• Title/Summary/Keyword: Thinned

Search Result 343, Processing Time 0.025 seconds

Evaluation of the Burst Pressure for Rectangular Wall-thinning of CANDU Feeder Pipe (사각 감육을 고려한 중수로 공급자관 파열압력 평가)

  • Kwang Soo Kim;Min Kyu Kim;Doo Ho Cho;Jae Joon Jeong
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.17 no.1
    • /
    • pp.28-35
    • /
    • 2021
  • The flow accelerated corrosion (FAC) is one of significant aging and degradation mechanism and can affect structural integrity of CANDU feeder pipes. Pipe burst can occur under normal operation pressure (min. 10 MPa) if wall-thinning of the feeder pipe due to FAC is accumulated. Previous studies considered simple shapes of feeder pipe with local wall-thinning in order to conservatively assess structural integrity of wall-thinned feeder pipe. In this paper, a new FE model is developed, having an actual shape of the feeder pipe (double bent) as well as the actual wall-thinning shape and location based on the in-service inspection result. Then, the burst pressure assessment of the wall-thinned feeder pipe is performed using lower bound limit load analysis considering elastic-perfectly plastic material. In addition, an improved formulation to predict the burst pressure of the wall-thinned feeder pipe is presented and the safety margin is compared with an existing assessment method.

Fracture Behavior Evaluation of Wall Thinned pipes by Finite Element Analysis (감육배관의 요한요소해석에 의한 파괴거동 평가)

  • AHN SEOK-HWAN;NAM KI-Woo;KIM JIN-WOOK;LEE SOO-SIG;YOON JA-MUN
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.320-325
    • /
    • 2004
  • Fracture behaviors and strength of pipes with local wall thinning are very important Jar the integrity of energy plants. In pipes of energy plants, sometimes, the local wall thinning may result from severe erosion-corrosion damage. Recently, the effects of local wall thinning on strength and fracture behaviors of piping system have been well studied. In this paper, the elasto-plastic analysis is performed by FE code ANSIS. We evaluated the failure mode, fracture strength and fracture behavior from FE analysis.

  • PDF

Design of an Optimal Planar Array Structure with Uniform Spacing for Side-Lobe Reduction

  • Bae, Ji-Hoon;Seong, Nak-Seon;Pyo, Cheol-Sig;Park, Jae-Ick;Chae, Jong-Suk
    • Journal of electromagnetic engineering and science
    • /
    • v.3 no.1
    • /
    • pp.17-21
    • /
    • 2003
  • In this paper, we design an optimal planar array geometry for maximum side-lobe reduction. The concept of thinned array is applied to obtain an optimal two dimensional(2-D) planar array structure. First, a 2-D rectangular array with uniform spacing is used as an initial planar array structure. Next, we modify the initial planar array geometry with the aid of thinned array theory in order to reduce the maximum side-lobe level. This is implemented by a genetic algorithm under some constraint, minimizing the maximum side-lobe level of the 2-D planar array. It is shown that the optimized planar array structure can achieve low side-lobe level without optimizing the excitations of the array antennas.

Finite Element Analysis for Wall Thinned Steam Generator Tubes (감육된 증기발생기 전열관의 유한요소 해석)

  • Seong, K.Y.;Ahn, S.H.;Nam, K.W.
    • Journal of Power System Engineering
    • /
    • v.10 no.3
    • /
    • pp.38-44
    • /
    • 2006
  • Failure assessment of steam generator tube are very important for the integrity of energy plants. In pipes of energy plants, sometimes, the local wall thinning may result from severe erosion-corrosion damage. Recently, the effects of local wall thinning on fracture strength and fracture behavior of piping system have been well studied. In this paper, the elasto-plastic analysis is performed by FE code ANSIS on steam generator tube with wall thinning. We evaluated the failure mode, fracture strength and fracture behavior from FE analysis. It was possible to predict the crack initiation point by estimating true fracture ductility under multi-axial stress conditions at the center of the thinned area.

  • PDF

A Weighted Least Square Method for Optimization of Thinned Sensor Arrays (희소어레이의 최적화를 위한 계수 최소 자승 방법)

  • 장병건
    • The Journal of the Acoustical Society of Korea
    • /
    • v.18 no.4
    • /
    • pp.78-83
    • /
    • 1999
  • This paper concerns a least square method for pattern optimization of a thinned sensor array in which the squared error between a desired pattern and a synthesized one is minimized. A weighting function is applied in the function with respect to the array visual range for a symmetric and asymmetric configuration for sensor spacing. An exponential weighting function is proposed to control the sidelobes efficiently around the mainbeam and to generate a uniform sidelobe. The resulting pattern may be employed to eliminate incoming interferences distributed uniformly around the array visual range.

