• Title/Summary/Keyword: Three electrode structure

Search Result 115, Processing Time 0.024 seconds

The study of shape of electrodes and I-V characteristics for Ultraviolet LED

  • Trung, Nguyen Huu;Dang, Vu The;Hieu, Nguyen Van
    • Journal of IKEEE
    • /
    • v.17 no.3
    • /
    • pp.221-228
    • /
    • 2013
  • About functional parameters of a LED/UVLED (Light Emitting Diode/Ultra Violet LED), one of the most important parameters is the I-V characteristic. By researching factors affect to the I-V characteristic of uvled, we found that beside of the structure of the device itself, there is the influence of the electrode materials, electrode shapes, the process of wiring and packaging. In this work, we want to improve the performance of UVLED to find out the optimal mask design principles. The study is based on theoretical mathematical models, as well as the use of simulation software tool Comsol. From all results obtained, the team has improved mask design to manufacture electrodes for GaN-based UVLED. Electrode masks are designed by three softwares, which are Intellisuite, Klayout and AutoCad. Intellisuite masks would be used in fabrication simulation while Klayout and AutoCad are used to fabricate electrodes in experiments. As well as, we silmulated the structure of an uvled 355nm emission wavelength by TCAD software, in order to compare with uvled sample that has the same emission wavelength.

A Study on Operation Characteristics of Three Electrode Trigger Gap Switch (3전극 트리거 갭 스위치 동작특성에 관한 연구)

  • Hong, Tae-Yun;Han, Sang-Bo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.4
    • /
    • pp.549-553
    • /
    • 2018
  • The applications of the pulse power technology are expanding and the necessity of a large current switch as a core component of pulsed power is increasing. A trigger gap switch composed of three electrodes was fabricated and the discharge characteristics were studied according to the change of the pressure, the shape of the main electrode, and the gap distance when the trigger pulse was applied. As a main result, the stable operation range was confirmed through the discharge inception voltage according to the gap distance and electric field analysis was performed in the same structure to confirm the electric field value of the discharge inception voltage.

A study on the electrode-structure for the high luminous efficient PDPs

  • Min, Byoung-Kuk;Yoo, Jun-Young;Kim, Jung-Hun;Choi, Kwang-Yeol;Yoo, Eun-Ho;Park, Myoung-Ho
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2002.08a
    • /
    • pp.579-582
    • /
    • 2002
  • We developed three kinds of electrode-structures for high luminance and luminous efficiency. Also, we optimized the mixture gas. Three kinds of 7.5-inch experimental panels having a pixel pitch of 0.864mm were evaluated, and high efficiency of 1.6lm/W was obtained in the panel type2.

  • PDF

Effect on the Sensitivity of a Hydrogen Sensor by Pd Electrode Patterns at High Temperature (고온에서 Pd 전극의 형태가 수소 센서의 감도에 미치는 영향)

  • Kim, Seong-Jeen
    • Journal of IKEEE
    • /
    • v.22 no.2
    • /
    • pp.356-361
    • /
    • 2018
  • We investigated a hydrogen gas sensor which is available in a high temperature atmosphere. The hydrogen sensors were fabricated into a metal-oxide-semiconductor (MOS) structure made of $Pd/Ta_2O_5/SiC$, and the thin tantalum oxide ($Ta_2O_5$) layer was fabricated by rapid thermal oxidation (RTO). In the experiment, we made three types of sensors with different palladium (Pd) patterns to evaluate the effect of Pd electrode on response characteristics. As the result, the response characteristics in capacitance were improved further when the filled area of the Pd electrode became larger.

