Thermal Comfort Condition of Temperature and Humidity in Loess Interior Space

  • Kong, Sung-Hoon
    • 대한의생명과학회지
    • /
    • 제10권2호
    • /
    • pp.129-135
    • /
    • 2004
  • The study was carried out through measuring the temperature and humidity of the indoor/outdoor space and the distribution of interior thermal condition, and investigating the effect of loess materials on human body. The purpose of this study is to analyze the change of dry bulb temperature and relative humidity and correlation of thermal reaction of human body with ASHRAE (American Society of Heating, Refrigerating and Air-conditioning) comfort chart in the loess interior space. In the view point of biomedical sciences, loess interior space provides optimum thermal conditions for human thermal sensation.

  • PDF

인간 열환경 지수(HumanThermal Sensation)를 이용한 조경계획 및 디자인 방법 (Landscape Planning and Design Methods with Human Thermal Sensation)

  • 박수국
    • 한국조경학회지
    • /
    • 제40권1호
    • /
    • pp.1-11
    • /
    • 2012
  • 이 연구는 인간 에너지 균형 모델에서 출발한 인간 열환경 지수 분석 방법을 이용하여 캐나다 BC주에 있는 나나이모시 상업지구안 좁은 길과 경상남도 창원시 중심상업지구에 있는 소공원을 연구 대상지로 2009년 여름철 열환경을 분석한 것이다. 기후 입력 자료는 기온, 상대습도, 풍속, 태양 및 지구 복사에너지이었으며, 그 결과 인간 열환경 지수에 가장 크게 영향을 미치는 요소들은 태양 직사광선, 건물시계지수 그리고 풍속이었다. 음지는 약간 더운 정도의 열환경을 조성하는 것으로 나타나 매우 덥게 나타난 양지에 비해 훨씬 좋은 열환경을 조성하는 것으로 나타났다. 나나이모 연구 대상지에 있는 좁은 길들은 주변의 넓은 장소들에 비해 주변 건축물에서 나오는 태양 반사광선과 지구 복사에너지들이 더 많이 영향을 미쳐 훨씬 덥게 나타났다. 낮은 풍속에 의해서 인체에서 방출되는 현열과 잠열의 양이 현저히 줄어듦으로서 더 더운 열환경이 조성되는 것으로 나타났다. 기후요소를 조경에 접목하기 위해서, 인간 열환경 지수 분석 방법을 이용하는 것은 열환경적으로 쾌적한 옥외 공간조성에 영향을 미칠 것이며, 도시 열섬 완화와 기후변화 연구에도 잘 이용될 수 있을 것이다.

바닥난방시 바닥 접촉면에 의한 한국인과 일본인의 온열감 반응에 대한 비교 연구 (A Study on the Influence Affect of Thermal Sensation in Korean and Japanes to Sit Directly on a Heated Floor)

  • 최영식
    • 한국산업융합학회 논문집
    • /
    • 제5권1호
    • /
    • pp.81-89
    • /
    • 2002
  • The objective of this paper is to clarify the combined effect of heat conduction, air temperature and thermal radiation on the person seated on the floor under operation of floor heating system. Experiments were conducted for summer seasons under 8 kinds of condition: combinations of air temperature $20^{\circ}C$, $22.5^{\circ}C$ and floor temperature $20^{\circ}C$, $22.5^{\circ}C$, $30^{\circ}C$, $35^{\circ}C$ and $40^{\circ}C$ under still air. Japanese and Koreans were adopted as subjects. To evaluate the effect of conduction operative temperature modified by heat conduction was derived from the human heat balance equation. New weighting coefficients were estimated from the modified operative temperature and modified mean skin temperature. As for thermal sensation the modified operative temperature more significantly correlated to that sensation each heat transfer processes. As the floor temperature is higher, the human conduction heat gain from floor increase and the dry heat from the human body decrease.

  • PDF

에어컨 장시간 운전시 온열쾌적감 평가에 관한 연구 (The Analysis for Thermal Comfort Evaluation during long time operating Air Conditioner)

  • 김동규;박종일;김세환
    • KIEAE Journal
    • /
    • 제7권5호
    • /
    • pp.59-64
    • /
    • 2007
  • Using air conditioner has been increased in home or office buildings in summer. Also various problems related to air conditioning such as disease induction happened by using air conditioner excessively and operating long. Active operation control is needed for occupant's health when air conditioner operates long. We should think ahead to acquire thermal comfort of occupants which represents psychological and physiological reaction for this operation. Research has been progressed to observe activity of autonomic nervous system by trying to quantitate change of thermal comfort. In this study, questions of the subject and change of body's autonomic nervous system were chosen to evaluate thermal comfort during operation of air conditioner for a long time. Electrocardiogram and questions of the subject which is the progress of changing TSV and CSV by occupants indoor were measured when room air conditioner is operated for a long time, and an air-conditioned adaptability of human body was evaluated by acquiring the change rate of autonomic nervous system through analyzing HRV. As a result of the evaluation, change rate of body's autonomic nervous system corresponded to votes of the subject's question generally, but was distinguished from analysis result of warm-cold sensation in a low temperature area.

