• Title/Summary/Keyword: Three dimensional image

Search Result 1,511, Processing Time 0.035 seconds

Enhancement Pattern of the Normal Facial Nerve on Three - Dimensional (3D) - Fluid Attenuated Inversion Recovery (FLAIR) Sequence at 3.0 T MR Units (3.0T 자기공명영상기기에서 시행한 3D-FLAIR 영상에서의 정상 안면신경의 조영증강 양상)

  • Hyun, Dong-Ho;Lim, Hyun-Kyung;Park, Jee-Won;Kim, Jong-Lim;Lee, Ha-Young;Park, Soon-Chan;Ahn, Joong-Ho;Baek, Jung-Hwan;Choi, Choong-Gon;Lee, Jeong-Hyun
    • Investigative Magnetic Resonance Imaging
    • /
    • v.16 no.1
    • /
    • pp.25-30
    • /
    • 2012
  • Purpose : To compare the enhancement pattern of normal facial nerves on 3D-FLAIR and 3D-T1-FFE-F) sequences at 3.0 T MR units. Materials and Methods: We assessed 20 consecutive subjects without a history of facial nerve abnormalities who underwent temporal bone MRI with contrast enhancement between January 2008 and March 2009. Two neuroradiologists independently reviewed pre-/post-enhanced 3D-T1-FFE-FS and 3D-FLAIR images respectively with 2-week interval to assess the enhancement of normal facial nerves divided into five anatomical segments. The degree of enhancement in each segment was graded as none, mild or strong, and the results of 3D-FLAIR and 3D-T1-FFE-FS image sets were compared. Results: On 3D-FLAIR images, one of the two reviewers observed mild enhancement of the genu segment in two (10%) subjects. On 3D-T1-FFE-FS images, at least one segment of the facial nerve was enhanced in 13 (65%) subjects. At least one reviewer found that 17 of the 100 segments showed enhancement on 3D-T1-FFE-FS images, with the mastoid segment being the most commonly enhanced. Interobserver agreement on 3D-T1-FFE-FS images was good for enhancement of the normal facial nerve (${\kappa}$= 0.589). Conclusion: In contrast to 3D-T1-FFE-FS, normal facial nerve segments rarely showed enhancement on 3D-FLAIR images.

Modernist painting style in Disney animation (디즈니 애니메이션에 나타난 모더니즘 회화스타일 : 색, 형태, 공간을 중심으로)

  • Moon, Jae-Cheol;Kim, Yu-Mi
    • Cartoon and Animation Studies
    • /
    • s.33
    • /
    • pp.31-53
    • /
    • 2013
  • In the early twentieth century, history of animation began by modern artists, they produced various experimental images with the newly invented film and cameras. Artists in the field of movie, photography, paintings and others manipulated images in motion. But as some animated movies won industrial success and popularity, they became the trend but experimental style of early animation preserved by so-called non-mainstreamers or experimental animators, counteracting commercialism. Disney animation also followed the trend by applying realistic Hollywood film style, the worse critics placed a low value on the animation and it tarnished the image, although it was profitable investment from a business standpoint. To make images realistic, they opened a drawing class that animators developed skills to imitate motions and forms from subjects in real life. Also some techniques and gizmos were used to mimic and simulate three dimensional objects and spaces, multiplane camera and compositing 3D CG images with 2D drawings. Moreover, they brought animation stories from fairly tales or folk tales, and Walt's personal interest in live-action movies, they applied Hollywood-film-like narratives and realistic visual, and harsh criticism ensued. On the surface early disney animations' potential seems to be weakened, but in reality it still exists by simplifying and exaggerating forms and color as modern arts. Disney animation employs concepts of the modernism paintings such as simplified shapes and colors to a character design, when their characters are placed together in a scene, that visual elements cause mental reaction. This modification gives a new internal experience to audiences. As conceptual colors in abstract paintings make images appeared to be flat, coloring characters with no shading make them look flat and comparing to them, background images are also appeared to be flat. On top of that, multi-perspective at background images recalls modernist paintings. This essay goes in details with the animation pioneers' works and how Disney animation developed its techniques to emulate real life and analyses color schemes, forms, and spaces in Disney animation compared with modern artists' works, in that the visual language of Disney animation reminds of impression from abstract paintings in the beginning of the twentieth centuries.

