• 제목/요약/키워드: Three-axial

검색결과 1,409건 처리시간 0.028초

뇌전이 환자의 조영 증강 후 지연 FLAIR 영상의 유용성 (Patients with brain metastases the usefulness of contrast-enhanced FLAIR images after delay)

  • 변재후;박명환;이진완
    • 대한디지털의료영상학회논문지
    • /
    • 제16권1호
    • /
    • pp.13-19
    • /
    • 2014
  • Purpose: FLAIR image is beneficial for the diagnosis of various bran diseases including ischemic CVS, brain tumors and infections. However the border between the legion of brain metastasis and surrounding edema may not be clear. Therefore, this study aims to investigate the practical benefits of delayed imaging by comparing the image from a patient with brain metastasis before a contrast enhancement and the image 10 minutes after a contrast enhancement. Materials and methods: Of the 92 people who underwent MRI brain metastases in suspected patients 13 people in three patients there is no video to target the 37 people confirmed cases, and motion artifacts brain metastases in our hospital June-December 2013, 18 people measurement position except for the three incorrect patient (male: 11 people, female: 7 people, average age: 60 years) in the target, test equipment, 3.0T MR System (ACHIEVA Release, Philips, I was 8ChannelSENSE Head Coil use Best, and the Netherlands). TR 11000 ms, TE 125 ms, TI2800 ms, Slice Thickness 5 mm, gap 5 mm, is a Slice number 21, the parameters of the 3D FFE, T2 FLAIR variable that was used to test, TR 8.1 ms, TE 3.7 ms, Slice number 240 I set to. The experiment was conducted by acquiring the FLAIR prior to contrast enhancement (heretofore referred to as Pre FLAIR), and acquiring the 3D FFE CE five minutes after the contrast enhancement, and recomposing the images in an axial plane of S/T 3mm, G 0mm (heretofore referred to as MPR TRA CE). Using the FLAIR 10 minutes after the contrast enhancement (heretofore referred to as Post FLAIR) and Pi-View, a retrospective study was conducted. Using MRIcro on the image of a patient confirmed for his diagnosis, the images before and after the contrast media, as well as the CNR and SNR of the MPR TRA CE images of the lesion and the site absent of lesion were compared and analyzed using a one-way analysis of variance. Results: CNR for Pre FLAIR and Post FLAIR were 34.35 and 60.13, respectively, with MPR TRA CE at 23.77 showing no significant difference (p<0.050). Post-experiment analysis shows a difference between Pre FLAIR and Post FLAIR in terms of CNR (p<0.050), but no difference in CNR between Post FLAIR and MPR TRA CE (p>0.050), indicating that the contrast media had an effect only on Pre FLAIR and Post FLAIR. The SNR for the normal site Pre FLAIR was 106.43, and for the lesion site 140.79. Post FLAIR for the normal site was 107.79, and for the lesion site 167.91. MPR TRA CE for the normal site was 140.23 and for the lesion site 183.19, showing significant difference (p<0.050), and post-experiment analysis shows that there was a difference in SNR only on the lesion sites for Pre FLAIR and Post FLAIR (p<0.050). There was no difference in SNR between the normal site and lesion site for Post FLAIR and MPR TRA CE, indicating no effect from the contrast media (p>0.050). Conclusions: This experiment shows that Post FLAIR has a higher contrast than Pre FLAIR, and a higher SNR for lesions, It was not not statistically significant and MPR TRA CE but CNR came out high. Inspection of post-contrast which is used in a high magnetic field is frequently used images of 3D T1 but, since the signal of the contrast medium and the blood flow is included, this method can be diagnostic accuracy is reduced, it is believed that when used in combination with Post FLAIR, and that can provide video information added to the diagnosis of brain metastases.

