• Title/Summary/Keyword: Thomson

Search Result 213, Processing Time 0.025 seconds

Representation of fundamental solution and vibration of waves in photothermoelastic under MGTE model

  • Rajneesh Kumar;Nidhi Sharma;Supriya Chopra;Anil K. Vashishth
    • Ocean Systems Engineering
    • /
    • v.13 no.2
    • /
    • pp.123-146
    • /
    • 2023
  • In this paper, Moore-Gibson-Thompson theory of thermoelasticity is considered to investigate the fundamental solution and vibration of plane wave in an isotropic photothermoelastic solid. The governing equations are made dimensionless for further investigation. The dimensionless equations are expressed in terms of elementary functions by assuming time harmonic variation of the field variables (displacement, temperature distribution and carrier density distribution). Fundamental solutions are constructed for the system of equations for steady oscillation. Also some preliminary properties of the solution are explored. In the second part, the vibration of plane waves are examined by expressing the governing equation for two dimensional case. It is found that for the non-trivial solution of the equation yield that there exist three longitudinal waves which advance with the distinct speed, and one transverse wave which is free from thermal and carrier density response. The impact of various models (i)Moore-Gibson-Thomson thermoelastic (MGTE)(2019), (ii) Lord and Shulman's (LS)(1967) , (iii) Green and Naghdi type-II(GN-II)(1993) and (iv) Green and Naghdi type-III(GN-III)(1992) on the attributes of waves i.e., phase velocity, attenuation coefficient, specific loss and penetration depth are elaborated by plotting various figures of physical quantities. Various particular cases of interest are also deduced from the present investigations. The results obtained can be used to delineate various semiconductor elements during the coupled thermal, plasma and elastic wave and also find the application in the material and engineering sciences.

Number of Scatterings in Random Walks

  • Kwang-Il Seon;Hyung-Joe Kwon;Hee-Gyeong Kim;Hyeon Jeong Youn
    • Journal of The Korean Astronomical Society
    • /
    • v.56 no.2
    • /
    • pp.287-292
    • /
    • 2023
  • This paper investigates the number of scatterings a photon undergoes in random walks before escaping from a medium. The number of scatterings in random walk processes is commonly approximated as τ + τ2 in the literature, where τ is the optical thickness measured from the center of the medium. However, it is found that this formula is not accurate. In this study, analytical solutions in sphere and slab geometries are derived for both optically thin and optically thick limits, assuming isotropic scattering. These solutions are verified using Monte Carlo simulations. In the optically thick limit, the number of scatterings is found to be 0.5 τ2 and 1.5 τ2 in a sphere and slab, respectively. In the optically thin limit, the number of scatterings is ≈ τ in a sphere and ≈ τ (1 - γ - ln τ + τ) in a slab, where γ ≃ 0.57722 is the Euler-Mascheroni constant. Additionally, we present approximate formulas that reasonably reproduce the simulation results well in intermediate optical depths. These results are applicable to scattering processes that exhibit forward and backward symmetry, including both isotropic and Thomson scattering.

An Experimental Study of The J-T Cryocooler with Mixed Refrigerant (혼합 냉매를 이용한 극저온 J-T 냉동기 관한 실험적 연구)

