• Title/Summary/Keyword: Thermal mitigation effect

Search Result 34, Processing Time 0.023 seconds

Effect of Cool Islands on the Thermal Mitigation in Urban Area -Case Study of Taegu Metropolitan City- (대도시에 있어 냉섬의 유형별 온도완화 효과 -대구광역시의 사례 연구-)

  • 박인환;장갑수;김종용;박종화;서동조
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.28 no.1
    • /
    • pp.11-18
    • /
    • 2000
  • Taegu is notorious as hot and dry summer among Korea cities. One of the most important goals of the open space planning is to ameliorate urban climate of the city. The objective of this research is to evaluate the thermal mitigation effect of the cool islands in Taegu metropolitan city. Cool islands of this paper includes parks and rivers surrounded by or adjacent to urbanized areas. Based on the analysis of the thermal band of Landsat TM at May 17, 1997, the thermal mitigation effect of open spaces in the city could be summarized as follows ; Kumho river showed the largest mitigation effect in terms of the width of mitigation zone and temperature difference. Evaporation from wide water surface and evapo-transpiration from riparian grass land could bring into results. Significant mitigation effect of parks covered with forest can be observed. The temperature range of such parks were between 19.05$^{\circ}C$ and 19.44$^{\circ}C$ However, the thermal mitigation effect of Dalsung park and Apsan park was insignificant. The small size and high percentage of hard paving of the former and the relative low density of the residential areas adjacent to the latter could be the main reason. In conclusion, the thermal mitigation effect in urban ope spaces could be detectedby the employment of thermal band data of Landsat TM and GIS buffering technique.

  • PDF

Performance Evaluation of Scale Mitigation Unit for Heat Exchangers (열교환기에 대한 스케일 완화장치의 성능평가)

  • Mo, Jeong-Ha;Sin, Sang-Cheol;Kim, Gyeong-U
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.9
    • /
    • pp.1149-1156
    • /
    • 2001
  • The objective of the present study is to investigate the performance of electronic scale mitigation unit(ESMU), which reduces the amount of scale in a heat exchanger. The circular tube with diameter of 19mm and plate-and-frame heat exchangers with 20 thermal plates were used for the tests. In order to accelerate the rate of scale in a laboratory test, artificial hard water of 1000ppm(as CaCO$_3$) was recirculated at a flow rate of 5 lpm, 7 lpm, and 9 lpm throughout the tests. The effect of ESMU on the scale thickness and overall heat transfer coefficients was examined. The test results showed that the ESMU could reduce the scale deposits even in the acceleated test.

Numerical Investigation of Surface Deformations in Resin Coated Quasi-Isotropic Laminates due to Thermal Variance (수지를 코팅한 준등방성 적층판에 대한 열변형 수치해석)

  • Kim, Kyung-Pyo
    • Korean Journal of Optics and Photonics
    • /
    • v.25 no.4
    • /
    • pp.207-215
    • /
    • 2014
  • In this paper the radial stiffness associated with stacking sequence effects, and the dimensional stability issue associated with thermally induced surface deformation in quasi-isotropic laminates due to the effect of stacking sequence and additional resin layer technique, are numerically investigated. Finally, the influence of surface resin layer techniques for fiber print-through mitigation in a composite mirror is tested for evaluation of surface accuracy across varying thermal conditions.

Impact of Urban Thermal Environment Improvement by Street Trees and Pavement Surface Albedo (가로수와 바닥 포장 표면 알베도의 도시 열 환경 개선 효과)

  • Na-youn Kim;Eun-sub Kim;Seok-hwan Yun;Zheng-gang Piao;Sang-hyuck Kim;Sang-jun Nam;Hwa-Jun Jea;Dong-kun Lee
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.26 no.1
    • /
    • pp.47-59
    • /
    • 2023
  • Due to climate change and urbanization, abnormally high temperatures and heat waves are expected to increase in urban and deteriorate thermal comfort. Planting of street trees and changing the albedo of urban surfaces are the strategies for mitigating the thermal environment of urban, and both of these strategies affect the exposure and blocking of radiative fluxes to pedestrians. After measuring the shortwave and longwave radiation according to the ground surface with different albedo and the presence of street trees using the CNR4 net radiometer, this study analyzed the relationship between this two strategies in terms of thermal environment mitigation by calculating the MRT(Mean Radiant Temperature) of each environment. As a result of comparing the difference between the downward shortwave radiation measured under the right tree and at the control, the shortwave radiation blocking effect of the tree increased as the downward shortwave radiation increased. During daytime hours (from 11 am to 3 pm), the MRT difference caused by the albedo difference(The albedo of the surfaces are 0.479 and 0.131, respectively.) on surfaces with no tree is approximately 3.58℃. When tree is present, the MRT difference caused by the albedo difference is approximately 0.49℃. In addition, in the case of the light-colored ground surface with high albedo, the surface temperature was low and the range of temperature change was lower than the surrounding surface with low albedo. This result shows that the urban thermal environment can be midigate through the planting of street trees, and that the ground surface with high albedo can be considered for short pedestrians. These results can be utilized in planning street and open space in urban by choosing surfaces with high albedo along with the shading effect of vegetation, considering the use by various users.

