• Title/Summary/Keyword: Three-Dimensional Resistivity

Search Result 81, Processing Time 0.019 seconds

Three-Dimensional Resistivity Modeling by Serendipity Element (Serendipity 요소법에 의한 전기비저항 3차원 모델링)

  • Lee, Keun-Soo;Cho, In-Ky;Kang, Hye-Jin
    • Geophysics and Geophysical Exploration
    • /
    • v.15 no.1
    • /
    • pp.33-38
    • /
    • 2012
  • A resistivity method has been applied to wide range of engineering and environmental problems with the help of automatic and precise data acquisition. Thus, more accurate modeling and inversion of time-lapse monitoring data are required since resistivity monitoring has been introduced to quantitatively find out subsurface changes With respect to time. Here, we used the finite element method (FEM) for 3D resistivity modeling since the method is easy to realize complex topography and arbitrary shaped anomalous bodies. In the FEM, the linear elements, also referred to as first order elements, have certain advantages of simple formulation and narrow bandwidth of system equation. However, the linear elements show the poor accuracy and slow convergence of the solution with respect to the number of elements or nodes. To achieve the higher accuracy of finite element solution, high order elements are generally used. In this study, we developed a 3D resistivity modeling program using high order Serendipity elements. Comparing the Serendipity element solutions for a cube model with the linear element solutions, we assured that the Serendipity element solutions are more accurate than the linear element solutions in the 3D resistivity modeling.

Effects of Water Treating on Surface Properties of Epoxy Insulation Materials (Epoxy 절연재료이 표면특성에 미치는 수분처리의 영향)

  • Lim, Kyung-Bum;Lee, Duck-Chool
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.49 no.10
    • /
    • pp.553-558
    • /
    • 2000
  • This paper deals with change of contact angle, surface potential decay, surface resistivity and XPS of water-treated epoxy insulator. From the experimental results on the contact angle was reduced from $74^{\circ}$to $24^{\circ}$ due to the formation of polar hydroxyl groups on surface which was associated with intermolecular reaction between epoxy chains of three-dimensional network structure and water molecules. From the experimental results in the surface potential decay of water treated-samples, it was found that the accumulation of charge is decreased and the surface potential decay time is shortened by the interaction of polar hydroxyl groups induced on the treated surface as the increment of treatment time. The positive charging on the treated surface compared with negative charging is relatively lowered by the induction of polar hydroxyl groups. The surface resistivity was changed from $10^{15}[{\Omega}/cm^2$] to $10^{12}[{\Omega}/cm^2$] caused by water treatment. From XPS, it was found that the changes affected by the surface degradation of epoxy were caused by the generation of carboxyl groups through the chain decomposition and recombination with oxygen molecules in the air.

  • PDF

Delineation of a fault zone beneath a riverbed by an electrical resistivity survey using a floating streamer cable (스트리머 전기비저항 탐사에 의한 하저 단층 탐지)

  • Kwon Hyoung-Seok;Kim Jung-Ho;Ahn Hee-Yoon;Yoon Jin-Sung;Kim Ki-Seog;Jung Chi-Kwang;Lee Seung-Bok;Uchida Toshihiro
    • Geophysics and Geophysical Exploration
    • /
    • v.8 no.1
    • /
    • pp.50-58
    • /
    • 2005
  • Recently, the imaging of geological structures beneath water-covered areas has been in great demand because of numerous tunnel and bridge construction projects on river or lake sites. An electrical resistivity survey can be effective in such a situation because it provides a subsurface image of faults or weak zones beneath the water layer. Even though conventional resistivity surveys in water-covered areas, in which electrodes are installed on the water bottom, do give high-resolution subsurface images, much time and effort is required to install electrodes. Therefore, an easier and more convenient method is sought to find the strike direction of the main zones of weakness, especially for reconnaissance surveys. In this paper, we investigate the applicability of the streamer resistivity survey method, which uses electrodes in a streamer cable towed by ship or boat, for delineating a fault zone. We do this through numerical experiments with models of water-covered areas. We demonstrate that the fault zone can be imaged, not only by installing electrodes on the water bottom, but also by using floating electrodes, when the depth of water is less than twice the electrode spacing. In addition, we compare the signal-to-noise ratio and resolving power of four kinds of electrode arrays that can be adapted to the streamer resistivity method. Following this numerical study, we carried out both conventional and streamer resistivity surveys for the planned tunnel construction site located at the Han River in Seoul, Korea. To obtain high-resolution resistivity images we used the conventional method, and installed electrodes on the water bottom along the planned route of the tunnel beneath the river. Applying a two-dimensional inversion scheme to the measured data, we found three distinctive low-resistivity anomalies, which we interpreted as associated with fault zones. To determine the strike direction of these three fault zones, we used the quick and convenient streamer resistivity.

