• Title/Summary/Keyword: Thoracic endovascular aortic repair

Search Result 65, Processing Time 0.02 seconds

Surgical Repair of Retrograde Type A Aortic Dissection after Thoracic Endovascular Aortic Repair

  • Kim, Chang-Young;Chang, Woo-Ik;Kim, Yeon Soo;Ryoo, Ji Yoon
    • Journal of Chest Surgery
    • /
    • v.47 no.1
    • /
    • pp.39-42
    • /
    • 2014
  • It is expected that the stent graft will become an alternative method for treating aortic diseases or reducing the extent of surgery; therefore, thoracic endovascular aortic repair has widened its indications. However, it can have rare but serious complications such as paraplegia and retrograde type A aortic dissection. Here, we report a surgical repair of retrograde type A aortic dissection that was performed after thoracic endovascular aortic repair.

Traumatic Aortic Injury: Single-center Comparison of Open versus Endovascular Repair

  • Cho, Jun Woo;Kwon, Oh Choon;Lee, Sub;Jang, Jae Seok
    • Journal of Chest Surgery
    • /
    • v.45 no.6
    • /
    • pp.390-395
    • /
    • 2012
  • Background: Conventional open repair is a suboptimal therapy for blunt traumatic aortic injury (BTAI) due to the high postoperative mortality and morbidity rates. Recent advances in the thoracic endovascular repair technique may improve outcomes so that it becomes an attractive therapeutic option. Materials and Methods: From August 2003 to March 2012, 21 patients (mean age, 45.81 years) with BTAI were admitted to our institution. Of these, 18 cases (open repair in 11 patients and endovascular repair in 7 patients) were retrospectively reviewed and the early perioperative results of the two groups were compared. Results: Although not statistically significant, there was a trend toward the reduction of mortality in the endovascular repair group (18.2% vs. 0%). There were no cases of paraplegia or endoleak. Statistically significant reductions in heparin dosage, blood loss, and transfusion amounts during the operations and in procedure duration were observed. Conclusion: Compared with open repair, endovascular repair can be performed with favorable mortality and morbidity rates. However, relatively younger patients who have acute aortic arch angulation and a small aortic diameter may be a therapeutic challenge. Improvements in graft design, delivery sheaths, and graft durability are the cornerstone of successful endovascular repair.

Acute Thrombotic Occlusion of Left Internal Jugular Vein Compressed by Bypass Graft for Thoracic Endovascular Aortic Repair Debranching Procedure

  • Sim, Hyung Tae;Beom, Min Sun;Kim, Sung Ryong;Ryu, Sang Wan
    • Journal of Chest Surgery
    • /
    • v.47 no.6
    • /
    • pp.552-555
    • /
    • 2014
  • Thoracic endovascular aortic repair has become a widespread alternative treatment option for thoracic aortic aneurysm. The debranching of arch vessels may be required to provide an acceptable landing zone for an endovascular stent graft. We report a case where the bypass graft used in the thoracic endovascular aortic repair procedure compressed the left internal jugular vein, causing acute thrombotic occlusion.

Visceral Debranching Thoracic Endovascular Aneurysm Repair for Chronic Dissecting Thoracoabdominal Aortic Aneurysm

  • Cho, Kwang Jo;Park, Jong Yoon
    • Journal of Chest Surgery
    • /
    • v.47 no.6
    • /
    • pp.548-551
    • /
    • 2014
  • Type II chronic dissecting thoracoabdominal aortic aneurysms are a surgically challenging disease. The conventional thoracoabdominal aortic aneurysm repair technique using cardiopulmonary bypass is a high-risk procedure. However, a recently developed endovascular technique may be an alternative treatment for the disease, but faces the obstacle of lesional restriction. This new technique uses a hybrid strategy to overcome the limits of endovascular thoracoabdominal aortic aneurysm repair. Herein, we report on a successful outcome after performing the hybrid visceral debranching procedure.

Ruptured Abdominal Aortic Aneurysm after Endovascular Aortic Aneurysm Repair

  • Lee, Chung-Won;Chung, Sung-Woon;Kim, Jong-Won;Kim, Sang-Pil;Bae, Mi-Ju;Kim, Chang-Won
    • Journal of Chest Surgery
    • /
    • v.44 no.1
    • /
    • pp.68-71
    • /
    • 2011
  • In treating uncomplicated abdominal aortic aenurysm, endovascular aortic aneurysm repair (EVAR) has been employed as a good alternative to open repair with low perioperative morbidity and mortality. However, the aneurysm can enlarge or rupture even after EVAR as a result of device failure, endoleak, or graft migration. We experienced two cases of aneurismal rupture after EVAR, which were successfully treated by surgical extra-anatomic bypass.