  • PDF

Recent research activities on hybrid rocket in Japan

  • Harunori, Nagata
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2011년도 제36회 춘계학술대회논문집
    • /
    • pp.1-2
    • /
    • 2011
  • Hybrid rockets have lately attracted attention as a strong candidate of small, low cost, safe and reliable launch vehicles. A significant topic is that the first commercially sponsored space ship, SpaceShipOne vehicle chose a hybrid rocket. The main factors for the choice were safety of operation, system cost, quick turnaround, and thrust termination. In Japan, five universities including Hokkaido University and three private companies organized "Hybrid Rocket Research Group" from 1998 to 2002. Their main purpose was to downsize the cost and scale of rocket experiments. In 2002, UNISEC (University Space Engineering Consortium) and HASTIC (Hokkaido Aerospace Science and Technology Incubation Center) took over the educational and R&D rocket activities respectively and the research group dissolved. In 2008, JAXA/ISAS and eleven universities formed "Hybrid Rocket Research Working Group" as a subcommittee of the Steering Committee for Space Engineering in ISAS. Their goal is to demonstrate technical feasibility of lowcost and high frequency launches of nano/micro satellites into sun-synchronous orbits. Hybrid rockets use a combination of solid and liquid propellants. Usually the fuel is in a solid phase. A serious problem of hybrid rockets is the low regression rate of the solid fuel. In single port hybrids the low regression rate below 1 mm/s causes large L/D exceeding a hundred and small fuel loading ratio falling below 0.3. Multi-port hybrids are a typical solution to solve this problem. However, this solution is not the mainstream in Japan. Another approach is to use high regression rate fuels. For example, a fuel regression rate of 4 mm/s decreases L/D to around 10 and increases the loading ratio to around 0.75. Liquefying fuels such as paraffins are strong candidates for high regression fuels and subject of active research in Japan too. Nakagawa et al. in Tokai University employed EVA (Ethylene Vinyl Acetate) to modify viscosity of paraffin based fuels and investigated the effect of viscosity on regression rates. Wada et al. in Akita University employed LTP (Low melting ThermoPlastic) as another candidate of liquefying fuels and demonstrated high regression rates comparable to paraffin fuels. Hori et al. in JAXA/ISAS employed glycidylazide-poly(ethylene glycol) (GAP-PEG) copolymers as high regression rate fuels and modified the combustion characteristics by changing the PEG mixing ratio. Regression rate improvement by changing internal ballistics is another stream of research. The author proposed a new fuel configuration named "CAMUI" in 1998. CAMUI comes from an abbreviation of "cascaded multistage impinging-jet" meaning the distinctive flow field. A CAMUI type fuel grain consists of several cylindrical fuel blocks with two ports in axial direction. The port alignment shifts 90 degrees with each other to make jets out of ports impinge on the upstream end face of the downstream fuel block, resulting in intense heat transfer to the fuel. Yuasa et al. in Tokyo Metropolitan University employed swirling injection method and improved regression rates more than three times higher. However, regression rate distribution along the axis is not uniform due to the decay of the swirl strength. Aso et al. in Kyushu University employed multi-swirl injection to solve this problem. Combinations of swirling injection and paraffin based fuel have been tried and some results show very high regression rates exceeding ten times of conventional one. High fuel regression rates by new fuel, new internal ballistics, or combination of them require faster fuel-oxidizer mixing to maintain combustion efficiency. Nakagawa et al. succeeded to improve combustion efficiency of a paraffin-based fuel from 77% to 96% by a baffle plate. Another effective approach some researchers are trying is to use an aft-chamber to increase residence time. Better understanding of the new flow fields is necessary to reveal basic mechanisms of regression enhancement. Yuasa et al. visualized the combustion field in a swirling injection type motor. Nakagawa et al. observed boundary layer combustion of wax-based fuels. To understand detailed flow structures in swirling flow type hybrids, Sawada et al. (Tohoku Univ.), Teramoto et al. (Univ. of Tokyo), Shimada et al. (ISAS), and Tsuboi et al. (Kyushu Inst. Tech.) are trying to simulate the flow field numerically. Main challenges are turbulent reaction, stiffness due to low Mach number flow, fuel regression model, and other non-steady phenomena. Oshima et al. in Hokkaido University simulated CAMUI type flow fields and discussed correspondence relation between regression distribution of a burning surface and the vortex structure over the surface.

  • PDF

고대(古代) 마애삼존불(磨崖三尊佛)에서 찾는 삼재(三才)와 부등변삼각(不等邊三角)의 미학(美學) - 서산마애삼존불의 형식미를 중심으로 - (Aesthetics of Samjae and Inequilateral Triangle Found in Ancient Triad of Buddha Carved on Rock - Centering on Formative Characteristics of Triad of Buddha Carved on Rock in Seosan -)

