• 제목/요약/키워드: Thermal coupled analysis

검색결과 469건 처리시간 0.029초

전력용 변압기의 온도상승 예측을 위한 전자계-열계 결합해석기법 연구 (A Study of Coupled Electromagnetic-Thermal Field Analysis for Temperature Rise Prediction of Power Transformer)

  • 안현모;김민수;송재성;한성진
    • 전기학회논문지
    • /
    • 제60권10호
    • /
    • pp.1838-1845
    • /
    • 2011
  • This paper deals with coupled electromagnetic-thermal field analysis for thermal fluid analysis of oil immersed power transformer. Electric power losses are calculated from electromagnetic field analysis and are used as input source of thermal field analysis based on computational fluid dynamics(CFD). Particularly, In order to accurately predict the temperature rise in oil immersed power transformer, the thermal problem should be coupled with the electromagnetic problem. Moreover, to reduce analysis region, the heat transfer coefficient is applied to boundary surface of the power transformer model. The coupling method results are compared with the experimental values for verifying the validity of the analysis. The predicted temperature rises show good agreements with the experimental values.

Heat Characteristics Analysis of Synchronous Reluctance Motor Using FEM Coupled Electromagnetic Field and Thermal Field

  • Lee, Jung-Ho;Jeon, Ah-Ram
    • Journal of Magnetics
    • /
    • 제15권3호
    • /
    • pp.138-142
    • /
    • 2010
  • This paper reports the development of an analysis method in a synchronous reluctance motor (SynRM) using the finite element method (FEM) coupled with the electromagnetic field of the Preisach model, which represents an additional thermal source due to hysteresis loss and a thermal field. This study focused on thermal analysis relative to hysteresis and copper losses in a SynRM.

열응력을 고려한 고무 오일시일 해석 (Coupled Thermal-Mechanical Analysis of Rubber Oil Seals)

  • 김청균;전인기
    • Tribology and Lubricants
    • /
    • 제10권2호
    • /
    • pp.39-42
    • /
    • 1994
  • This paper deals with the distributions of the contact stress in oil seals. The distributions of the contact stress due to the temperature effects are analyzed for various values of the interference for a nitrile rubber seal. The calculated FEM results show that the relative maximum stresses occur at the contacting area against the shaft, the flex zone, and the contacting area of the garter spring grooves. Using the coupled temperature-stress FEM a nalysis, the contact force of a radial lip seal with and without the garter spring are studied as a function of shaft diameter. The calculated results of mechanical analysis show good correspondence with those of the coupled thermal-mechanical analysis method except small values of the interference. And the calculated results indicated that the thermal stresses only have a very minor influence on the deformed shape of the lip seal as the interference increases. But the coupled temperature-stress analysis will be very useful tool to predict the contact behaviors of rubber lip seals for small values of the interference.

전동식 Scroll Compressor의 Scroll 열변형 해석 (Coupled Thermal-Stress Analysis of Scrolls in Automotive Scroll Compressor)

  • 이형욱;김정배;이근안;이종섭;이영선
    • 융복합기술연구소 논문집
    • /
    • 제2권1호
    • /
    • pp.38-42
    • /
    • 2012
  • A scroll compressor used in the air conditioning in automobile consists of the fixed scroll and the orbiting scroll. Temperature gradient in the scroll compressor during the operation induces the thermal expansion of two scrolls. Therefore, the gap between scrolls in the initial stage is regarded as an important variable in structural design of the scroll compressor. The coupled thermal-stress analysis was carried out for the scrolls of a scroll compressor. The temperatures of major points of two scrolls in the steady states were referred by the literature of C. Lin. The sequentially coupled thermal-stress analysis is utilized to the heat transfer analysis and the thermal expansion analysis. In the thermal expansion analysis, the contact analysis was considered between the fixed and the orbiting scrolls in order to obtain the penetration distance and the contact pressure between two scrolls. The range of deformation was from 44 to $76{\mu}m$ according to the height of the scroll. The maximum penetration distance of $60{\mu}m$ occurred at the top surface of the fixed scroll in the center of the scroll parts.

  • PDF

커빅 커플링을 적용한 밀-턴 스핀들의 열-구조 안정성 평가에 관한 해석적 연구 (An Analytical Study on the Thermal-Structure Stability Evaluation of Mill-Turn Spindle with Curvic Coupling)

  • 이춘만;정호인
    • 한국기계가공학회지
    • /
    • 제19권1호
    • /
    • pp.100-107
    • /
    • 2020
  • As demand for high value-added products with hard materials increases, the line center is used for producing high value-added products in many industries such as aerospace, automobile fields. The line center is a key device for smart factory automation that can improve the production efficiency and the productivity. Therefore, the development of a mill-turn line center is necessary to produce high value-added products with complex shapes flexibly. In the mill-turn process, a milling process and a turning process are combined. In particular, the turning process needs to increase the rigidity of the spindle. The purpose of this study is to analyze the thermal-structural stability through thermo-structural coupled analysis for a mill-turn spindle with a curvic coupling. The maximum temperature and thermal stability of the spindle were analyzed by thermal distribution. In addition, the thermal deformation and thermal-structural stability of the spindle were analyzed through thermo-structural coupled analysis.