Absorbed Dose and Effective Dose for Lung Cancer Image Guided Radiation Therapy(IGRT) using CBCT and 4D-CBCT (폐암 영상유도방사선 치료 시 CBCT와 4D-CBCT를 이용한 흡수선량 및 유효선량에 관한 선량 평가)

  • Kim, Dae yong;Lee, Woo Suk;Koo, Ki Lae;Kim, Joo Seob;Lee, Sang Hyeon
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.28 no.1
    • /
    • pp.57-64
    • /
    • 2016
  • Purpose : To evaluate the results of absorbed and effective doses using CBCT and 4D-CBCT settings for lung cancer. Materials and Methods : This experimental study. Measurements were performed using a Anderson rando phantom with OSLD(optically stimulated luminescent dosimeters). It was performed computed tomography(Lightspeed GE, USA) in order to express the major organs of the human body. Measurements were obtained a mean value is repeated three times each. Evaluations of effective dose and absorbed dose were performed the CL-IX-Thorax mode and Truebeam-Thorax mode CBCT. Additionally, compared Truebeam-Thorax mode CBCT with Truebeam-Thorax mode 4D-CBCT(Four-dimensional Cone Beam Computed Tomography) Results : Average absorbed dose in the CBCT of CL-IX was measured in lung 2.505cGy, heart 2.595cGy, liver 2.145cGy, stomach 1.934cGy, skin 2.233cGy, in case of Truebeam, It was measured lung 1.725cGy, heart 2.034cGy, liver 1.616cGy, stomach 1.470cGy, skin 1.445cGy. In case of 4D-CBCT, It was measured lung 3.849cGy, heart 4.578cGy, liver 3.497cGy, stomach 3.179cGy, skin 3.319cGy Average effective dose, considered tissue weighting and radiation weighting, in the CBCT of CL-IX was measured lung 2.164mSv, heart 2.241mSVv, liver 0.136mSv, stomach 1.668mSv, skin 0.009mSv, in case of Turebeam, it was measured lung 1.725mSv, heart 1.757mSv, liver 0.102mSv, stomach 1.270mSv, skin 0.005mSv, In case of 4D-CBCT, It was measured lung 3.326mSv, heart 3.952mSv, liver 0.223mSv, stomach 2.747mSv, skin 0.013mSv Conclusion : As a result, absorbed dose and effective Dose in the CL-IX than Truebeam was higher about 1.3 times and in the 4D-CBCT Truebeam than CBCT of Truebeam was higher about 2.2times However, a large movement of the patient and respiratory gated radiotherapy may be more accurate treatment in 4D-CBCT. Therefore, it will be appropriate to selectively used.

  • PDF

Evaluation of Magnetization Transfer Ratio Imaging by Phase Sensitive Method in Knee Joint (슬관절 부위에서 자화전이 위상감도법에 의한 자화전이율 영상 평가)

