Characteristics of Electron Beam Extraction in Large Area Electron Beam Generator

  • Woo, Sung-Hun;Lee, Hong-Sik
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • 제4C권1호
    • /
    • pp.10-14
    • /
    • 2004
  • A large area electron beam generator has been developed for industrial applications, for example, waste water cleaning, flue gas treatment, and food pasteurization. The operational principle is based on the emission of secondary electrons from the cathode when ions in the plasma contact the cathode, which are accelerated toward the exit window by the gradient of the electric potential. Conventional electron beam generators require an electron beam scanning mechanism because a small area thermal electron emitter is used. The electron beam of the large area electron beam generator does not need to be scanned over target material because the beam area is considerable. We have fabricated a large area electron beam generator with peak energy of 200keV, and a beam diameter of 200mm. The electron beam current has been investigated as a function of accelerating voltage and distance from the extracting window while its radial distribution in front of the extracting window has been also measured.

장방형내 함수 다공성 물질의 동결거동에 관한 실험적 연구 (An Experimental study on the Freezing Phenomena of Saturated Porous Media in a Rectangular Cavity)

  • 김병철;김종일;김진흥
    • 설비공학논문집
    • /
    • 제3권5호
    • /
    • pp.386-394
    • /
    • 1991
  • Freezing of saturated porous media contained in a rectangular cavity has been studied experimentally. Water and different diameter glass beads consitituted the liquid and porous media. Solidification front shape, the effects of bead diameter and initial liquid temperature was investigated. When the hot wall temperature was below $4^{\circ}C$, the freezing rate was higher at the top than at the bottom due to the density inversion, but with increasing the hot wall temperature the freezing rate at the top was effected by the liquid temperature and was lower than at the bottom. With increasing the bead diameter, the difference of freezing rate between top and bottom was increased and depends on thermal conductivity. When the liquid temperature was low in the beginning, the freezing rate was high, but with increasing the time almost the same with those of high temperature liquid.

  • PDF

Numerical Analysis of Impurity Transport Along Magnetic Field Lines in Tokamak Scrape-011 Layer

  • Chung, Tae-Kyun;Hong, Sang-Hee
    • Nuclear Engineering and Technology
    • /
    • 제30권1호
    • /
    • pp.17-25
    • /
    • 1998
  • Transport of carbon and boron impurity ions parallel to magnetic field lines in the tokamak SOL (scrape-off layer) is numerically investigated for a one-dimensional steady state. The spatial distributions of density and velocity of the impurity ions in a steady state are calculated by finite difference method for a single-fluid model. The calculated results show that among forces acting on SOL particles thermal force produced tv plasma temperature gradient is a principal force determining the feature of impurity distribution profiles in the tokamak edge. However, strong collisional friction forces appearing dominant in front of the diverter plate restrain impurity ion flows due to temperature gradients from moving toward the midplane. Consequently, the stagnation point develops in the impurity flow by these two forces near the diverter region, in which ion flows change their directions. Impurity ions turn out to be accumulated at the stagnation points, where peaked profiles of highly-ionized state ions are relatively predominant over those of low-ionized state ions.

  • PDF

Screen printed contacts formation by rapid thermal annealing in multicrystalline silicon solar cells

  • Kim, Kyung hae;U. Gangopadhyay;Han, Chang-Soo;K. Chakrabarty;J. Yi
    • Journal of Korean Vacuum Science & Technology
    • /
    • 제6권3호
    • /
    • pp.120-125
    • /
    • 2002
  • The aim of the present work is to optimized the annealing parameter in both front and back screen printed contacts realization on p-type multicrystalline silicon and with phosphorus diffused. The RTA treatments were carried out at various temperatures from 600 to 850$\^{C}$ and annealing time ranging from 3 min to 5 min in air, O$_2$and N$_2$ ambiance. The contacts parameters are obtained according to Transmission Line Model measurements. A good RTA cycle is obtained with a temperature plateau of 700$\^{C}$-750$\^{C}$ and annealing ambiance of air. Several processing parameters required for good cell efficiency are discussed with an emphasis placed on the critical role of the glass frit in the aluminum paste. A anamolus behaviour of Aluminum n-doping on p-type Si wafer, contact at high temperature have also been studied.

  • PDF

실증실험용 저온 플라즈마 반응기의 유동특성에 관한 연구 (A Study on the Flow Characteristic of Non-Thermal Plasma Reactor for Demonstration)

  • 김유석;최석호;김정일;김태희;유정석;백민수;장길홍
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 추계학술대회논문집B
    • /
    • pp.508-513
    • /
    • 2000
  • HANJUNG has developed demonstration plant treating combustion flue gas such as dioxide($SO_2$) and nitrogen oxides(NOx). Before operating this system, we tested the inner airflow characteristic of demonstration plant in the front of plasma reactor field 1 and field 2. The experimental results of $25,000Nm^3/hr$ airflow are compared with the computational results using FLUENT code. It is found that the velocity distribution trends are matched the experimental results with the calculation results. To improve the eccentric airflow in the inlet hood, it is necessary to install the vertical guide vane as well as the horizontal guide vane.