  • 이경수;정상권
    • Progress in Superconductivity and Cryogenics
    • /
    • v.3 no.1
    • /
    • pp.64-68
    • /
    • 2001
  • An experimental study on the Joule-Thomson cryocooler with the mixed refrigerant (MR) is described in this paper, J-T refrigeration experiment was performed with a single stage regular air-conditioning compressor The mixed refrigerant in the experiment was composed of 75% mol fraction of $N_2$. 30% moi fraction of CH$_4$. 30% moi fraction of $C_2$H$_{6}$. 10% mot fraction of $C_3$H$_{8}$ and 15% mot fraction of iso-C$_4$H$_{10}$. Oil mist in the MR stream could be eliminated completely by the glass microfiber filter. Since a single stage compressor that had been designed thor R22 is not appropriate for high Pressure ratio of the mixed refrigerant especially during the transient period. two modifications were incorporated to regular J-T refrigeration cycle. First. a Portion of the MR was by-passed at the inlet of the heat exchanger and transferred directly to 7he suction of the compressor in the modified system. Second, a buffer volume was Prepared to change the mass flow rate of refrigerant. The pressure ratio in J-T expansion device was relieved at the beginning of the operation due to the by-Pass scheme. but it gradually decreased during the transient Process as some of the MR component condensed at low temperature. The buffer volume at the suction side was used to increase the MR gas density in the system after the transient cool-down period. Form the experiment with the modified system, the refrigerator could reach the lowest temperature of -152$^{\circ}C$ without cooling load. and about -15$0^{\circ}C$ with 5 W of cooling load . . . .

  • PDF

Measurement of electron density of atmospheric pressure Ar plasma jet by using Michelson interferometer

  • Lim, Jun-Sup;Hong, Young June;Choi, Eun Ha
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.195.1-195.1
    • /
    • 2016
  • Currently, as Plasma application is expanded to the industrial and medical industrial, low temperature plasma applications became important. Especially in medical and biology, many researchers have studied about generated radical species in atmospheric pressure low temperature plasma directly adapted to human body. Therefore, so measurement their plasma parameter is very important work and is widely studied all around world. One of the plasma parameters is electron density and it is closely relative to radical production through the plasma source. some kinds of method to measuring the electron density are Thomson scattering spectroscopy and Millimeter-wave transmission measurement. But most methods have very expensive cost and complex configuration to composed of experiment system. We selected Michelson interferometer system which is very cheap and simple to setting up, so we tried to measuring electron density by laser interferometer with laser beam chopping module for measurement of temporal phase difference in plasma jet. To measuring electron density at atmospheric pressure Ar plasma jet, we obtained the temporal phase shift signal of interferometer. Phase difference of interferometer can occur because of change by refractive index of electron density in plasma jet. The electron density was able to estimate with this phase difference values by using physical formula about refractive index change of external electromagnetic wave in plasma. Our guiding laser used Helium-Neon laser of the centered wavelength of 632 nm. We installed chopper module which can make a 4kHz pulse laser signal at the laser front side. In this experiment, we obtained more exact synchronized phase difference between with and without plasma jet than reported data at last year. Especially, we found the phase difference between time range of discharge current. Electron density is changed from Townsend discharge's electron bombardment, so we observed the phase difference phenomenon and calculated the temporal electron density by using phase shift. In our result, we suggest that the electron density have approximately range between 1014~ 1015 cm-3 in atmospheric pressure Ar plasma jet.

  • PDF

The Role of Brain Somatostatin in the Central Regulation of Feed, Water and Salt Intake in Sheep

  • Sunagawa, Katsunori;Weisinger, Richard S.;McKinley, Michael J.;Purcell, Brett S.;Thomson, Craig;Burns, Peta L.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.14 no.7
    • /
    • pp.929-934
    • /
    • 2001
  • The physiological role of brain somatostatin in the central regulation of feed intake in sheep was investigated through a continuous intracerebroventricular (ICV) infusion of somatostastin 1-28 (SRIF) at a small dose of $5{\mu}g/0.2ml/hr$ for 98.5 hours from day 1 to day 5. Sheep (n=5) were fed for 2 hours once a day, and water and 0.5 M NaCI solution were given ad libitum. Feed, water and salt intake were measured during ICV infusion of artificial cerebrospinal fluid (CSF) and SRIF. The feed intake during SRIF infusion on days 2 to 5 increased significantly compared to that during CSF infusion. Water intake, when compared to that during CSF infusion, only increased significantly on day 4. NaCI intake during SRIF infusion was not different from that during CSF infusion. Mean arterial blood pressure (MAP) and heart rate during SRIF infusion were not different from those during CSF infusion. The plasma concentrations of Na, K, Cl, osmolality and total protein during SRIF infusion were also not different from those values during CSF infusion.There are two possible mechanisms, that is, the suppression of brain SRIF on feed suppressing hormones and the direct actions on brain mechanisms controlling feed intake, explaining how SRIF works in the brain to bring about increases in feed intake in sheep fed on hay. The results indicate that brain SRIF increases feed intake in sheep fed on hay.