  • 노재현;이규완;장일영;고여빈
    • 한국전통조경학회지
    • /
    • 제28권3호
    • /
    • pp.72-84
    • /
    • 2010
  • 본 연구는 서산마애삼존불을 중심으로 삼국시대 조성된 마애삼존불상 조형에 담겨진 비례미 등 구성적 원리가 어떻게 표현되고 있는지를 확인함으로써 전통 석조 방식의 하나인 삼존석조의 구축 및 응용을 위한 기초자료 구축을 모색하였다. 총 17개 마애삼존불의 크기 및 비율 분석 결과, 본존불의 평균 전고는 2.96m, 우협시는 2.19m, 좌협시는 2.16m였다. 이에 따른 높이비는 100:75:75로 좌우 대칭균형의 관계를 보였고, 좌우협시의 면적비는 13.4:16.7 로 우협시의 면적비가 높았다. 서산마애삼존불은 용현계곡의 삼불교를 건너 인암(印岩) 바위에 새겨져 있으며, 좌향은 방위각 $S47^{\circ}E$로 측정되었다. 이는 예배자의 눈부심을 차단하면서 햇빛의 방향에 따른 불상의 이미지 변화와 미감을 노린 것으로 판단된다. 서산마애불의 도상적 특징은 반가상과 봉지보주형 보상입상을 협시도 하고 있으며, 좌우비대칭형의 삼존 구성임에도 불구하고 동일한 선과 형태가 반복되는 가운데 통일성을 보임으로서 안정된 시각적 균형을 보이고 있다. 특히 서산마애삼존불의 경우, 본존불과 좌협시 그리고 우협시의 전고는 각각 2.80m, 1.66m, 1.70m였다. 좌우협시불의 높이비는 0.60:0.62로 거의 대등한 반면 면적비는 28.8:25.2로 보다 큰 차이를 보여 평면상의 면적비가 삼재미적 비례에 더욱 근접한 것으로 파악되었다. 광배 중심의 사윗각비는 88:44:48로 직각에 가까운 반면 연화좌 중심 사윗각의 비는 127:30:23으로 측정됨으로서 둔각에 가까운 부등변삼각형의 형태를 보였다. 따라서 서산마애삼존불의 상부와 하부는 직각과 둔각의 부등변삼각형의 각도 비례를 통한 대응적 관계를 유지하는 가운데 안정적 비례감을 취하고 있다. 상반부의 거리비는 0.51:0.36:0.38인 반면 하반부의 거리비는 0.53:0.33:0.27로 보다 부등변삼각형에 가까운 모습을 보이면서 상하 좌우대칭의 비대칭균형을 이루고 있다. 서산마애삼존불을 대상으로 삼재미의 관계를 살펴본 결과, 길이비 보다는 면적비나 삼각도형을 이루는 각도비가 더욱 두드러져 나타났다. 각 불상 상호간의 높이 및 면적비 못지않게 상부 광배와 하부 연화좌를 중심으로 형성되는 부등변삼각이 이루는 구도는 삼재간의 구성적 아름다움을 배가시키는 매우 중요한 내부적 동인이 되고 있다.

나선형 토모테라피 방사선치료의 환자별 품질관리를 위한 라디오크로믹 필름 및 Dosimetry CheckTM의 성능평가 (Performance Evaluation of Radiochromic Films and Dosimetry CheckTM for Patient-specific QA in Helical Tomotherapy)

  • 박수연;채문기;임준택;권동열;김학준;정은아;김종식
    • 대한방사선치료학회지
    • /
    • 제32권
    • /
    • pp.93-109
    • /
    • 2020
  • 목 적: 나선형 토모테라피 방사선치료를 위한 환자별 품질관리용 라디오크로믹 필름 및 3차원 분석시스템인 Dosimetry CheckTM (DC, MathResolutions, USA)의 성능평가를 시행하였다. 대상 및 방법: 인체모형팬톰(Anderson Rando Phantom, USA)을 이용하여 위치 변이가 있는 3가지 형태의 복부 종양(130.6㎤), 복막 후면 종양(849.0㎤) 및 전 복부 전이 종양(3131.0㎤)을 모델링하였다. 조사면 고정너비(field width, FW)를 2.5-cm, 5.0-cm, 피치(pitch) 0.287, 0.43으로 하여 부위별 4개씩(plan01-plan04), 총 12개의 비교용 치료계획을 수립하였다. 이온전리함(1D)과 라디오크로믹 필름(Gafchromic EBT3, Ashland Advanced Materials, USA)을 치즈팬톰 내 삽입하는 방법(2D)과 빔 플루언스 로그정보를 이용하여 CT영상 위에 선량을 3차원으로 재구성하는 방식의 DC측정을 진행하였다. 스레드효과(thread effect)를 분석을 위해 리플(ripple) 진폭(%)를 계산하였고, 선량 분포의 패턴 분석을 위해 감마인덱스 분석(DD: 3%/DTA: 3mm, 합격 문턱 값: 95%)을 수행하였다. 결 과: 리플 진폭 측정 결과 복막 후면 종양이 평균 23.1%로 가장 높았다. 라디오크로믹 필름의 분석결과, 절대 선량 평균 1.0±0.9%, 감마인덱스분석 평균 96.4±2.2%로 95% 이상 통과하였으나 전 복부 전이 종양과 같이 넓은 부위 평가에 범위의 제한적이었다. 인체모형팬톰에 적용한 DC 분석결과 FW가 5.0-cm인 세 부위의 2D 및 3D 플랜 평균이 91.8±6.4%였다. 세 단면 및 선량 프로파일 분석을 통해 복막 후면 및 전 복부 종양 표적 전체 영역에 분석이 가능하였고, 선량-용적 히스토그램을 통한 계획 선량 대 측정의 선량 오차가 FW 및 pitch에 따라 커지는 것을 확인하였다. 결 론: DC측정방법은 별도의 측정기 없이 조사 중 측정된 빔 플루언스 로그정보만으로 3차원 환자 영상 데이터 위에 선량 오류를 구현할 수 있고 종양의 위치나 크기에 제한이 없어 크고 불규칙한 종양의 나선형 토모테라피의 치료 시 환자별 품질관리 성능이 매우 우수하며 활용도가 높을 것으로 생각한다.

