• Title/Summary/Keyword: Three dimensional ultrasonography

Search Result 12, Processing Time 0.013 seconds

Three Dimensional Ultrasonographic Evaluation with Intra-articular Saline Injection in Rotator Cuff Tear (회전근 개 파열의 수술 전 3차원 초음파 검사에서 관절내 생리식염수 주사 후 검사의 정확도)

  • Yum, Jae-Kwang;Shin, Yong-Woon;Park, Shin-Seung
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.2 no.2
    • /
    • pp.62-67
    • /
    • 2009
  • Purpose: The purpose of this study is to find out the accuracy and usability of the three dimensional ultrasonography in measuring the size of the rotator cuff tear, especially before and after the injection of normal saline into the glenohumeral joint. Materials and Methods: 14 patients of rotator cuff tear who were diagnosed and operated from August 2007 to September 2008 were included in this study and authors compared the size of rotator cuff tear measured with three dimensional ultrasonography with the real size measured intraoperatively. In preoperative ultrasonographic evaluation, horizontal and longitudinal length of rotator cuff tear before and after injection of normal saline intraarticularly. During the arthroscopic operation the size of tear was measured by passing a Kirschner wire through a spinal needle and direct measure was performed in open surgery. Results: The average difference was 8 mm in horizontal and 1.9 mm in longitudinal length of tear without saline injection between ultrasonographic and intraoperative measure. The average difference was 4.1 mm in horizontal and 1.6 mm in longitudinal length of tear after the normal saline injection. Conclusion: In three dimensional ultrasonographic evaluation in rotator cuff tear, intraarticular normal saline injection would produce more accurate results.

  • PDF

Preoperative Three Dimensional Ultrasonographic Evaluation of the Rotator Cuff Tear (회전근 개 파열에 대한 수술 전 3차원 초음파 검사의 유용성)

  • Yum, Jae-Kwang;Sin, Yong-Woon;Han, Jung-Il
    • Clinics in Shoulder and Elbow
    • /
    • v.11 no.1
    • /
    • pp.24-28
    • /
    • 2008
  • Purpose: We wanted to determine if preoperative three dimensional (3D) ultrasonographic evaluation for rotator cuff tear is useful to measure the real size of a torn rotator cuff for performing an operation Materials and Methods: This study included 15 cases (7 males and 8 female), and these patients were confirmed to have a full thickness tear of the rotator cuff by 3D ultrasonography and the operative findings, as well as on the magnetic resonance imaging (MRI). The average age of the patients was 55.4yrs. Results: The average difference between the 3D ultrasonographic and operative measurements of the full thickness tear of the rotator cuff was 0.7 mm in the transverse length and 2.0 mm in the longitudinal length. Conclusion: The low error between the 3D ultrasonographic and intraoperative measurements of rotator cuff tear shows the usefulness of preoperative 3D ultrasonographic evaluation for rotator cuff tear.

Single Extrahepatic Portosystemic Shunt in 3 Dogs: CT Findings and Progress (3마리의 개에서 발생한 단일 간외성 문맥전신 단락 증례)

  • Lee, Hee-Chun;Ji, Chang-Moo;Moon, Jong-Hyun;Cho, Kyu-Woan;Kim, Young-Ki;Kang, Byeong-Teck;Jung, Dong-In
    • Journal of Veterinary Clinics
    • /
    • v.29 no.6
    • /
    • pp.488-493
    • /
    • 2012
  • Two Maltese (2-year-old, intact female and 4-month-old, intact female) and a Pekingese (10-year-old, intact male) dogs were referred due to vomiting, anorexia, head-pressing and hypersalivation. Physical examinations, complete blood count, serum chemical analysis, radiography, ultrasonography and computed tomography (CT) were evaluated. Laboratory findings in these dogs included high hepatic enzyme, serum bile acid and ammonia concentration. Microhepatia was found on abdominal radiographs in two dogs. The existence of portosystemic shunt was presented in abdominal ultrasonography. The shunt vessel was identified in all dogs by CT imaging. Based on three-dimensional CT reconstruction, the origin and termination of each shunt vessel were defined certainly. In consequence, each dog was diagnosed single extrahepatic portosystemic shunt. After diagnosis, surgical treatment was performed in all dogs. This case report describes clinical finding, imaging characteristics, and three-dimensional CT imaging of single extrahepatic portosystemic shunt cases.

