사고시 대응 정밀 베타선량계 개발 (Development of Precise Beta Dosimeter)

  • 이원근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 추계학술대회 논문집 학회본부
    • /
    • pp.468-470
    • /
    • 1996
  • The use of thermoluminescent dosimeters (TLDs) for beta dosimetry has been encumbered by the energy-dependent responses of TLDs to beta radiation. This energy-dependent response is due to the low penetrating ability of beta particles. Thus the determination of the beta dose imparted to an exposed TLD chip can be accurately determined only if the energy distribution of beta radiation is correctly accounted for. So precise beta dosimeter used TLD chips place under several aluminum filters of varying thicknesses and developed to correctly determine doses due to radiation fields where the beta energy distribution is unknown.

  • PDF

파노라마 촬영시 눈과 갑상선에 미치는 표면선량에 관한 연구 - TLD, PLD 중심으로 - (A study on the effects of scattering dose on eyes and thyroid for panoramagraphy - Focus on TLD and PLD -)

  • 동경래
    • 한국콘텐츠학회:학술대회논문집
    • /
    • 한국콘텐츠학회 2009년도 춘계 종합학술대회 논문집
    • /
    • pp.1118-1123
    • /
    • 2009
  • 파노라마 촬영 시 눈과 갑상선의 표면선량 실험은 광주지역 10개 병원을 대상으로 열형광선량계(Thermoluminescent dosimeter, TLD)와 형광유리선량계(Photoluminescent dosimeter, PLD)를 이용하여 각각 병원에서 사용하는 조건으로 측정(measurement)하였다. ICRP 60과 ICRP 73에서 권고한 눈에 대한 허용기준은 15mSv, 갑상선에 대한 허용기준은 연간 1mSv이다. 왼쪽 눈(Left Eye)의 TLD와 PLD값은 각각 0.19mSv와 0.24mSv, 오른쪽 눈(Right Eye)의 TLD와 PLD의 값은 0.23mSv와 0.25mSv, 갑상선의 TLD와 PLD의 값은 0.08mSv와 0.25mSv로 허용기준치를 초과하지 않았다. 또한 각 장기에 대한 TLD와 PLD의 비교에서는 왼쪽 눈과 갑상선이 유의한 차이가 있다고 볼 수 있고(p<0.01), 오른쪽 눈은 유의한 차이가 없다고 볼 수 있다(p>0.05). 각 병원에서 사용하는 파노라마 기기로 눈과 갑상선에 미치는 선량을 TLD와 PLD로 측정 하였을 때 눈과 갑상선의 표면선량은 ICRP 60에서 권고한 선량을 넘지 않았지만, 확률적 영향이 일어날 수 있으므로 모든 준위의 선량에 대해서 고려되어야 한다.

  • PDF

자기장이 열형광선량계의 글로우 곡선에 미치는 영향 (The Effects of Magnetic Field on TLD Glow Curve)

  • 제재용;강은보
    • 한국방사선학회논문지
    • /
    • 제7권6호
    • /
    • pp.415-418
    • /
    • 2013
  • 방사선을 조사한 시료를 가열하면 시료로부터 흡수된 에너지의 일부가 더 긴 파장의 빛으로 방출되는 것을 이용한 것이 열형광선량계이다. 본 연구의 목적은 피폭선량계로 널리 이용되는 8개의 TLD-100에 동일한 조건에서 열처리와 방사선을 조사하여 자기장을 노출하지 않은 4개와 자기장에 노출시킨 4개를 글로우 곡선을 분석 하였다. 실험 결과 방사선 조사로 포획된 전자가 자기장 노출에 의해 낮은 트랩의 전자들 중 일부는 가전자대의 정공과 결합하여 48%의 피크 면적이 감소하였다. 낮은 트랩의 면적 감소로 인하여 자기장에 노출된 TLD-100은 낮은 선량을 나타내었다. 또한 낮은 트랩의 활성화 에너지는 1.6 eV와 1.5 eV로 나타났다.

LiF:Mg,Cu,Na,Si Teflon TLD의 열처리 특성 (Anneal Characteristics of LiF:Mg,Cu,Na,Si Teflon TLDs)

  • 남영미;정운혁;이대원;김현자;김기동
    • Journal of Radiation Protection and Research
    • /
    • 제22권3호
    • /
    • pp.135-141
    • /
    • 1997
  • 열처리 특성의 연구는 열형광선량계를 재 사용하는데 있어서 중요하다. 최근 개발된 디스크 형태 (직경 4.5 mm, 두께 약 $90mg/cm^2$)의 LiF:Mg,Cu,Na,Si Teflon TLD의 열처리 조건을 구하기 위하여 조사전열처리, 판독과정 및 판독 후 열처리의 순서로 연구하였다. Teflon TLD의 감마선 조사는 $^{60}Co$ 0.1 Gy로 하였다. LiF:Mg,Cu,Na,Si Teflon TLD의 열처리 특성의 연구는 전기로와 판독장치를 이용하여 열처리 온도와 열처리 시간을 변화시키면서, 측정반복횟수에 따른 열형광강도 변화를 관찰하는 방법으로 수행하였다. LiF:Mg,Cu,Na,Si Teflon TLD의 열처리 조건은 조사전 열처리를 $80^{\circ}C$에서 1 시간 한 후 $280^{\circ}C$까지 판독하고 판독 후 열처리를 $270^{\circ}C$에서 20 초간 하는 것으로 결정되었고, 이 조건에서 10 회 반복측정시 원래의 열형광강도는 5%의 감소를 보였다.

