• Title/Summary/Keyword: Three-Level

Search Result 14,076, Processing Time 0.04 seconds

Three-Level Optimal Control of Nonlinear Systems Using Fast Walsh Transform (고속월쉬변환을 이용한 비선형 시스템의 3계층 최적제어)

  • Kim, Tai-Hoon;Shin, Seung-Kwon;Cho, Young-Ho;Lee, Han-Seok;Lee, Jae-Chun;Ahn, Doo-Soo
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.50 no.11
    • /
    • pp.505-513
    • /
    • 2001
  • This paper presents the new three-level optimal control scheme for the large scale nonlinear systems, which is based on fast walsh transform. It is well known that optimization for nonlinear systems leads to the resolution of a nonlinear two point boundary value problem which always requires a numerical iterative technique for their solution. However, Three-level costate coordination can avoid two point boundary condition in subsystem. But this method also has the defect that must solve high order differential equation in intermediate level. The proposed method makes use of fast walsh transform, therefore, is simple in computation because of solving algebra equation instead of differential equation.

  • PDF

Proper Numerical Scheme to Solve the Flow Past a Circular Cylinder with Time and Grid Size Variations (시간과 격자 크기 변화에 따른 원주후류해석의 경제적 수치기법)

  • Maeng, Joo-Sung;Kim, Yong-Dae;Choi, IL-Kon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.24 no.5
    • /
    • pp.652-659
    • /
    • 2000
  • The purpose of this study is to present the most effective numerical scheme to calculate the unsteady flows. In order to calculate the flow quantities of flow past a circular cylinder, Three-time level and five convective schemes are applied to unsteady and convective terms, respectively. The values obtained are compared with those from the existing experimental and numerical studies. At Reynolds numbers up to 160, time intervals can be expanded 10 times of Implicit Euler scheme using Three-time level method, and it is found that QUICK and CUI schemes work much stable than others even if less grid density conditions. The combination of Three-time level and QUICK scheme gives high resolutions for laminar unsteady problems with PC level.

Comparative Analysis of Efficiency and Power Density of Single-Phase and 3-Level Boost Converters for PV System (태양광 시스템용 단상 및 3-레벨 부스트 컨버터의 효율 및 전력밀도 비교 분석)

  • Kim, Chul-Min;Kim, Jong-Soo
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.25 no.2
    • /
    • pp.127-132
    • /
    • 2020
  • In this study, single-phase and three-level boost converters applied to the photovoltaic system were compared and analyzed in terms of efficiency and power density according to the input voltage and load conditions. For accurate analysis of efficiency, the losses in each device of the single-phase and three-level boost converters were derived using mathematical equations and simulations by using the PSIM thermal module. Then, the losses were compared with the efficiency confirmed through the actual experiments. Results confirmed that the efficiency and power density can be improved by applying the three-level boost converter to the system according to the selection of the switching frequency.

Three-Way Balanced Multi-level Semi Rotation Sampling Designs

  • Park, You-Sung;Choi, Jai-Won;Kim, Kee-Whan
    • Proceedings of the Korean Statistical Society Conference
    • /
    • 2002.05a
    • /
    • pp.19-24
    • /
    • 2002
  • The two-way balanced one-level rotation design has been discussed (Park, Kim and Choi, 2001), where the two-way balancing is done on interview time in monthly sample and rotation group. We extend it to three-way balanced multi-level design under the most general rotation system. The three-way balancing is accomplished on interview time not only in monthly sample and rotation group but also in recall time. We present the necessary condition and rotation algorithm which guarantee the three-way balancing. We propose multi-level composite estimators (MCE) from this design and derive their variances and mean squared errors (MSE), assuming the correlation from the measurements of the same sample unit and three types of biases in monthly sample.

  • PDF

Neutral Point Voltage Control for Grid-Connected Three-Phase Three-Level Photovoltaic Inverter (계통연계형 3상 3레벨 태양광 인버터의 중성점 전압제어)

  • Park, Woonho;Yang, Oh
    • Journal of the Semiconductor & Display Technology
    • /
    • v.14 no.4
    • /
    • pp.72-77
    • /
    • 2015
  • Three-level diode clamped multilevel inverter, generally known as neutral point clamped (NPC) inverter, has an inherent problem causing neutral point (NP) potential variation. Until now, the NP potential problem of variation has been investigated and lots of solutions have also been proposed. This paper presents a neutral point voltage control technology using the anti-windup PI controller and offset technology of PWM (Pulse Width Modulation) to control the variation of NPC 3-phase three-level inverter neutral point voltage. And the proposed algorithm is tested and verified using a PLL (Phase Locked Loop) in order to synchronize the phase voltage from the line voltage of grid. It significantly improves the voltage balancing under a solar fluctuation conditions of the inverter. Experimental results show the good performance and effectiveness of the proposed method.