Effect of Contralateral Hip Adduction on Muscle Thicknesses of Lumbar Stabilizers and Pelvic Lateral Tilting During Hip Abduction in Side-lying (옆으로 누운 자세에서 고관절 외전시 반대 측 고관절 내전이 요추안정화 근육 두께와 골반 외측 경사에 미치는 영향)

  • Kim, Hyo-Uen;Choi, Bo-Ram;Kim, Su-Jung;Lee, Won-Hwee;Kwon, Oh-Yun
    • Physical Therapy Korea
    • /
    • v.19 no.1
    • /
    • pp.19-27
    • /
    • 2012
  • The purpose of this study was to determine the effect of contralateral hip adduction (CHA) on thickness of lumbar stabilizers during hip abduction in side-lying. Twenty healthy subjects without back pain were recruited for this study. The thickness of transverse abdominis (TrA), internal oblique (IO) and quadratus lumborum (QL) were measured by ultrasonography. Pelvic lateral tilting motion was measured using a three-dimensional motion analysis system. Measurements were performed at rest position (RP), $35^{\circ}$preferred hip abduction (PHA) and $35^{\circ}$abduction with $10^{\circ}$contralateral hip adduction (CHA) in side-lying at the end of expiration. During the measurements, subjects were asked to maintain steady trunk alignment without hand support. Thickness of TrA and IO was significantly greater in CHA than in PHA and RP conditions. There was no significant difference in thickness of TrA and IO between PHA and RP conditions. Medio-lateral (M-L) thickness of QL was not significant between PHA and CHA conditions. Anterio-posterior (A-P) thickness of QL in PHA and CHA significantly decreased compared to RP condition. Angle of pelvic lateral tilting was significantly decreased in CHA compared to PHA condition. In conclusion, CHA can be recommended for increasing trunk stability without compensatory pelvic motion during hip abduction exercise in side-lying.

Technical Performance of Two-Dimensional Shear Wave Elastography for Measuring Liver Stiffness: A Systematic Review and Meta-Analysis

  • Dong Wook Kim;Chong Hyun Suh;Kyung Won Kim;Junhee Pyo;Chan Park;Seung Chai Jung
    • Korean Journal of Radiology
    • /
    • v.20 no.6
    • /
    • pp.880-893
    • /
    • 2019
  • Objective: To assess the technical performance of two-dimensional shear wave elastography (2D-SWE) for measuring liver stiffness. Materials and Methods: The Ovid-MEDLINE and EMBASE databases were searched for studies reporting the technical performance of 2D-SWE, including concerns with technical failures, unreliable measurements, interobserver reliability, and/or intraobserver reliability, published until June 30, 2018. The pooled proportion of technical failure and unreliable measurements was calculated using meta-analytic pooling via the random-effects model and inverse variance method for calculating weights. Subgroup analyses were performed to explore potential causes of heterogeneity. The pooled intraclass correlation coefficients (ICCs) for interobserver and intraobserver reliability were calculated using the Hedges-Olkin method with Fisher's Z transformation of the correlation coefficient. Results: The search yielded 34 articles. From 20 2D-SWE studies including 6196 patients, the pooled proportion of technical failure was 2.3% (95% confidence interval [CI], 1.3-3.9%). The pooled proportion of unreliable measurements from 20 studies including 6961 patients was 7.5% (95% CI, 4.7-11.7%). In the subgroup analyses, studies conducting more than three measurements showed fewer unreliable measurements than did those with three measurements or less, but no intergroup difference was found in technical failure. The pooled ICCs for interobserver reliability (from 10 studies including 517 patients) and intraobserver reliability (from 7 studies including 679 patients) were 0.87 (95% CI, 0.82-0.90) and 0.93 (95% CI, 0.89-0.95), respectively, suggesting good to excellent reliability. Conclusion: 2D-SWE shows good technical performance for assessing liver stiffness, with high technical success and reliability. Future studies should establish the quality criteria and optimal number of measurements.

