• 제목/요약/키워드: Thermal connection

검색결과 186건 처리시간 0.028초

The Added Mass and Damping Coefficients of and the Excitation Forces on Four Axisymmetric Ocean Platforms

  • Kwang-June,Bai
    • 대한조선학회지
    • /
    • 제20권2호
    • /
    • pp.27-36
    • /
    • 1983
  • This paper presents numerical results of the added mass and damping coefficients of vertical axisymmetric bodies on or under the free surface. Also computed are the excitation forces on these bodies due to an incident regular wave system. The numerical scheme employs a localized finite-element method, which is based on the theory of the calculus of variations. The excitation forces and moments on a submerged half-spheroid lying on the bottom are computed and compared with the results obtained by others. he agreement is good. Several specific types of floating vertical axisymmetric platforms are considered for ten different wave lengths, in connection with the design of an ocean-thermal-energy converter platform. The added mass and damping coefficient, as well as the excitations, are presented. It is shown that simple strip theory gives a good approximation of the sway(and pitch) added mass for a disc platform having a long circular cylinder.

  • PDF

Transparency in Urban Environment

  • Leung, Luke;Zhu, Yue;Ray, Stephen D.;Jevtic, Adri
    • 국제초고층학회논문집
    • /
    • 제6권2호
    • /
    • pp.187-196
    • /
    • 2017
  • A generation of tall buildings has been dominated by International Style with full height glazing that is often vision glass. Large glass was intended to bring the outside in, to allow a connection to the natural environment, and to promote daylighting. Yet the glass box model of architecture is now under criticism due to expense to build, thermal and visual comfort issues for occupants, large carbon footprints, danger for birds, and aesthetic concerns with lack of transparency. This paper will take a fresh look at glass, transparency, energy consumption, and human health before offering alternative paths forward.

PLC Optical Splitter(1${\times}$32)의 신뢰성 평가 (High Reliability Optical Splitters Composed of Planar Lightwave Circuits)

  • 구현덕;임해용;박종혁;박강희
    • 한국광학회:학술대회논문집
    • /
    • 한국광학회 2008년도 하계학술발표회 논문집
    • /
    • pp.265-266
    • /
    • 2008
  • The environmental and mechanical reliability of planar lightwave circuit (PLC)-type optical splitter modules is investigated with references [1, 3]. The module is composed of Y-branching silica-based waveguides on Si connected to optical fiber with UV-curable adhesives and is packaged in a metal case which is filled with humidity-resistant resin. High optical performance such as low loss, low reflection, and thermal stability are obtained through the use of this fiber connection technique. Ten reliability tests including long-term environmental and mechanical and ALT test were carried out for more then ten $1{\times}32$ channel PLC splitter modules.

  • PDF

핀-관 열교환기에서 개별 열의 열전달 효과 (Heat Transfer Performance of Individual Rows in Fin-Tube Heat Exchangers)

  • 정지환;장근선;이현우
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2003년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.238-244
    • /
    • 2003
  • An experimental study was performed to examine the heat transfer performance of individual rows of fin-tube heat exchangers. The heat transfer performance was measured using air-enthalpy type calorimeter. The examined heat exchangers consists of $7{\Phi}$ tube and fin patterns of them are slit and louver types. Equivalent fin spacing are 18 FPI for all samples, and the number of tube rows were 2. In order to confirm that thermal boundary condition on fins of each row are the same, physically separated between two rows as well as connected heat exchangers were used. The frontal air velocity varied from 0.7 to 2.5 m/s. Heat transfer performance for each row are measured. It was observed that the heat transfer coefficient of the 2nd row were smaller than that of the 1st row at low Reynolds number while larger at high Reynolds number.

  • PDF

경보음 발생 및 자동Locking 장치형 전선압축기에 대한 연구 (The study Alarm & Auto Locking System of Electric Wire Compressor)

  • 최명호;이상호;김동명
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 B
    • /
    • pp.800-802
    • /
    • 2004
  • When an accident is happen due to using a bad Wire Compressor, some public resentments are caused and It cause lawsuit for we. In case, we will undergo a colossal financial loss. in addition to, Guide to improve quality of operation by using the number of times of pressing and pressing pressure with cooperative private enterprise. And because of needs for Thermal, Electrical and Chemical factor analysis of connection point of sleeve, expect to try improving problems of wire presser whole our company. We expect that reduce fault and save cost by this process. Consequently, we will prevent power losing and black out due to line faults by expulsion of inferiority equipment and prevent heating and line fault. This is possible using Alarming and Auto Locking Wire Compressor that is improve on this study.

  • PDF

지역 에너지 시스템의 계통 연계 및 독립 운전 특성에 관한 연구 (The Operating characteristics of Community Energy System(CES) with Grid connection and isolation)

  • 박용업;김광호;장성일
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.258-260
    • /
    • 2004
  • This paper analyse a operating characteristics when the Community Energy System (CES) is operated islanding mode. In the near future, CES might be one of major energy supply structures. The basic concept of CES is that it supplies electrical and thermal energy to the local customer loads through the islanded power network separated from the grid. The CES must be supplying local load with stable energy on the islanding mode, analysing necessary to thoroughly the operation feature. In order to show them, in this paper, we model the CES with 2.34 MVA DG and simulate the operating feature on the islanding mode of CES. The simulation results show that, in order to stability operate, the CES need the efficient load management and generation control schemes during the transition periods.