옥천대(沃川帶) 우라늄광층(鑛層)의 구조규제(構造規制) 및 지구화학적(地球化學的) 특성연구(特性硏究) (Lithologic and Structural Controls and Geochemistry of Uranium Deposition in the Ogcheon Black-Slate Formation)

  • 이대성;윤석규;이종혁;김정택
    • 자원환경지질
    • /
    • 제19권spc호
    • /
    • pp.19-41
    • /
    • 1986
  • Structural, radioactive, petrological, petrochemical, mineralogical and stable isotopic study as well as the review of previous studies of the uranium-bearing slates in the Ogcheon sequence were carried out to examine the lithological and structural controls, and geochemical environment in the uranium deposition in the sequence. And the study was extended to the coal-bearing formation (Jangseong Series-Permian) to compare the geochemical and sedimentologic aspects of uranium chemistry between Ogcheon and Hambaegsan areas. The results obtained are as follows: 1. The uranium mineralization occurs in the carbonaceous black slates of the middle to lower Guryongsan formation and its equivalents in the Ogcheon sequence. In general, two or three uranium-bearing carbonaceous beds are found with about 1 to 1.5km stratigraphic interval and they extend from Chungju to Jinsan for 90km in distance, with intermittent igneous intrusions and structural Jisturbances. Average thickness of the beds ranges from 20 to 1,500m. 2. These carbonaceous slate beds were folded by a strong $F_1$-fold and were refolded by subsequent $F_1$-fold, nearly co-axial with the $F_1$, resulting in a repeated occurrence of similar slate. The carbonaceous beds were swelled in hing zones and were shrinked or thined out in limb by the these foldings. Minor faulting and brecciation of the carbonaceous beds were followed causing metamorphism of these beds and secondary migration and alteration of uranium minerals and their close associations. 3. Uranium-rich zones with high radioactive anomalies are found in Chungju, Deogpyong-Yongyuri, MiwonBoun, Daejeon-Geumsan areas in the range of 500~3,700 cps (corresponds to 0.017~0.087%U). These zones continue along strike of the beds for several tens to a few hundred meters but also discontinue with swelling and pinches at places that should be analogously developed toward underground in their vertical extentions. The drilling surveyings in those area, more than 120 holes, indicate that the depth-frequency to uranium rich bed ranging 40~160 meter is greater. 4. The features that higher radioactive anomalies occur particularly from the carbonaceous beds among the argillaceous lithologic units, are well demonstrated on the cross sections of the lithology and radioactive values of the major uranium deposits in the Ogcheon zone. However, one anomalous radioactive zone is found in a l:ornfels bed in Samgoe, near Daejeon city. This is interpreted as a thermal metamorphic effect by which original uranium contents in the underlying black slate were migrated into the hornfels bed. 5. Principal minerals of the uranium-bearing black slates are quartz, sericite, biotite and chlorite, and as to chemical composition of the black slates, $Al_2O_3$ contents appear to be much lower than the average values by its clarke suggesting that the Changri basin has rather proximal to its source area. 6. The uranium-bearing carbonaceous beds contain minor amounts of phosphorite minerals, pyrite, pyrrhotite and other sulfides but not contain iron oxides. Vanadium. Molybdenum, Barium, Nickel, Zirconium, Lead, Cromium and fixed Carbon, and some other heavy metals appear to be positive by correlative with uranium in their concentrations, suggesting a possibility of their genetic relationships. The estimated pH and Eh of the slate suggests an euxenic marine to organic-rich saline water environment during uranium was deposited in the middle part of Ogcheon zone. 7. The Carboniferous shale of Jangseong Series(Sadong Series) of Permian in Hambaegsan area having low radioactivity and in fluvial to beach deposits is entirely different in geochemical property and depositional environment from the middle part of Ogcheon zone, so-called "Pibanryong-Type Ogcheon Zone". 8. Synthesizing various data obtained by several aspects of research on uranium mineralization in the studied sequence, it is concluded that the processes of uranium deposition were incorporated with rich organic precipitation by which soluble uranyl ions, $U{_2}^{+{+}}$ were organochemically complexed and carried down to the pre-Ogcheon sea bottoms formed in transitional environment, from Red Sea type basin to Black Sea type basin. Decomposition of the organic matter under reducing conditions to hydrogen sulfide, which reduced the $UO{_2}^{+2}$ ions to the insoluble uranium dioxide($UO_2$), on the other side the heavy metals are precipitated as sulfides. 9. The EPMA study on the identification of uraninite and others and the genetic interpretation of uranium bearing slates by isotopic values of this work are given separately by Yun, S. in 1984.

