• Title/Summary/Keyword: Thermocline

Search Result 201, Processing Time 0.025 seconds

Interference of Acoustic Signals Due to Internal Waves in Shallow Water

  • Na Young-Nam
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • spring
    • /
    • pp.189-197
    • /
    • 1999
  • To investigate internal waves (IW) effect on acoustic wave propagation, m analysis is conducted on mode travel time and model simulation. Based on the thermistor string data, it can be shown that the thermocline depth variation may cause travel time difference as much as 4-10 ms between mode 1 and 2 over range 10 km. This travel time difference causes interference among modes and thus fluctuation from range-independent stratified ocean structure. In real situations, however, there exist additionally spatial variation of IW. Model simulation with all modes and simple IW shows clear responses of acoustic signals to IW, amplitude and phase fluctuation.

  • PDF

A PRELIMINARY REPORT ON THE DISTRIBUTION, OF MICROPLANKTON IN TWO DIFFERENT AREAS OF THE EAST CHINA SEA (동지나해의 두 해역에 있어서 미세플랑크톤의 분포(예보))

  • CHOE Jung Shin
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.11 no.3
    • /
    • pp.123-127
    • /
    • 1978
  • Distributions of microplankton in two different regions of the East China Sea were studied based on the plankton samples collected by R. V. Umitaka Maru of Fisheries University of Tokyo, Japan in September, 1975. The abundance distribution and species composition of the two areas were interpreted with their temperature-salinity properties. The two areas aye characterized by differences in the depth of thermocline, the nature of surface and bottom waters, and the abundance and species composition of microplankton.

  • PDF

Theoretical Analysis of the Charging Process with Perfectly Mixed Region in Stratified Thermal Storage Tanks (완전혼합영역을 갖는 성층축열조의 충전과정에 대한 이론적인 해석)

  • Yoo, H.;Pak, E.T.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.7 no.2
    • /
    • pp.184-195
    • /
    • 1995
  • A theoretical one-dimensional model for the charging process in stratified thermal storage tanks is established presuming that the fluid ensuing from the tank inlet creates a perfectly mixed, layer above the thermocline. Both the generic and asymptotic closed-form solutions are obtained via the Laplace transformation. The asymptotic solution describes the nature of the charging pertaining to the case of no thermal diffusion, whereas the generic solution is of practical importance to understand the role of operating parameters on the stratification. The present model is validated through comparison with available experimental data, where they agree well with each other within a reasonable limit. An interpretation of the exact solution entails two important features associated with the charging process. The first is that an in-crease in the mixing depth $h_m$ causes a relatively slow temperature rise in the perfectly mixed region, but on the other hand it results in a faster decay of the overall temperature gradient across the thermocline. Next is the predominance of the mixing depth in the presence of the prefectly mixed region. In such a case the effect of the Peclet number is marginal and there-fore the thermal characteristics are solely dependent on the mixing depth paticularly for large $h_m$. The Peclet number affects significantly only for the case without mixing. Variation of the storage efficiency in response to the change in the mass flow rate agrees favorably with the published experimental results, which confirms the utility of the present study.

  • PDF

Exploring the Dynamics of Dissolved Oxygen and Vertical Density Structure of Water Column in the Youngsan Lake (인공호소인 영산호의 용존산소 분포와 수층 성층구조의 연관성 분석)

  • Song, Eun-Sook;Cho, Ki-An;Shin, Yong-Sik
    • Journal of Environmental Science International
    • /
    • v.24 no.2
    • /
    • pp.163-174
    • /
    • 2015
  • The Youngsan Lake was constructed to supply agricultural water to the extensive rice fields in the basin of the lake in 1981. Hypoxia has often developed in the bottom water of the lake during the warm season although the water depth is relatively shallow (< 16 m). We investigated the spatial and temporal variations of dissolved oxygen (DO) and physical properties such as water temperature, salinity and turbidity to elucidate the effects of change in physical properties on DO dynamics in the lake. Vertical profiles of DO, temperature, salinity, and water density were also explored to verify the development of stratification in relation to DO variation in the water column. Hypoxia (DO < $2mg\;L^{-1}$) was not observed in the upper regions whereas hypoxia was detected in the lower regions during the warm season. Thermocline generally developed in the lower regions during the warm season unlike the previous studies in which no thermocline was observed. However, water column was well mixed when freshwater water was discharged from the reservoir through the sluice gate of the dike. DO concentrations also decreased when halocline or pycnocline developed during the dry season suggesting that the vertical stratification of water column affects DO dynamics although the water depth is shallow in the Youngsan lake.