Mid-Term Results of Thoracic Endovascular Aortic Repair for Complicated Acute Type B Aortic Dissection at a Single Center

  • Hong, Young Kwang;Chang, Won Ho;Goo, Dong Erk;Oh, Hong Chul;Park, Young Woo
    • Journal of Chest Surgery
    • /
    • v.54 no.3
    • /
    • pp.172-178
    • /
    • 2021
  • Background: Complicated acute type B aortic dissection is a life-threatening condition with high morbidity and mortality. The aim of this study was to report a single-center experience with endovascular stent-graft repair of acute type B dissection of the thoracic aorta and to evaluate the mid-term outcomes. Methods: We reviewed 18 patients treated for complicated acute type B aortic dissection by thoracic endovascular aortic repair (TEVAR) from September 2011 to July 2017. The indications for surgery included rupture, impending rupture, limb ischemia, visceral malperfusion, and paraplegia. The median follow-up was 34.50 months (range, 12-80 months). Results: The median interval from aortic dissection to TEVAR was 5.50 days (range, 0-32 days). There was no in-hospital mortality. All cases of malperfusion improved except for 1 patient. The morbidities included endoleak in 2 patients (11.1%), stroke in 3 patients (16.7%), pneumonia in 2 patients (11.1%), transient ischemia of the left arm in 1 patient (5.6%), and temporary visceral ischemia in 1 patient (5.6%). Postoperative computed tomography angiography at 1 year showed complete thrombosis of the false lumen in 15 patients (83.3%). Conclusion: TEVAR of complicated type B aortic dissection with a stent-graft was effective, with a low morbidity and mortality rate.

Aortic Arch Debranching and Antegrade Stent Graft Placement in an Expanding Distal Dissecting Aneurysm after Repair of an Acute Type I Aortic Dissection (Type I 급성 대동맥 박리 수술 후 진행하는 원위부 박리성 동맥류에 대한 대동맥궁 탈분지술과 전향적 대동맥궁 스텐트 그라프트의 설치)

  • Baek, Wan-Ki;Kim, Young-Sam;Lim, Hyun-Kyoung;Yoon, Yang-Han;Kim, Joung-Taek;Kim, Kwang-Ho
    • Journal of Chest Surgery
    • /
    • v.43 no.6
    • /
    • pp.729-733
    • /
    • 2010
  • Endovascular treatment of the aortic aneurysm with a stent graft is rapidly evolving. We describe here a case of hybrid TEVAR (thoracic endovascular aortic repair) in which the stent grafts were placed in the aortic arch after debranching of the arch vessels. The patient had undergone ascending aorta replacement for acute type I aortic dissection 2.5 years earlier. The aneurysmal change of the distal dissection progressed with time. A provisional bypass surgery from the ascending aorta to the innominate artery and left carotid artery was performed and then stent grafts were inserted via an antegrade route that covered the whole aortic arch and proximal descending thoracic aorta.

Endovascular Repair in Acute Complicated Type B Aortic Dissection: 3-Year Results from the Valiant US Investigational Device Exemption Study

  • Lim, Chang Young
    • Journal of Chest Surgery
    • /
    • v.50 no.3
    • /
    • pp.137-143
    • /
    • 2017
  • Acute complicated type B aortic dissection (TBAD) is a potentially catastrophic, life-threatening condition. If left untreated, there is a high risk of aortic rupture, irreversible organ or limb damage, or death. Several risk factors have been associated with acute complicated TBAD, including age and refractory hypertension. In the acute phase, even uncomplicated patients are more prone to develop complications if hypertension and pain are left medically untreated. Innovations in stent graft technologies have incrementally improved outcomes since their first use for this condition in 1999, though improvement is needed in mitigating periprocedural complications, adverse events, and mortality. In the past decade, endovascular repair has become the preferred treatment because of its superior outcomes to open repair and medical therapy. The Valiant Captivia Thoracic Stent Graft System is a third-generation endovascular stent graft with advancements in minimally invasive delivery, conformability to the anatomy, and the minimization of adverse sequelae. Herein, this stent graft is briefly reviewed and its 3-year outcomes are presented. Freedom from all-cause and dissection-related mortality was 79.1% and 90.0%, respectiv ely. The Valiant Captiv ia Stent Graft represents a safe, effective intervention for acute complicated TBAD. Continued surveillance is needed to verify its longer-term durability.

Thoracic Endovascular Repair for Complicated Type B Acute Aortic Dissection with Distal Malperfusion

  • Choo, Suk-Jung;Jung, Sung-Ho;Kim, Ji-Eon;Lim, Ju-Yong;Ju, Min-Ho
    • Journal of Chest Surgery
    • /
    • v.44 no.6
    • /
    • pp.427-431
    • /
    • 2011
  • Successful thoracic endovascular repair for complicated Stanford type B acute aortic dissection in two patients is herein reported. The true lumen flow was immediately restored following stent graft deployment in the descending thoracic aorta with subsequent resolution of the distal malperfusion syndrome. One patient is doing well more than 15 months after surgery and another patient who was treated more recently is also doing well 7 months postoperatively.

Aortic Valve Replacement Using Balloon Catheter for Thoracic Endovascular Aortic Repair to Patient with Calcified Aorta

  • Kim, In Sook;Byun, Joung Hun;Yoo, Byung Ha;Kim, Han Yong;Hwang, Sang Won;Song, Yun Gyu
    • Journal of Chest Surgery
    • /
    • v.46 no.3
    • /
    • pp.212-215
    • /
    • 2013
  • A 79-year-old man was admitted to Samsung Changwon Hospital due to chest pain and dyspnea. The ejection fraction was 31% and mean pressure gradient between the left ventricle and aorta was 69.4 mmHg on echocardiography. Chest computed tomography showed severe calcification of the ascending aorta. Aortic valve replacement was successfully performed using a thoracic endovascular aortic repair balloon catheter without classic aortic cross clamping. The patient was discharged on the eleventh postoperative day.