Observation of Shape after sinter of Dental Co-Cr sinter metal (치과용 Co-Cr sinter metal의 소결 후 변형비교)

  • Song, Joon-Boo;Kim, Kap-Jin
    • Journal of Technologic Dentistry
    • /
    • v.38 no.3
    • /
    • pp.127-133
    • /
    • 2016
  • Purpose: Currently advanced in Dental CAD/CAM technology increase a use of Co-Cr sinter metal block at Dental CAD/CAM part traditionally it has been being used with metal casting method. There is an advantage that can leave out a step of investment and casting as well as reducing a working time to compare with conventional casting method in a dry milling. Methods: In this research, compare a deformation of before and after sinter result of Co-Cr sinter metal block. Design a specimen figure by 3D CAD software and transformed it to a STL file can be used at Dental CAD/CAM. With a transformed STL file, milled a Co-Cr sinter metal specimen by using a Dental CAD/CAM dry milling machine. It arrived at the following conclusions after measuring an outer form and thickness of a machined specimen and then after sinter measure it again in a way of before sinter measurement method. Results: It is confirmed that there is no error while a 3D design figure specimen is transformed to a Dental CAD data. It is observed that there is no error at Co-Cr sinter metal specimen which consider a length of single coping and bridge. Conclusion: It is observed that there is no deformation at a specimen of AS05 and AB05 are made of 0,5mm thickness. On the other hand, the out of range of deformation is observed at a specimen of AS10 and AB10 which are made of 1mm thickness.

Study of the Axial Length/Corneal Radius Ratio in Determining the Refractive State of the Eye (굴절이상과 안축장/각막곡률반경 비와의 관계에 관한 연구)

  • Seo, Y.W.;Choe, Y.J.
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.4 no.2
    • /
    • pp.23-31
    • /
    • 1999
  • The purpose of this study is to evaluate the relationship between axial length/corneal radius ratio and refractive error for human eye. Ocular components were measured Baush & Lomb keratometer, Holden-Payor pachometer, and Stoz Compuscan. Refractive error was measured by subjective refraction. The results were as follows; 1) Spherical equivalent refractive error and axial length/corneal radius ratio was very highly correlated with the correlation coefficient for -0.89. 2) Axial length/corneal radius ratio and axial length, vitreous chamber depth were highly correlated that the correlation coefficients were 0.82, 0.80 respectively. 3) Axial length/corneal radius ratio and anterior chamber depth, corneal power, corneal radius, lens power were correlated with the correlation coefficients for 0.57, 0.40, -0.39, -0.35 respectively. 4) There were no significant correlation between axial length/corneal radius ratio and lens thickness, and corneal thickness.

  • PDF

Development of Contact-Type Thickness Measurement Machine using LVDT Sensors (LVDT센서를 이용한 접촉식 두께자동측정기 개발)

  • Shin, Ki-Yeol;Hwang, Seon
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.14 no.4
    • /
    • pp.151-159
    • /
    • 2015
  • In this study, we developed an automated contact-type thickness measurement machine that continuously and precisely measures the thickness of a PCB module product using multi-LVDT sensors. The system contains a measurement part to automatically measure the thickness in real time according to the set conditions with an alignment supply unit and unloading unit to separate OK and NG products. The sensors were calibrated before assembly in the measuring machine, and precision and accuracy performance tests were also performed to reduce uncertainty errors in the measurement machine. In the calibration test, the precision errors of the LVDT sensor were determined to be $1-3{\mu}m$ as 0.1% at the measuring range. A measurement error of 0.8 mm and 1.0 mm thickness test standards were found to be $1{\mu}m$ and $4{\mu}m$, and the standard deviations of two 1.0 mm products were measured as $14{\mu}m$ and $8{\mu}m$, respectively. In the measurement system analysis, the accuracies of test PCB standards were found to be $2{\mu}m$ and $3{\mu}m$, respectively. From the results of gage repeatability and reproducibility (R & R) crossed, we found that the machine is suitable for the measurement and process control in the mass production line as 7.92% of total gage R & R and in seven distinct categories. The maximum operating speed was limited at 13 pcs/min, showing a value good enough to measure.

