• Title/Summary/Keyword: Thoracic endovascular aortic repair

Search Result 65, Processing Time 0.029 seconds

Stented Aortic Graft Insertion in an Infrarenal Abdominal Aortic Aneurysm as Performed by Cardiovascular Surgeons - Report of 3 cases- (흉부외과 의사에 의해 시행된 복부 대동맥류의 스텐트 그라프트 삽입술 -3예 보고 -)

  • Chung, Eui-Suk;Lim, Cheong;Seong, Yong-Won;Choi, Jin-Ho;Park, Kay-Hyun;Chung, Woo-Young
    • Journal of Chest Surgery
    • /
    • v.41 no.3
    • /
    • pp.377-380
    • /
    • 2008
  • Abdominal aortic aneurysm has traditionally been treated by open repair. Aortic endovascular stent grafting has recently been introduced as a new modality. We report here on three cases of endovascular stent grafting that were performed by cardiovascular surgeons for the treatment of abdominal aortic aneurysm in the high risk patients with multiple comorbidities such as old age, hypertension, renal failure, cerebrovascular accident and immobility.

The Influence of Unfavorable Aortoiliac Anatomy on Short-Term Outcomes after Endovascular Aortic Repair

  • Lee, Jae Hang;Choi, Jin-Ho;Kim, Eung-Joong
    • Journal of Chest Surgery
    • /
    • v.51 no.3
    • /
    • pp.180-186
    • /
    • 2018
  • Background: Endovascular aortic repair (EVAR) is widely performed to treat infrarenal abdominal aortic aneurysms (AAAs), and related techniques and devices continue to be developed. Although continuous attempts have been made to perform EVAR in patients with unfavorable aortic anatomy, the outcomes are still controversial. This study examined the short-term outcomes of EVAR for the treatment of infrarenal AAAs in patients with a 'hostile' neck and unfavorable iliac anatomy. Methods: Thirty-eight patients who underwent EVAR from January 2012 to December 2017 were enrolled in this study. A hostile neck was defined based on neck length, angulation, the presence of an associated thrombus, or a conical shape. Unfavorable iliac anatomy was considered to be present in patients with a short common iliac artery (<15 mm) or the presence of aneurysmal changes. Results: No perioperative mortality was recorded. No significant differences were found depending on the presence of a hostile neck, but aneurysmal sac shrinkage was significantly less common in the group with unfavorable iliac anatomy (p=0.04). A multivariate analysis performed to analyze the risk factors for aneurysmal progression revealed only unfavorable iliac anatomy to be a risk factor (p=0.02). Conclusion: Patients with unfavorable aortic anatomy showed relatively satisfactory short-term outcomes after EVAR. No difference in the surgical outcomes was observed in patients with a hostile neck. However, unfavorable iliac anatomy was found to inhibit the shrinkage of the aneurysmal sac.

Aorta Remodeling after Endovascular Treatment of a Chronic DeBakey IIIb Aneurysm and Simultaneous Palliation of a Renal Cell Carcinoma

  • Kim, Do Jung;Lee, Kwang-Hun;Lim, Sun-Hee;Chung, Byung Ha;Song, Suk-Won
    • Journal of Chest Surgery
    • /
    • v.48 no.2
    • /
    • pp.142-145
    • /
    • 2015
  • We report the case of a patient with a chronic DeBakey type IIIb aneurysm who underwent thoracic endovascular aortic repair to seal the primary entry tear and stent-graft insertion to cover the re-entry tear at the renal artery. The procedure was performed in order to achieve complete thrombosis in the entire thoracoabdominal false lumen, leading to favorable aortic remodeling. Simultaneously, ethanol ablation and renal artery embolization were performed to treat a renal tumor suspicious of renal cell carcinoma. Radical nephrectomy then confirmed clear cell carcinoma. To the best of our knowledge, no other cases of this type have been reported in the Korean literature.

