• Title/Summary/Keyword: Three phase PWM-inverter

Search Result 238, Processing Time 0.028 seconds

A Novel Voltrol Method of Three-Phase PWM Inverter for UPS Application (UPS 응용을 위한 3상 PWM 인버터의 새로운 전압 제어 방법)

  • 이영조;박남주;임철우;정세교
    • Proceedings of the KIPE Conference
    • /
    • 1999.07a
    • /
    • pp.260-265
    • /
    • 1999
  • This paper describes a novel control method of a three-phase PWM inverter for uninterruptible power supply(UPS) applications. To obtain the fast dynamics and excellent harmonic characteristics, a new state feedback control technique is proposed. The proposed control consists of the inner-loop current and outer-loop voltage controllers with a load current estimator to reduce the effects of the load variations and nonlinearity. In order to verify the effectiveness of the proposed control, the simulation is carried out for various load condition.

  • PDF

A Comparative Study on the Power Spectrum of Three-Phase and Two-Phase RCD-PWM Scheme with Fixed Switching Frequency (고정 스위칭 주파수를 갖는 3상 및 2상 RCD-PWM의 파워 스펙트럼 비교)

  • Kim J.G.;Jung Y.G.;Lim Y.C.;Yang H.Y.;Wi S.O.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07a
    • /
    • pp.308-312
    • /
    • 2003
  • The objective of this paper is to investigate the power spectrum of a three-phase and a two-phase RCD (Random Pulse Centered Displacement) PWM scheme. The two-phase or three-phase pulses of RCD-PWM scheme are mutually center-aligned as in SVM(Space Vector Modulation), but the common pulse center is displaced randomly from the middle of the period. To verify the validity of the proposed two-phase RCD-PWM scheme, the power spectra of the output voltage, the d.c link current in the inverter drives and the radiated acoustic noise are experimentally investigated. And, the performance of the proposed two-phase RCD-PWM scheme was compared and discussed with the conventional three-phase RCD-PWM scheme.

  • PDF

Control of Three Phase VSI using Fundamental Data of the Carrier and Signal for Reducing the THO (반송파와 신호파의 기본 데이터를 이용한 3상 전압형 인버터의 THD 저감 제어)

  • Kim, Yeong-Min;Hwang, Jong-Sun;Kim, Jong-Man;Park, Hyun-Chul
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.09a
    • /
    • pp.34-37
    • /
    • 2001
  • This research suggested the new algorithm controlled by micro processor which is already stored by various PWM form of output voltage by using fundamental data of the carrier and signal. The determined PWM pattern is not concerned with the signal wave form and the new algorithm can obtain the desired pulse width by synchronous of carrier. The PWM wave can be controlled with real time by using extra hardware and digital software and to speed up program processing, the control signals to switch the power semi-conductor of three phase PWM inverter, simultaneously use the output signal by microprocessor and extra hardware, and control signal by software. In the end, this method was proved by applying to Three phase voltage source inverter.

  • PDF

Low-Cost Single-Phase to Three-Phase AC/DC/AC PWM Converters for Induction Motor Drives (유도전동기 구동을 위한 저가형 단상-3상 AC/DC/AC PWM 컨버터)

  • 김태윤;이지명;석줄기;이동춘
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.7 no.4
    • /
    • pp.322-331
    • /
    • 2002
  • In this paper, a single-phase to three-phase PWM converter topology using a single-phase half-bridge PWM rectifier and a 2-leg inverter for low cost three-phase induction motor drives is proposed. In addition, the source voltage sensor is eliminated with a state observer which controls the deviation between the model current and the system current to be zero. The converter topology is of lower cost than the conventional one, which gives sinusoidal input current, unity power factor, dc output voltage control, bidirectional power flow and VVVF output voltage. The experimental results for V/F control of 3Hp induction motor drives have been shown.

three phase current reconstruction method applying predictive current in three shunt sensing PWM inverter (예측 전류를 적용한 3 션트 PWM 인버터의 전류 복원 기법)

  • Hong, Sung-Woo;Kim, Do-Yun;Won, Il-Kuen;Kim, Young-Real;Won, Chung-yuen
    • Proceedings of the KIPE Conference
    • /
    • 2016.07a
    • /
    • pp.99-100
    • /
    • 2016
  • In a AC motor used by three phase inverter, the phase current must be measured to control instantaneous torque. It is expensive to use current sensor for measuring current in low cost motor. So, shunt resistor is used to measure current. But, the method sensing the phase current using shunt resistor cannot perform the vector control in high speed because of the area that impossible to restore three phase current. In this paper, predictive current is proposed for reconstructing the current in the impossible current sensing area that reduce the current ripple in TSSI(Three shunt sensing inverter) for PMSM.