  • PDF

고선량률 근접치료계획의 정도보증 프로그램 (Independent Verification Program for High-Dose-Rate Brachytherapy Treatment Plans)

  • 한영이;추성실;허승재;서창옥
    • Radiation Oncology Journal
    • /
    • 제21권3호
    • /
    • pp.238-244
    • /
    • 2003
  • 목적: 개별화되어 가는 고선량률 근접치료계획의 추세에 따라, 고성량률 근접치료계획의 절대적 선량과 상대적인 선량분포를 독립적으로 계산하여 환자의 해부영상 위에 겹쳐 표시할 수 있는 품질보증용 컴퓨터 프로그램을 개발한다. 대상 및 방법: 컴퓨터 프로그램은 먼저, 환자의 치료계획에서 계산된 선원의 위치, 각 위치에서의 조사시간, reference point에서의 선량, 치료계획이 실시된 날짜 등의 자료 입력을 필요로 한다. ICWG 권고 수식과 선원의 비등방성 표를 이용하여 $10\times12\times10\;(Cm^3)$의 공간에서 선량분포가 계산된 후 reference point에서의 선량이 자동적으로 치료계획의 결과와 비교된다. 모의치료의 영상이나 자기공명(Magnetic Resonance) 영상을 입력하고 사용자가 선택한 점을 수직으로 교차하는 3개의 평면에서 등선량곡선을 겹쳐서 보여준다. Gamma Med사의 Gam-madot (MDS Nordion, Germany)에서 표준 치료계획을 실행하여 정확성을 확인하였으며, Plato (Nucletron Cor-poration, The Netherlands)에서 실행된 9명의 환자치료계획과 비교하였다. 결과: 3개의 표준 치료계획에서 절대선량은 $2.8\%$ 내에서 일치하였으며 등 선량분포도 좋은 일치를 보였다. 9명의 환자에 대하여 시행된 치료계획과의 비교에서는 평균 $3.4\%$의 오차를 보였다. 결론: 개발된 컴퓨터 프로그램은 정확하고 신속하게 고선량률 치료환자의 치료계획의 정확성을 확인할 수 있게 해주며, 등선량 곡선을 환자의 해부적 영상에 결합할 수 있는 기능은 치료계획의 질을 높이는데 기여할 수 있을 것으로 기대된다.$39\%$), 복회음부 절제수술시 32건($97\%$), 측연의 경우 32건($97\%$), 후연의 경우 32건($97\%$), 그리고 전연의 경우 16건($45\%$)에서 부합되는 것으로 나타났다. 결론: 직장암의 수술 후 방사선치료 시 적절한 방사선치료 조사영역의 결정을 위하여 표준적인 조사영역을 제시 하였으나 개별 환자의 병변 위치와 진행상태, 수술 소견 등에 따라 적절한 변형은 필수적이라 하겠다. 이 권고안의 임상적 타당성은 향후 시행될 Patterns of Care 연구를 통하여 증명하는 것이 필요하겠다.정가능하고, 폐에 조사되는 방사선 양도 줄일 수 있었다.저부까지 거리 차이는 종양 크기가 4 cm 미만인 경우는 5.3 mm였으나 4 cm 이상일 때는 19.4 mm로 현저한 변화를 보였다. 자궁경관 굴곡각은 60세 미만인 경우 60세 이상보다 8$^{\circ}$ 정도 더 변화가 있었고, 종양 크기가 4 cm 이상일 때 미만일 때보다 2배 이상 굴곡 변화가 있었다. 결론: 자궁경부암 환자에서 근치적 방사선치료 시 치료에 따른 자궁 크기 및 위치 변화가 다양하고 개별적으로 예측하기 쉽지 않으므로, 특히, 60세 미만이거나 종양 크기가 4 cm 이상인 경우, 삼차원입체조형치료나 강도변조 방사선치료를 이용한 근치적 방사선치료 시 치료 중 개별환자의 계획용표적체적의 변화를 반드시 고려해야 한다고 생각한다.량체적히스토그램, Lymankutcher 모델에 의한 정상조직합병증발생률 및 기타 선량통계값 등 모든 면에 있어서 우월성을 확인할 수 있었다. 향후 이러한 결과가 임상에서 실질적인 합병증 발생률 감소와 잘 연계되는지 계속적인 추적관찰 및