Analysis on the Mitigation Effects of Urban Heat Island through Creation of Water Space - A case study of Yeol-Mae village Apt in Daejeon's Noeun District - (수공간 조성을 통한 도시의 열섬현상 저감효과 분석 - 대전시 노은지구 열매마을아파트를 중심으로 -)

  • Park, Ki-Yong;Lee, Sun-Woo;Shim, Young-Ju;Hwang, Hee-Yun
    • KIEAE Journal
    • /
    • v.11 no.5
    • /
    • pp.13-18
    • /
    • 2011
  • The overall aim of this study is to mitigate urban environmental problems. In particular, to reduce the effects of urban heat island phenomenon which is one of the urban planning perspective. This study focused on the analysis of the relationship between the urban heat island effect and the thermal and wind properties. To do this analysis, water space was virtually made at Yeol_Mae village Apt. Because it is very difficult to set up water space for the existing apartment complexes due to realistic constraints. This study, therefore has a strong sort of guidelines to create water space for newly formed city. It was based on the concept of virtual city through an in-depth analysis on reduction of urban heat island effects for the existing apartment along with creation of water space. To analysis site, Envi-Met Model developed by Michael Bruse was used. The results are as follows. The temperature went from 298.9K to 297.82K and The wind speed went from 1.42m/s to 1.43m/s. The results are slight in this study because creation of water space is planned to a small area of an apartment complex. But if the water space would be applied to a whole city, the mitigation effect of urban heat island would be bigger.

Effect of ZnO Nanoparticle Presence on SCC Mitigation in Alloy 600 in a Simulated Pressurized Water Reactors Environment

  • Sung-Min Kim;Woon Young Lee;Sekown Oh;Sang-Yul Lee
    • Journal of the Korean institute of surface engineering
    • /
    • v.56 no.6
    • /
    • pp.401-411
    • /
    • 2023
  • This study investigates the synthesis, characterization, and application of zinc oxide (ZnO) nanoparticles for corrosion resistance and stress corrosion cracking (SCC) mitigation in high-temperature and high-pressure environments. The ZnO nanoparticles are synthesized using plasma discharge in water, resulting in rod-shaped particles with a hexagonal crystal structure. The ZnO nanoparticles are applied to Alloy 600 tubes in simulated nuclear power plant atmospheres to evaluate their effectiveness. X-ray diffraction and X-ray photoelectron spectroscopy analysis reveals the formation of thermodynamically stable ZnCr2O4and ZnFe2O4 spinel phases with a depth of approximately 35 nm on the surface after 240 hours of treatment. Stress corrosion cracking (SCC) mitigation experiments reveal that ZnO treatment enhances thermal and mechanical stability. The ZnO-treated specimens exhibit increased maximum temperature tolerance up to 310 ℃ and higher-pressure resistance up to 60 bar compared to non-treated ZnO samples. Measurements of crack length indicate reduced crack propagation in ZnO-treated specimens. The formation of thermodynamically stable Zn spinel structures on the surface of Alloy 600 and the subsequent improvements in surface properties contribute to the enhanced durability and performance of the material in challenging high-temperature and high-pressure environments. These findings have significant implications for the development of corrosion-resistant materials and the mitigation of stress corrosion cracking in various industries.

Thermal Management for Multi-core Processor and Prototyping Thermal-aware Task Scheduler (멀티 코어 프로세서의 온도관리를 위한 방안 연구 및 열-인식 태스크 스케줄링)

  • Choi, Jeong-Hwan
    • Journal of KIISE:Computer Systems and Theory
    • /
    • v.35 no.7
    • /
    • pp.354-360
    • /
    • 2008
  • Power-related issues have become important considerations in current generation microprocessor design. One of these issues is that of elevated on-chip temperatures. This has an adverse effect on cooling cost and, if not addressed suitably, on chip reliability. In this paper we investigate the general trade-offs between temporal and spatial hot spot mitigation schemes and thermal time constants, workload variations and microprocessor power distributions. By leveraging spatial and temporal heat slacks, our schemes enable lowering of on-chip unit temperatures by changing the workload in a timely manner with Operating System (OS) and existing hardware support.

