are utilized to control two motors. The motor drive system applies two separate indirect field-oriented control methods. The stationary voltage outputs from the vector control are synthesized in the three-phase space vector modulator to generate switching signals for FLI. The performance of the independent control of the motors and the voltage utilization factor are likewise analyzed. Simulation and experimental results verify the effectiveness of the proposed method for the independent control of the two-motor drive system. The proposed technique is successfully validated by dSPACE DS1103 experimental work.

A New SVM Method to Reduce Common-Mode Voltage of Five-leg Indirect Matrix Converter Fed Open-End Load Drives

  • Tran, Quoc-Hoan;Lee, Hong-Hee
    • Journal of Power Electronics
    • /
    • 제17권3호
    • /
    • pp.641-652
    • /
    • 2017
  • This paper proposes a cost-effective topology to drive a three-phase open-end load based on a five-leg indirect matrix converter (IMC) and a space vector modulation (SVM) method. By sharing an inverter leg with two load terminals, the proposed topology can reduce the number of power switches when compared to topologies based on a direct matrix converter or a six-leg IMC. The new SVM method uses only the active vectors that do not produce common-mode voltage (CMV), which results in zero CMV across the load phase and significantly reduces the peak value of the CMV at the load terminal. Furthermore, the proposed drive system can increase the voltage transfer ratio up to 1.5 and provide a superior performance in terms of an output line-to-line voltage with a three-level pulse-width modulation waveform. Simulation and experimental results are given to verify the effectiveness of the proposed topology and the new SVM method.

유도전동기 구동을 위한 저가형 단상-3상 AC/DC/AC PWM 컨버터 (Low-Cost Single-Phase to Three-Phase AC/DC/AC PWM Converters for Induction Motor Drives)

  • 김태윤;이지명;석줄기;이동춘
    • 전력전자학회논문지
    • /
    • 제7권4호
    • /
    • pp.322-331
    • /
    • 2002
  • 본 논문은 단상 반파 PWM 정류기와 3상 2-leg 인버터를 결합한 단상-삼상 컨버터 회로에서 전원전압의 센서를 제거하여 3상 유도전동기를 저가형으로 구동하는 방법을 제안하고자 한다. 전원전압의 센서를 제거하기 위해 전원 전류의 실측치와 제어기 내의 모델전류가 일치하도록 관측기를 구성하여 전원전압을 추정한다. 본 논문에서 제안한 기법을 사용할 경우 스위칭 소자와 센서 수를 줄이면서 직류전압 일정제어, 입력전류의 정현제어 및 단위 역률 제어가 가능하고 VVVF 교류전압을 얻을 수 있다는 장점이 있다. 3[Hp]의 3상 유도전동기의 V/f 구동에 적용한 실험결과로 제시된 알고리즘의 타당성을 검증한다.

Common-Mode Voltage Elimination with an Auxiliary Half-Bridge Circuit for Five-Level Active NPC Inverters

  • Le, Quoc Anh;Park, Do-Hyeon;Lee, Dong-Choon
    • Journal of Power Electronics
    • /
    • 제17권4호
    • /
    • pp.923-932
    • /
    • 2017
  • This paper proposes a novel scheme which can compensate the common-mode voltage (CMV) for five-level active neutralpoint clamped (5L-ANPC) inverters, which is based on modifying the space vector pulse width modulation (SVPWM) and adding an auxiliary leg to the inverter. For the modified SVPWM, only the 55 voltage vectors producing low CMV values among the 125 possible voltage vectors are utilized, which varies over the three voltage levels of $-V_{dc}/12$, 0 V, and $V_{dc}/12$. In addition, the compensating voltage, which is injected into the 5L-ANPC inverter system to cancel the remaining CVM through a common-mode transformer (CMT) is generated by the additional NPC leg. By the proposed method, the CMV of the inverter is fully eliminated, while the utilization of the DC-link voltage is not decreased at all. Furthermore, all of the DC-link and flying capacitor voltages of the inverter are well controlled. Simulation and experimental results have verified the validity of the proposed scheme.

The Algorithms for Controlling AC Output Voltage of Z-Source Inverter Using Modified SVPWM

  • Tran Quang-Vinh;Chun Tae-Won;Son Jang-Kyung;Hee Lee-Hong;Ahn Jung-Ryol
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2004년도 추계학술대회 논문집
    • /
    • pp.64-69
    • /
    • 2004
  • This paper deals with an algorithm for controlling ac output voltage of Z-source inverter using Modified SVPWM (abbreviated as MSVPWM). Unlike the conventional space vector pulse width modulation, MSVPWM has one extra shoot-through zero time $T_{sh}$. During shoot-through zero time, both switches in a leg are conducted simultaneously in order to boost inverter output voltage to any desirable value regardless the line voltage. The algorithm to control linearly the capacitor voltage is suggested to improve the performance of Z-source inverter system. The performance of Z-source inverter using above algorithms is demonstrated in simulation results using PSIM. Index terms-Z-source inverter (ZSI), shoot-through time, three-phase carrier-based PWM, space vector PWM (SVPWM), modified space vector PWM (MSVPWM).