Hybrid Procedure for Aortic Arch Aneurysm: Arch Vessels Debranching andThoracic Endovascular Aortic Repair? -2 case Reports- (대동맥궁 대동맥류에서 Hybrid 술식의 적용 - 2예 보고 -)

  • Kim, Seok;Kwon, Oh-Choon;Lee, Sub;Cho, Jun-Woo;Bae, Chi-Hoon;Park, Ki-Sung
    • Journal of Chest Surgery
    • /
    • v.43 no.5
    • /
    • pp.529-533
    • /
    • 2010
  • Conventional surgery for aortic arch aneurysms have many postoperative complications and a high mortality rate due to prolonged cardiopulmonary bypass time, especially in high risk patients. In this report, we present two cases of a hybrid procedure that involves open brachiocephalic bypass with concomitant endovascular arch stent grafting in high risk patients with distal aortic arch aneurysm.

Percutaneous Endovascular Stent-graft Treatment for Aortic Disease in High Risk Patients: The Early and Mid-term Results (고위험군의 대동맥류 환자에서 경피적으로 삽입이 가능한 스텐트 그라프트를 이용한 치료: 조기 및 중기성적)

  • Choi, Jin-Ho;Lim, Cheong;Park, Kay-Hyun;Chung, Eui-Suk;Kang, Sung-Gwon;Yoon, Chang-Jin
    • Journal of Chest Surgery
    • /
    • v.41 no.2
    • /
    • pp.239-246
    • /
    • 2008
  • Background: Aortic surgery for high risk patients has high mortality and morbidity rates, and the necessity of performing aortic surgery in cancer patients is questionable because of their short life expectancy. Endovascular repair of aneurysm repair can be considered for high risk patients and cancer patients because it has relatively lower invasiveness and shorter recovery times than aortic surgery does. Especially, percutaneous endovascular stent graft treatment is more useful for high risk patients because it does not require general anesthesia. Material and Method: From July 2003 to September 2007, twelve patients who had inoperable malignancy or who had a high risk of complication because of their combined diseases during aortic surgery underwent endovascular aortic aneurysm repair. he indications for endovascular repair were abdominal aortic aneurysm in 5 patients, descending thoracic aortic aneurysm in 6 patients and acute type B aortic dissection in one patient. The underlying combined disease of these patients were malignancy in 3 patients, respiratory disease in 6 patients, old age with neurologic disease in 6 patients, Behcet's iseae in one patient and chronic renal failure in one patient. Result: Stent grafts were inserted percutaneously in all cases. There were 4 hospital deaths and there were 3 delayed deaths during the follow-up periods. There were no deaths from aortic disease, except one hospital death. There were several complications: a mild cerebrovascular accident occurred in one patient, acute renal failure occurred in 2 patients and ischemic bowel necrosis occurred in one patient. Mild type I endoleak was observed in 2 patients and type II endoleak was observed in a patient after stent graft implantation. Newly developed type I endoleak was observed in a patient during the follow-up period. Conclusion: Percutaneous endovascular stent graft insertion is relatively safe procedure for high risk patients and cancer patients. Yet it seems that its indications and its long term results need to be further researched.

Management of Thoracic Aortic Injury after Blunt Trauma: Nine Cases at a Single Medical Center

  • Lee, Kyungwon;Lee, Jae Gil
    • Journal of Trauma and Injury
    • /
    • v.29 no.4
    • /
    • pp.146-150
    • /
    • 2016
  • Purpose: Traumatic aortic injuries are rare, but life threatening condition. They usually occur after high velocity impact on the chest or abdomen such as traffic accident or fall. We report the experiences of the traumatic aortic injuries at a single center. Methods: We retrospectively reviewed the medical records of nine patients with aortic injury resulting from the blunt trauma from Jan. 2010 to May. 2016. Results: The mean age was $51.1{\pm}20.8$ years old, and ten (90.9%) were men. The mechanisms of injury were traffic accidents in seven patients (motorcycle accidents; 3, car accidents; 4), and four in fall injury. Most common injured sites were thoracic aorta (9, 81.8%). Aortic injuries were repaired by endovascular approach in four patients, and by open graft surgery in four. Two patients were managed conservatively. Nine patients survived without any complications. Conclusion: We had experienced different approaches for management of aortic injuries after blunt trauma according to locations and severity of lesions.

