Effect of Design Factors on the Performance of Stratified Thermal Storage Tank

성층축열조의 성능에 대한 설계인자의 영향

  • Published : 2004.11.01

Abstract

This study is to systematically analyze the effect of various kinds of design factors on the performance of stratified thermal storage tank. Taguchi method, known as a very reasonable tool in the parametric study, is employed in the present work. Three dimensional unsteady numerical experiment is conducted for 4 design parameters of stratified thermal storage tank: inlet Reynolds number, Froude number, diffuser size d with 3 levels (Re=400, 800, 1200, Fr=0.5, 1.0, 2.0 and d=150 mm, 200mm, 300 mm) and diffuser shape with 2 levels. Orthogonal array $L_{18}(2{\times}3^7)$ is adopted for the analysis of variance. The result gives quantitative estimation of the various design parameters affecting the performance and helps to select the main factors for the optimum design of stratified thermal storage tank. Reynolds number is found to be the most dominant parameter and the diffuser shape plays significant role on the performance of stratified thermal storage tank. Based on this finding, the prior questions on the contribution of the diffuser shape proposed by the authors become clear. The optimum condition for the performance is a set of d=300mm, Re=800, and radial regulated plate diffuser. Conformation test shows the repeatability in the analysis and $1.3\%$ difference between the estimated thermocline thickness and that of numerical result.

Keywords

References

  1. Park, J T., 2003, Development of present status and prospect of unutilized energy,Proc. of the SAREK '03 Winter Annual Conference, pp. 398-403.
  2. Dincer, I. and Rosen, M. A., 2002, Thermal Energy Storage, John Wiley & Sons, England
  3. Yoo, J I., 1989, Air-conditioning with chilledwater thermal storage, Mag. Soc. Air-Cond,and Refrig. Eng. Korea, Vol. 18, No.5, pp.427-436
  4. Zurigat, Y. H., Liche, P. R. and Ghajar, A. J,1991, Influence of inlet geometry on mixing in thermocline thermal energy storage, Int.J Heat Mass Transfer, Vol. 34, pp. 115-125 https://doi.org/10.1016/0017-9310(91)90179-I
  5. Musser, A. and Bahnfleth, W. P., 1998, Evolution of temperature distributions in a fullscale stratified chilled-water storage tank with radial diffusers, ASHRAE Transactions:Research, Vol. 104, pp.55-67
  6. Musser, A. and Bahnfleth, W. P., 2001, Parametric study of charging inlet diffuser performance in stratified chilled water storage tanks with radial diffusers: Part 1- Model development and validation, ASHRAE Transactions:Research, Vol. 107, pp.22-40
  7. Yoo, H. and Pak, E. T., 1995, Analytical solutions to a one-dimensional model for stratified thermal storage tanks, Korean J.of Air-Conditioning and Refrigeration Engineering,Vol. 7, No.1, pp.42-51
  8. Chung, J. D., Park, J. and Cho, S. H., 2004,Effect of diffuser shape on the performance of water-chilled heat storage, Korean J. of Air-Conditioning and Refrigeration Engineering,Vol. 16, No.4, pp.374-382
  9. Park, S. H., 1996, Robust Design and Analysis for Quality Engineering, Chapman &Hall, London, UK
  10. Cho, S. H., Tae, C. S., lang, C. Y, Lee, C. K,Yang, S. H. and Kang, H. K, 2003, Experimental study on stratification according to diffuser shape in the rectangular thermal storage tank, Proc. of the SAREK '03 Summar Annual Conference, pp.20-24