Observations of the Cheju Current

  • Suk, Moon-Sik;Pang, Ig-Chan;Teague, William J.;Chang, Kyung-Il
    • Journal of the korean society of oceanography
    • /
    • v.35 no.3
    • /
    • pp.129-152
    • /
    • 2000
  • The Cheju Current (CC), defined here as a mean eastward flow in the Cheju Strait, mostly carries water of high temperature and salinity originating from the Kuroshio in winter and spring, the Cheju Warm Current Water (CWCW). The strong core of the eastward component of the CC is found close to Cheju Island (Cheju-Do, hereafter) in winter and spring with a peak speed of about 17.0 cm/s. The eastward flow weakens towards the northern Cheju Strait, and a weak westward flow occurs occasionally close to the southern coast of Korea. The volume transport ranges from 0.37 to 0.45 Sv(1 Sv=10$^6$ m$^3$/s) in winter and spring. Seasonal thermocline and harocline are formed in summer and eroded in November. The occurrence of the CWCW is confined in the southern Cheju Strait close to Cheju-Do below the seasonal thermocline in summer and fall, and cold water occupies the lower layer north of the CWCW which is thought to be brought into the area from the area west of Cheju-Do along with the CWCW. Stratification acts to increase both the speed of the CC with a peak speed of greater than 30 cm/s and the vertical shear of the along-strait currents. The strong core of the CC detached from the coast of Cheju-Do and shifted to the north during the stratified seasons. The volume transport in summer and fall ranges 0.510.66 Sv, which is about 1.5 times larger than that in winter and spring. An annual cycle of the cross-strait sea level difference shows its maximum in summer and fall and minimum in winter and spring, whose tendency is consistent with the annual variability of the CC and its transport estimated from the ADCP measurements. Moored current measurements west of Cheju-Do indicate the clockwise turning of the CC, and the moored current measurements in the Cheju Strait for 1530 days show the low-frequency variability of the along-strait flow with a period of about 37 days.

  • PDF

Application of CE-QUAL-W2 [v3.2] to Andong Reservoir: Part I: Simulations of Hydro-thermal Dynamics, Dissolved Oxygen and Density Current

  • Bhattarai, Prasid Ram;Kim, Yoon-Hee;Heo, Woo-Myoung
    • Korean Journal of Ecology and Environment
    • /
    • v.41 no.2
    • /
    • pp.247-263
    • /
    • 2008
  • A two-dimensional (2D) reservoir hydrodynamics and water quality model, CE-QUAL-W2, is employed to simulate the hydrothermal behavior and density current regime in Andong Reservoir. Observed data used for model forcing and calibration includes: surface water level, water temperature, dissolved oxygen and suspended solids concentration. The model was calibrated to the year of 2003 and verified with continuous run from 2000 till 2004. Without major adjustments, the model accurately simulated surface water levels including the events of large storm. Deep-water reservoirs, like Andong Reservoir, located in the Asian Monsoon region begin to stratify in summer and overturn in fall. This mixing pattern as well as the descending thermocline, onset and duration of stratification and timing of turnover phenomenon were well reproduced by the Andong Model. The temperature field and distinct thermocline are simulated to within $2^{\circ}C$ of observed data. The model performed well in simulating not only the dissolved oxygen profiles but also the metalimnetic dissolved minima phenomenon, a common1y occurring phenomenon in deep reservoirs of temperate regions. The Root Mean Square Error (RMSE) values of model calibration for surface water elevation, temperature and dissolved oxygen were 0.0095 m, $1.82^{\circ}C$, and $1.13\;mg\;L^{-1}$, respectively. The turbid storm runoff, during the summer monsoon, formed an intermediate layer of about 15 m thickness, moved along the metalimnion until being finally discharged from the dam. This mode of transport of density current, a common characteristic of various other large reservoirs in the Asian summer monsoon region, was well tracked by the model.

A study on vertical distribution observation of giant jellyfish (Nemopilema nomurai) using acoustical and optical methods (음향 및 광학기법을 이용한 노무라입깃해파리 (Nemopilema nomurai)의 수층별 분포 관찰에 관한 연구)

  • Lee, Kyoung-Hoon;Kim, In-Ok;Yoon, Won-Duk;Shin, Jong-Keun;An, Heui-Chun
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.43 no.4
    • /
    • pp.355-361
    • /
    • 2007
  • A giant jellyfish (Nemopilema nomurai), which is presumed developing in the East China Sea, is recently one of major issues in the Northeast Asia region due to its fatal damage to the fishery. The biomass estimates have generally been conducted by trawl sampling and sighting survey methods. The biological research is also needed to clarify such environmental origin or diurnal migration patterns. While trawl sampling or sighting survey methods are effective to investigate its density estimates in its distributed community of near bottom or surface, they have a problem in investigation on the vertical distribution of jellyfishes. In this case, an echo sounding detection would have an advantage to survey it more extensively and effectively. This trial was conducted to observe the vertical distribution of giant jellyfish, where thermocline strongly formed, during mooring at each station of the East China Sea and southern coastal area using acoustical and optical methods. By the results, they were observed to exit and move at the water column under the thermocline using the optical camera and echo sounder system, and the information was analyzed to find out the acoustical sound scattering characteristics relatives to 120kHz frequency. These results can be utilized effectively to estimate the vertical distribution and biomass of Giant jellyfish with comparing results from trawl sampling and sighting survey methods, hereafter.

