• Title/Summary/Keyword: Thickness change

Search Result 2,328, Processing Time 0.037 seconds

Effect of initial placement level and wall thickness on maintenance of the marginal bone level in implants with a conical implant-abutment interface: a 5-year retrospective study

  • Yoo, Jaehyun;Moon, Ik-Sang;Yun, Jeong-Ho;Chung, Chooryung;Huh, Jong-Ki;Lee, Dong-Won
    • Journal of Periodontal and Implant Science
    • /
    • v.49 no.3
    • /
    • pp.185-192
    • /
    • 2019
  • Purpose: Implant wall thickness and the height of the implant-abutment interface are known as factors that affect the distribution of stress on the marginal bone around the implant. The goal of this study was to evaluate the long-term effects of supracrestal implant placement and implant wall thickness on maintenance of the marginal bone level. Methods: In this retrospective study, 101 patients with a single implant were divided into the following 4 groups according to the thickness of the implant wall and the initial implant placement level immediately after surgery: 0.75 mm wall thickness, epicrestal position; 0.95 mm wall thickness, epicrestal position; 0.75 mm wall thickness, supracrestal position; 0.95 mm wall thickness, supracrestal position. The marginal bone level change was assessed 1 day after implant placement, immediately after functional loading, and 1 to 5 years after prosthesis delivery. To compare the marginal bone level change, repeated-measures analysis of variance was used to evaluate the statistical significance of differences within groups and between groups over time. Pearson correlation coefficients were also calculated to analyze the correlation between implant placement level and bone loss. Results: Statistically significant differences in bone loss among the 4 groups (P<0.01) and within each group over time (P<0.01) were observed. There was no significant difference between the groups with a wall thickness of 0.75 mm and 0.95 mm. In a multiple comparison, the groups with a supracrestal placement level showed greater bone loss than the epicrestal placement groups. In addition, a significant correlation between implant placement level and marginal bone loss was observed. Conclusions: The degree of bone resorption was significantly higher for implants with a supracrestal placement compared to those with an epicrestal placement.

Numerical Investigation of Thermo-Fluid Flow for Improvement of Micro-Dilution Chamber on Particulate Deposition (수치적 열유동 해석을 통한 마이크로 희석챔버의 개선)

  • Kim, Sung-Hoon;Lee, Dong-Ryul
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.33 no.5
    • /
    • pp.637-645
    • /
    • 2009
  • The main purpose of this study lies on the improvement of micro dilution tunnel based on the typical porous tube type chamber. The characteristics of flow and temperature fields for steady state has been obtained by numerical analysis using FLUENT. Three different geometrical variations of the porous tube; a) increase of thickness at center, b) step increase of thickness at center and downstream, c) tapered increase of thickness, have been proposed. Accordingly results are obtained and compared in terms of penetration velocity and velocity ratio to therrmophoretic velocity for improvement against particulate deposition inside the tube. The penetration velocity and velocity ratio distributions in the upstream portion and portion of impinging of dilution air are apparently shown to be improved for the case of the step and tapered change of porous tube. The tapered change of tube thickness addition are shown to be the most effective among three geometrical changes. In addition, the considerable improvement against deposition are shown that its thickness should be at least 2mm.

Effects of Bridging Exercise using Vibration Stimulation and ADIMs on the Lengthening and Thickness of Transversus Abdominis in Healthy Adults

  • Kong, Kwan-Woo
    • The Journal of Korean Physical Therapy
    • /
    • v.28 no.6
    • /
    • pp.393-397
    • /
    • 2016
  • Purpose: This study was conducted in an effort to determine the effects of various abdominal drawing-in maneuver (ADIM) on the thickness and length of the transversus abdominis (TrA) when using lumbar stabilization exercises on healthy adults. Methods: 72 healthy adults were divided into four groups of 18 subjects each, to which different ADIM methods were applied. 1) a simple ADIM exercise, 2) an ADIM with pressure bio-feedback units, 3) an ADIM exercise with sling, and 4) an ADIM exercise with sling and vibration. Changes in the thickness and sliding length of TrA were measured when ADIM was conducted in the supine position prior to exercise and again when beginning the exercises. Following exercise, changes in the thickness and sliding length of TrA were measured using the same methods. Differences in group measurements prior to and following exercise were compared using a one-way analysis of variance. A paired t-test was applied to compare the before and after differences within each group. Results: Differences in TrA thickness change revealed that the ADIM exercise with sling and vibration group showed a significant difference in measurements taken prior to and following exercise. Differences in TrA length change revealed that the ADIM exercise with sling and vibration group showed a significant difference in measurements taken prior to and following exercise. Conclusion: ADIM exercise with vibration stimulation conducted in the bridge posture while in a prone position using a sling can be recommended as an effective exercise to improve the function of lumbar TrA.