Nanotube Morphology Change of Ti-Ta-Zr Alloy as Zr Content

  • Kim, Won-Gi;Choe, Han-Cheol;Ko, Yeong-Mu
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.105-106
    • /
    • 2008
  • Nanotube morphology change of Ti-Ta-Zr alloy as Zr content increase has been researched using various experimental methods. Ti-Ta-Zr(3, 7 and 15 wt%) alloys were prepared by arc melting and nano-structure controlled for 24 hr at $1000^{\circ}C$ in argon atmosphere. Formation of oxide nanotubes are conducted by anodizing a Ti-Ta-Zr alloy in $H_3PO_4$ electrolytes with small amounts of fluoride ions at room temperature. Electrochemical experiments were carried out with conventional three-electrode configuration with a platinum counter electrode and a saturated calomel reference electrode. The samples were embedded with epoxy resin, leaving a square surface area of $10mm^2$ exposed to the anodizing electrolyte, 1.0M $H_3PO_4$ containing 0.8wt% NaF.

  • PDF

Fabrication of Three-dimensionally Ordered Macroporous Electrode Materials by Using PMMA Template (PMMA 구를 주형으로 이용한 3DOM 전극 구조체의 제조)

  • Seo Kyoung Soo;Jung Ha-Kyun;Son Yongkeun
    • Korean Journal of Materials Research
    • /
    • v.14 no.8
    • /
    • pp.587-594
    • /
    • 2004
  • Three-dimensionally ordered macroporous (3DOM) structures of the $LiCoO_2$ electrode materials for Li secondary batteries were fabricated by using the close-packed arrays of PMMA spheres served as templates. In order to successfully fabricate the cathode materials with highly ordered array form, the metal citrates were applied to new precursors. The precursor/template composites were prepared by the infiltration with metal citrate precursors into the voids of template. By removing the PMMA templates, then, the inverse opal structures with the uniform pores of narrow size distribution were resulted. It was confirmed that the 3DOM $LiCoO_2$ material is to take a single phase of rocksalt (R3m) structure. In addition, 3DOM $LiNiO_2$ and $LiMn_{2}O_4$ cathode materials were fabricated using an identical preparation procedure. Also, the morphology of the 3DOM cathode materials calcined at $500^{\circ}C\;to\;700^{\circ}C$ was observed by scanning electron microscope.

Effect of the Configuration of Contact Type Textile Electrode on the Performance of Heart Activity Signal Acquisition for Smart Healthcare (스마트 헬스케어를 위한 심장활동 신호 검출용 접촉식 직물전극의 구조가 센싱 성능에 미치는 영향)

  • Cho, Hyun-Seung;Koo, Hye-Ran;Yang, Jin-Hee;Lee, Kang-Hwi;Kim, Sang-Min;Lee, Jeong-Hwan;Kwak, Hwy-Kuen;Ko, Yun-Su;Oh, Yun-Jung;Park, Su-Youn;Kim, Sin-Hye;Lee, Joo-Hyeon
    • Science of Emotion and Sensibility
    • /
    • v.21 no.4
    • /
    • pp.63-76
    • /
    • 2018
  • The purpose of this study was to investigate the effect of contact type textile electrode structure on heart activity signal acquisition for smart healthcare. In this study, we devised six contact type textile electrodes whose electrode size and configuration were manipulated for measuring heart activity signals using computerized embroidery. We detected heart activity signals using a modified lead II and by attaching each textile electrode to the chest band in four healthy male subjects in a standing static posture. We measured the signals four times repeatedly for all types of electrodes. The heart activity signals were sampled at 1 kHz using a BIOPAC ECG100, and the detected original signals were filtered through a band-pass filter. To compare the performance of heart activity signal acquisition among the different structures of the textile electrodes, we conducted a qualitative analysis using signal waveform and size as parameters. In addition, we performed a quantitative analysis by calculating signal power ratio (SPR) of the heart activity signals obtained through each electrode. We analyzed differences in the performance of heart activity signal acquisition of the six electrodes by performing difference and post-hoc tests using nonparametric statistic methods on the calculated SPR. The results showed a significant difference both in terms of qualitative and quantitative aspects of heart activity signals among the tested contact type textile electrodes. Regarding the configurations of the contact type textile electrodes, the three-dimensionally inflated electrode (3DIE) was found to obtain better quality signals than the flat electrode. However, regarding the electrode size, no significant difference was found in performance of heart signal acquisition for the three electrode sizes. These results suggest that the configuration method (flat/3DIE), which is one of the two requirements of a contact type textile electrode structure for heart activity signal acquisition, has a critical effect on the performance of heart activity signal acquisition for wearable healthcare. Based on the results of this study, we plan to develop a smart clothing technology that can monitor high-quality heart activity without time and space constraints by implementing a clothing platform integrated with the textile electrode and developing a performance improvement plan.