Thoracic EndoVascular Stent Graft Repair for Aortic Aneurysm

  • Kim, Joung-Taek;Yoon, Yong-Han;Lim, Hyun-Kyung;Yang, Ki-Hwan;Baek, Wan-Ki;Kim, Kwang-Ho
    • Journal of Chest Surgery
    • /
    • v.44 no.2
    • /
    • pp.148-153
    • /
    • 2011
  • Background: The number of cases employing thoracic endovascular aortic repair (TEVAR) has been increasing due to lower morbidity and mortality compared to open repair technique. The aim of this study is to evaluate the outcome of TEVAR for thoracic aortic diseases. Materials and Methods: Sixteen patients underwent TEVAR from October 2003 to April 2010. Mean age at operation was 59 years (20~78 years), and 11 were male. Indications for TEVAR were large aortic diameter (>5.5 cm) upon presentation in 6 patients, increasing aortic diameter during the follow-up period in 4, traumatic aortic rupture in 3, persistent chest pain in 2, and ruptured aortic aneurysm in one. The mean diameter, length and the number of the stents were 33 mm (26~40 mm), 12 cm (9.5~16.0 cm), and 1.25 (1~2), respectively. Aortography employing Multi-detector computerized tomography (MDCT) technique was performed at one week, and patients were followed up in the out-patient department at one month, 6 months, and one year postoperatively. Results: Primary technical success showing complete exclusion of the aneurysm was achieved in 15 patients. One patient showed a small endo-leak (type 1). Four patients developed perioperative stroke: Three recovered without sequelae, and one showed mild right-side weakness. There was no operative mortality. Diameter of the thoracic aorta covered by stent graft changed within 10% range in 12 patients, decreased by more than 10% in 3, and increased by more than 10% in one during mean follow-up duration of 18 months (1~73 months). There was no recurrence-related death during this period. Conclusion: Intermediate-term outcome after TEVAR was encouraging. Indications for TEVAR could be extended for other thoracic aortic diseases.

Hybrid Procedure for Aortic Arch Repair: Arch Vessels Debranching with Supraaortic Revascularization Followed by Endovascular Aortic Stent Grafting (대동맥궁 대동맥류에서 Hybrid 수술적 치료)

  • Moon, Duk-Hwan;Chung, Cheol-Hyun;Kim, Hee-Jung
    • Journal of Chest Surgery
    • /
    • v.42 no.4
    • /
    • pp.520-523
    • /
    • 2009
  • Aortic arch aneurysm generally requires an urgent treatment due to the risk of catastrophic aortic rupture. However conventional surgery for aortic arch repair still carries significant risks of postoperative morbidity and mortality, especially in patients with old age. In an effort to correct the aortic pathology while minimizing the risks of complication, we performed a hybrid technique which comprises the off pump arch aortic stent grafting in an 86-old male patient with an aortic arch aneurysm.

Staged Surgical Treatment of Primary Aortoesophageal Fistula

  • Hwang, Sun Hyun;Cho, Jun Woo;Bae, Chi Hoon;Jang, Jae Seok
    • Journal of Chest Surgery
    • /
    • v.52 no.3
    • /
    • pp.182-185
    • /
    • 2019
  • Aortoesophageal fistula (AEF) is a rare and potentially fatal disease that causes massive gastrointestinal bleeding. Therefore, early diagnosis and treatment are essential to prevent mortality. Controlling the massive bleeding is the most important aspect of treating AEF. The traditional surgical treatment was emergent thoracotomy, but intraoperative or perioperative mortality was high. We report a case of a patient presenting with hematemesis who was successfully treated by a staged treatment, in which bridging thoracic endovascular aortic repair was followed by delayed surgical repair of the esophagus and aorta.

Non-Anastomotic Rupture of a Woven Dacron Graft in the Descending Thoracic Aorta Treated with Endovascular Stent Grafting

  • Lee, Youngok;Kim, Gun-Jik;Kim, Young Eun;Hong, Seong Wook;Lee, Jong Tae
    • Journal of Chest Surgery
    • /
    • v.49 no.6
    • /
    • pp.465-467
    • /
    • 2016
  • The intrinsic structural failure of a Dacron graft resulting from the loss of structural integrity of the graft fabric can cause late graft complications. Late non-anastomotic rupture has traditionally been treated surgically via open thoracotomy. We report a case of the successful use of thoracic endovascular repair to treat a Dacron graft rupture in the descending aorta. The rupture occurred 20 years after the graft had been placed. Two stent grafts were placed at the proximal portion of the surgical graft, covering almost its entire length.