• Title/Summary/Keyword: Three-Dimensional Imaging

Search Result 710, Processing Time 0.029 seconds

Performance Evaluation of a Rapid Three Dimensional Diffusion MRI

  • Numano, Tomokazu;Homma, Kazuhiro;Nishimura, Katsuyuki
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.356-358
    • /
    • 2002
  • MRI, particularly diffusion weighted imaging (DWI), plays vital roles in detection of the acute brain infarction$\^$1-4/ and others metabolic changes of biological tissues. In general, every molecule in biological tissues may diffuse and move randomly in three-dimensional space. However, in clinical diagnosis, only 2D-DWI is used. The authors have developed a new method for rapid three-dimensional DWI (3D-DWI). In this method, by refocusing of the magnetized spin with the applied gradient field, direction of which is opposite to phase encoding field. Magnetized spin of $^1$H is kept under the SSFP (steady state free precession)$\^$5-6/. Under SSFP, in addition of FID, spin echo and stimulated echo are also generated, so the acquired signal is increased. The signal intensity is increased depending on flip angle (FA) of magnetized spin. This phenomenon is confirmed by human brain and phantom studies. The performance of this method is quantitatively analyzed by using both of conventional spin echo DWI and 3D-DWI. From experimental results, three dimensional diffusion weighted images are obtained correctly for liquid phantoms (water, acetone and oil), diffusion coefficient is enhanced in each image. Therefore, this method will provide useful information for clinical diagnosis.

  • PDF

High-speed Three-dimensional Surface Profile Measurement with the HiLo Optical Imaging Technique

  • Kang, Sewon;Ryu, Inkeon;Kim, Daekeun;Kauh, Sang Ken
    • Current Optics and Photonics
    • /
    • v.2 no.6
    • /
    • pp.568-575
    • /
    • 2018
  • Various techniques to measure the three-dimensional (3D) surface profile of a 3D micro- or nanostructure have been proposed. However, it is difficult to apply such techniques directly to industrial uses because most of them are relatively slow, unreliable, and expensive. The HiLo optical imaging technique, which was recently introduced in the field of fluorescence imaging, is a promising wide-field imaging technique capable of high-speed imaging with a simple optical configuration. It has not been used in measuring a 3D surface profile although confocal microscopy originally developed for fluorescence imaging has been adapted to the field of 3D optical measurement for a long time. In this paper, to the best of our knowledge, the HiLo optical imaging technique for measuring a 3D surface profile is proposed for the first time. Its optical configuration and algorithm for a precisely detecting surface position are designed, optimized, and implemented. Optical performance for several 3D microscale structures is evaluated, and it is confirmed that the capability of measuring a 3D surface profile with HiLo optical imaging technique is comparable to that with confocal microscopy.

An improved 2D/3D convertible integral imaging with two parallel display devices

  • Choi, Hee-Jin;Park, Jae-Hyeung;Kim, Joo-Hwan;Cho, Seong-Woo;Lee, Byoung-Ho
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2005.07a
    • /
    • pp.46-49
    • /
    • 2005
  • In this paper, a novel 2D/3D convertible display system based on integral imaging is proposed. Combining two liquid crystal display panels with integral imaging, it is possible to convert the display between two-dimensional mode and three-dimensional mode without mechanical movement. The proposed method is proven by preliminary experiments.

  • PDF

Properties of resolution improvement for three-dimensional integral imaging using dynamic microlens array (동적 마이크로 렌즈 배열을 사용한 3차원 완전 결상에서의 해상도 개선 특성)

  • 조명진;김복수;장주석
    • Korean Journal of Optics and Photonics
    • /
    • v.15 no.2
    • /
    • pp.130-136
    • /
    • 2004
  • We investigate characteristics of viewing resolution improvement in three-dimensional integral imaging, when a dynamic lens array method is adopted. We show that the viewing resolution changes for different moving directions and distances of the lens array through computer-synthesized integral imaging. From this study, optimal moving conditions of the lens array for efficient viewing resolution improvement can be determined.

Trends in Terahertz Imaging Technology (테라헤르츠 이미징 기술 개발 동향)

  • Choi, D.H.;Shin, J.H.;Lee, E.S.;Moon, K.W.;Lee, I.M.;Park, D.W.;Kim, H.S.;Kim, M.G.;Choi, K.S.;Park, K.H.
    • Electronics and Telecommunications Trends
    • /
    • v.34 no.5
    • /
    • pp.26-35
    • /
    • 2019
  • Modern imaging technologies utilizing electromagnetic waves are indispensable in our daily lives. Applications, such as television and smartphone screens, radar imaging for weather forecast, and medical imaging, can be attributed to technology developments in various electromagnetic regions. Terahertz (THz) waves, electromagnetic (EM) waves located between far infrared and microwave regions, had left unexplored EM waves. Recent advances in technology have led to various two-dimensional and three-dimensional THz imaging techniques. In this article, we explain THz imaging techniques as well as the experimental results from our laboratory. Additionally, we introduce commercial THz cameras developed worldwide. Finally, we present the applications of THz imaging techniques.