  • PDF

Determination of Exposure during Handling of 125I Seed Using Thermoluminescent Dosimeter and Monte Carlo Method Based on Computational Phantom

  • Hosein Poorbaygi;Seyed Mostafa Salimi;Falamarz Torkzadeh;Saeid Hamidi;Shahab Sheibani
    • Journal of Radiation Protection and Research
    • /
    • 제48권4호
    • /
    • pp.197-203
    • /
    • 2023
  • Background: The thermoluminescent dosimeter (TLD) and Monte Carlo (MC) dosimetry are carried out to determine the occupational dose for personnel in the handling of 125I seed sources. Materials and Methods: TLDs were placed in different layers of the Alderson-Rando phantom in the thyroid, lung and also eyes and skin surface. An 125I seed source was prepared and its activity was measured using a dose calibrator and was placed at two distances of 20 and 50 cm from the Alderson-Rando phantom. In addition, the Monte Carlo N-Particle Extended (MCNPX 2.6.0) code and a computational phantom with a lattice-based geometry were used for organ dose calculations. Results and Discussion: The comparison of TLD and MC results in the thyroid and lung is consistent. Although the relative difference of MC dosimetry to TLD for the eyes was between 4% and 13% and for the skin between 19% and 23%, because of the existence of a higher uncertainty regarding TLD positioning in the eye and skin, these inaccuracies can also be acceptable. The isodose distribution was calculated in the cross-section of the head phantom when the 125I seed was at two distances of 20 and 50 cm and it showed that the greatest dose reduction was observed for the eyes, skin, thyroid, and lungs, respectively. The results of MC dosimetry indicated that for near the head positions (distance of 20 cm) the absorbed dose rates for the eye lens, eye and skin were 78.1±2.3, 59.0±1.8, and 10.7±0.7 µGy/mCi/hr, respectively. Furthermore, we found that a 30 cm displacement for the 125I seed reduced the eye and skin doses by at least 3- and 2-fold, respectively. Conclusion: Using a computational phantom to monitor the dose to the sensitive organs (eye and skin) for personnel involved in the handling of 125I seed sources can be an accurate and inexpensive method.

A STUDY ON THE EFFECTS OF SCATTERING DOSE ON EYES AND THYROID FOR PANORAMAGRAPHY (Focus on TLD and PLD)

  • Jung, Yeun;Dong, Kyung-Rae;Kweon, Dae-Cheol;Dieter, Kevin;Goo, Eun-Hoe;Ahn, Se-Youn;Chung, Jae-Eun
    • Journal of Radiation Protection and Research
    • /
    • 제35권1호
    • /
    • pp.1-5
    • /
    • 2010
  • This study concerning the surface dose of eye and thyroid from panoramagraphy used thermoluminescent dosimeter (TLD) and photoluminescent dosimeter (PLD) to take measurements at ten hospitals in the Gwangju metropolitan area. The recommendations from ICRP 60 and ICRP 73 on the allowance standard for eye are 15 mSv and for thyroid is 1 mSv. The left eye TLD and PLD values are 0.19 mSv and 0.24 mSv respectively. The right eye TLD and PLD values are 0.23 mSv and 0.25 mSv respectively. Thyroid TLD and PLD values are 0.08 mSv and 0.25 mSv respectively and did not exceed the allowance standards(p<0.001). Also comparisons are made between TLD and PLD for each organ and PLD has higher dose measurements than TLD. There are statistically significant differences in left eye measurements and thyroid measurements (p<0.01). There is no significant difference in measurements for the right eye (p>0.05). The TLD and PLD measured dose from panoramagraphy instruments on eyes and thyroid from each hospital did not exceed the recommended dose from ICRP 60 for surface dose measurements. However, due to the probability of influence, consideration should be made for all levels of dose.