Three Dimensional Induced Polarization Modeling (3차원 IP 탐사의 모형 응답 계산)

  • Nam Myung-Jin;Suh Jung-Hee
    • Geophysics and Geophysical Exploration
    • /
    • v.4 no.1
    • /
    • pp.1-7
    • /
    • 2001
  • The application of geophysical survey methods need to be integrated to meet the increasing demands of imaging of the subsurface in the practical application of civil engineering, underground water survey and environmental problems. This paper examines the IP survey which can be surveyed simultaneously with DC resistivity survey. In this study, 3-D IP modeling algorithm was developed. The 3-D IP modeling algorithm was based on 3-D resistivity modeling by finite-element method. The result of 3-D modeling was compared with 2-dimensional modeling result. The result showed that the 3-D modeling algorithm developed in this study was accurate. Finally, the 3-D modeling algorithm developed in this paper will be useful for the study of IP data.

  • PDF

Application of 3D magnetotelluric investigation for geothermal exploration - Examples in Japan and Korea

  • Uchida Toshihiro;Song Yoonho;Mitsuhata Yuji;Lee Seong Kon
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2003.11a
    • /
    • pp.390-397
    • /
    • 2003
  • A three-dimensional (3D) inversion technique has been developed for interpretation of magnetotelluric (MT) data. The inversion method is based on the linearized least-squares (Gauss-Newton) method with smoothness regularization. In addition to the underground 3D resistivity distribution, static shifts are also treated as unknown parameters in the inversion. The forward modeling is by the staggered-grid finite difference method. A Bayesian criterion ABle is applied to search the optimum trade-off among the minimization of the data misfit, model roughness and static shifts. The method has been applied to several MT datasets obtained at geothermal fields in Japan and other Asian countries. In this paper, two examples will be discussed: one is the data at the Ogiri geothermal area, southwestern Japan, and the other is at the Pohang low-enthalpy geothermal field, southeastern Korea. The inversion of the Ogiri data has been performed stably, resulting in a good fitting between the observed and computed apparent resistivities and phases. The recovered 3D resistivity structure is generally similar to the two-dimensional (2D) inversion models, although the deeper portion of the 3D model seems to be more realistic than that of the 2D model. The 3D model is also in a good agreement with the geological model of the geothermal reservoirs. 3D interpretation of the Pohang MT data is still preliminary. Although the fitting to the observed data is very good, the preliminary 3D model is not reliable enough because the station coverage is not sufficient for a 3D inversion.

  • PDF

An Application of loop-loop EM Method for Geotechnical Survey (지반조사를 위한 loop-loop 전자탐사 기법의 적용)

  • You Jin-Sang;Song Yoonho;Seo1 Soon-Jee;Song Young-Soo
    • Geophysics and Geophysical Exploration
    • /
    • v.4 no.2
    • /
    • pp.25-33
    • /
    • 2001
  • Loop-loop electromagnetic (EM) survey in frequency domain has been carried out in order to provide basic solution to geotechnical applications. Source and receiver configuration may be horizontal co-planar (HCP) and/or vertical co-planar (VCP). Three quadrature components of mutual impedance ratio for each configuration are used to construct the subsurface image. For the purpose of obtaining the model response and validating the reasonable performance of the inversion, we obtained each responses of two-layered and three-layered earth models and two-dimensional (2-D) isolated anomalous body. The response of 2-D isolated anomalous body has been calculated using extended Born approximation for the solution of 2.5-D integral equation describing EM scattering problem. As a result of the least-squares inversion with variable Lagrangian multiplier, we could construct more resolvable image from HCP data than VCP data. Furthermore, joint inversion of HCP and VCP data made better stability and resolution of the inversion. Resistivity values, however, did not exactly match the true ones. Loop-loop EM field data was obtained with EM34-3XL system manufactured by Geonics Ltd. (Canada). Electrical resistivity survey was conducted on the same line for the comparison in advance. Since the constructed image from loop-loop EM data by 2-D inversion algorithm showed almost similar resistivity distribution to that from electrical resistivity one, we expect the developed 2.5-D loop-loop EM inversion program can be applied for the reconnaissance site survey.

