• 제목/요약/키워드: Thermal environmental chamber

검색결과 111건 처리시간 0.026초

열환경챔버의 냉방 시뮬레이션 프로그램 개발에 관한 연구 (A Study on the Development of Cooling Simulation Program for Thermal Environmental Chamber)

  • 이한홍
    • 한국생산제조학회지
    • /
    • 제8권5호
    • /
    • pp.108-114
    • /
    • 1999
  • The thermal environmental chamber has been using in maintaining weather condition keeping thermal capacity under heating and cooling load fluctuation and for the performance testing of cooling system or air-conditioner on artificial envi-ronment. In ordder to make the various environmental conditions in the thermal environmental chamber the proper cooling system is necessary to eliminate the heating load produced inside the chamber and to maintain the designed environmental condition. For this reason the optimal design of cooling system and the prediction of performance is also required. This paper describes the prediction of performance of cooling system in the thermal environmental chamber with the capacity of 37,000kcal/hr which is developed for the test of performance in heating mode of heat pump system, In the results this paper is trying to develop simulation program on the base of mathematical models and which can be applied effectively to the optimal design of cooling system and prediction of performance to the inside and outside change of envi-ronmetal load.

  • PDF

인공위성 탑재품 수준 열진공 시험에 대한 열해석 모델의 개발과 환경시험 결과를 이용한 검증 (Development and Verification of Thermal Analysis Model for Thermal Vacuum Test of Satellite Components)

  • 김상호;서현석;유재호;한은수;김태경;김형동;허환일
    • 한국항공우주학회지
    • /
    • 제38권8호
    • /
    • pp.842-847
    • /
    • 2010
  • 본 연구는 인공위성 탑재품 열진공 시험시 적용된 열환경 조건, 탑재품 시험용 열진공 챔버의 형상, 위성체 내부의 열환경들을 고려하여 열진공 시험 과정을 모사하는 수치해석모델을 설계하여 열해석을 수행하였다. 피시험체인 탑재품과 열진공 챔버 구성요소의 시간에 따른 온도 변화를 보여주는 과도적(Transient) 해석 결과를 구할 수 있다. 열해석에 의한 성능향상 설계를 반영하여 업그레이드한 열진공 챔버를 이용한 탑재품 환경시험을 수행하였으며, 시험 결과와 열해석 결과에 대한 비교/검증을 수행하였다.

실내기후실험실 단축 실험을 위한 해석 기법 (An Analysis of Shortened Experiments for Environmental Chamber)

  • 최상현;배철호;정모;경남호;서항석
    • 설비공학논문집
    • /
    • 제12권4호
    • /
    • pp.404-413
    • /
    • 2000
  • Environmental chamber (EC) is an experimental facility used to analyze the characteristics of thermal response of testing objects by the artificial control of weather conditions. The EC in KIER can simulate the weather conditions by the control of temperature, humidity, and solar radiation. A two-storied testing building is located inside of EC. For the exact thermal response analysis of testing building, monthly or yearly scheduled operations are necessary. Although this long term operation gives the exact experimental data, it requires a high operational cost, long duration, and lots of manpower. Therefore it is necessary to perform the shortened experiments without sacrificing the validity of the obtained results. Since the characteristics of thermal response from the shortened experiments are different from the full time results, the analytical method to analyze the thermal response from the shortened experiments to estimate a full times results is developed in this study. The thermal response of testing building is performed using commercial software TRNSYS.

  • PDF

An Analysis of Shortened Experiments for Environmental Chamber

  • Choi, Sang-Hyun;Bai, Cheol-Ho;Chung, Mo;Kyung, Nam-Bo;Suh, Hang-Suk
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제9권3호
    • /
    • pp.18-26
    • /
    • 2001
  • Environmental chamber (EC) is an experimental facility used to analyze the characteristics of thermal response of testing objects by the artificial control of weather conditions. The EC in KIFR can simulate the weather conditions by the control of temperature, humidity, and solar radiation. A two-storied testing building is located inside EC. For the exact thermal response analysis of testing building, monthly or yearly scheduled operations are necessary. Although this long term operation gives the exact experimental data, it requires a high operational cost, long duration, and lots of manpower. Therefore it is necessary to perform the shortened experiments without sacrificing the validity of the obtained results. Since the characteristics of thermal response from the shortened experiments are different from the full time results, the analytical method to analyze the thermal response from the shortened experiments to estimate a full times results is developed in this study The thermal response of testing building is performed using commercial software TRNSYS.

  • PDF

열환경인공기후실의 설계 (Design of a Thermal Environmental Artifical Climate Chamber)

  • 고경태;정성일;박종일;김경훈
    • 한국섬유공학회:학술대회논문집
    • /
    • 한국섬유공학회 1998년도 봄 학술발표회 논문집
    • /
    • pp.285-290
    • /
    • 1998
  • The purpose of this study is the design of the climate chamber. Experiments was performed in a climate chamber that was running Under Floor Air-Conditioning System(UFAC). The chamber has a diffuser in the middle of the floor, and exhausts on the ceiling, simulating underfloor air conditioning system.

