• Title/Summary/Keyword: Thermal neutrons

Search Result 80, Processing Time 0.034 seconds

Design Review of A Power Converter Topology for CEDM Driving (CEDM 구동용 전력변환회로 설계 검토)

  • Lee, J.M.;Kim, C.K.;Cheon, J.M.;Park, M.K.;Kwon, S.M.
    • Proceedings of the KIEE Conference
    • /
    • 2006.07d
    • /
    • pp.1919-1920
    • /
    • 2006
  • This paper deals with the design review of a power converter topologies for CEDMCS (Control Element Drive Mechanism Control System). The CEDMCS provides the control signals and motive power to operate the CEDMS. The CEDM's raise and lower the CEAs (Control Element Assemblies) in the reactor core. The CEAs are constructed with the Boron-10 isotope which has a high microscopic cross section of absorption for thermal neutrons. This characteristic causes the addition of negative reactivity when a CEA is inserted and positive reactivity when it is withdrawn from the reactor core.

  • PDF

NEUTRON FIELD OF THE EARTH, ORIGIN AND DYNAMICS

  • Kuzhevskij, B.M.;Nechaev, O.Yu.;Panasyuk, M.I.;Sigaeva, E.A.;Volodichev, N.N.;Zakharov, V.A.
    • Journal of Radiation Protection and Research
    • /
    • v.26 no.3
    • /
    • pp.315-319
    • /
    • 2001
  • It is shown, that both cosmic radiation (external source) and natural radioactive gases (inner source) are sources of neutrons near the Earth crust. Correlation between the Earth crust dynamics and variations of thermal and slow neutron flux near the Earth surface is studied. It is shown, that variations of neutron flux near the Earth crust can be used for short-term predicting of natural hazards.

  • PDF

The Gamma-Ray Detection Circuit design of RI Use Instrument for Hand Carry (휴대용 RI 이용 계기의 감마선 검출 회로설계)

  • Seong, Nak-Jin;Kim, Sang-Jin;Kim, Ki-Joon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.05b
    • /
    • pp.154-158
    • /
    • 2003
  • In this study, to measure the density of compaction, it is designed to use the 5 gamma-ray detectors. The developed instrument consists of measuring circuits for gamma-rays and thermal neutrons, a high voltage supply unit, stable circuit unit, count circuit unit and a microprocessor. To read count pulse from gamma-ray detectors are very accurate and it can be count to data calibration excluded count of ripple.

  • PDF

Development of Power Control System for Nuclear Power Plants (원자로 출력제어계통 개발)

  • Lee, J.M.;Kim, C.K.;Cheon, J.M.;Kim, H.J.;Kweon, S.M.
    • Proceedings of the KIEE Conference
    • /
    • 2007.10a
    • /
    • pp.253-254
    • /
    • 2007
  • This paper deals with the development of power control system(PCS) for nuclear power plants. The PCS provides the control motive power to operate the CEDMs(Control Element Drive Mechanism) for reactivity control inside the reactor vessel. The CEDM is raise and lower the CEAs( Control Element Assemblies) inside the reactor core. The CEAs are constructed with the Boron-10 isotope which has a high microscopic cross section of absorption for thermal neutrons. This characteristic causes the addition of negative reactivity when a CEA is inserted and positive reactivity when it is withdrawn from the reactor core.

  • PDF

Design and Manufacturing of Power Cabinet for Reactor Power Control System (원자로 출력제어계통용 전력함 설계 및 제작)

  • Lee, J.M.;Kim, C.K.;Kim, S.J.;Cheon, J.M.;Kweon, S.M.;Nam, J.H.
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1626-1627
    • /
    • 2007
  • This paper deals with the design and manufacturing of power cabinet for reactor power control system(PCS). The PCS provides the control signals and motive power to operate the CEDMs(Control Element Drive Mechanism). The CEDM is raise and lower the CEAs(Control Element Assemblies) in the reactor core. The CEAs are constructed with the Boron-10 isotope which has a high microscopic cross section of absorption for thermal neutrons. This characteristic causes the addition of negative reactivity when a CEA is inserted and positive reactivity when it is withdrawn from the reactor core.

