• 제목/요약/키워드: Three-axial

검색결과 1,401건 처리시간 0.024초

소형 수직형 축류 펌프를 위한 축방향 자기 부상 모터 (An Axial-type Self-bearing Motor for Small Vertical Axial-flow Pump)

  • 김승종
    • 한국소음진동공학회논문집
    • /
    • 제11권6호
    • /
    • pp.223-232
    • /
    • 2001
  • Aiming at a small axial pump with a levitated rotor, an axial-type self-bearing motor is presented, which has a rotor wish four permanent magnets and two stators with two-pole three-phase windings. In this system, only the axial motion of rotor is actively controlled by two opposite self-bearing motors just like in the case of an axial magnetic bearing, while the other motions are passively stable. For rotation, It follows the theory of a four-pole three-phase synchronous motor. This paper Introduces schemes for design and control of the self-bearing motor and shows some experimental results to Prove the feasibility of application for the axial Pump.

  • PDF

냉장고용 소형 축류홴의 통계학적 3차원 난류유동 특성에 관한 연구 (A Study on the Three Dimensional Statistical Turbulent Flow Characteristics Around a Small-Sized Axial Fan for Refrigerator)

  • 김장권
    • 대한기계학회논문집B
    • /
    • 제25권6호
    • /
    • pp.819-828
    • /
    • 2001
  • The operating point of a small-sized axial fan is strongly dependent upon the system resistance. Therefore, the turbulent flow characteristics around a small-sized axial fan may change significantly according to the operating point. This study represents three-dimensional turbulent flow characteristics around a small-sized axial fan measured at the ideal design point $\phi$=0.25, which is equivalent to the maximum total efficiency point, by using three dimensional fiber-optic type LDA system. This LDA system is composed of a 5 W Argon-ion laser, two optics in back-scatter mode, three BSAs, a PC, and a three-dimensional automatic traversing system. A kind of paraffin fluid is used to supply particles by means of fog generator. Mean velocity profiles downstream of a small-sized axial fan along the radial distance show that the streamwise and the tangential components exist in a predominant manner, while the radial component has a small scale distribution and shows the inflection which its flow direction is inward or outward. Moreover, the turbulent intensity profiles show that the radial component exists the most greatly among turbulent energies.

엇회전식 축류팬의 3 차원 비정상 유동에 관한 실험적 연구 (Experimental Study on the Three Dimensional Unsteady Flow in a Counter Rotating Axial Flow Fan)

  • 박현수;조이상;강현구;조진수
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.822-827
    • /
    • 2003
  • Experiments were done for the three dimensional unsteady flow in a counter rotating axial flow fan under stable operating condition. Flow fields in a counter rotating axial flow fan were measured at cross-sectional planes of the upstream and downstream of each rotor. Cross sectional flow patterns were investigated through the acquired data by the $45^{\circ}$ inclined hot-wire. Flow characteristics such as tip vortex, secondary flow and tip leakage flow were confirmed through axial, radial and tangential velocity vector plot. Swirl velocity, which was generated by the front rotor, was recovered in the form of static pressure rise by the rear rotor except for hub and tip regions.

  • PDF

엇회전식 축류팬의 3차원 비정상 유동에 관한 실험적 연구 (Experimental Study on the Three Dimensional Unsteady Flow in a Counter-Rotating Axial Flow Fan)

  • 박현수;조이상;조진수
    • 대한기계학회논문집B
    • /
    • 제28권9호
    • /
    • pp.1005-1014
    • /
    • 2004
  • Experiments were done for the three dimensional unsteady flow in a counter-rotating axial flow fan under peak efficiency operating condition. Flow fields in a counter rotating axial flow fan were measured at cross-sectional planes of the upstream and downstream of each rotor. Cross sectional flow patterns were investigated through the acquired data by the 45$^{\circ}$ inclined hot-wire. Flow characteristics such as tip vortex, secondary flow and tip leakage flow were confirmed through axial, radial and tangential velocity vector plot. It has been found that the radial and tangential velocity components disappeared, while the axial velocity component highly increased as soon as the tip vortex was generated. It has been observed that secondary flow and turbulence intensity which were increased by the front rotor were dissipated passing through the rear rotor. As the result the energy loss of the counter rotating axial flow fan decreased at the downstream of rear rotor. Also, it has been verified that tip vortex pattern of the rear rotor was dampened because the tip vortex generated by front rotor was mixed with that of the rear rotor.