  • PDF

Power Spectrum of Two-Phase and Three-Phase RCD-PWM Scheme for Switching Noise Reduction of Induction Motors (유도모터의 스위칭 소음저감을 위한 2상 및 3상 RCD-PWM기법의 파워 스펙트럼)

  • 위석오;정영국;임영철
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.9 no.2
    • /
    • pp.178-186
    • /
    • 2004
  • This paper proposes a two-phase RCD-PWM scheme which is much better than a three-phase RCD-PWM scheme from the standpoint of the broadening and linearizing effect of the power spectrum. To implement the proposed scheme and conventional scheme, the experiment based on the SAB-Cl67 micro-controller was executed. Based on the space vector modulation technique, the duty ratio of the pulses is calculated using the SAB-Cl67 and each of PWM pulses is located randomly in each switching interval. The power spectrum of the output voltage, output current, the d.c link current and the acoustic noise radiated from inverter drives are experimentally investigated. 1'hen, the performance of the proposed scheme was compared and discussed with the conventional scheme.

Elimination of harmonics in three-Phase PWM inverter using auxiliary partial resonant circuit (보조부분 공진 회로를 이용한 삼상 PWM 인버터의 고조파 제거)

  • Suh, Ki-Young;Lee, Hyun-Woo;Kim, Young-Mun;Mun, Sang-Pil
    • Proceedings of the KIEE Conference
    • /
    • 1998.11a
    • /
    • pp.137-140
    • /
    • 1998
  • A new SPWM inverter using three-phase boost converter by auxiliary partial resonant with high power factor and high efficiency is proposed. The proposed boost converter is constructed by using a resonant network in parallel with the switch of the conventional boost converter. The devices are switched at zero voltage or zero current eliminating the switching loss. A new Partial resonant boost converter achieves zero-voltage switching (ZVS) or zero-current switching (ZCS) for all switch devices without increasing their voltage and current stresses. This paper introduces elimination of low-order harmonics compared with conventional SPWM inverter and SPWM inverter using three-phase boost converter by auxiliary Partial resonant.

  • PDF

A Comparative Study on the Performance of Two-Phase and Three-Phase Randomized Pulse Position PWM Scheme for Mitigation of Audible Switching Acoustic Noise in Motor Drives (모터 구동 장치의 가청 스위칭 소음 저감을 위한 2상 및 3상 랜덤 펄스 위치 PWM기법의 성능 비교)

  • 정영국;위석오;나석환;임영철
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.7 no.3
    • /
    • pp.224-236
    • /
    • 2002
  • In this paper, a comparative study on the performance of two-phase and three-phase randomized pulse position PWM scheme for mitigation of audible switching acoustic noise in motor drives is done. In the randomized Pulse Position PW, each of two-Phase or three-phase PWM Pulses is located randomly in each switching interval. Simulation and experimental efforts were executed to investigate the spread effects of Power spectra of inverter output voltage, waveforms of ripple current and audible switching acoustic noise. As results, two-phase RP% scheme is more effective from the viewpoint of switching loss and ease of implementation while the three-phase RPWM scheme is more effective from the viewpoint of the spread effects of power spectra. Also, from the view point of the audible switching acoustic noise in motor drives, two-phase and three-phase RPW schemes are nearly the same.

A Novel Active Damping Control of a Three-phase PWM Inverter with LC Filter

  • Kim, Kwang-Seob;Hyun, Dong-Seok
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.4
    • /
    • pp.1589-1596
    • /
    • 2015
  • A novel control method of a three-phase PWM inverter with LC filter is proposed. The transfer function of LC filter is the same as that of 2nd order low pass filter(2nd LPF) which has a zero damping ratio. A simple method of implementing 2nd LPF with damping ratio is to add resistor to inductor or capacitor of LC filter. In an industrial application, it is not practical to adopt damping resistor because it results in losses being proportional to square of current flowing through resistor. Instead of using damping resistors, the proposed active damping control(ADC) utilizes all pass filter(APF) and considers inherent processing delay of digital controller. The overall transfer function of the proposed method is the same as a 2nd LPF and its damping ratio is also controllable via control variables. Detailed design and implementation of controller is also presented. Experiments are conducted with a 7.5kVA induction motor drive system controlled by PWM converter and inverter. Test waveforms are also presented to verify the proposed LC filter control algorithm.

Sensing of Three Phase PWM Voltages Using Analog Circuits (아날로그 회로를 이용한 3상 PWM 출력 전압 측정)

  • Jou, Sung-Tak;Lee, Kyo-Beum
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.11
    • /
    • pp.1564-1570
    • /
    • 2015
  • This paper intends to suggest a sensing circuit of PWM voltage for a motor emulator operated in the inverter. In the emulation of the motor using a power converter, it is necessary to measure instantaneous voltage at the PWM voltage loaded from the inverter. Using a filter can generate instantaneous voltage, while it is difficult to follow the rapidly changing inverter voltage caused by the propagation delay and signal attenuation. The method of measuring the duty of PWM using FPGA can generate output voltage from the one-cycle delay of PWM, while the cost of hardware is increasing in order to acquire high precision. This paper suggests a PWM voltage sensing circuit using the analogue system that shows high precision, one-cycle delay of PWM and low-cost hardware. The PWM voltage sensing circuit works in the process of integrating input voltage for valid time by comparing levels of three-phase PWM input voltage, and produce the output value integrated at zero vector. As a result of PSIM simulation and the experiment with the produced hardware, it was verified that the suggested circuit in this paper is valid.