Reliability of rehabilitative ultrasound imaging for measuring the gluteus maximus muscle at rest and during contraction

  • Jeong, Ju-Ri;Lee, Su-Jin;Lee, Wan-Hee
    • Physical Therapy Rehabilitation Science
    • /
    • v.6 no.1
    • /
    • pp.7-13
    • /
    • 2017
  • Objective: The aim of this study was to investigate the inter-rater and intra-rater reliability of rehabilitative ultrasound imaging (RUSI) for measurement of muscle thickness with changes in angles of the gluteus maximus (GM) at rest and during contraction. Design: Cross-sectional study. Methods: Twenty-two healthy men volunteered for this study. GM muscle images were obtained in the resting position and during prone hip extension with knee flexion at hip abduction angles of $0^{\circ}$ and $30^{\circ}$, respectively. Two examiners randomly measured the thickness of the GM twice in three different positions. The first position was a comfortable prone position. The second position was prone hip extension with knee flexion (PHEKF) to $90^{\circ}$. The third position was achieved by hanging a 1-kg weight on the ankle of the lifted leg during PHEKF with the angle of the lifted leg the same as the second position. Intra-class correlation coefficients (ICCs), standard error measurements, and minimal detectable changes were used to estimate reliability. Results: The intra-rater reliability ICCs (95% confidence interval) of the GM were >0.870, indicating good reliability. Inter-rater reliability ICCs ranged from 0.668 to 0.913. The reliability of measurements of muscle thickness at each position was similar to the reliability of the angle change. Differences in muscle thickness and ratios for each position with $0^{\circ}$ and $30^{\circ}$ of hip abduction were not statistically significant. Conclusions: In the present study, the intra-rater reliability of muscle thickness measurements of the GM was good, and the inter-rater reliability was moderate to good. Reliable RUSI measurements of wide and large muscles, such as the GM muscle at rest and during contraction, are feasible. Further investigation is required to establish the reproducibility of the protocols presented in this study.

Noise Level Evaluation According to Slice Thickness Change in Magnetic Resonance T2 Weighted Image of Multiple Sclerosis Disease (다발성 경화증 질환의 자기공명 T2 강조영상에서 단면 두께 변화에 따른 잡음 평가)

  • Hong, Inki;Park, Minji;Kang, Seong-Hyeon;Lee, Youngjin
    • Journal of radiological science and technology
    • /
    • v.44 no.4
    • /
    • pp.327-333
    • /
    • 2021
  • Magnetic resonance imaging(MRI) uses strong magnetic field to image the cross-section of human body and has excellent image quality with no risk of radiation exposure. Because of above-mentioned advantages, MRI has been widely used in clinical fields. However, the noise generated in MRI degrades the quality of medical images and has a negative effect on quick and accurate diagnosis. In particular, examining a object with a detailed structure such as brain, image quality degradation becomes a problem for diagnosis. Therefore, in this study, we acquired T2 weighted 3D data of multiple sclerosis disease using BrainWeb simulation program, and used quantitative evaluation factors to find appropriate slice thickness among 1, 3, 5, and 7 mm. Coefficient of variation and contrast to noise ratio were calculated to evaluate the noise level, and root mean square error and peak signal to noise ratio were used to evaluate the similarity with the reference image. As a result, the noise level decreased as the slice thickness increased, while the similarity decreased after 5 mm. In conclusion, as the slice thickness increases, the noise is reduced and the image quality is improved. However, since the edge signal is lost due to overlapped signal, it is considered that selecting appropriate slice thickness is necessary.

The Correlation of Refractive Error and Ocular Dimensions in Older Age (고령의 연령에서 굴절이상과 안광학 성분들의 연관성 분석)

  • Lim, Byung Kwan;Jeon, Soon-Woo;Jeong, Youn Hong
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.3
    • /
    • pp.293-297
    • /
    • 2011
  • Purpose: This study was to know the correlation among refractive error and the dimensions of ocular components on older adults. Methods: The subjects were 95 older age who had no eye diseases. The refractive error, corneal radius, corneal diopter, axial length, anterior chamber depth and lens thickness were measured and analysed. Results: The axial length(AL)/corneal radius(CR) ratio was positively correlated with the corneal diopter, axial length, the anterior chamber depth. Then it was negatively correlated with corneal radius. It was shown that the highest correlation was between the corneal diopter and axial length (r = -0.545, p = 0.000). The spherical equivalent of the refractive error was negatively correlated with the AL/CR ratio. Conclusions: It was shown that the AL/CR ratio was a very important indicator for diagnosing the refractive error of the old age.