재실자의 평균피부온(平均皮膚溫)에 관한 연구 (A Study on the Mean Skin Temperature of the Man Who Stay in the Room)

  • 최영식
    • 한국산업융합학회 논문집
    • /
    • 제3권4호
    • /
    • pp.307-317
    • /
    • 2000
  • The purpose of this study is to form a calculation formula of the mean skin temperature on the human body in a heated room by the use of floor heating system. Korean traditional floor heating system is a long way from being defunct. The floor heating systems based on hot water have been coming into wide use mainly in the apartment house. However, it is considered that the design process and evaluation method for the floor heating systems in the standpoint of human being are not established so far. In the floor heating systems, air temperature as well as floor temperature should be considered as physical factors which affect the sensation of human body. Furthermore, extremely few studies have been performed on the sitting with legs crossed posture sedentary which is the typical dwelling life style of residents from the ancient times in Korea, while a large number of studies on the influence of the floor heating systems on the human body in standing and sitting on a chair sedentary have been carried out. Especially, it is essential to elucidate how mean skin temperature on the human body is affected by thermal conduction in the contact area between the sitting with legs crossed posture sedentary human body and floor including thermal radiation due to the combination of air temperature and floor temperature, but the studies dealt with such issues have hardly been performed. Based on the above statements, the influence of the environment condition due to the combination of air temperature and floor temperature is discussed in the present investigation through theoretical of mean skin temperature on the human body in the floor heating systems.

  • PDF

사무실 근무자의 온열환경에 대한 적응수준 진단 (Diagnosis of Office Occupant's Adaptation Level for Thermal Environment)

  • 김양원
    • 한국생활과학회지
    • /
    • 제12권5호
    • /
    • pp.747-754
    • /
    • 2003
  • The actual clothing conditions were surveyed to diagnose clothing condition of Korean female in the view point of the adaptation to the thermal environment according to seasonal changes. Then, clothing microclimate, physiological responses, and subjective sensation were investigated through wearing trials on human body in climatic chamber based on the results from the survey. Factors to evaluate validity of clothing condition were clothing weight, clothing microclimate, physiological response of human body, and subjective sensation. The results were as follows: 1. Clothing weight per body surface area of the season was $856g/m^{2}$, $439g/m^{2}$ in summer, $630g/m^{2}$ in fall, and $1184g/m^{2}$ in winter. Cold - resistance of Korean female in office was superior to Japanese, inferior to residents of rural areas of Korea, and similar to male in office. However, in heat - resistance, female in office was inferior to residents of rural areas of Korea. 2. In spring, fall, winter, clothing microclimate temperature was a little higher than that in summer. Therefore, it was not a desirable wearing condition even though the clothing microclimate was comfortable zone. 3. Mean skin temperature of female in office was including within the range of Winslow's comfortable zone, but the range of comfortable zone in mean skin temperature of female was more narrow than Winslow's. Thus, it has problem for female to adaptation to thermal environment.

  • PDF

에어컨 온도변동에 따른 생리신호 변화에 관한 연구 (A Study of Physiology Signal Change by Air Conditioner Temperature Change)

  • 금종수;김동규;김형철
    • 수산해양교육연구
    • /
    • 제19권3호
    • /
    • pp.502-509
    • /
    • 2007
  • This study evaluates thermal comfort by air conditioner temperature raising at the point of time that human body begins to adapt. Thermal comfort according to change of time enters by uncomfortable area gradually at general cold room temperature that magnetic pole is in human body. However, can know that keep continuous thermal comfort in case raise temperature in human body adaptation visual point. Experiments were performed in environmental chamber. Subjects were selected 4 men and 4 women whose life cycle were proved that are similar. The subjects stay in the pretesting room during the 30 minutes and enter the testing room under each experiment conditions. During the experiment, brain wave, electrocardiogram, blood pressure and thermal comfort and sensation responses were measured. In this study, physiological and psychological responses correspond under temperature raising at human body adaptation.