  • Yoon, Moon-Hyun;Seung, Mi-Sook;Choe, Bo-Young
    • Progress in Medical Physics
    • /
    • v.19 no.4
    • /
    • pp.269-275
    • /
    • 2008
  • Although MR imaging is generally applicable to depict knee joint deterioration it, is sometimes occurred to mis-read and mis-diagnose the common knee joint diseases. In this study, we employed magnetization transfer ratio (MTR) method to improve the diagnosis of the various knee joint diseases. Spin-echo (SE) T2-weighted images (TR/TE 3,400-3,500/90-100 ms) were obtained in seven cases of knee joint deterioration, FSE T2-weighted images (TR/TE 4,500-5,000/100-108 ms) were obtained in seven cases of knee joint deterioration, gradient-echo (GRE) T2-weighted images (TR/TE 9/4.56/$50^{\circ}$ flip angle, NEX 1) were obtained in 3 cases of knee joint deterioration, In six cases of knee joint deterioration, fat suppression was performed using a T2-weighted short T1/tau inverse recovery (STIR) sequence (TR/TE =2,894-3,215 ms/70 ms, NEX 3, ETL 9). Calculation of MTR for individual pixels was performed on registration of unsaturated and saturated images. After processing to make MTR images, the images were displayed in gray color. For improving diagnosis, three-dimensional isotropic volume images, the MR tristimulus color mapping and the MTR map was employed. MTR images showed diagnostic images quality to assess the patients' pathologies. The intensity difference between MTR images and conventional MRI was seen on the color bar. The profile graph on MTR imaging effect showed a quantitative measure of the relative decrease in signal intensity due to the MT pulse. To diagnose the pathologies of the knee joint, the profile graph data was shown on the image as a small cross. The present study indicated that MTR images in the knee joint were feasible. Investigation of physical change on MTR imaging enables to provide us more insight in the physical and technical basis of MTR imaging. MTR images could be useful for rapid assessment of diseases that we examine unambiguous contrast in MT images of knee disorder patients.

  • PDF

A line study on movement expression in Dragonball of Toriyama Akira (토리야마 아키라의 <드래곤볼>에 나타난 운동표현에 관한 선 연구)

  • Cho, Dai-Ho;Park, Keong-Cheol
    • Cartoon and Animation Studies
    • /
    • s.31
    • /
    • pp.153-176
    • /
    • 2013
  • In the early 20th century, the some of futurist painter was attempted to represents the 'fast-paced' and 'dynamism' on a two-dimensional picture. The expression of fast-paced and dynamic for look like move image in the painting have evolved as a variety of visual symbol. Visual symbols that represent these movements were settled as the line of the most movement expression in the comic. The of Toriyama Akira gained worldwide popularity is emphasized speed and dynamism as the action genre in cartoon, is nice a data to research the line of the movement expression of cartoon. There is three terms as the action line, The speed line, the effect line on the movement expression in The glossary of in the dictionary of , but it not easy to Separate them by means similar. This study is willing to says the semantically problem of previous lines on the movement expression and to present a new alternative in order to study the line on the movement expression of . This study Separate the line on movement expression from symbolic the perspective and try to newly define by using, was classified lines of four kinds by add the afterimage line on existing the speed line, the motion line, the effect line. First, the speed line was defined as 'The line expressing the movement expression of a moving target as the concept of speed'. It on the way of expression was subdivided the direct as speed line when it alter the shape of the target and the indirect speed line when it alter the background of the target. Second, the motion line was defined as 'The line simplified the moving form or the moving path of moving target'. Third, the effect line was defined as 'the line emphasizing the movement expression of a moving target by Sensory expression or emotional expression. Fourth, the afterimage lines was defined as 'The line expressing slowly moving or swaying the movement expression of target to the afterimage effect. The terminology presented in this study will be able to help the understanding of the line on the movement expression .

STRESS ANALYSIS OF SUPPORTING TISSUES ACCORDING TO IMPLANT FIXTURE DIAMETER AND RESIDUAL ALVEOLAR BONE WIDTH (치조골 폭경과 임플랜트 고정체의 직경에 따른 지지조직의 응력분포)