Preliminary study on the effects of pergolide on left ventricular function in the horses with pituitary pars intermedia dysfunction

  • Gehlen, Heidrun;Fisch, Judith;Merle, Roswitha;Trachsel, Dagmar S.
    • Journal of Veterinary Science
    • /
    • v.22 no.5
    • /
    • pp.64.1-64.12
    • /
    • 2021
  • Background: Pituitary pars intermedia dysfunction (PPID), a neurodegenerative disease leading to reduced dopamine production, is a common disease in aged horses. The treatment is based on administration of the dopamine agonist pergolide. This drug has been related to valvular fibrosis in humans, but the cardiovascular effect of this drug has not yet been investigated in horses. Objectives: To determine whether pergolide induces valvular disease in horses or affects the cardiac function. Methods: Standard, tissue Doppler (TDE) and two-dimensional speckle tracking (STE) echocardiography were performed in horses with diagnosed PPID based on adrenocorticotropic hormone dosage. Measurements taken in horses treated with pergolide were compared with those from untreated horses with nonparametric t-tests. Furthermore, measurements from follow-up examinations performed at least three months after the initial exam were compared with a Wilcoxon signed rank test for repeated measurements in each group. Results: Twenty-three horses were included. None of the 12 horses under treatment developed valvular regurgitation. Furthermore, no differences in the measurements of the left ventricular systolic or diastolic function could be seen between the group of horses with treatment and those without treatment. Measurements taken in the follow-up exam did not differ compared to those taken in the initial exam in both groups. Conclusions: No changes of the left ventricular function assessed by TDE and STE could be shown in a small population of horses with confirmed PPID. Treatment with pergolide did not affect the ventricular function nor induce valvular disease.

Comparison of Diagnostic Accuracies of Serum HE-4 Levels and 3D Power Doppler Angiography Parameters between Benign Endometrial Pathologies and Endometrial Cancer

  • Erenel, Hakan;Bese, Tugan;Sal, Veysel;Demirkiran, Fuat;Arvas, Macit
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.5
    • /
    • pp.2507-2511
    • /
    • 2016
  • Purpose: To study the diagnostic accuracies of serum human epididymis protein 4 (HE-4) levels, virtual organ computer-aided analysis (VOCAL) parameters and endometrial volume in endometrial cancer cases. Materials and Methods: One hundred and seven patients (37 with endometrial cancer and 70 with benign endometrial pathology) were included in this study. VOCAL parameters and serum HE-4 levels were compared between the groups. Results: Area under the curve (AUC) values were 0.702, 0.658, 0.706 for vascularization index (VI), the flow index (FI) and the vascularization flow index (VFI), respectively. A cut off value of 0.568 for VI demonstrated 70% sensitivity, 72% specificity, 56% positive predictive value (PPV) and a81% negative predictive value (NPV). A cut off value of 25.8 for showed a senitivith of 70% and a specificity of 58% with aPPV of 46% and NPV of 78%, and with a cut off value of 0.12 for VFI 70%, 69%, 54% and 81%, respectively. The area under the curve for HE-4 was 0.814. A cut off value of 458 pmol/L was predictive of malignancy with 86% sensitivity and 63% specificity. Conclusions: VOCAL parameters and serum HE-4 levels were statistically significantly higher in the endometrial cancer patients. Serum HE-4 levels provided a greater sensitivity compared to power doppler angiography for predicting malignancy or benign endometrial pathology.

Use of real-time ultrasound imaging for biofeedback of diaphragm motion during normal breathing in healthy subjects

  • Cho, Ji-Eun;Hwang, Dal-Yeon;Hahn, Joohee;Lee, Wan-Hee
    • Physical Therapy Rehabilitation Science
    • /
    • v.7 no.3
    • /
    • pp.95-101
    • /
    • 2018
  • Objective: To determine if the provision of visual biofeedback using real-time rehabilitative ultrasound imaging (RUSI) enhances the acquisition and retention of diaphragm muscle recruitment during exercise. Design: Two group pretest posttest design. Methods: Thirty healthy subjects were randomly assigned to the verbal feedback group (VG, n=15) or the visual and verbal feedback group (VVG, n=15). The VG performed breathing exercises 10 times with verbal feedback, and the VVG also performed breathing exercises 10 times with verbal feedback and visual feedback with the use of RUSI to measure changes in diaphragm thickness (DT). For DT, the mid-axillary lines between ribs 8 and 9 on both sides were measured in standing, and then the chest wall was perpendicularly illuminated using a linear transducer with the patients in supine to observe the region between rib 8 and 9 and to obtain 2-dimensional images. DT was measured as the distance between the two parallel lines that appeared bright in the middle of the pleura and the peritoneum. After one week, three repetitions (follow-up session) were performed to confirm retention effects. Intra- and between- group percent changes in diaphragm muscle thickness were assessed. Results: In the VVG, the intervention value had a medium effect size compared to the baseline value, but the follow-up value decreased to a small effect size. In the between-group comparisons, during the intervention session, the VVG showed no significant effect on percent change of DT but had a medium effect size compared to the VG (p=0.050, Cohen's d=0.764). During the follow-up session, retention effect did not persist (p=0.311, Cohen's d=0.381). Conclusions: RUSI can be used to provide visual biofeedback and improve performance and retention in the ability to activate the diaphragm muscle in healthy subjects. Future research needs to establish a protocol for respiratory intervention to maintain the effect of diaphragmatic breathing training using RUSI with visual feedback.