Prediction of Frost Layer Growth on a Cold Plate (저온 평판에서의 서리층 성장 예측)

  • Jhee, Sung;Lee, Kwan-Soo;Yeo, Moon-Su
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.9
    • /
    • pp.1325-1331
    • /
    • 2002
  • This study presents a numerical model to predict the behavior of frost layer growth. The characteristics of the heat and mass transfer inside the frost layer are analyzed by coupling the air flow with the frost layer. The present model is validated by comparing with the several other analytical models. It has been known that most of the previous models cause considerable errors depending on the working conditions or correlations used in predicting the frost thickness growth, whereas the model in this work estimates the thickness of the frost layer more accurately within an error of 10% in comparison with the experimental data. Simulation results are presented for variations of heat and mass transfer during the frost formation and for the behavior of frost layer growth along the direction of air flow.

Error Reduction of Sliding Mode Control Using Sigmoid-Type Nonlinear Interpolation in the Boundary Layer

  • Kim, Yoo-K.;Jeon, Gi-J.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.1810-1815
    • /
    • 2003
  • Sliding mode control with nonlinear interpolation in the boundary layer is proposed. A modified sigmoid function is used for nonlinear interpolation in the boundary layer and its parameter is tuned by a fuzzy logic controller. The fuzzy logic controller that takes the distance between the system state and the sliding surface as its input guides the choice of parameter of the modified sigmoid function and the parameter is on-line tuned. Owing to the decreased thickness, the proposed method has better tracking performance than the conventional linear interpolation method. To demonstrate its performance, the proposed control algorithm is applied to a simple nonlinear system model.

  • PDF

Detection of Second-Layer Corrosion in Aging Aircraft Fuselage

  • Kim, Noh-Yu;Achenbach, J.D.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.26 no.6
    • /
    • pp.417-426
    • /
    • 2006
  • A Digital X-ray imaging system using Compton backscattering has been developed to obtain a cross-sectional profile and mass loss of corroded lap-splices of aging aircraft from density variation. A slit-type camera was designed to focus on a small scattering volume inside the material, from which the backscattered photons are collected by a collimated scintillator detector for interpretation of material characteristics. The cross section of the lap-joint is scanned by moving the scattering volume through the thickness direction of the specimen. The mass loss of each layer has been estimated from a Compton backscatter A-scan to obtain the thickness of each layer including the aluminum sheet, the corrosion layer and the sealant. Quantitative information such as location and width of planar corrosion in the lap splices of fuselages is obtained by deconvolution using a nonlinear least-square error minimization method(BFGS method): A simple reconstruction model is also introduced to overcome distortion of the Compton backscatter data due to attenuation effects attributed to beam hardening and quantum noise.

Process Design of Superplastic Forming/Diffusion Bonding by Using Design of Experiment (실험계획법을 이용한 초소성 성형/확산접합의 공정설계)

  • Song, J.S.;Kang, Y.K.;Hong, S.S.;Kwon, Y.N.;Lee, J.H.;Kim, Y.H.
    • Transactions of Materials Processing
    • /
    • v.16 no.2 s.92
    • /
    • pp.144-149
    • /
    • 2007
  • The superplastic forming/diffusion bonding(SPF/DB) is widely used in the automotive and aerospace industry because it has great advantage to produce complex, light and strong parts. But the superplastic forming process requires much forming time and generates excessive thinning in the thickness distribution of formed part. It is necessary to minimize trial and error for SPF/DB Process. Finite element analysis using $L_{18}$ orthogonal may table of Taguchi method for 3-Sheet D/B process is carried out. Through the study, effect of process parameters, such as DH region size, thickness and friction coefficient, is evaluated and the optimum condition is derived.