Spatial Typification based on Heat Balance for Improving Thermal Environment in Seoul (열수지를 활용한 서울시 열환경 개선을 위한 공간 유형화)

  • Kwon, You Jin;Ahn, Saekyul;Lee, Dong Kun;Yoon, Eun Joo;Sung, Sunyong;Lee, Kiseung
    • Journal of Korea Planning Association
    • /
    • v.53 no.7
    • /
    • pp.109-126
    • /
    • 2018
  • The purpose of this study is to identify the spatial types for thermal environment improvement considering heat flux and its spatial context through empirical orthodox formulas. First, k-means clustering was used to classify values of three kinds of heat flux - latent, sensible and storage heat. Next, from the k-means clustering, we defined a type of thermal environment (type LHL) where improvement is needed for more comfortable and pleasant thermal environment in the city, among the eight types. Lastly, we compared and analyzed the characteristics of each classified thermal environmental types based on land cover types. From the study, we found that the ratio of impervious surfaces, roads, and buildings of the type LHL is higher than those of the type HLH (relatively thermal comfort environment). In order to improve the thermal environment, the following contents are proposed to urban planners and designers depending on the results of the study. a) Increase the green zone rate by 10% to reduce sensible heat; b) Reduce the percentage of impermeable surfaces and roads by 10% ; c) Latent heat increases when water and green spaces are expanded. This study will help to establish a minimum criterion for a land cover rate for the improvement of the urban thermal environment and a standard index for the thermal environmental improvement can be derived.

Risk Mitigation for Independent Power Producer Projects in Developing Countries Based on Case Studies (사례연구를 통한 개발도상국 민자발전사업 리스크 경감방안)

  • Yoon, Young-Il;Yoo, Ho-seon;Yeo, Yeong-Koo
    • Plant Journal
    • /
    • v.9 no.1
    • /
    • pp.50-57
    • /
    • 2013
  • This study investigates the risks that can occur during the development stage of IPP project in developing countries. In case that ECA and MLA cannot participate due to poor credit rating of the country, the diversification of power purchaser in marginal states can be a great help to reduce both market risk and country risk at the same time. In case of thermal power plants and combined cycle power plants, the effect of performance degradation as time passed will be considered and expected profit of sponsors should be maintained. Recently, developing countries are expanding IPP projects to reduce the financing cost and Korean power companies are positively participating in IPP projects. Accordingly, the loss of Korean companies should be minimized by risk management through the risk mitigation methods of this study.

  • PDF

Heat Mitigation Effects of Urban Space based on the Characteristics of Parks and their Surrounding Environment (도시공원 및 주변환경의 특성이 도시공간의 온도저감에 미치는 영향)

  • Suh, Jung-Eun;Oh, Kyu-Shik
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.23 no.5
    • /
    • pp.1-14
    • /
    • 2020
  • In order to improve the urban thermal environment, efforts are being made to increase green areas in cities that include park construction, planting, and green roofing. Among these efforts, urban parks play an important role not only in improving the urban thermal environment, but also in terms of ecosystem services (serving as resting places for citizens, providing cleaner air quality, reducing noise, etc.). Therefore, the purpose of this study is to suggest planning and management guidelines for urban parks that are effective in improving the thermal environment, by analyzing the urban surface temperature reduction performance of urban parks. To do this, first, land surface temperature was calculated by using Landsat 8 images. Second, the PCI (Park Cool Island) index was calculated to identify the temperature reduction performance of urban parks. Third, the characteristics of parks (area, shape, vegetation) and the surrounding spatial characteristics (land cover, building-related variables, etc.) were identified. Finally, the relationship between the PCI indices (PCI scale, PCI effect, PCI intensity) and the characteristics of the parks and their surroundings were analyzed. The results revealed that the parks consisting of a larger area, simple shape, and higher tree coverage ratio had increased PCI performance, and were advantageous for improving the urban thermal environment. Meanwhile, PCI performance was found to have decreased in areas with a higher impermeable area ratio and building coverage ratio. The outcomes of this study can be used to identify priority areas for planning and management of urban parks and can also be utilized as planning and management guidelines for improving urban thermal environment.