Development of Operational Technology and Integrated Measurement Information Management System for the Radioactivity Measurement Device (방사능 측정장치 운영 기술 및 측정정보 통합관리 시스템 개발)

  • Dong-Sik Jin;Kyeong-Ryeong Kim;Jae-Geun Lee
    • Journal of radiological science and technology
    • /
    • v.47 no.3
    • /
    • pp.183-195
    • /
    • 2024
  • Additional functional upgrades to the large-area compton camera (LACC) measurement device that can provide characteristics evaluation information (nuclear species and radioactivity) and two-dimensional or three-dimensional distribution imaging information of radioactive materials existing in surface or internal of concrete structures are required in terms of work stability and efficiency in order to apply to actual decommissioning sites such as nuclear power plants or medical cyclotron facilities by using this measurement device. To this purpose, the technology that allows radiation workers to intuitively and visually check the distribution of radioactive materials in advance by matching the two-dimensional distribution imaging information of radioactive materials obtained through the LACC measurement device and visual imaging of the measurement zone (10 m × 5 m) was developed. In addition, the separate system that can automatically adjust the position (height) in units of the measurement area size (0.7 m × 0.3 m × 0.8 m) of the LACC measurement device was developed and the integrated management system for characteristics evaluation information and two-dimensional or three-dimensional distribution imaging information obtained per unit of measurement for radioactive materials was developed. These functional upgrades related to LACC measurement device can improve work efficiency and safety when measuring radioactivity of concrete structures and enable the establishment of appropriate decommissioning strategies using radioactivity measurement information for decommissioning nuclear power plants or medical cyclotron facilities.

A Preliminary Study on Developing a Photoacoustic Imaging System for Inflammatory Arthritis Diagnosis (관절염 진단용 광음향 이미징 시스템 개발을 위한 선행 연구)

  • Youn, Jong-In;Park, Ji-Won
    • The Journal of Korean Physical Therapy
    • /
    • v.22 no.4
    • /
    • pp.83-89
    • /
    • 2010
  • Purpose: The goal of this study was to investigate the feasibility for the early diagnosis of inflammatory arthritis by the reconstruction of three-dimensional photoacoustic imaging with a tissue phantom. Methods: Q-switched Nd:YAG laser (l = 532 nm) was applied to a tissue phantom to generate photoacoustic waves, and the acquired photoacoustic signals at different positions around the sample were used to recombine the distribution of the optical absorption and the images were subsequently generated through a reconstruction algorithm. Results: From the acquired photoacoustic signals, the surface andinner core of the phantom was clearly distinguished. Furthermore, the back-projection algorithm was able to reconstruct two-dimensional and three-dimensional photoacoustic images that contained the optical absorption property information of the tissue phantom. Conclusion: The results indicate that the photoacoustic imaging technique has many advantages such as high optical contrast and high acoustic resolution. The acquired images can be used for the early diagnosis of inflammatory arthritis by the structural information obtained from the region of interest.

Three Dimensional Computed Tomography in the Assessment of Subtle Fracture in Dogs (컴퓨터단층촬영에서 3차원 재구성 영상을 통한 개의 골절 진단)

  • 이기창;권정국;송경진;최민철
    • Journal of Veterinary Clinics
    • /
    • v.20 no.4
    • /
    • pp.523-526
    • /
    • 2003
  • Three dimensional computed tomographic images were obtained in two cases with trauma. The first case of a 3 year-old male Maltese, with ataxia and head tilting due to head trauma was referred to veterinary medical teaching hospital, Seoul National University. Remarkable findings were not found on survey radiographs. With the help of three-dimensional reconstruction computed tomographic imaging, parietal and occipital bone fracture was identified. The second case of 4 month-old female Yorkshire terrier with left forelimb lameness was referred right after trauma. Survey radiography showed obvious incongruity of the elbow joint. Lateral and medial condyle of the left humerus fracture and lateral displacement of the left ulna were apparent in three-dimensional computed tomographic image. It was considered that three-dimensional computed tomography could be used as an aid modality for the exact evaluation of extends and degree of fracture as well as planning of orthopedic surgery.

Wood Identification of Historical Architecture in Korea by Synchrotron X-ray Microtomography-Based Three-Dimensional Microstructural Imaging

  • HWANG, Sung-Wook;TAZURU, Suyako;SUGIYAMA, Junji
    • Journal of the Korean Wood Science and Technology
    • /
    • v.48 no.3
    • /
    • pp.283-290
    • /
    • 2020
  • For visual inspection-based wood identification, optical microscopy techniques typically require a relatively large sample size, and a scanning electron microscope requires a clean surface. These novel techniques experience limitations for objects with highly limited sampling capabilities such as important and registered wooden cultural properties. Synchrotron X-ray microtomography (SR-µCT) has been suggested as an effective alternative to avoid such limitations and various other imaging issues. In this study, four pieces of wood fragments from wooden members used in the Manseru pavilion of Bongjeongsa temple in Andong, Korea, wereused for identification. Three-dimensional microstructural images were reconstructed from these small wood samples using SR-µCT at SPring-8. From the analysis of the reconstructed images, the samples were identified as Zelkova serrata, Quercus sect. Cerris, and Pinus koraiensis. The images displayed sufficient spatial resolution to clearly observe the anatomical features of each species. In addition, the three-dimensional imaging allowed unlimited image processing.

Arbitrary Cross Sectional Display from Three-dimensional Reconstructed Image by Hierarchical Model (계층적 모델에 의한 3차원 재구성 영상의 임의단면 표시)

  • 유선국;김선호
    • Journal of Biomedical Engineering Research
    • /
    • v.10 no.2
    • /
    • pp.157-164
    • /
    • 1989
  • Three-dimensional imaging and manipulation of CT data are becoming increasingly important for deterRing the complex structure and pathologies. Octree which is a hierarchical data model is used to reconstruct three- dimensional objects from CT scans. Orthogonal cross sections are displayed by traverse the octree partially. Arbitrary oblique planes are derived by intersecting the square region of plane and cubic volume of octal node. Thia method enables the display of multi-structured complex organ ann the realization by personal computer.

  • PDF