GFRP로 구속된 원형단면 콘크리트 단주의 강도 및 변형 능력 (Strength and Deformation Capacities of Short Concrete Columns with Circular Section Confined by GFRP)

  • 조순호
    • 콘크리트학회논문집
    • /
    • 제19권1호
    • /
    • pp.121-130
    • /
    • 2007
  • 본 연구에서는 FRP(fiber reinforced polymer) 합성재료에 의하여 콘크리트를 구속할 시 예상되는 콘크리트의 강도 및 변형 능력의 향상 효과를 알아보기 위하여 섬유 량 혹은 방향, 단부하중조건에 따른 wrap 혹은 튜브형의 구속형태, 반원형 쉘 및 수직 이음부의 유무에 따른 연속 및 불연속 구속 형태 등을 주요 변수로 한 총 36개의 원형단주 시험체에 대하여 단조가력 실험을 수행하였다. 여러 구속 방법에 따른 FRP의 파단변형률에 대하여서도 주의를 가지고 조사하였다. 구속된 콘크리트의 최대 강도 및 변형률을 산정하기 위하여 기존에 제시된 다양한 배경의 예측 식들에 대하여 검토하였으며, 이들에 의한 예측치와 실험치를 비교, 분석하였다. 구속되지 알은 콘크리트와 비교하여, CW 및 CF형은 매우 큰 강도 및 변형능력의 증가를 나타냈으며, 수직 이음부를 갖는 CP형은 폭발적으로 파괴하였으며, 보다 작은 강도 및 변형능력의 증가가 관측되었다. 대체로, 모든 시험체는 2선 선형관계의 응력-변형률 거동을 나타냈으며, 후반부의 변형경화 정도는 구속매체의 강성에 따라 결정되었다. 모든 시험체에서 관측된 FRP의 파단변형률은 인장시험편으로부터 획득한 극한변형률보다 정도에 따라서는 매우 작았다. 대체로, 기존 예측식들은 본 실험의 최대 강도 및 변형률을 과대평가 하였으며, 변형률 예측은 매우 산란된 분포를 나타냈다. 또한, 본 연구의 실험 결과에 근거하여 구속 콘크리트의 최대 강도 및 변형률을 보다 정확하게 예측할 수 있는 설계 목적의 단순식을 제안하였다. 강도식은 모어-쿨롱 파괴 기준을 사용하여 유도하였으며, 변형률식은 비구속 콘크리트를 주요 영향 요소로 포함하여 실험 결과를 fitting하였다./TEX> = 분광광도법으로 측정한 점토함량(%); $x_2$ = 유기물 함량($g{\cdot}kg^{-1})$)이었으며, 상관계수는 $0.984^{**}$로 두 방법사이에 높은 상관관계가 있는 것으로 조사되었다. 여기서 유도된 회귀방정식을 프로그램화하여 컴퓨터나 분석기기에 입력시 시간과 공간을 절약하고 신속하고 정확하게 점토함량을 분석할 수 있을 것으로 판단된다.119>잠118>잠107>잠117>잠113 순이었고, 웅견층중에서는 잠114>잠108>잠120>잠117>잠118>잠107>잠119>잠119>잠113 순이었다. 자견층 비율에서는 광의의 귀전력이 협의의 귀전력보다 컸고, 웅견층 비율에서는 같았다, 견층 비율에서는 일반조합 능력은 크게 나타났으나, 특정조합 능력과 상반조직 능력은 나타나지 않았다. 자견층 비율에서 교배친의 우성효과는 컸다. 자견층 비율에서는 교배친의 우성효과는 적었다. 자웅견층 비율의 잡종 강세는 적게 나타났다. 환경변이와 상가적 작계는 자웅견층 비율에서는 크게 나타났다. 우성의 방향은 자견층 비율에서는 정의 방향으로 우성 귀전자가 크게 작용하였으며, 자견층 비율에서는 정의 방향으로 우성 귀전자가 부분적으로 작용하였다. 교배친의 자견층 비율의 우성순서는 잠117>잠114>잠108>잠120>잠118>잠119>잠107>잠113 순이었고, 자견층 비율에서는 잠114>잠117>잠108>잠118>잠107>잠119>잠113>잠120의 순이었다.지방산의 조성이 많은 차이를 보였다.{2+}$ 26 및 $Na^+$ 26 mg $L^{-1}$이었다. 양액 재배 후 버려지는 폐양액 중의 무기성분 함량은