사출금형의 열접촉 저항을 고려한 성형과정의 열-유동 연계해석 (Thermal-Fluid Coupled Analysis for Injection Molding Process by Considering Thermal Contact Resistance)

  • 손동휘;김경민;박근
    • 대한기계학회논문집A
    • /
    • 제35권12호
    • /
    • pp.1627-1633
    • /
    • 2011
  • 사출금형은 일반적으로 다수개의 부품을 조립하여 제작되며, 특히 성형부(Core/Cavity)가 금형 형판 내부에 조립되는 구조를 갖는다. 이러한 구조로 인해 금형 조립부 경계면에서는 열접촉 저항이 발생하여 금형 내부의 열전달 특성에 영향을 미치게 된다. 최근 금형의 열접촉 저항이 성형부의 온도분포에 미치는 영향을 수치적으로 예측하기 위한 선행연구가 수행되었으며, 본 연구에서는 이에 기반하여 열-유동 연계해석을 적용함으로써 금형 내부의 열접촉 저항이 사출성형시 유동특성에 미치는 영향을 분석 하였다. 상기 해석결과와 실험결과와의 비교분석을 통해 금형의 열접촉 저항을 고려한 열-유동 연계해석이 기존의 해석방법과 비교할 때 사출성형 유동특성을 보다 향상된 신뢰성으로 예측할 수 있음을 확인하였다.

고온.고압용 3-way 볼밸브의 특성해석 (A Characteristic Analysis of High Pressure and High Temperature 3-way Ball Valve)

  • 이준호
    • 한국기계가공학회지
    • /
    • 제11권4호
    • /
    • pp.180-184
    • /
    • 2012
  • 3-way ball valves have been mostly used for high temperature/high pressure valves using in petrochemical carriers and oil tankers, which requires high quality products with confidentiality and durability. As a larger disaster may be generated by leakage of oil or gas from valves, thus the present research applied a numerical analysis method with thermal-structural coupled field analysis and the performance test. The Max stress by parts was confirmed through thermal-structural coupled field analysis and develop the 3-way ball valve design, which is safe on operating condition. And its performance was verified by carrying out pressure test, leakage test and durability test for the manufactured 3-way ball valves with satisfying it's regulations.

CUPID 코드와 MARS 코드를 이용한 기기/계통 다중스케일 연계 해석 코드 구현 (COMPONENT AND SYSTEM MULTI-SCALE DIRECT-COUPLED CODE IMPLEMENTATION USING CUPID AND MARS CODES)

  • 박익규
    • 한국전산유체공학회지
    • /
    • 제21권3호
    • /
    • pp.89-97
    • /
    • 2016
  • In this study, direct code coupling, in which two codes share a single flow field, was conducted using 3-dimensional high resolution thermal hydraulics code, CUPID and 1-dimensional system analysis code, MARS. This approach provide the merit to use versatile capability of MARS for nuclear power plants and 3-dimensional T/H analysis capability of CUPID. Numerical Method to directly couple CUPID and MARS was described in this paper. The straight flow and manometer flow oscillation were calculated to verify conservation of coupled CUPID/MARS code in mass, momentum, and energy. This verification calculations indicates that the CUPID/MARS is coupled appropriately in numerical aspect and the coupled code can be applied to nuclear reactor thermal hydraulics after validation against integral transient experiments.

HOT CHANNEL ANALYSIS CAPABILITY OF THE BEST-ESTIMATE MULTI-DIMENSIONAL SYSTEM CODE, MARS 3.0

  • JEONG J.-J.;BAE S. W.;HWANG D. H.;LEE W. J.;CHUNG B. D.
    • Nuclear Engineering and Technology
    • /
    • 제37권5호
    • /
    • pp.469-478
    • /
    • 2005
  • The subchannel analysis capability of MARS, a multi-dimensional thermal-hydraulic system code, has been enhanced. In particular, the turbulent mixing and void drift models for the flow-mixing phenomena in rod bundles were improved. Then, the subchannel analysis feature was combined with the existing coupled system thermal-hydraulics (T/H) and 3D reactor kinetics calculation capability of MARS. These features allow for more realistic simulations of both the hot channel behavior and the global system T/H behavior. Using the coupled features of MARS, a coupled analysis of a main steam line break (MSLB) is carried out for demonstration purposes. The results of the calculations are very reasonable and promising.