  • Han, Sang-Un;Vang, Mong-Sook;Yang, Hong-So;Park, Sang-Won;Park, Ha-Ok;Lim, Hyun-Pil
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.4
    • /
    • pp.506-521
    • /
    • 2007
  • Statement of problem: The cumulative success rate of wide implant is still controversial. Some previous reports have shown high success rate, and some other reports shown high failure rate. Purpose: The aim of this study was to analyze, and compare the biomechanics in wide implant system embeded in different width of crestal bone under different occlusal forces by finite element approach. Material and methods: Three-dimensional finite element models were created based on tracing of CT image of second premolar section of mandible with one implant embedded. One standard model (6mm-crestal bone width, 4.0mm implant diameter central position) was created. Varied crestal dimension(4, 6, 8 mm), different diameter of implants(3.3, 4.0, 5.5, 6.0mm), and buccal position implant models were generated. A 100-N vertical(L1) and 30 degree oblique load from lingual(L2) and buccal(L3) direction were applied to the occlusal surface of the crown. The analysis was performed for each load by means of the ANSYS V.9.0 program. Conclusion: 1. In all cases, maximum equivalent stress that applied $30^{\circ}$ oblique load around the alveolar bone crest was larger than that of the vertical load. Especially the equivalent stress that loaded obliquely in buccal side was larger. 2. In study of implant fixture diameter, stress around alveolar bone was decreased with the increase of implant diameter. In the vertical load, as the diameter of implant increased the equivalent stress decreased, but equivalent stress increased in case of the wide implant that have a little cortical bone in the buccal side. In the lateral oblique loading condition, the diameter of implant increased the equivalent stress decreased, but in the buccal oblique load, there was not significant difference between the 5.5mm and 6.0mm as the wide diameter implant. 3. In study of alveolar bone width, equivalent stress was decreased with the increase of alveolar bone width. In the vertical and oblique loading condition, the width of alveolar bone increased 6.0mm the equivalent stress decreased. But in the oblique loading condition, there was not a difference equivalent stress at more than 6.0mm of alveolar bone width. 4. In study of insertion position of implant fixture, even though the insertion position of implant fixture move there was not a difference equivalent stress, but in the case of little cortical bone in the buccal side, value of the equivalent stress was most unfavorable. 5. In all cases, it showed high stress around the top of fixture that contact cortical bone, but there was not a portion on the bottom of fixture that concentrate highly stress and play the role of stress dispersion. These results demonstrated that obtaining the more contact from the bucco-lingual cortical bone by installing wide diameter implant plays an important role in biomechanics.

Estimation of $T_2{^*}$ Relaxation Times for the Glandular Tissue and Fat of Breast at 3T MRI System (3테슬러 자기공명영상기기에서 유방의 유선조직과 지방조직의 $T_2{^*}$이완시간 측정)

  • Ryu, Jung Kyu;Oh, Jang-Hoon;Kim, Hyug-Gi;Rhee, Sun Jung;Seo, Mirinae;Jahng, Geon-Ho
    • Investigative Magnetic Resonance Imaging
    • /
    • v.18 no.1
    • /
    • pp.1-6
    • /
    • 2014
  • Purpose : $T_2{^*}$ relaxation time which includes susceptibility information represents unique feature of tissue. The objective of this study was to investigate $T_2{^*}$ relaxation times of the normal glandular tissue and fat of breast using a 3T MRI system. Materials and Methods: Seven-echo MR Images were acquired from 52 female subjects (age $49{\pm}12 $years; range, 25 to 75) using a three-dimensional (3D) gradient-echo sequence. Echo times were between 2.28 ms to 25.72 ms in 3.91 ms steps. Voxel-based $T_2{^*}$ relaxation times and $R_2{^*}$ relaxation rate maps were calculated by using the linear curve fitting for each subject. The 3D regions-of-interest (ROI) of the normal glandular tissue and fat were drawn on the longest echo-time image to obtain $T_2{^*}$ and $R_2{^*}$ values. Mean values of those parameters were calculated over all subjects. Results: The 3D ROI sizes were $4818{\pm}4679$ voxels and $1455{\pm}785$ voxels for the normal glandular tissue and fat, respectively. The mean $T_2{^*}$ values were $22.40{\pm}5.61ms$ and $36.36{\pm}8.77ms$ for normal glandular tissue and fat, respectively. The mean $R_2{^*}$ values were $0.0524{\pm}0.0134/ms$ and $0.0297{\pm}0.0069/ms$ for the normal glandular tissue and fat, respectively. Conclusion: $T_2{^*}$ and $R_2{^*}$ values were measured from human breast tissues. $T_2{^*}$ of the normal glandular tissue was shorter than that of fat. Measurement of $T_2{^*}$ relaxation time could be important to understand susceptibility effects in the breast cancer and the normal tissue.