소형 축류홴의 난류유동 특성치에 대한 LDA 측정 (LDA Measurements on the Turbulent Flow Characteristics of a Small-Sized Axial Fan)

  • 김장권
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 추계학술대회논문집B
    • /
    • pp.371-376
    • /
    • 2001
  • The operating point of a small-sized axial fan for refrigerator is strongly dependent upon the system resistance. Therefore, the turbulent flow characteristics around a small-sized axial fan may change significantly according to the operating point. This study represents three-dimensional turbulent flow characteristics around a small-sized axial fan measured at the four operating points such as $\varphi=0.1$, 0.18, 0.25 and 0.32 by using fiber-optic type LDA system. This LDA system is composed of a 5 W Argon-ion laser, two optics in back-scatter mode, three BSA's, a PC, and a three-dimensional automatic traversing system. A kind of paraffin fluid is utilized for supplying particles by means of fog generator. Mean velocity profiles downstream of a small-sized axial fan along the radial distance show that both the streamwise and the tangential components exist predominantly in downstream except $\varphi=0.1$ and have a maximum value at the radial distance ratio of about 0.8, but the radial component, which its velocity is relatively small, is acting role that only turns flow direction to the outside or the central part of axial fan. Moreover, all of the velocity components downstream at $\varphi=0.1$ show much smaller than those upstream due to the static pressure rise at the low-flowrate region.

  • PDF

엇회전식 축류팬의 비정상 유동특성에 관한 실험적 연구 (Experimental Study on the Unsteady Flow Characteristics of the Counter-Rotating Axial Flow Fan)

  • 조이상;최현민;강정식;조진수
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2007년도 제29회 추계학술대회논문집
    • /
    • pp.305-310
    • /
    • 2007
  • 엇회전식 축류팬의 복잡한 유동특성을 이해하고 설계, 공력 해석 및 소음 특성 예측에 활용될 수 있는 3차원 비정상 유동장을 측정하였다. 엇회전식 축류팬의 3차원 비정상 유동장은 작동 영역인 설계점에서 $45^{\circ}$ 경사 열선을 이용하여 전단 동익의 전방, 전단 동익과 후단 동익 사이 그리고 후단 동익의 후방의 수직 유로 단면에서 측정되었다. 엇회전식 축류팬의 전단 동익과 후단 동익에 의해 발생되는 후류, 팁 와류 및 팁 누설 유동의 비정상 특성을 속도 벡터와 속도 윤곽을 통해 나타내었다.

  • PDF

아동들의 굴절이상에 따른 안축장과 황반두께, 망막신경섬유층 두께의 상관성연구 (Study of Correlation between Macular Thickness, Retina Nerve Fiber Layer Thickness and Axial Length according to Refractive Errors in Children)

  • 최형석;임현성
    • 대한시과학회지
    • /
    • 제20권4호
    • /
    • pp.421-429
    • /
    • 2018
  • 목적 : 굴절이상별 세 그룹으로 분류한 우리나라 아동들의 안축장과 빛간섭단층촬영(OCT)로 측정한 황반두께, 망막신경섬유층두께 사이의 상관성을 알아보고자 하였다. 방법 : 안질환이 없고 안과관련 수술 경험이 없는 아동 67명(134안)을 대상으로 원시, 정시, 근시 그룹으로 분류하였다. 황반부와 망막신경섬유층두께는 Cirrus HD-OCT를 이용하여 측정하였고, 안축장은 IOL Master를 이용하여 측정하였다. 결과 : 안축장은 근시, 정시, 원시그룹 순서로 길게 측정되었다(p<0.05). 중심부황반의 두께는 근시, 정시, 원시그룹 순서로 두껍게 측정되었다(p<0.05). 주변부황반부는위쪽, 코쪽, 아래쪽부분에서 근시그룹이 가장 얇았다(p<0.05).황반의 중심부 두께는 안축장과 양의 상관관계가 있었다(r=0.283, p<0.05). 주변부 황반의 두께는 모두 안축장과 음의 상관관계를 보였다. 귀쪽망막신경섬유층두께(Temporal RNFL Thickness)는 근시그룹이 가장 두꺼운 결과를 보였고,안축장과통계적으로 유의한 양의상관성이 나타났다(r=0.39, p<0.05). 위쪽과 코쪽, 아래쪽의 망막신경섬유층 두께는 안축장과 모두 음의 상관성을 나타냈다. 코쪽 부분의 두께는 통계적으로 유의하게 나타났다(r=-0.23, p<0.05). 결론 : 본 연구를 통해 우리나라 소아들의 OCT로 측정한 망막의 황반부의 두께, 망막신경섬유층의 두께와 안축장은 근시의 정도가 높을수록 안축장의 길이가 더 길게 측정되었으며, 굴절이상별 세 그룹에서 나타나는 차이점을 확인하였다.