  • PDF

3-D Resistivity Imaing of a Large Scale Tumulus (대형 고분에서의 3차원 전기비저항 탐사)

  • Oh, Hyun-Dok;Yi, Myeong-Jong;Kim, Jung-Ho;Shin, Jong-Woo
    • Geophysics and Geophysical Exploration
    • /
    • v.14 no.4
    • /
    • pp.316-323
    • /
    • 2011
  • To test the applicability of resistivity survey methods for the archaeological prospection of a large-scale tumulus, a three-dimensional resistivity survey was conducted at the $3^{rd}$ tumulus at Bokam-ri, in Naju city, South Korea. Since accurate topographic relief of the tumulus and electrode locations are required to obtain a high resolution image of the subsurface, electrodes were installed after making grids by threads, which is commonly used in the archaeological investigation. In the data acquisition, data were measured using a 2 m electrode spacing with the line spacing of 1 m and each survey line was shifted 1 m to form an effective grid of 1 m ${\times}$ 1 m. Though the 3-D inversion of data, we could obtain the 3-D image of the tumulus, where we could identify the brilliant signature of buried tombs made of stones. The results were compared with the previous excavation results and we could convince that a 3-D resistivity imaging method is very useful to investigate a large-scale tumulus.

Geostatistical Approach to Integrated Modeling of Iron Mine for Evaluation of Ore Body (철광산의 광체 평가를 위한 지구통계학적 복합 모델링)

  • Ahn, Taegyu;Oh, Seokhoon;Kim, Kiyeon;Suh, Baeksoo
    • Geophysics and Geophysical Exploration
    • /
    • v.15 no.4
    • /
    • pp.177-189
    • /
    • 2012
  • Evaluation of three-dimensional ore body modeling has been performed by applying the geostatistical integration technique to multiple geophysical (electrical resistivity, MT) and geological (borehole data, physical properties of core) information. It was available to analyze the resistivity range in borehole and other area through multiple geophysical data. A correlation between resistivity and density from physical properties test of core was also analyzed. In the case study results, the resistivity value of ore body is decreased contrast to increase of the density, which seems to be related to a reason that the ore body (magnetite) includes heavy conductive component (Fe) in itself. Based on the lab test of physical properties in iron mine region, various geophysical, geological and borehole data were used to provide ore body modeling, that is electrical resistivity, MT, physical properties data, borehole data and grade data obtained from borehole data. Of the various geostatistical techniques for the integrated data analysis, in this study, the SGS (sequential Gaussian simulation) method was applied to describe the varying non-homogeneity depending on region through the realization that maintains the mean and variance. With the geostatistical simulation results of geophysical, geological and grade data, the location of residual ore body and ore body which is previously reported was confirmed. In addition, another highly probable region of iron ore bodies was estimated deeper depth in study area through integrated modeling.

Applicability of Geophysical Prospecting for water leakage detection in water utilization facilities (수리시설물의 누수탐지를 위한 물리탐사의 적용성)

  • Park Sam-Gyu;Song Sung-Ho;Choi Jong-hak;Choi Bo-Gyu;Lee Byoung-Ho
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2002.09a
    • /
    • pp.179-195
    • /
    • 2002
  • This paper examined the applicability of geophysical prospecting for water leakage detection of the water utilization facilities. Electrical resistivity survey and spontaneous-potential survey were carried out for the water leakage detection of dike and embankment, and the applicability was confirmed from many case studies. However, in order to efficiently maintain and detection of the more accurate water points in the embankment, the efficiently maintain and detection of the more accurate water leakage points in the embankment, the requirements are as follows; 1) It is necessary to use the electrical resistivity survey jointly with the spontaneous-potential survey in order to improve the reliability of water leakage information. 2) It is important to understand physical properties of the soil which influences the electrical resistivity of embankment in order to accurately grasp the water leakage points from the result of the electrical resistivity survey. 3) It is necessary to introduce the three-dimensional prospecting in order to improve the reliability of the measured value. 4) Introductions of the monitoring measurement system are necessary in order to efficiently and economically maintain of the water utilization facilities.

  • PDF

Controlled Source Magnetotellurics with Vector Measurement Using Electric and Magnetic Sources (전기장 또는 자기장 송신원을 이용한 벡터 CSMT)

  • Lee, Heuisoon;Song, Yoonho
    • Economic and Environmental Geology
    • /
    • v.30 no.5
    • /
    • pp.451-458
    • /
    • 1997
  • The horizontal magnetic dipole as well as electrical dipole was adopted as a source to compute one-dimensional electromagnetic field behavior in controlled source magnetotellurics. he Cagniard impedances due to horizontal magnetic dipole source, especially phases, showed better frequency characteristics than those due to electric one. The magnetic dipole is inferior to the electric dipole in the point of relatively weak transmitting power at low frequency. But considering high resistivity charateristics of Korean geology, the magnetic dipole source is recommended for the survey up to depth of 500 m. A vector CSMT was introduced to get more reliable data in the area of two- or three-dimensional structures. A software and interpretation technique using polarization ellipses were developed. The technique was tested by synthetic data, which provided theoretical basis of the methodology. Although CSMT has inevitable limitation of investigation depth due to practically possible source-receiver separation, we proposed to use the technique developed in this paper where MT is not available, for example, in extremely noisy area or for shallow target.

  • PDF