  • PDF

Utility-Interactive Four-Switch Three-Phase Soft-Switching Inverter with Single Resonant DC-Link Snubber and Boost Chopper

  • Ahmed, Tarek;Nagai, Shinichiro;Nakaoka, Mutsuo;Tanaka, Toshihiko
    • Journal of Power Electronics
    • /
    • 제7권2호
    • /
    • pp.109-117
    • /
    • 2007
  • In this paper, a novel proposal for a utility-interactive three-phase soft commutation sinewave PWM power conditioner with an auxiliary active resonant DC-link snubber is developed for fuel cell and solar power generation systems. The prototype of this power conditioner consists of a PWM boost chopper cascaded three-phase power conditioner, a single two-switch auxiliary resonant DC-link snubber with two electrolytic capacitors incorporated into one leg of a three-phase V-connection inverter and a three-phase AC power source. The proposed cost-effective utility-interactive power conditioner implements a unique design and control system with a high-frequency soft switching sinewave PWM scheme for all system switches. The operating performance of the 10 kW experimental setup including waveform quality, EMI/RFI noises and actual efficiency characteristics of the proposed power conditioner are demonstrated on the basis of the measured data.

A Simplified Control Algorithm for Three-Phase, Four-Wire Unified Power Quality Conditioner

  • Singh, Bhim;Venkateswarlu, P.
    • Journal of Power Electronics
    • /
    • 제10권1호
    • /
    • pp.91-96
    • /
    • 2010
  • In this paper, a simplified control algorithm for a three-phase, four-wire unified power quality conditioner (UPQC) is presented to compensate for supply voltage distortions/unbalance, supply current harmonics, the supply neutral current, the reactive power and the load unbalance as well as to maintain zero voltage regulation (ZVR) at the point of common coupling (PCC). The UPQC is realized by the integration of series and shunt active filters (AFs) sharing a common dc bus capacitor. The shunt AF is realized using a three-phase, four leg voltage source inverter (VSI) and the series AF is realized using a three-phase, three leg VSI. A dynamic model of the UPQC is developed in the MATLAB/SIMULINK environment and the simulation results demonstrating the power quality improvement in the system are presented for different supply and load conditions.

Control Strategy for Selective Compensation of Power Quality Problems through Three-Phase Four-Wire UPQC

  • Pal, Yash;Swarup, A.;Singh, Bhim
    • Journal of Power Electronics
    • /
    • 제11권4호
    • /
    • pp.576-582
    • /
    • 2011
  • This paper presents a novel control strategy for selective compensation of power quality (PQ) problems, depending upon the limited rating of voltage source inverters (VSIs), through a unified power quality conditioner (UPQC) in a three-phase four-wire distribution system. The UPQC is realized by the integration of series and shunt active power filters (APFs) sharing a common dc bus capacitor. The shunt APF is realized using a three-phase, four-leg voltage source inverter (VSI), while a three-leg VSI is employed for the series APF of the three-phase four-wire UPQC. The proposed control scheme for the shunt APF, decomposes the load current into harmonic components generated by consumer and distorted utility. In addition to this, the positive and negative sequence fundamental frequency active components, the reactive components and harmonic components of load currents are decomposed in synchronous reference frame (SRF). The control scheme of the shunt APF performs with priority based schemes, which respects the limited rating of the VSI. For voltage harmonic mitigation, a control scheme based on SRF theory is employed for the series APF of the UPQC. The performance of the proposed control scheme of the UPQC is validated through simulations using MATLAB software with its Simulink and Power System Block set toolboxes.

Cost-Effective Converters for Micro Wind Turbine Systems using PMSG

  • Park, Hong-Geuk;Lee, Dong-Choon;Kim, Heung-Geun
    • Journal of Power Electronics
    • /
    • 제8권2호
    • /
    • pp.156-162
    • /
    • 2008
  • This paper proposes a low-cost power converter for micro wind turbine systems using permanent magnet synchronous generators (PMSG). The proposed converter consists of a two-leg three-phase PWM inverter for the generator control and a single-phase half-bridge PWM converter which is connected to the utility grid. For the two separate DC-link voltages, a balancing control is added and the adverse effect of the DC-link voltage ripples on the inverter output voltage is compensated. The control performance of the proposed converter topology for the micro wind turbine system is shown by the simulation results using PSIM software.

NPC 인버터의 개방성 고장에 대한 새로운 고장 검출 방법 (A Novel Fault Detection Method of Open-Fault in NPC Inverter System)

  • 이재철;김태진;현동석
    • 전력전자학회논문지
    • /
    • 제12권2호
    • /
    • pp.115-122
    • /
    • 2007
  • 본 논문은 NPC 인버터(Neutral-point-clamped ye티or) 시스템을 구성하는 스위칭 소자의 개방성 고장이 발생하였을 경우 인버터 시스템의 고장 제어를 위한 새로운 고장 검출 방법을 제안하였다. 고장 스위치의 검출은 NPC 인버터 각상의 폴-전압을 이용하여 수행되며, 고장 검출 이후 연속적인 평형 3상 전력을 출력하기위해 NPC 인버터는 2상 운전 시스템으로 재구성된다. 인버터 시스템의 신뢰성 향상을 위하여 고장 검출과 시스템 재구성을 통한 고장 허용 제어를 구현하였다. 제안된 고장 검출 방법은 기존 방법보다 빠른 검출 시간을 가지며 간단한 알고리즘으로서 구현이 용이하다는 장점을 갖는다. 빠른 고장 검출 능력은 고장 검출 시간의 지연에서 올 수 있는 직류-링크 커패시터의 전압 불평형 문제, 다른 스위치의 전압 스트레스 증가로 인한 소자 파괴와 같은 악영향을 개선시킬 수 있다. 제안된 방법의 타당성을 입증하기 위하여 시뮬레이션과 실험을 수행하였다.