Oceanic Characteristics of Fishing Ground for Yellowfin and Bigeye Tunas Caught by Korean Tuna Longline Fishery in the Tropical Pacific (열대 태평양 연승어업 대상 황다랑어와 눈다랑어 어장 분포의 해황 특성)

  • YANG Won Seok;CHO Kyu Dae;MOON Dae Yeon;KOH Jeong Rack
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.38 no.3
    • /
    • pp.196-204
    • /
    • 2005
  • The horizontal and vertical distribution of yellowfin tuna, Thunnus albacares (Bonnaterre) and bigeye tuna, Tunnus obesus (Lowe) in relation to oceanic conditions such as thermal structure produced during El Nino/La Nina episodes were analyzed on the basis of data sets for the catches and efforts from the Korean tuna longline fishery and for the oceanographic observations from the NOAA during 1982-2002 in the tropical Pacific. The high density of fishing ground appeared in the western Pacific ($5^{\circ}N-5^{\circ}S,\;160^{\circ}E-180^{\circ}W$) for yellowfin tuna and in the eastern Pacific ($5^{\circ}N-15^{\circ}S,\;130^{\circ}W-100^{\circ}W$) for bigeye tuna. yellowfin and bigeye tunas were mainly distributed at the 110-250 m layer and 245-312 m layer, respectively, in the western Pacific. However, in the eastern Pacific, they were mostly caught at the 116-161 m and 205-276 m layer for yellowfin tuna and bigeye tuna, respectively. It can be suggested that bigeye tuna be distributed in the deepest layer among tunas and show a vertical size stratification. It was observed that during the El Nino events the main fishing ground of yellowfin tuna shifted from the western Pacific toward the eastern Pacific. In the eastern Pacific which showed a higher density of bigeye tuna, the vulnerability of bigeye tuna caught by deep longline increased during the El Nino events due to deepening of thermocline layer and a more intensively distribution of the fish schools in the lower layer of thermocline during the El Nino events.

Effect of Design Factors on the Performance of Stratified Thermal Storage Tank (성층축열조의 성능에 대한 설계인자의 영향)

  • Chung Jae Dong;Park Joohyuk;Cho Sung-Hwan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.11
    • /
    • pp.1077-1083
    • /
    • 2004
  • This study is to systematically analyze the effect of various kinds of design factors on the performance of stratified thermal storage tank. Taguchi method, known as a very reasonable tool in the parametric study, is employed in the present work. Three dimensional unsteady numerical experiment is conducted for 4 design parameters of stratified thermal storage tank: inlet Reynolds number, Froude number, diffuser size d with 3 levels (Re=400, 800, 1200, Fr=0.5, 1.0, 2.0 and d=150 mm, 200mm, 300 mm) and diffuser shape with 2 levels. Orthogonal array $L_{18}(2{\times}3^7)$ is adopted for the analysis of variance. The result gives quantitative estimation of the various design parameters affecting the performance and helps to select the main factors for the optimum design of stratified thermal storage tank. Reynolds number is found to be the most dominant parameter and the diffuser shape plays significant role on the performance of stratified thermal storage tank. Based on this finding, the prior questions on the contribution of the diffuser shape proposed by the authors become clear. The optimum condition for the performance is a set of d=300mm, Re=800, and radial regulated plate diffuser. Conformation test shows the repeatability in the analysis and $1.3\%$ difference between the estimated thermocline thickness and that of numerical result.

An Estimation of the New Production in the Southern East Sea Using Helium Isotopes

  • Kim, Kyung-Ryul;Hahm, Do-Shik
    • Journal of the korean society of oceanography
    • /
    • v.36 no.1
    • /
    • pp.19-26
    • /
    • 2001
  • The biological pump is one of the important pumping mechanisms absorbing CO$_2$ from the atmosphere into the ocean and can be quantified by estimating new production. New production in the open ocean mostly depends on the supply of nitrate from the water below the mixed layer. While nitrate is affected by many biological processes, the helium isotope ($^3$He) is inert and has very simple physical properties. Using the $^3$He flux and the relation between $^3$He and NO${_3}\;{^-}$- within the thermocline, the nitrate flux supporting new production was estimated in the southern East Sea. The average ${\delta}^3$He within the mixed layer was -14$%_o$ and -l5.4$%_o$ in the winter and autumn, respectively. Through the year excess $^3$He occurs in the mixed layer except for a slight depletion of -17$%_o$ in summer. The $^3$He flux of 13$%_o$md$^{-1}$ associated with the concentration gradient at the air-sea interface was calculated from the product of the piston velocity and the excess $^3$He. Tritium decay within the mixed layer could support only 2$%_o$md$^{-1}$ of the flux. Thus, the remaining 11$%_o$md^{-1}$ could be attributed to the flux of tritiugenic $^3$He from the water below the mixed layer. Nitrate and $^3$He were positively correlated within the thermocline layer with the slope of 0.21 ${\mu}$mol kg$^{-1}$ $%_o\;^{-1}$. The annual nitrate flux estimated from the upward flux of $^3$He and the NO$_{3}\;{^-}$-$^3$He relation was 0.8${\pm}$0.2 mol(N) m$^{-2}$yr$^{-1}$. This flux corresponds to an annual new production of 64 g(C) m$^{-2}$yr$^{-1}$, which is consistent with that in the north-west Pacific.

  • PDF