  • PDF

Development of evaluation of B/F benzothiazole analogues for boron neutron capture therapy

  • Ji-ung Yang;Soyeon Kim;Kyo Chul Lee;Yong Jin Lee;Jung Young Kim;Ji-Ae Park
    • Journal of Radiopharmaceuticals and Molecular Probes
    • /
    • v.8 no.1
    • /
    • pp.17-23
    • /
    • 2022
  • Boron neutron capture therapy is a precision treatment technology that selectively destroys only tumor cells by irradiating thermal neutrons after accumulating boron drugs in tumor cells. Brain tumor is difficult to diagnose and treat due to the low permeability and targeting of drugs caused by the blood-brain-barrier. Crossing the BBB is essential for drug delivery to the brain. In this study, we designed and synthesized a novel compound incorporating benzothiazole to develop a boron drug with high BBB permeability and selectivity for brain tumor cells. In addition, their potential as a BNCT drugs was evaluated.

The Characteristics for BNCT facility in Hanaro Reactor

  • Soheigh Suh;Lee, Dong-Han;Ji, Young-Hoon;Lee, Dong-Hoon;Yoo, Seong-Yul;Rhee, Chang-Hun;Rhee, Soo-Yong;Jun, Byung-Jin
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.161-163
    • /
    • 2002
  • The BNCT(Boron Neutron Capture Therapy) facility has been developed in Hanaro(High-flux Advanced Neutron Application Reactor), a research reactor of Korea Atomic Energy Research Institute. A typical tangenial beam port is utilized with this BNCT facility. Thermal neutrons can be penetrated within the limits of the possible maximum instead of being filtered fast neutrons and gamma rays as much as possible using the silicon and bismuth single crystals. In addition to, the liquid nitrogen (LN$_2$) is used to cool down the silicon and bismuth single crystals for the increase of the penetrated thermal neutron flux. Neutron beams for BNCT are shielded using the water shutter. The water shutter was designed and manufactured not to interfere with any other subsystem of Hanaro when the BNCT facility is operated. Also, it is replaced with conventional beam port plug in order to cut off helium gas leakage in the beam port. A circular collimator, composed of $\^$6/Li$_2$CO$_3$ and polyethylene compounds, is installed at the irradiation position. The measured neutron flux with 24 MW reactor power using the Au-198 activation analysis method is 8.3${\times}$10$\^$8/ n/cm$^2$ s at the collimator, exit point of neutron beams. Flatness of neutron beams is proven to ${\pm}$ 6.8% at 97 mm collimator. According to the result of acceptance tests of the water shutter, the filling time of water is about 190 seconds and drainage time of it is about 270 seconds. The radiation leakages in the irradiation room are analyzed to near the background level for neutron and 12 mSv/hr in the maximum for gamma by using BF$_3$ proportional counter and GM counter respectively. Therefore, it is verified that the neutron beams from BNCT facility in Hanaro will be enough to utilize for the purpose of clinical and pre-clinical experiment.

  • PDF

Target-Moderator-Reflector system for 10-30 MeV proton accelerator-driven compact thermal neutron source: Conceptual design and neutronic characterization