Analysis of the change in appearance according to the hardening method of leather (가죽의 경화방법에 따른 외형변화 분석)

  • Youshin, Park
    • Journal of Fashion Business
    • /
    • v.26 no.5
    • /
    • pp.122-134
    • /
    • 2022
  • This study is conducted on hardening leather with improved firmness and stability of shape, based on research on types and thickness of leather. The purpose of this study is to test the physical properties of the leather for molding to prepare the foundation for leather molding based on the test results using four methods by thickness of Vegetable and Split. The tests were conducted using a total of five leather types, including three types of vegetable leathers and two types of split, by thickness. Based on the testing method for leathers in KS M 6882, the tests were performed at 27℃ with relative humidity of 65±20%. The samples were prepared with cowhide, size 9cm× 2cm. The measurement parameters are length and width. thickness, volume, mass, density. Regarding the hardening treatment method, changes in appearance and major physical characteristics of leather were reviewed by soaking in hot water, dry heating, hammering, waxing, and olive oil coating. The study results are as follows. In planar works, it is judged that hardening work using a hammer is more suitable for stiffness or density in order to prevent easy breakage with adult muscle density, rather than boiling water or baking. In conclusion, there is no curling, soot, or breaking phenomenon, and the densest curing method is 50℃ for 20 sec of V2 and 75℃ for 60 sec of V2 in boiling water. The combination of paraffin treatment improve waterproof and quality.

Effect of Vibration Exercise Application on the Trunk Muscle Thickness in Children with Spastic Cerebral Palsy

  • Mun, Dal-Ju;Park, Jae-Chul;Oh, Hyun-Ju
    • The Journal of Korean Physical Therapy
    • /
    • v.34 no.2
    • /
    • pp.68-72
    • /
    • 2022
  • Purpose: This study examined the effect of vibration exercise on the thickness of the oblique extrinsic, oblique abdominal, and biceps muscles, which are trunk muscles, targeting children with spastic cerebral palsy. Methods: The participants in this study were 20 children (8 male and 12 female) with cerebral palsy aged 5-10 years. They were classified into two groups using a randomized allocation method, and the trunk muscle thickness was measured using an ultrasound-imaging device before and six weeks after the experiment. A paired t-test was used for the within-group changes, and an independent t-test was used for the inter-group changes. The significance level was set to α=0.05. Results: There was a significant increase in the inter-group change in the experimental group and control group in the intra-group change in the external oblique muscle and internal oblique muscle. After six weeks, there was a significant increase in the experimental group compared to the control group. Conclusion: Vibration exercise had a positive effect on the trunk muscle thickness of children with cerebral palsy. Vibration exercise produced a significant difference in the changes in the trunk muscle thickness in children with cerebral palsy compared to no vibration exercise. These results may provide basic data for future research and as a training method for strengthening the trunk muscles in clinical trials.

Theoretical Sensitivity of Warp to Varying Layer Thickness in 5-layer Plywood

  • Via, Brian K.;Wu, Q.;Hartley, Ian D.;Shupe, Todd F.;Lee, Sangyeob;Lee, Byung G.
    • Journal of the Korean Wood Science and Technology
    • /
    • v.33 no.2 s.130
    • /
    • pp.24-28
    • /
    • 2005
  • Monte Carlo simulation was performed on theoretical models of plywood warp for southern yellow pine plywood originating from the United States. The objective of the investigation was to determine which plywood layers was more warp sensitive to veneers that were manufactured to an undesired thickness. This study found that for a balanced panel (a panel of equal target thickness for each of five layers) manufactured veneers of undesired thickness would experience minimal warp. The veneers of undesired thickness placed in the center of the plywood panel also provided a minimum change of plywood warp properties. The panel warp was very sensitive to surface veneers constructed with undesired thickness. Conversely, this study confirms that monitoring of veneer thickness and proper allocations within the plywood lay-up were critical.

In-situ monitoring technique for deposition process of CdS buffer layer for CIGS thin film solar cells (CIGS 박막 태양전지용 CdS 버퍼층 제조 공정의 in-situ 모니터링 기술)

  • Kown, Young-Jun;Ahn, Se-Jin;Yoon, Jae-Ho;Yoon, Kyung-Hoon
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.05a
    • /
    • pp.434-435
    • /
    • 2008
  • An in-situ monitoring technique for deposition process of CdS buffer layer was developed in this work. A quartz crystal microbalance (QCM) was used to measure the frequency change during the CdS deposition process and the relation ship between frequency change and film thickness and optical transmittance was investigated. The film thickness shows a linear relationship with frequency change, demonstrating that frequency change measured by QCM can be used a in-situ monitoring tool for CdS deposition process.