  • PDF

Soil nitrogen availability in a thinned Larix leptolepis plantation using ion exchange resin bags (이온교환수지봉지를 이용한 일본잎갈나무 간벌지의 질소 유효도 측정)

  • Son, Yo-Whan;Kim, Hyun-Seop
    • Korean Journal of Environmental Agriculture
    • /
    • v.19 no.2
    • /
    • pp.188-190
    • /
    • 2000
  • We explored changes in soil nitrogen (N) availability in a thinned (control, light, moderate, and heavy thinning) Larix leptolepis plantation determined by using ion exchange resin bags. Nitrogen availability varied among measurement periods, however, total available N (ammonium plus nitrate) concentrations did not change significantly in the 1 year since thinning. We found higher N availability in summer and fall than in winter.

  • PDF

Engineering Estimation of Limit Load Solution for Wall-Thinned Pipes Considering Material Properties (재료물성을 고려한 감육배관의 공학적 한계하중해 제시)

  • Choi, Jae-Boong;Kim, Jin-Su;Goo, Bon-Geol;Kim, Young-Jin;Choi, Young-Hwan
    • Proceedings of the KSME Conference
    • /
    • 2001.06a
    • /
    • pp.351-356
    • /
    • 2001
  • A potential loss of structural integrity due to aging of nuclear piping may have a significant effect on the safety of nuclear power plants. In particular, failures due to the erosion and corrosion defects are a major concern. As a result, there is a need to assess the remaining strength of pipe with erosion/corrosion defects. In this paper, a limit load solution for the eroded and corroded SA106 Grade B pipes subjected by internal pressure is developed. based in 3-D finite element analyses, considering a wide range of the shape of pipeline, flaw depth and axial flaw length parametrically.

  • PDF

Manufacturing Characteristics of Woodceramics from Thinned Small Logs (II) - Dimensional Change, Weight Change and Compressive Strength -

  • Oh, Seung-Won;Hirose, Takashi;Okabe, Toshihiro
    • Journal of the Korean Wood Science and Technology
    • /
    • v.28 no.4
    • /
    • pp.56-60
    • /
    • 2000
  • A new porous carbon material "woodceramics" was developed by carbonizing wood or woody materials impregnated with thermosetting resin. Steamed board and non-steamed board were made from thinned small log of Aomori Hiba (Thujopsis dolabrata S. et. Z. var. hondae M.). They were impregnated with phenol resin and sintered in a vacuum furnace at $650^{\circ}C$. In this paper, the manufacturing method of woodceramics and changes of dimension, weight and compressive strength were investigated. The changes of dimension, weight and compressive strength depend on the types of board and density.

  • PDF

Electrical Properties of Woodceramics Made from Thinned Logs of Cryptomeria japonica D.DON (삼나무 간벌재로 제조된 우드세라믹의 전기적성질)

  • ;Toshihiro Okabe;Takashi Hirose
    • Journal of the Korea Furniture Society
    • /
    • v.11 no.1
    • /
    • pp.31-36
    • /
    • 2000
  • Woodceramics are new porous carbon materials obtained by carbonization of wood or woody materials impregnated with thermosetting resin in a vacuum furnace. This study examined the electrical properties of woodceramics made from thinned logs of Cryptomeria japonica as a use for electric articles. The summarized results were as follows: 1. The volume resistivity of woodceramics decreased with increasing density of woodceramics made from 3 type board. And the volume resistivity of woodceramics made from non- steamed board was somewhat higher than steamed board. 2. The consumption of electric power of woodceramics decreased with increasing density of woodceramics and resin contents made from 3 type board. And the consumption of electric power of woodceramics made from non-steamed board was somewhat higher than steamed board. 3. When the woodceramics were coated by silicon, the consumption of electric power increased about 7%.

  • PDF

Effect of Bend Angle on the Collapse Behavior of Locally Wall Thinned Pipe Bends (감육 곡관의 붕괴거동에 미치는 곡관 굽힘각의 영향)

  • Na Man-Gyun;Kim Jin-Weon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.30 no.10 s.253
    • /
    • pp.1269-1275
    • /
    • 2006
  • The purpose of this study is to investigate the effect of bend angle on the collapse behavior of locally wall thinned pipe bends. For this purpose, the present study performed three-dimensional finite element analysis on the 30-, 60-, and 90-degree pipe bends with local wall thinning at the center of intrados, extrados, and crown, and evaluated the collapse moment for different thinning dimensions under closing- and opening-mode bending with a constant internal pressure. The results showed that, for intrados and extrados wall thinning, the reduction in the collapse moment due to local wall thinning became significant with decreasing bend angle of pipe bends. This effect of bend angle was enhanced with increasing thinning dimensions, and it was clearer fur opening-mode bending than for closing-mode bending. For crown wall thinning, however, the effect of bend angle was unclear and was less sensitive to the change of wall thinning shapes.