A Study on Performance Evaluation of CEA kits (CEA 키트들 간의 성능 평가에 대한 고찰)

  • Ha, Dong hyuk;Sin, Hee Jung;You, Tae min;Noh, Kyoung Woon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.22 no.1
    • /
    • pp.76-79
    • /
    • 2018
  • Purpose Carcinoembryonic antigen (CEA) is cell-surface 180-200 kDa glycoprotein that is overexpressed in breast, stomach pancreas, lung, and colorectal cancers. CEA was first described in 1965 by Gold and Freedman and then serum CEA of colorectal cancer patients was first measured in 1969 by radioimmunoassay by Thomson. CEA is currently most widely used tumor marker in the clinic for management of colorectal cancer. Various CEA test kits have been developed and commercialized. CEA kits from different manufacturers might have different test results because of different reagents and protocol. The purpose of this study was to compare results of four commercial available CEA kits. Materials and Methods This study was designed to evaluate four commercially available CEA kits using serum samples acquired from 120 patients who visited our clinic. Test results were compared and analyzed according to the respective test methods. High concentration samples were diluted with saline and diluted solution. Results All of the four kits showed a significant correlation within the reference value. However, three of the four kits used for the dilution test using high concentration samples showed the hook effect. Conclusion Results of the present study showed that It is important to establish the standardized dilution standards for the high-concentration specimens to manage the error of the test result by the hook effect.

High Intensity Laser for Laser Acupuncture Application (침구치료에 사용되는 고출력 레이저에 대한 고찰)

  • Yang, Chang-Sop;Sun, Seung-Ho;Jang, In-Soo
    • Korean Journal of Acupuncture
    • /
    • v.28 no.3
    • /
    • pp.1-12
    • /
    • 2011
  • Objectives : The purpose of this study is to review laser acupuncture studies to find possibility for applying high intensity laser to acupuncture and moxibustion treatment. Methods : Searching papers was performed using search engines of five electronic databases, including Pubmed, Thomson ISI, EMBASE, Sciencedirect, and EBSCO, from inception to May 2011 without language limitation. Inclusion criteria were clinical studies with human, randomized controlled trials (RCTs), case-control studies, and case reports. Selecting papers was performed with titles and abstracts in first step, scrutinize full text in second step, and then the extrated data was analyzed by two authors independently. The methodological quality for RCTs was evaluated using Jadad's scale. Results : Total 8 papers, (3 RCTs, 5 controlld studies, and 1 case reports), were finally selected. The study dealt with surgical laser, argon and $CO_2$ laser was one for each, with GaAs laser was two, and with new semiconductor laser, GaN, were four. The output range was from 110 mW to 15 W. The study diseases were alcohol addiction, knee osteoarthritis, bronchopneumonia and asthma for children, and circulation. All studies reported positive effect. The methodological quality in all RCTs was low because of below 3 points and all studies had few subject numbers. Conclusions : We suggest that high intensity laser can be applied to acupuncture and moxibustion. Further rigorous and well-designed study will be needed for various disease. The oriental medical society needs to take active measures to study and clinical application of acupuncture and moxibustion treatment with high intensity laser.