High-Resolution Contrast-Enhanced 3D-Spoiled Gradient-Recalled Imaging for Evaluation of Intracranial Vertebral Artery and Posterior Inferior Cerebellar Artery in Lateral Medullary Infarction (고해상도 조영증강 삼차원 회손기울기 회상 영상을 이용한 측면연수경색 환자의 두개내 척추동맥 및 뒤아래소뇌동맥 평가)

  • Yoon, Youngno;Ahn, Sung Jun;Suh, Sang Hyun;Park, Ah Young;Chung, Tae-Sub
    • Investigative Magnetic Resonance Imaging
    • /
    • v.18 no.1
    • /
    • pp.17-24
    • /
    • 2014
  • Purpose : To determine whether high-resolution contrast-enhanced three dimensional imaging with spoiled gradient-recalled sequence (HR-CE 3D-SPGR) plays a meaningful role in the assessment of intracranial vertebral artery (ICVA) and posterior inferior cerebellar artery (PICA) in lateral medullary infarction (LMI). Materials and Methods: Twenty-five patients confirmed with LMI were retrospectively enrolled with approval by the IRB of our institute, and 3T MRI with HR-CE 3D-SPGR and contrast-enhanced magnetic resonance angiography (CE-MRA) were performed. Two radiologists who were blinded to clinical information and other brain MR images including diffusion weighted image independently evaluated arterial lesions in ICVA and PICA. The demographic characteristics, the area of LMI and cerebellar involvement were analyzed and compared between patients with arterial lesion in ICVA only and patients with arterial lesions in both ICVA and PICA on HR-CE 3D-SPGR. Results: Twenty-two of twenty-five LMI patients had arterial lesions in ICVA or PICA on HR-CE 3D SPGR. However twelve arterial lesions in PICA were not shown on CE-MRA. Concurrent cerebellar involvement appeared more in LMI patients with arterial lesion in ICVA and PICA than those with arterial lesion in ICVA alone (p = 0.069). Conclusion: HR-CE 3D-SPGR can help evaluate arterial lesions in ICVA and PICA for LMI patients.

The Effect of Manufacturing Method Preferences for Different Product Types on Purchase Intent and Product Quality Perception (제품유형에 따른 제조방식 선호가 구매의도와 품질지각에 미치는 효과)

  • Lee, Guk-Hee;Park, Seong-Yeon
    • Science of Emotion and Sensibility
    • /
    • v.19 no.4
    • /
    • pp.21-32
    • /
    • 2016
  • Studies have observed various phenomena regarding the effect of the interaction between type, price, and brand image of a product on consumers' purchase intent and product quality perception. Yet, few have studied the effect of the interaction between product type and manufacturing method on these factors. However, the advent of three-dimensional (3D) printers added a new manufacturing method, 3D printing, to the traditional methods of handicraft and automated machine-based production, and research is necessary since this new framework might affect consumers' purchase intent and product quality perception. Therefore, this study aimed to verify the effects of the interaction between product type and manufacturing method on purchase intent and product quality perception. To achieve this, in our experiment 1, we selected product types with different characteristics (drone vs. violin vs. cup), and measured whether consumers preferred different manufacturing methods for each product type. The results showed that consumers preferred the 3D printing method for technologically advanced products such as drones, the handmade method for violins, and the automated machine-based manufacturing method, which allows mass production, for cups. Experiment 2 attempted to verify the effects of the differences in manufacturing method preferences for each product type on consumers' purchase intent and product quality perception. Our findings are as follows: for drones, the purchase intent was highest when 3D printing was used; for violins, the purchase intent was highest when the violins were handmade; for cups, the purchase intent was highest when machine-based manufacturing was used. Moreover, whereas the product quality perception for drones did not differ across different manufacturing methods, consumers perceived that handmade violins had the highest quality and that cups manufactured with 3D printing had the lowest quality (the purchase intent for cups was also lowest when 3D printing was used). This study is anticipated to provide a wide range of implications in various areas, including consumer psychology, marketing, and advertising.