  • PDF

The Effect of Mechanical Horseback-Riding Training according to Velocity on Trunk Muscles Thickness in Healthy Adult

  • Lim, Jae-Heon;Cho, Woon-Su;Park, Jang-Sung
    • The Journal of Korean Physical Therapy
    • /
    • v.27 no.5
    • /
    • pp.281-286
    • /
    • 2015
  • Purpose: The study was to determine whether mechanical horseback-riding training according to velocity may improve trunk muscles thickness in healthy adults. Methods: Twenty healthy adults participated in this study. The subjects were divided into 2 groups as follows: 10 subjects in high velocity mechanical horseback-riding training (MHRT) and 10 subjects in low velocity MHRT. Subjects in all groups performed a total of 18 sessions 3 times a day for 20 minutes and this experiment lasted for 6 weeks. Mann-Whitney and Wilcoxon Signed Rank test were used in analysis the results of trunk muscle thickness. Ultrasonography was performed to evaluate for thickness of rectus abdominis (RA), external oblique (EO), internal oblique (IO), transverse abdominis (TrA), erector spine (ES), and multifidus (MF) in trunk muscles. Results: Results on the changes of EO, IO, and ES of high velocity MHRT showed a significant increase after 6 weeks (p<0.05). Regarding the changes of EO, IO, ES, TrA, and MF of low velocity MHRT, a significant increase was observed after 6 weeks (p<0.05). The differences in change of trunk muscle thickness before training, after 6-week training between groups, TrA and MF of low velocity MHRT were significantly higher (p<0.05). Conclusion: Based on the results of the current study, the velocity of MHRT was shown to affect change of trunk muscle thickness in healthy adults. In particular, low velocity MHRT may serve as a useful method to provide for TrA, MF thickness improvement related to trunk stabilizers.

Comparison of Difference of the Gluteus Medius Muscle Fiber Thickness during maximum muscle contraction between Chronic Low Back Pain with Gluteus Medius Weakness and Healthy Subject (중둔근 약화를 가진 만성요통환자와 건강한 대상자간 중둔근 최대 근수축 시 근섬유별 두께 비교)

  • Lee, Sang-Wk;Kim, Suhn-Yeop;Yang, Jin-Mo;Park, Seong-Doo
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.10 no.1
    • /
    • pp.71-82
    • /
    • 2015
  • PURPOSE: The aim of this study is to compare changes in the thickness of the gluteus medius muscle fiber between chronic low back pain(clbp) with gluteus medius weakness and healthy subject. METHODS: Ultrasound imaging was used to measure in the thickness of each fiber of the gluteus medius muscle based on maximal muscle contraction during abduction motion of the hip joint in a healthy group (11 subjects) and a chronic CLBP group (21 subjects). An independent t-test was performed to analyze the difference of thickness in each fiber of the gluteus medius muscle and the rate of changes in the fibers in the two groups. RESULTS: The fiber thickness changes in the gluteus medius muscle were significantly lower for the posterior fiber in the CLBP group compared to the healthy group (p<0.01). The changes in rate of difference of thickness the posterior part of the gluteus medius muscle was significantly lower in the CLBP group than in the healthy group (p<0.05). CONCLUSION: The findings of this study CLBP patients with weakness of the gluteus medius muscle that lower for the posterior fiber's difference of thickness and rate of change in the CLBP group compared to the healthy group. Indicate that rehabilitation of CLBP patients with weakness of the gluteus medius muscle should consider the functions of posterior fiber of the gluteus medius muscle.

Analysis for Relation of Oxide Thickness and Subthreshold Swing of Asymmetric Double Gate MOSFET (비대칭 DGMOSFET의 산화막 두께와 문턱전압이하 스윙의 관계 분석)

  • Jung, Hakkee;Cheong, Dongsoo
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2013.10a
    • /
    • pp.698-701
    • /
    • 2013
  • This paper has presented the change of subthreshold swings for gate oxide thickness of asymmetric double gate(DG) MOSFET, and solved Poisson equation to obtain the analytical solution of potential distribution. The symmetric DGMOSFET is three terminal device. Meanwhile the asymmetric DGMOSFET is four terminal device and can separately determine the bias voltage and oxide thickness for top and bottom gates. As a result to observe the subthreshold swings for the change of top and bottom gate oxide thickness, we know the subthreshold swings are greatly changed for gate oxide thickness. Especially we know the subthreshold swings are increasing with the increase of top and bottom gate oxide thickness, and top gate oxide thickness greatly influences subthreshold swings.

  • PDF