Three-dimensional and Multilayered Structure Prepared by Area of Platinum Transfer Printing (전사 인쇄에 의한 3차원 백금 다공성 다층구조)

  • Jeong, Seung-Jae;Choi, Yong Ho;Cho, Jeong Ho
    • Journal of Sensor Science and Technology
    • /
    • v.28 no.2
    • /
    • pp.113-116
    • /
    • 2019
  • A three-dimensional porous structure was fabricated by pattern transfer printing for applications of electrodes in gas sensors. To form replica patterns, solutions were mixed with acetone, toluene, heptane, and poly(methyl methacrylate). These replica patterns can also be formed on substrates such as polyimide, polydimethylsiloxane, and silicon. The wide range of line widths from 1 to $5{\mu}m$ was derived from the surface grating patterns of master substrates. The cross-bar pattern with 40 layers showed a thickness of 600 nm. The area of platinum transferred patterns with different line widths was enhanced to $20{\times}25mm$, which is applicable to various electrode patterns of gas sensors.

A Study on the Electronic Properties of Poly-$\gamma$ Benzyl $_D$-Glutamate Organic Thin Films (Poly-${\gamma}$ Benzyl $_D$-Glutamate 유기박막의 전자이동특성에 관한 연구)

  • Song, Jin-Won;Lee, Kyung-Sup;Lee, Bong-Ju;Gu, Hal-Bon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.05b
    • /
    • pp.86-89
    • /
    • 2002
  • We give pressure stimulation into organic thin films and then manufacture a device under the accumulation condition that the state surface pressure is 10[mN/m]. In processing of a device manufacture, we can see the process is good from the change of a surface pressure for organic thin films and transfer ratio of area per molecule. The structure of manufactured device is Au/Poly-${\gamma}$ Benzyl $_D$-Glutamate/Al and Au/Poly-${\gamma}$ Benzyl $_D$-Glutamate/Au; the number of accumulated layers is 1, 3, 5 and 7. Also, we then examined of the MIM device by means of I-V. The I-V characteristic of the device is measured from 0 to +2[V]. We determined electrochemical measurement by using cyclic voltammetry with a three-electrode system. LB film accumulated by monolayer on an ITO. In the cyclicvoltammetry, An Ag/AgCl reference electrode, a platinum wire counter electrode and LB film-coated ITO working electrode measured in $LiBF_4$ solution, stable up to 0.9V vs. Ag/AgCl.

  • PDF

A Study on the Interface Properties of Metal/Organic Films/Metal (Metal/Organic Films/Metal에서 계면특성에 관한 연구)

  • Song, Jin-Won;Cho, Su-Young;Choi, Young-Il;Lee, Kyung-Sup
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.07b
    • /
    • pp.723-726
    • /
    • 2002
  • We give pressure stimulation into organic thin films and then manufacture a device under the accumulation condition that the state surface pressure is 10[mN/m]. In processing of a device manufacture, we can see the process is good from the change of a surface pressure for organic thin films and transfer ratio of area per molecule. The structure of manufactured device is Au/Poly-$\gamma$ Benzyl $_D$-Glutamate/Al; the number of accumulated layers is 1, 3, 5 and 7. Also, we then examined of the MIM device by means of I-V. The I-V characteristic of the device is measured from 0 to +2[V]. We determined electrochemical measurement by using cyclic voltammetry with a three-electrode system. LB film accumulated by monolayer on an ITO. In the cyclicvoltammetry, An Ag/AgCl reference electrode, a platinum wire counter electrode and LB film-coated ITO working electrode measured in $LiBF_4$ solution, stable up to 0.9V vs. Ag/AgCl.

  • PDF