A Study of Anomaly Detection for ICT Infrastructure using Conditional Multimodal Autoencoder (ICT 인프라 이상탐지를 위한 조건부 멀티모달 오토인코더에 관한 연구)

  • Shin, Byungjin;Lee, Jonghoon;Han, Sangjin;Park, Choong-Shik
    • Journal of Intelligence and Information Systems
    • /
    • v.27 no.3
    • /
    • pp.57-73
    • /
    • 2021
  • Maintenance and prevention of failure through anomaly detection of ICT infrastructure is becoming important. System monitoring data is multidimensional time series data. When we deal with multidimensional time series data, we have difficulty in considering both characteristics of multidimensional data and characteristics of time series data. When dealing with multidimensional data, correlation between variables should be considered. Existing methods such as probability and linear base, distance base, etc. are degraded due to limitations called the curse of dimensions. In addition, time series data is preprocessed by applying sliding window technique and time series decomposition for self-correlation analysis. These techniques are the cause of increasing the dimension of data, so it is necessary to supplement them. The anomaly detection field is an old research field, and statistical methods and regression analysis were used in the early days. Currently, there are active studies to apply machine learning and artificial neural network technology to this field. Statistically based methods are difficult to apply when data is non-homogeneous, and do not detect local outliers well. The regression analysis method compares the predictive value and the actual value after learning the regression formula based on the parametric statistics and it detects abnormality. Anomaly detection using regression analysis has the disadvantage that the performance is lowered when the model is not solid and the noise or outliers of the data are included. There is a restriction that learning data with noise or outliers should be used. The autoencoder using artificial neural networks is learned to output as similar as possible to input data. It has many advantages compared to existing probability and linear model, cluster analysis, and map learning. It can be applied to data that does not satisfy probability distribution or linear assumption. In addition, it is possible to learn non-mapping without label data for teaching. However, there is a limitation of local outlier identification of multidimensional data in anomaly detection, and there is a problem that the dimension of data is greatly increased due to the characteristics of time series data. In this study, we propose a CMAE (Conditional Multimodal Autoencoder) that enhances the performance of anomaly detection by considering local outliers and time series characteristics. First, we applied Multimodal Autoencoder (MAE) to improve the limitations of local outlier identification of multidimensional data. Multimodals are commonly used to learn different types of inputs, such as voice and image. The different modal shares the bottleneck effect of Autoencoder and it learns correlation. In addition, CAE (Conditional Autoencoder) was used to learn the characteristics of time series data effectively without increasing the dimension of data. In general, conditional input mainly uses category variables, but in this study, time was used as a condition to learn periodicity. The CMAE model proposed in this paper was verified by comparing with the Unimodal Autoencoder (UAE) and Multi-modal Autoencoder (MAE). The restoration performance of Autoencoder for 41 variables was confirmed in the proposed model and the comparison model. The restoration performance is different by variables, and the restoration is normally well operated because the loss value is small for Memory, Disk, and Network modals in all three Autoencoder models. The process modal did not show a significant difference in all three models, and the CPU modal showed excellent performance in CMAE. ROC curve was prepared for the evaluation of anomaly detection performance in the proposed model and the comparison model, and AUC, accuracy, precision, recall, and F1-score were compared. In all indicators, the performance was shown in the order of CMAE, MAE, and AE. Especially, the reproduction rate was 0.9828 for CMAE, which can be confirmed to detect almost most of the abnormalities. The accuracy of the model was also improved and 87.12%, and the F1-score was 0.8883, which is considered to be suitable for anomaly detection. In practical aspect, the proposed model has an additional advantage in addition to performance improvement. The use of techniques such as time series decomposition and sliding windows has the disadvantage of managing unnecessary procedures; and their dimensional increase can cause a decrease in the computational speed in inference.The proposed model has characteristics that are easy to apply to practical tasks such as inference speed and model management.