  • PDF

저공해 스토커형 도시폐기물 소각로 설계를 위한 열유동 수치해석 연구 (The Study of Numerical Simulation on the Thermal Flow Performance for the Design of Low Emission Stoker Type Municipal Waste Incinerator)

  • 전영남;송형운;김미환
    • 한국환경과학회지
    • /
    • 제11권6호
    • /
    • pp.543-551
    • /
    • 2002
  • A Numerical simulation on the thermal flow performance was carried out to propose the incinerator type for the domestic refuses and to investigate the design factor and operating conditions. The SSTI(Standard Stoker Type Incinerator) proposed in this study was modified from the type with central f)ow. It has the characteristics of good mixing between refuse and hot combustion gas in primary combustion chamber and between unburned gas inflowing and secondary air jet in secondary chamber. By predictive results, the SSTI was no recirculation zone in secondary chamber so that mixing time was increased with high residence time. It has good characteristics of combustion and low emission. Parametric screening studies have been understood with phenomenon of combustion in incinerator.

대형 열진공챔버용 극저온 모사장치 개발

  • 이상훈;조혁진;서희준;문귀원;최석원
    • 항공우주기술
    • /
    • 제3권1호
    • /
    • pp.103-108
    • /
    • 2004
  • 우주환경은 고진공 환경과 태양 복사열에 의한 고온 환경 및 극저온이 반복되는 가혹한 환경으로 특징지어 진다. 위성체는 지상에서 발사되어 우주궤도에 진입한 순간부터 가혹한 우주환경에 노출되어 위성체의 주요부품에 기능장애가 발생하여 결국 임무의 실패로 이어지기도 한다. 따라서 위성체는 지상에서 우주환경시험을 거쳐 기능 및 작동상태를 점검해야 한다. 한국항공우주연구원에서는 ∮3.6m×L3m 규모의 열진공챔버라 불리는 우주환경 모사장비를 보유ㆍ운용 중이나, 정지궤도 위성과 같은 대형 위성체의 시험을 위해 2005년 완공을 목표로 ∮8m×L10m급의 대형열진공챔버를 국산화 제작하고 있다. 통상 열진공챔버는 크게 진공계와 열제어계로 구분되어 질 수 있는데, 특히 열제어계에서 극저온 모사장치는 LN2를 쉬라우드 내부에 순환시킴으로서 -196℃의 극저온을 모사하는 시스템을 말한다. 본 논문에서는 국산화 대형열진공챔버의 열제어계에 적용할 극저온 모사장치의 개발 방안에 대하여 연구하였다.

  • PDF

소음이 실내 온열감과 온열쾌적감에 미치는 영향 (Effects of Noise on Indoor Thermal Sensation and Comfort)

  • 양원영
    • KIEAE Journal
    • /
    • 제17권1호
    • /
    • pp.83-89
    • /
    • 2017
  • Purpose: Thermal sensation or thermal comfort was randomly used in many studies which focused on combined effects of thermal and acoustic environments on human perception. However, thermal sensation and thermal comfort are not synonyms. Thermal comfort is more complex human perception on thermal environment than thermal sensation. This study aims to investigate effects of noise on thermal sensation and thermal comfort separately, and also to investigate effects of temperature on acoustic sensation and comfort. Method: Combined thermal and acoustic configurations were simulated in an indoor environmental chamber. Twenty four participants were exposed to two types of noise (fan and babble) with two noise levels (45 dBA and 60 dBA) for an hour in each thermal condition of PMV-1.53, 0.03, 1.53, 1.83, respectively. Temperature sensation, temperature preference, thermal comfort, noisiness, loudness, annoyance, acoustic comfort, indoor environmental comfort were evaluated in each combined environmental condition. Result: Noise did not affected thermal sensation, but thermal comfort significantly. Temperature had an effect on acoustic comfort significantly, but no effect on noisiness and loudness in overall data analysis. More explicit interactions between thermal condition and noise perception showed only with the noise level of 60 dBA. Impacts of both thermal comfort and acoustic comfort on the indoor environmental comfort were analyzed. In adverse thermal environments, thermal comfort had more impact than acoustic comfort on indoor environmental comfort, and in neutral thermal environments, acoustic comfort had more important than thermal comfort.

Application of a Turbojet Engine for Fire Extinguishing

  • Slitenko, A.F.;Kim, SooYong
    • International Journal of Aeronautical and Space Sciences
    • /
    • 제1권1호
    • /
    • pp.62-69
    • /
    • 2000
  • Present study deals with performance analysis of an inert gas generator (IGG) which can be used as effective means to suppress fire. The IGG uses a turbo-jet engine to generate inert gas for fire extinguishing. It is generally known that a less degree of oxygen content in the product of combustion will increase the effectiveness of fire extinguishing. An inert gas generator system with water injection has advantages of suffocating and cooling effects that are very important factors for fire extinguishing. Some aspects of influencing parameters, such as, air excess coefficient, compressor pressure ratio, air temperature before combustion chamber, gas temperature after combustion chamber, mass flow rate of water injection etc. on the performance of IGG system are investigated.

  • PDF

Using Natural Graphite Heat Spreaders to Increase CCFL LCD Operating Temperatures

  • Norley, Julian;Shives, Gary D.;Reis, Brad;Schober, John
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2007년도 7th International Meeting on Information Display 제7권1호
    • /
    • pp.273-276
    • /
    • 2007
  • A natural graphite heat spreader increased the upper operating temperature limit of a CCFL backlit LCD television. A 0-80W heat source was used to simulate additional electronics. Without the heat spreader, internal circuitry shut-down at ${\sim}30;$ no shut-down occurred above 80W with a heat spreader. Additionally, brightness, temperature uniformity, and operating ranges were improved, verified by environmental chamber performance testing at various ambient conditions.

  • PDF