Intercomparison Exercise at Harshaw 6600, DVG-02TM, and D-Shuttle Dosimeters for the Individual Monitoring of Ionizing Radiation

  • Kim, Dmitriy Spartakovich;Murayama, Kentaro;Nurtazin, Yernat;Koguchi, Yasuhiro;Kenzhin, Yergazy;Kawamura, Hiroshi
    • Journal of Radiation Protection and Research
    • /
    • 제44권2호
    • /
    • pp.79-88
    • /
    • 2019
  • Background: The main goal of experiments is to compare various operational and technical characteristics of D-Shuttle semiconductor personal dosimeters of the Japanese company "Chiyoda Technol Corporation" and Harshaw thermoluminescent dosimeters (TLD) manufactured by "Thermo Fisher Scientific" and DTL-02 of the Russian Research and Production Enterprise (RPE) "Doza" by their occupational and calibration exposure at various dose equivalents from 0.5 to 20 mSv of gamma-radiation. Materials and Methods: Besides dosimeters DTL-02, D-Shuttle and Harshaw TLD, there were also used: (1) the primary reference radionuclide source Hopewell Designs IAEA: G10-1-12 with $^{137}Cs$ isotope (an error is not more than 6% and activity is 20 Ci), and (2) the verification device UPGD-2M of RPE "Doza" and installed in the National Center for Expertise and Certification of the Republic of Kazakhstan (Kapchagai, the National Center for Expertise and Certification). Results and Discussion: The main results of researches are the following: (1) TLDs for Harshaw 6600 and DVG-02TM have an approximately equal measurement accuracy of the individual dose equivalents in the range from 0.5 to 20 mSv of gamma-radiation. (2) Advantages of dosimeters for Harshaw 6600 are due to the high measurement productivity and opportunity to indicate the dose on the skin $H_p$(0.07). Advantages of DVG-02TM consist of operation simplicity and lower cost than of Harshaw 6600. (3) D-Shuttles are convenient for use in the current and the operational monitoring of ionizing radiation. Measurement accuracy and 10% linearity of measurements are ensured when D-Shuttle is irradiated with dose equivalents below 1 mSv at the equivalent dose rate not higher than $3mSv{\cdot}hr^{-1}$. This allows using D-Shuttle at a routine technological activity. Conclusion: The obtained results of experiments demonstrate advantages and disadvantages of D-Shuttle semiconductor dosimeters in comparison with two TLD systems of DVG-02TM and Harshaw 6600.

제작된 선량 검증용 IMRT 팬텀의 몬테칼로 시뮬레이션: 예비적 연구 (A Monte Carlo Simulation for the Newly Developed Head-and-Neck IMRT Phantom: a Pilot Study)

  • 강세권;정광호;주라형;조병철;오도훈;김수산;김경주;배훈식;한영이;신은혁;박성호;임천일
    • 한국의학물리학회지:의학물리
    • /
    • 제18권3호
    • /
    • pp.126-133
    • /
    • 2007
  • 세기조절방사선치료(Intensity modulated radiation therapy, IMRT) 선량의 정확도를 원격으로 점검할 수 있는 시스템 구축을 목적으로, 두경부용 팬텀을 제작하였다. 팬텀은 공기 및 뼈 구조물의 교체 장착을 통해, 균질 혹은 비균질 팬텀으로 이용할 수 있다. 일차적으로 단일 빔 및 세 빔의 조사에 대한 몬테칼로(Monte Carlo, MC) 전산모사를 시행하고, 이온 전리함 및 열형광선량계(thermoluminescent dosimeter, TLD)를 이용한 측정과 비교하였다. TLD의 판독은 독립된 두 기관에서 수행하였다. 단일 빔의 경우, 균질 및 비균질 팬텀에 대한 이온 전리함 측정 결과는 MC전산모사 결과와 대체로 2% 수준에서 일치하였으며, TLD 의 경우에는 기관에 따라 2% 혹은 7%수준의 차이를 보였다. 세 빔을 이용한 비교의 경우에는, 이온 전리함은 -5% 수준, TLD의 경우에는 $+2{\sim}+3%$ 수준의 차이를 보였다. 원격 선량 검증을 위해서는 TLD 판독의 신뢰도 향상이 필요한 것으로 판단되었다. MC 전산모사는 새로운 팬텀 개발 시에, 선량 측정값의 신뢰도 확보에 이용될 수 있다.

  • PDF

$Al_2O_3$ 열형광(熱螢光) 특성(特性)을 이용(利用)한 감마선(線)의 측정(測定) 및 임상응용(臨床應用) (Gamma Dosimetry and Clinical Application with $Al_2O_3$ Thermoluminescent Dosimeter)

  • 추성실;박창윤
    • Journal of Radiation Protection and Research
    • /
    • 제9권1호
    • /
    • pp.3-10
    • /
    • 1984
  • The properties of $Al_2O_3$ thermoluminescent phosphor have been observed to apply for gamma dosimetry in vivo. Glow peaks at 380, 420, 490 kelvin temperature with emission in the blue region have been detected and calculated as 1.4 eV the activation energy by means of heat response rising time method. Sensitization and supralinearity in $Al_2O_3$ phosphor could be consistently explained by the deep trap model. Studies of the thermoluminescence growth rate with gamma ray exposure showed linearly to $10^4$ Roentgen and then supralinear rate detected 1.2 power of exposure dose sensitization of $Al_2O_3$ is described five times more than TLD-100 and the fading time is shorter and then tried to apply for gamma dosimetry in vivo.

  • PDF