  • PDF

2열 핀-관 열 교환기의 열별 전열성능 측정 (Heat Transfer Performance of Individual Rows in Fin-Tube Heat Exchangers)

  • 권영철;정지환;장근선;홍기수;진심원
    • 설비공학논문집
    • /
    • 제16권3호
    • /
    • pp.280-286
    • /
    • 2004
  • An experimental study is peformed to examine the heat transfer performance of individual rows of fin-tube heat exchangers. The heat transfer performance is measured using an air-enthalpy type calorimeter. The examined heat exchangers consist of 7mm tube and fin patterns of them are slit and louver types. Equivalent fin spacings are 18 fins per inch(fpi) for all samples, and the number of tube rows are two. In order to confirm that thermal boundary condition on fins of each row are the same, physically separated between two rows as well as connected heat exchangers are used. The frontal air velocity is varied from 0.7 to 2.5㎧. Heat transfer performance for each row is measured. It is observed that the heat transfer coefficient of the second row is smaller than that of the first row at low Reynolds number while larger at high Reynolds number.

Reinforcing Performance of Networked Silicas in Silica-filled Chloroprene Rubber Compounds

  • Ryu, Changseok;Yang, Jae-Kyoung;Park, Wonhyeong;Kim, Sun Jung;Kim, Doil;Seo, Gon;Kim, Wook-Soo;Ahn, Ki Woong;Kim, Beak Hwan
    • Elastomers and Composites
    • /
    • 제54권1호
    • /
    • pp.40-53
    • /
    • 2019
  • The physical properties of chloroprene rubber (CR) compounds reinforced with networked silicas were investigated by comparing them to those reinforced with conventional silica to observe the effect of the organic connection bonds combining silica particles on their cure, tensile, and aging performance. The introduction of networked silica to CR increase in silica content to 80 phr in rubber, while the content of conventional silica was limited to 60 phr. The CR compounds reinforced with networked silica showed higher resistance to combustion. The gradual increases in delta torque, Mooney viscosity, and modulus of silica-filled CR compounds with silica content were mainly attributed to the specific interaction between the chlorine atoms of CR and the hydroxyl groups of silica. The CR compounds reinforced with networked silica showed low compression set and heat build-up and maintained their high modulus even after thermal, oil, and ozone aging.

확률론적 해석에 기반한 다중 열저장공동의 적정 이격거리 분석 (Analysis of the Optimal Separation Distance between Multiple Thermal Energy Storage (TES) Caverns Based on Probabilistic Analysis)

  • 박도현;김현우;박정욱;박의섭;선우춘
    • 터널과지하공간
    • /
    • 제24권2호
    • /
    • pp.155-165
    • /
    • 2014
  • 다중 열저장공동은 열에너지의 대규모 저장, 열적 성능 향상을 위한 높은 종횡비의 저장소 설계에 활용될 수 있다. 또한 긴 터널형의 단일공동이 열생산 및 주입을 위한 지상설비와의 연결에 적합하지 않은 경우, 길이를 줄인 다중 암반공동의 활용을 고려할 필요가 있다. 다중 열저장공동 활용시 공동간의 이격거리는 저장공간 설계시 고려해야 하는 주요 설계인자 중 하나이며, 정량적인 안정성 평가기준을 토대로 적정 이격거리가 산정되어야 한다. 본 논문에서는 대규모 열에너지 저장을 위한 다중 암반공동 계획시 공동간 이격거리를 결정하기 위한 수치 해석적 접근법에 대해 기술하였다. 다중 암반공동의 안정성 평가를 위해 기존의 결정론적 접근법과 달리 확률밀도에 의해 입력 매개변수의 불확실성을 정량적으로 고려할 수 있는 확률론적 해석기법을 이용하였으며, 집단열수 공급을 위한 다중 암반공동의 개념모델 설계에 적용하였다. 본 적용을 통해 확률론적 해석기법이 다중 암반공동의 이격거리 산정을 위한 의사결정 도구로서 유용하게 활용될 수 있음을 확인할 수 있었으며, 결정론적 해석결과와의 비교 분석으로부터 결정론적 접근법 적용시 안정성 평가기준을 신중히 설정할 필요가 있는 것으로 검토되었다.

폐기물 소각시설 굴뚝의 배기가스를 이용한 유기랭킨사이클 시스템의 열역학적 해석 (Thermodynamic Analysis on Organic Rankine Cycle Using Exhaust Gas of the Chimney in a Resource Recovery Facility)

  • 김선희;성태홍;김경천
    • 한국가스학회지
    • /
    • 제21권5호
    • /
    • pp.27-35
    • /
    • 2017
  • 폐기물 소각시설 굴뚝의 배기가스를 측정하여 활용 가능한 폐열의 양과 질을 확인한 바 그 양과 온도는 13.8kg/s, $176.6^{\circ}C$ 정도였다. 본 연구에서는 R-245fa를 작동유체로 하는 소각폐열회수 유기랭킨사이클(Organic Rankine Cycle: ORC) 발전시스템을 설계하고 다음과 같이 3가지 사례조건들을 시뮬레이션을 하였다. 기본 ORC 시스템에 따른 시뮬레이션에서는 출력과 총효율이 각각 96.56kW, 14.13% 임을 확인하였다. 과열기 추가에 따른 시뮬레이션에서는 작동유체 과열에 따른 엔탈피 증가로 0.09%의 출력상승을 얻을 수 있었으나, 작동유체의 감소로 16.58kW 만큼 적은 출력을 보였다. 그리고 공정열교환기 추가에 따른 시뮬레이션에서는 남은 배기가스의 열을 공정열수를 생산하여 총효율 38.51%까지 향상시켰다.