악성 골 종양의 초기 증상 (Initial Symptoms of Malignant Bone Tumors)

  • 오주한;이상훈;서성욱;이호규;김한수
    • 대한골관절종양학회지
    • /
    • 제9권1호
    • /
    • pp.18-23
    • /
    • 2003
  • 목적: 골 육종, 연골 육종은 흔한 질환이 아니므로, 일차 진료 현장에서 명확한 진단이 신속히 이루어지지 않고, 진단의 지연이나 오진으로 인해 문제를 야기할 수 있다. 따라서, 상기 질환에 대한 초기 증상과 임상적 특징을 조사하여 이를 확인하고, 조기 진단에 도움을 주고자한다. 대상 및 방법: 본원에서 진단된 골 육종이나 연골 육종 환자로, 기록 검토와 설문지 조사가 가능한 139명을 대상으로 하였다. 골 육종 환자가 108명, 연골 육종이 31명이었고, 남자가 86명, 여자가 53명이었으며, 평균 연령은 골 육종이 20.2세, 연골 육종이 42.4세이었다. 결과: 병원을 방문하게 된 초기 증상은 두 질병 군 모두에서 동통이 가장 많았는데, 골 육종은 101명(93.5%), 연골 육종은 19명(61.3%)이었다. 이들 중 골 육종의 49명(48.5%), 연골 육종의 1명(5.3%)에서 통증이 외상과 관련되어 시작되었으며, 야간 동통이 골 육종의 77명(76.2%), 연골 육종의 11명(57.8%)에서 있었다. 처음 방문한 진료 기관에서 악성 골 종양으로 진단된 경우는 골 육종에서는 66명(61.1%), 연골 육종에서 20명(64.5%)이었고, 오진된 경우는 골 육종에서는 골절로 본 경우가 18명(16.7%)으로 가장 많았으며, 연골 육종에서는 골 감염으로 본 경우가 6명(19.4%)으로 가장 많았다. 초진 시에 방사선 촬영을 시행한 경우 골 육종과 연골 육종 모두에서 진단율이 유의하게 높았고(p=0.009, p=0.014), 성인 군에서의 진단율이 높았다(p=0.037). 연골 육종에서 골 육종보다 환자와 의사에 의한 지연이 모두 길었다. 진단의 의사 지연을 길게 하는 요소로는 초진 시에 단순 방사선 사진을 촬영하지 않는 것과 골반 등 축성골에 종양이 위치하는 것이었고, 외상과 미성년 환자는 진단의 환자 지연을 단축시킬 수 있는 요소로 파악되었다. 결론: 악성 골 종양의 조기 진단을 위해서는 외상이나 야간 동통 등의 병력 청취를 소홀히 하지 않아야 할 것이며, 초진시의 단순 방사선 촬영과 주기적인 경과 관찰 및 방사선 사진의 비교 등으로 조기 진단의 정확성에 힘써야 할 것이다.

  • PDF

입체적횡다증회전조사를 병합한 방사선수술의 새로운 접근 : 포톤나이프 (A New Approach with Combined Stereotactic Trans-multiarc Beams for Radiosurgery Based on the Linear Accelerator : Photon Knife)

  • 최태진;김진희;김옥배
    • Radiation Oncology Journal
    • /
    • 제14권2호
    • /
    • pp.149-158
    • /
    • 1996
  • 목적 : 선형가속기의 광자선을 이용한 두개내 소병변의 방사선수술에서 다중회전조사와 횡다중회전조사를 병용한 방사선 수술방법을 개발하고, 컴퓨터단층영상을 재구성한 방사선수술계획을 통해 선량분포를 비교하여 병변이외 정상조직의 선량을 줄이기 위한 선량변수를 구하였다. 대상 및 방법 : 선형가속기 6 MV 광자선을 이용하여 치료대 각과 선원지지체 회전 및 환자체위변위를 이용한 입체적 다중 및 횡다중회전조사를 조사하여 선량분포를 비교하였다. 입체적 선량분포와 횡단면, 시상면 및 관상면 치료대 영상재구성의 선량분포는 본 대학에서 개발한 방사선수술기구 및 소프트웨어 (Photon Knife)를 통해 이루어졌다. 입체적 다중회전조사에 의해 얻은 선량은 치료대 각이 20, 50, 120, 160 도, 각각의 선원지지체 회전각은 20-160도이며, 다중회전조사의 치료대각 30, 150도와 횡다중회전조사의 치료대각 30, 150도에 선원 회전각 20-160도를 입체조사하여 비교하였다. 결과 : 선형가속기를 이용한 방사선수술선량분포는 동일 콜리메이터에서도 치료대와 선원지지체 각에 따라 크게 변하였다. 입체횡다중회전조사를 시행한 경우 표적을 중심으로 전후방향의 선량분포는 다중회전조사만을 사용한 경우보다 선량기울기가 증가하여 정상뇌조직의 손상을 더 감소시킬 수 있음을 알 수 있었으며, 병변주위의 치명장기 위치에 따라 방사선 회전 방향을 적절히 정할 수 있다. 방사선수술의 입체선량과 주위 장기 및 표적의 On-Target 입체화는 방사선수술의 정확성, 복수개의 표적중심결정과 주위정상장기의 선량포함범위를 비교적 정확하게 보여줌을 알 수 있다. 결론 : 방사선수술선량계획의 입체화는 선량과 표적 및 주위장기의 선량범위를 입체적으로 정할 뿐만 아니라, 표적의 모양이 불규칙형일 때는 복수개의 표적중심결정에 필수적임을 알 수 있었다. 다중회전조사와 횡다중회전조사를 병합한 방사선수술은 표적주위의 치명정상장기의 손상을 줄이기 위해 총회전각의 변화없이 치명장기에 도달될 선량을 줄일 수 있으며, 25 mm 직경의 콜리메이터를 사용한 선량분포는 $80-50\%$의 간격이 $1.1\~3.0 mm$, $90\~50\%$$2.0\~3.0mm$를 나타내었다.