Laparoscopic Operation for Superior Mesenteric Artery Syndrome and Follow-up with 3-Dimensional Reconstructive CT - 1 Case Report - (상장간막동맥 증후군의 복강경 수술 및 3차원재건 복부 전산화단층촬영 영상을 이용한 추적관찰 -1예보고-)

  • Kim, Seong-Min;Kim, Sung-Hoon;Kwon, In-Kyou;Kim, Myoung-Joon;Hyoung, Woo-Jin;Choi, Seung-Hoon
    • Advances in pediatric surgery
    • /
    • v.11 no.2
    • /
    • pp.180-185
    • /
    • 2005
  • Superior mesenteric artery (SMA) syndrome is a rare disorder caused by extrinsic compression of the third portion of the duodenum by the SMA. The operative treatment of choice is bypassing the obstructed duodenal segment by duodenojejunostomy. We report one case of SMA syndrome treated by laparoscopic duodenojejunostomy and followed up by 3D-reconstructive CT scan. A fifteen-year-old boy with intermittent vomiting and weight loss was admitted. Ultrasonography showed narrowing of the distance between the SMA and aorta. Hypotonic duodenography showed dilatation of duodenal third portion and barium stasis. On 3Dreconstructive CT scan, the angle between SMA and aorta was $37^{\circ}$. The postoperative course was uneventful. Three months later, he had gained 3 kg of weight and the angle between SMA and aorta increased to $38-39^{\circ}$ on 3D reconstructive CT scan. Laparoscopic duodenojejunostomy for bypassing the obstructive duodenum in SMA syndrome is a feasible and safe method.

  • PDF

Measurement of S1 foramen depth for ultrasound-guided S1 transforaminal epidural injection

  • Ye Sull Kim;SeongOk Park;Chanhong Lee;Sang-Kyi Lee;A Ram Doo;Ji-Seon Son
    • The Korean Journal of Pain
    • /
    • v.36 no.1
    • /
    • pp.98-105
    • /
    • 2023
  • Background: Ultrasound-guided first sacral transforaminal epidural steroid injection (S1 TFESI) is a useful and easily applicable alternative to fluoroscopy or computed tomography (CT) in lumbosacral radiculopathy. When a needle approach is used, poor visualization of the needle tip reduces the accuracy of the procedure, increasing its difficulty. This study aimed to improve ultrasound-guided S1 TFESI by evaluating radiological S1 posterior foramen data obtained using three-dimensional CT (3D-CT). Methods: Axial 3D-CT images of the pelvis were retrospectively analyzed. The radiological measurements obtained from the images included 1st posterior sacral foramen depth (S1D, mm), 1st posterior sacral foramen width (S1W, mm), the angle of the 1st posterior sacral foramen (S1A, °), and 1st posterior sacral foramen distance (S1ds, mm). The relationship between the demographic factors and measured values were then analyzed. Results: A total of 632 patients (287 male and 345 female) were examined. The mean S1D values for males and females were 11.9 ± 1.9 mm and 10.6 ± 1.8 mm, respectively (P < 0.001); the mean S1A 28.2 ± 4.8° and 30.1 ± 4.9°, respectively (P < 0.001); and the mean S1ds, 24.1 ± 2.9 mm and 22.9 ± 2.6 mm, respectively (P < 0.001); however, the mean S1W values were not significantly different. Height was the only significant predictor of S1D (β = 0.318, P = 0.004). Conclusions: Ultrasound-guided S1 TFESI performance and safety may be improved with adjustment of needle insertion depth congruent with the patient's height.