Comparative Study on SVPWM Switching Sequences for VSIs

  • Vivek, G.;Biswas, Jayanta;Nair, Meenu D.;Barai, Mukti
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.1
    • /
    • pp.133-142
    • /
    • 2018
  • Paper presents a comparative study of space vector pulse width modulation (SVPWM) switching sequences for Voltage Source Inverters (VSIs). Various SVPWM switching sequences are studied for two and three level VSIs in linear modulation index region. The computations of dwell times are presented for two and three level VSIs based on space vector geometry in a synchronized and optimized manner. The existing SVPWM switching sequences are implemented using Matlab / Simulink and in an experimental setup for three phase two and three level VSIs. The simulation and experimental waveforms of conventional SVPWM (CSVPWM) and bus clamped SVPWM (BCSVPWM) are demonstrated for two and three level inverter respectively. The performance of different SVPWM switching sequences are evaluated and presented based on weighted voltage total harmonic distortion (THD).

Evaluation of a Three-Phase Three-Level ZVZCS DC-DC Converter Using Phase-Shift PWM Strategy

  • Kongwirat, Thammachat;Jangwanitlert, Anuwat
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.5
    • /
    • pp.1902-1915
    • /
    • 2017
  • This paper presents the evaluation of a three-phase three-level DC-DC converter which achieves the soft switching condition for all switches in the circuit and uses the phase-shift PWM strategy to adjust electric power at the output side. According to the analysis, the operation modes can be categorized into two cases: in the first case, where the phase shift angle is less than 120 degrees and in the second case, where the phase shift angle is more than 120 degrees. The outer switches of the circuit operate under ZVS condition and the inner switches operate under ZVZCS condition. It has been discovered that under ZCS condition of the inner switches, when the blocking capacitors decrease, they make the voltage across the blocking capacitor higher so the current reduce rapidly. A three-phase three-level DC-DC converter has a maximum efficiency of 93.5% when its load is of 5.7 kW. The results from the experiment have been compared to the results obtained by the $MATLAB^{(R)}$ simulator in order to confirm the validity of the proposed converter.

Simplified Control Scheme of Unified Power Quality Conditioner based on Three-phase Three-level (NPC) inverter to Mitigate Current Source Harmonics and Compensate All Voltage Disturbances

  • Salim, Chennai;Toufik, Benchouia Mohamed
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.3
    • /
    • pp.544-558
    • /
    • 2013
  • This paper proposes a simplified and efficient control scheme for Unified Power Quality Conditioner (UPQC) based on three-level (NPC) inverter capable to mitigate source current harmonics and compensate all voltage disturbances perturbations such us, voltage sags, swells, unbalances and harmonics. The UPQC is designed by the integration of series and shunt active filters (AFs) sharing a common dc bus capacitor. The dc voltage is maintained constant using proportional integral voltage controller. The shunt and series AF are designed using a three-phase three-level (NPC) inverter. The synchronous reference frame (SRF) theory is used to get the reference signals for shunt and the power reactive theory (PQ) for a series APFs. The reference signals for the shunt and series APF are derived from the control algorithm and sensed signals are injected in tow controllers to generate switching signals for series and shunt APFs. The performance of proposed UPQC system is evaluated in terms of power factor correction and mitigation of voltage, current harmonics and all voltage disturbances compensation in three-phase, three-wire power system using MATLAB-Simulink software and SimPowerSystem Toolbox. The simulation results demonstrate that the proposed UPQC system can improve the power quality at the common connection point of the non-linear load.

NUMERICAL SIMULATION OF MULTIPHASE FLOW USING LEVEL CONTOUR RECONSTRUCTION METHOD (Level Contour Reconstruction 방법을 이용한 다상유동 수치해석)

  • Shin, Seung-Won
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.193-200
    • /
    • 2009
  • Recently, there have been efforts to construct hybrids among the existing methodologies for multiphase flow such as VOF, Level Set, and Front Tracking with the intention of facilitating simulations of general three-dimensional problems. As one of the hybrid method, we have developed the Level Contour Reconstruction Method (LCRM) for general three-dimensional multiphase flows including phase change. The main idea was focused on simplicity and a robust algorithm especially for the three-dimensional case. It combines characteristics of both Front Tracking and Level Set methods. While retaining an explicitly tracked interface using interfacial elements, the calculation of a vector distance function plays a crucial role in the periodic reconstruction of the interface elements in the LCRM method to maintain excellent mass conservation and interface fidelity. In addition, compact curvature formulation is incorporated for the calculation of the surface tension force thereby reducing parasitic currents to a negligible level.

  • PDF

The control method of 3-level PWM inverter in special application using neural networks (신경회로망을 사용한 특정용도의 3-level PWM 인버터 제어방법)

  • 이현원;김남해;박귀태
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10b
    • /
    • pp.1261-1264
    • /
    • 1996
  • This paper presents the design of a neural network based PWM technique for a three level inverter of electric trains. A three-level inverter has several advantages compared with a two-level inverter in this application. In viewpoint of correcting unbalance of DC-link voltage, a novel method is developed and verified in computer simulation.

  • PDF