온돌환경이 수면시의 생리반응에 미치는 영향 (제4보) (Effect of Ondol on Physiological Responses during Sleeping (IV))

  • 이순원;권수애
    • 한국생활과학회지
    • /
    • 제7권1호
    • /
    • pp.183-195
    • /
    • 1998
  • The purpose of this study is to investigate the effect of Ondol on the bedclimate, microclimate and physiological responses of occupants. Four healthy female subjects slept for seven hours in thermal environment of detached house and apartment respectively. Their bedclimate, microclimate, skin temperature, weight loss of body, weight of bedcloth and sleepwear, body movement and subjective sensation were measureed for this study. The results were as follows; The differences of bedclimate, microclimate, skin temperature were significant according to season and residence styles. The occupants of the detached house showed higher temperature and humidity inside quilt and clothes than those of the apartment did on apartment environment. The occupants of the detached house showed higher weight losses of body, heavier weights of quilt than those of the apartment did on apartment environment in the spring, autumn and winter, lower weight losses of mattress in the autumn and winter. The occupants of the detached house moved more than those of the apartment on apartment environment when sleeping. The occupants of the detached house felt higher thermal sensation and lower humidity sensation than those of the apartment did. The occupants of the detached house felt more comfortable than those of the apartment on detached house environment, while the occupants of the apartment felt more comfortable than those of the detached house on apartment environment. The thermal environments of the apartment and the detached house had an effect on the bedclimates, microclimates of occupants and therefore the physiological responses such as skin temperature, rectal temperature, weight loss of body, perspiration and subjective sensation are different during sleeping according to their residential styles on the same environment.

  • PDF

동계 인공환경실험에 의한 온열쾌적특성 연구 (A study on characteristics of thermal comfort for artificial environmental experiment in winter)

  • 박종일;김경훈;정성일
    • 설비공학논문집
    • /
    • 제10권6호
    • /
    • pp.721-731
    • /
    • 1998
  • Recently, many researchers are studying the relation between thermal environment and human comfort. The purpose of this study was to obtain basic data which are necessary to determine the thermal comfort sensation and physiological responses for men in winter indoor environment. From January to February 1998, subject experiment was 40 times proceeded under twenty different conditions of air temperature and relative humidity with early-twenty male university students. We examined subjective evaluation, Electrocardiogram(ECG), Electroencephalogram(EEG) of subjects. The results of this study can be summarized as follows : The comfort zone of people in winter was achieved at Standard new effective temperature($SET^*$) $ 25.2^{\circ}C$, PMV range was obtained by Fanger's statistical calculation was -0.27<PMV<+0.62, TSV range obtained subjects vote was -0.76<TSV<+0.36. The largest difference of skin temperature was found at the calf area as air temperature changes. vote rate of human body presented calflongrightarrowheadlongrightarrowforearmlongrightarrowchestlongrightarrowabdo men in turn. Heart rate was decreased at low $SET^*$ and heart rate was increased at high $SET^*$ But there was no change at EEG.

  • PDF

실내 난방시 온열쾌적성 평가에 관한 연구(part I;실내 난방시 실온변화에 따른 감성이미지 평가) (Experimental Study on Thermal Sensation Evaluation in Heating(part I: Emotion & Sensibility Image Evaluation by Indoor Temperature Change in Heating))

  • 한남규;금종수;김형철;김동규;김창연
    • 한국감성과학회:학술대회논문집
    • /
    • 한국감성과학회 2003년도 춘계학술대회 논문집
    • /
    • pp.41-46
    • /
    • 2003
  • In recently, Is inhabiting more than 70% indoors during a day in case of company employee and ordinary people which is looking at usual business. Therefore Thermal comfort of human body about indoor temperature and air flow acting very heftily. When intestine temperature is fallen for external low temperature and air flow in winter in case enter into heated room feel comfort by effect of temperature and feel comfort or discomfort by room heating condition gradually. Therefore it is important that grasp thermal comfort about temperature and air flow in heating to keep continuous comfort in indoor dwelling. Temperature and thermal comfort factor of emotion & sensitivity image exert fair effect since heating middle although thermal comfort change greatly effect on sensation about temperature at actuality heating early. Need much study yet in vantage point of emotion & sensitivity although much study were held about thermal and comfort sensibility and when heat in existing research until now. Therefore this study is targeting that evaluate thermal comfort through introduction of estimation method by emotion & sensibility image real and synthetic sensibility about thermal environment that is becoming winter heating.

  • PDF