  • PDF

A Computed Tomography-Based Anatomic Comparison of Three Different Types of C7 Posterior Fixation Techniques : Pedicle, Intralaminar, and Lateral Mass Screws

  • Jang, Woo-Young;Kim, Il-Sup;Lee, Ho-Jin;Sung, Jae-Hoon;Lee, Sang-Won;Hong, Jae-Taek
    • Journal of Korean Neurosurgical Society
    • /
    • 제50권3호
    • /
    • pp.166-172
    • /
    • 2011
  • Objective : The intralaminar screw (ILS) fixation technique offers an alternative to pedicle screw (PS) and lateral mass screw (LMS) fixation in the C7 spine. Although cadaveric studies have described the anatomy of the pedicles, laminae, and lateral masses at C7, 3-dimensional computed tomography (CT) imaging is the modality of choice for pre-surgical planning. In this study, the goal was to determine the anatomical parameter and optimal screw trajectory for ILS placement at C7, and to compare this information to PS and LMS placement in the C7 spine as determined by CT evaluation. Methods : A total of 120 patients (60 men and 60 women) with an average age of $51.7{\pm}13.6$ years were selected by retrospective review of a trauma registry database over a 2-year period. Patients were included in the study if they were older than 15 years of age, had standardized axial bone-window CT imaging at C7, and had no evidence of spinal trauma. For each lamina and pedicle, width (outer cortical and inner cancellous), maximal screw length, and optimal screw trajectory were measured, and the maximal screw length of the lateral mass were measured using m-view 5.4 software. Statistical analysis was performed using Student's t-test. Results : At C7, the maximal PS length was significantly greater than the ILS and LMS length (PS, $33.9{\pm}3.1$ mm; ILS, $30.8{\pm}3.1$ mm; LMS, $10.6{\pm}1.3$; p<0.01). When the outer cortical and inner cancellous width was compared between the pedicle and lamina, the mean pedicle outer cortical width at C7 was wider than the lamina by an average of 0.6 mm (pedicle, $6.8{\pm}1.2$ mm; lamina, $6.2{\pm}1.2$ mm; p<0.01). At C7, 95.8% of the laminae measured accepted a 4.0-mm screw with a 1.0 mm of clearance, compared with 99.2% of pedicle. Of the laminae measured, 99.2% accepted a 3.5-mm screw with a 1.0 mm clearance, compared with 100% of the pedicle. When the outer cortical and inner cancellous height was compared between pedicle and lamina, the mean lamina outer cortical height at C7 was wider than the pedicle by an average of 9.9 mm (lamina, $18.6{\pm}2.0$ mm; pedicle, $8.7{\pm}1.3$ mm; p<0.01). The ideal screw trajectory at C7 was also measured ($47.8{\pm}4.8^{\circ}$ for ILS and $35.1{\pm}8.1^{\circ}$ for PS). Conclusion : Although pedicle screw fixation is the most ideal instrumentation method for C7 fixation with respect to length and cortical diameter, anatomical aspect of C7 lamina is affordable to place screw. Therefore, the C7 intralaminar screw could be an alternative fixation technique with few anatomic limitations in the cases when C7 pedicle screw fixation is not favorable. However, anatomical variations in the length and width must be considered when placing an intralaminar or pedicle screw at C7.