대규모와 모사에 의한 3차원 소형축류홴의 운전부하에 따른 난류유동장 구조에 대한 연구 (A Study on the Structure of Turbulent Flow Fields According to the Operating Loads of Three-Dimensional Small-Size Axial Fan by Large Eddy Simulation)

  • 김장권;오석형
    • 동력기계공학회지
    • /
    • 제19권5호
    • /
    • pp.80-85
    • /
    • 2015
  • The unsteady-state, incompressible and three-dimensional large eddy simulation(LES) was carried out to analyze the structure of turbulent flow fields according to the operating loads of three-dimensional small-size axial fan(SSAF). LES shows the best prediction performance in comparison with any other Reynolds averaged Navier-Stokes(RANS) method because static pressure coefficients analysed by LES show a little bit larger than measurements including all flow coefficients. Also, it can be known that the wake of SSAF is divided into from axial flow to radial flow before and behind stall region according to the increase of static pressure through LES analysis.

1단 터빈에서 축간격 변화가 비정상 이차유동 및 성능에 미치는 영향 (The effects of axial spacing on the unsteady secondary and performance in one-stage axial turbine)

  • 박준영;백제현
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2002년도 학술대회지
    • /
    • pp.537-540
    • /
    • 2002
  • Flow through turbomachinery has a very complex structure and is intrinsically unsteady. Especially, recent design trend to turbomachinery with short axial spacing makes the flow extremely complex due to the interaction between stator and rotor. Therefore, it is very necessary to clearly understand the complex flow structure to obtain the high efficiency turbomachinery. So, in this paper, the effects of axial spacing on the unsteady secondary flow performance in the one stage turbine are investigated by three-dimensional unsteady flow analysis. The three-dimensional solver is parallelized using domain decomposition and Message Passing Interface(MPI) standard to overcome the limitation of memory and the CPU time in three-dimensional unsteady calculation. A sliding mesh interface approach has been implemented to exchange flow information between blade rows.

  • PDF

Dynamic PIV Measurement of Swirl Flow in a PC Fan

  • ARAMAKI Shinichiro;HAYAMI Hiroshi
    • 한국가시화정보학회:학술대회논문집
    • /
    • 한국가시화정보학회 2004년도 Proceedings of 2004 Korea-Japan Joint Seminar on Particle Image Velocimetry
    • /
    • pp.41-45
    • /
    • 2004
  • The dynamic particle image velocimetry (PIV) is consisted of a high frequency pulse laser, high speed cameras and a timing controller. The three velocity components of flow downstream of an axial flow fan for PC cooling system are measured using the dynamic PIV system. An Axial flow fan has seven blades of 72 mm in diameter. The rotating speed is 1800 rpm. The downstream flow is visualized by smoke particles of about $0.3-1\;{\mu}m$ in diameter. The three-dimensional instantaneous velocity fields are measured at three downstream planes. The swirl velocity component was diffused downstream and the change in time-mean vorticity distribution downstream was also discussed. The spatio-temporal change in axial velocity component with the blades passing is recognized by the instantaneous vector maps. And the dynamic behavior of vorticity moving with the rotating blades is discussed using the unsteady vorticity maps.

  • PDF