Current status of simulation training in plastic surgery residency programs: A review

  • Thomson, Jennifer E.;Poudrier, Grace;Stranix, John T.;Motosko, Catherine C.;Hazen, Alexes
    • Archives of Plastic Surgery
    • /
    • v.45 no.5
    • /
    • pp.395-402
    • /
    • 2018
  • Increased emphasis on competency-based learning modules and widespread departure from traditional models of Halstedian apprenticeship have made surgical simulation an increasingly appealing component of medical education. Surgical simulators are available in numerous modalities, including virtual, synthetic, animal, and non-living models. The ideal surgical simulator would facilitate the acquisition and refinement of surgical skills prior to clinical application, by mimicking the size, color, texture, recoil, and environment of the operating room. Simulation training has proven helpful for advancing specific surgical skills and techniques, aiding in early and late resident learning curves. In this review, the current applications and potential benefits of incorporating simulation-based surgical training into residency curriculum are explored in depth, specifically in the context of plastic surgery. Despite the prevalence of simulation-based training models, there is a paucity of research on integration into resident programs. Current curriculums emphasize the ability to identify anatomical landmarks and procedural steps through virtual simulation. Although transfer of these skills to the operating room is promising, careful attention must be paid to mastery versus memorization. In the authors' opinions, curriculums should involve step-wise employment of diverse models in different stages of training to assess milestones. To date, the simulation of tactile experience that is reminiscent of real-time clinical scenarios remains challenging, and a sophisticated model has yet to be established.

The Role of Corticotropin-Releasing Factor and Urocortin in Brain Mechanisms Controlling Feed Intake of Sheep

  • Sunagawa, K.;Weisiger, R.S.;McKinley, M.J.;Purcell, B.S.;Thomson, C.;Burns, P.L.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.13 no.11
    • /
    • pp.1529-1535
    • /
    • 2000
  • The aim of the present study was to determine whether brain corticotropin-releasing factor (CRF) and a new peptide, urocortin (UCN) have a direct action in brain mechanisms controlling feed, water and salt intake in sheep. We gave a continuous intracerebroventricular (ICV) infusion of the peptide at a small dose of $5{\mu}g/0.2ml/hr$ for 98.5 hrs from day 1 to day 5 in sheep not exposed to stress. Feed and water intake during ICV infusion of CRF or UCN decreased significantly compared to those during artificial cerebrospinal fluid (CSF) infusion. NaCl intake during infusion of CRF or UCN was the same as that during CSF infusion. Mean carotid arterial blood pressure (MAP) and heart rate during ICV infusion of CRF or UCN were not significantly different from that during CSF infusion. On the other hand, the plasma glucose concentration during ICV infusion of CRF or UCN tended to be higher than that during CSF infusion. These observations indicate that decreased feed intake induced by CRF and UCN infusion is not mediated by the activation of both the pituitary-adrenal axis and the sympathetic nervous system. The results suggested that brain CRF and UCN act directly in brain mechanisms controlling ingestive behavior to decrease feed and water intake, but do not alter salt intake in sheep.

Damage studies on irradiated tungsten by helium ions in a plasma focus device

  • Seyyedhabashy, Mir mohammadreza;Tafreshi, Mohammad Amirhamzeh;bidabadi, Babak Shirani;Shafiei, Sepideh;Nasiri, Ali
    • Nuclear Engineering and Technology
    • /
    • v.52 no.4
    • /
    • pp.827-834
    • /
    • 2020
  • Damage of tungsten due to helium ions of a PF device was studied. The tungsten was analyzed by SEM and AFM after irradiation. SEM revealed fine bubbles of helium atoms with diameters of a few nanometers, which join and form larger bubbles and blisters on the surface of tungsten. This observation confirmed the results of molecular dynamics simulation. SEM analysis after etching of the irradiated surface indicated cavities with depth range of 35-85 nm. The average fluence of helium ion of the PF device was calculated about 5.2 × 1015 cm-2 per shot, using Lee code. Energy spectrum of helium ions was estimated using a Thomson parabola spectrometer as a function of dN/dE ∝ E-2.8 in the energy range of 10-200 keV. The characteristics of helium ion beam was imported to SRIM code. SRIM revealed that the maximum DPA and maximum helium concentration occur in the depth range of 20-50 nm. SRIM also showed that at depth of 30 nm, all of the tungsten atoms are displaced after 20 shots, while at depth of higher than 85 nm the destruction is insignificant. There is a close match between SRIM results and the measured depths of cavities in SEM images of tungsten after etching.