  • Jeon, Byoungil;Kim, Jongyul;Lee, Eunjoong;Moon, Myungkook;Cho, Sangjin;Cho, Gyuseong
    • Nuclear Engineering and Technology
    • /
    • v.52 no.3
    • /
    • pp.633-646
    • /
    • 2020
  • Imaging and scattering techniques using thermal neutrons allow to analyze complex specimens in scientific and industrial researches. Owing to this advantage, there have been a considerable demand for neutron facilities in the industrial sector. Among neutron sources, an accelerator driven compact neutron source is the only one that can satisfy the various requirements-construction budget, facility size, and required neutron flux-of industrial applications. In this paper, a target, moderator, and reflector (TMR) system for low-energy proton-accelerator driven compact thermal neutron source was designed via Monte Carlo simulations. For 10-30 MeV proton beams, the optimal conditions of the beryllium target were determined by considering the neutron yield and the blistering of the target. For a non-borated polyethylene moderator, the neutronic properties were verified based on its thickness. For a reflector, three candidates-light water, beryllium, and graphite-were considered as reflector materials, and the optimal conditions were identified. The results verified that the neutronic intensity varied in the order beryllium > light water > graphite, the compacter size in the order light water < beryllium < graphite and the shorter emission time in the order graphite < light water < beryllium. The performance of the designed TMR system was compared with that of existing facilities and were laid between performance of existing facilities.

AN EXPERIMENTAL STUDY ON THE MEASUREMENT OF MARGINAL LEAKAGE USING A NEUTRON ACTIVATION ANALYSIS (Neutron Activation Analysis를 이용한 Composite Resin의 변연누출 측정에 관한 실험적 연구)

  • Kim, Mi-Ja;Lee, Myung-Jong
    • Restorative Dentistry and Endodontics
    • /
    • v.13 no.1
    • /
    • pp.185-190
    • /
    • 1988
  • The study was designed to establish quantitative method for assessing the marginal leakage of dental restorations. 18 Class V cavities with $45^{\circ}$ bevel joint were prepared and replicas of these teeth were made with polyethylene wax. and classified with three groups. First group was filled with Scotch bond and silux. Second group was filled with glass ionomer cement:scotchbond/silux. Third group was filled with Dentin-Adhesit/Heliosit. After finishing, all specimens were subjected manually to 100 thermal cycles at $0^{\circ}C$ and $100^{\circ}C$ Samarium nitrate solution, irradiated with flux of $6{\times}12^{12}$ neutrons/$cm^2$/sec for 11 hours, woled for 200 hours, counted with the HpGe detector and the tracer uptake was determined by comparison with a standard of samarium ($10{\mu}g$). The following results were obtained. 1) The group filled with glass ionomer cement base showed least marginal leakage. 2) The group filled with Dentin-Adhesit/Heliosit showed less marginal leakage than the group filled with scotchbond/silux.

  • PDF

AN EXPERIMENTAL STUDY ON THE MEASUREMENT OF MARGINAL LEAKAGE USING A RADIOACTIVITY (충전후 방사능에 의한 변연누출 측정에 관한 실험적 연구)

  • Kim, Mi-Ja;Lee, Myung-Jong
    • Restorative Dentistry and Endodontics
    • /
    • v.13 no.1
    • /
    • pp.69-78
    • /
    • 1988
  • The study was designed to establish a more nearly quantitative method for assessing the marginal leakage of dental restorations. 27 Class V cavities with $45^{\circ}$ bevel joint were prepared and classified into 2 groups. One group was filled with Scotchbond and silux. The other group was filled with glass ionomer cement, Scotchbond and silux. After finishing, all specimens were subjected manually to 100 thermal cycles at $0^{\circ}C$ and $100^{\circ}C$ water-bath. They were soaked in a samarium nitrate solution for 3 hours, irradiated with flux of $6{\times}10^{12}$ neutrons/$cm^2$/sec for 11 hours, cooled for 200 hours, counted with the HPGE detector and the tracer uptake was determined by comparison with a standard of samarium (10 ${\mu}g$). The following results were obtained. 1. Both of the two groups showed a considerable amounts of marginal leakage. 2. The group filled without glass ionomer cement base showed more marginal leakage than the group filled with glass ionomer cement base. 3. Neutron Activation Analysis produced a good quantitative method to measure the marginal leakage and samarium was appropriate to measure the marginal leakage of resin restorations using neutron activation analysis.

  • PDF