  • PDF

가변 컨덕턴스 히트파이프의 열특성에 관한 해석 (Analysis on the Thermal Characteristics of Variable Conductance Heat Pipe)

  • 김근오;김무근;박병규
    • 설비공학논문집
    • /
    • 제13권1호
    • /
    • pp.38-47
    • /
    • 2001
  • The operation characteristics of variable conductance heat pipe(VCHP) were numerically investigated by using 1-dimensional diffuse-front model. For different boundary conditions, the amount of non-condensible gas charge and dimension of gas reservoir were obtained by iterative calculation. It is found that the amount of non-condensible gas charge and dimensions of gas reservoir have an effect on the temperature control of condenser for the given operating condition of VCHP. The numerical results show that VCHP has an excellent capability of temperature control when subjected to a change in the heat input.

  • PDF

발전소 변압기 소음저감 대책의 유효성 (The effectiveness of noise reduction devices for transformer noise control of Power Plants)

  • 김연환;김희수;배용채;이현;김성휘
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 춘계학술대회논문집
    • /
    • pp.1823-1828
    • /
    • 2000
  • Power transformers, air-intakes, stacks in a combined thermal power plant are the main noise sources. Power transformer noise among them has being get a target of public complaint due to 480Hz component of its pure tone. The source is mainly magnetostrictive vibration of the transformer core. The first countermeasures was installing sound barrier on the front of transformer. However, 500Hz, center of the frequency is not reduced. This paper includes the measurements of noise level at the near resident apartment, the identification of noise transfer and the countermeasures for noise sources. Cavity resonance type of noise reduction devices was installed on enclosuring wall of transformers. As a result, the noise level from transformer is reduced about 3dB.

  • PDF

엑사이머 레이저를 이용한 웨이퍼 크리닝에 관한 고찰 (The Study on Wafer Cleaning Using Excimer Laser)

  • 윤경구;김재구;이성국;최두선;신보성;황경현;정재경
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2000년도 춘계학술대회 논문집
    • /
    • pp.743-746
    • /
    • 2000
  • The removal of contaminants of silicon wafers has been investigated by various methods. Laser cleaning is the new dry cleaning technique to replace wafer wet cleaning in the near future. A dry laser cleaning uses inert gas jet to remove contaminant particles lifted off by the action of a KrF excimer laser. A laser cleaning model is developed to simulate the cleaning process and analyze the influence of contaminant particles and experimental parameters on laser cleaning efficiency. The model demonstrates that various types of submicrometer-sized particles from the front sides of silicon wafer can be efficiently removed by laser cleaning. The laser cleaning is explained by a particle adhesion model. including van der Waals forces and hydrogen bonding, and a particle removal model involving rapid thermal expansion of the substrate due to the thermoelastic effect. In addition, the experiment of wafer laser cleaning using KrF excimer laser was conducted to remove various contaminant particles.

  • PDF

Facile Fabrication of Aligned Doubly Open-ended TiO2 Nanotubes, via a Novel Selective Etching Process, and Thier Application in Dye Sensitized Solar Cells

  • 최종민;박태호
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2014년도 제46회 동계 정기학술대회 초록집
    • /
    • pp.483.2-483.2
    • /
    • 2014
  • In this study, we describe a simple selective etching method that produces noncurling, freestanding, large-area, aligned $TiO_2$ nanotube (NT) with doubly ends opened. The novel selective etching process only removed the thin 2nd bottom layer from the physically and chemically stable thick amorphous 1st top layer under thermal treatment at $250^{\circ}C$, yielding ordered doubly open-ended NT (DNT) that could be easily transferred to an FTO substrate for the fabrication of front-illuminated dye sensitized solar cells (DSCs). The DNT-DSCs yielded a higher PCE (8.6%) than was observed from $TiO_2$ nanoparticle (TNP)-based DSCs (7.3%), for comparable film thicknesses of $16{\mu}m$, despite of 20% decreased amount of dye. Intensity-modulated photocurrent and photovoltage spectroscopy (IMPS and IMVS, respectively) revealed that the DNT-DSCs exhibited electron lifetimes that were 10 times longer than those of TNP-DSCs, which contributed to high device performances.

  • PDF

On the Subtropical Countercurrent in the Western North Pacific

  • Chang, Sun-duck
    • 한국해양학회지
    • /
    • 제8권1호
    • /
    • pp.4-8
    • /
    • 1973
  • Recent dynamic computations of zonal flow and analysis of oceanographic data of CSK in winter indicate year-to year variations in the location and dynmic structure of the Subtropic Countercurrent in the western North Pacific. In January 1966, the Subtropical Countercurrent migrated southward to 21$^{\circ}$- 22$^{\circ}$N Lat in association with the subsurface Subtropical Convergence. At the area of 25$^{\circ}$- 26$^{\circ}$N Lat, another surface thermal front was formed along which a stronger eastward flow of approximately 0.4kt is seen. On the section of 142$^{\circ}$E Long in January 1967, eastward flow appears at every interval of 2$^{\circ}$latitude in the northern waters of 20$^{\circ}$N Lat.

  • PDF