• 제목/요약/키워드: Thermal conductance

검색결과 119건 처리시간 0.022초

마이크로볼로미터 소자설계에 따른 적외선 검출특성 (Infrared Response Characterization on the Microbolometer Device Design)

  • 한명수;안수창;강태영;임성수
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 추계학술대회 논문집 Vol.21
    • /
    • pp.343-344
    • /
    • 2008
  • A surface micromachined uncooled microbolometer based on the amorphous silicon was designed, fabricated, and characterized. We designed the microbolometer with a pixel size of $44\times44{\mu}m^2$ and a fill factor of about 50 % ~ 70% by considering such important factors as the thermal conductance, thermal time constant, the temperature coefficient of resistance, and device resistance. Also, we successfully fabricated the microbolometer by using surface MEMS technology. Finally, we investigated responsivity and detectivity properties depends on the active area size.

  • PDF

CIC 초전도 도체의 안정성 (Stability of the Cable-in-Conduit Conductors)

  • 류경우
    • E2M - 전기 전자와 첨단 소재
    • /
    • 제10권9호
    • /
    • pp.895-900
    • /
    • 1997
  • A Quench in cable-in-conduit (CIC) conductors is often initiated by a disturbance such as strand motion that generates a highly localized normal zone in a strand or a few strands of the CIC conductors. The localized normal zone causes current and heat transfer between a disturbed strand and neighboring strands. Electrical and thermal contact characteristics between strands thus have an effect on the transient stability of the CIC conductors. In this paper the effect of contact characteristics between strands on the CIC conductor stability is presented based on the measured heat transfer characteristics of supercritical helium (SHe) for the local heating. The quench and recovery processes of the strands for the abrupt and highly localized disturbance are analyzed at the boundary between quench and recovery.

  • PDF

Microwave-assisted Synthesis of Mixed Ligand Complexes of Zn(II), Cd(II) and Hg(II) Derived from 4-aminopyridine and Nitrite Ion: Spectral, Thermal and Biological Investigations

  • Dhaveethu, Karuthakannan;Ramachandramoorthy, Thiagarajan;Thirunavukkarasu, Kandasamy
    • 대한화학회지
    • /
    • 제57권3호
    • /
    • pp.341-351
    • /
    • 2013
  • Zn(II), Cd(II) and Hg(II) complexes with a general composition[$M(L)_2(X)_2$], where L=4-aminopyridine (4AP) and $X=NO_2{^-}$ were prepared under microwave irradiation. The metal complexes were characterized by elemental analyses, molar conductance, IR, Far-IR, electronic, NMR ($^1H$, $^{13}C$), XPS spectral and thermal studies. The spectroscopic studies reveal the composition, different modes of bonding, electronic transition, different chemical environment of C and H atoms and the electronic state of the metal atoms. On the basis of the characterization data, tetrahedral geometry is suggested for all the complexes. The free ligand (4-aminopyridine) and their metal complexes were screened against phytopathogenic fungi and bacteria in vitro and the activities were compared.

Oxytocin produces thermal analgesia via vasopressin-1a receptor by modulating TRPV1 and potassium conductance in the dorsal root ganglion neurons

  • Han, Rafael Taeho;Kim, Han-Byul;Kim, Young-Beom;Choi, Kyungmin;Park, Gi Yeon;Lee, Pa Reum;Lee, JaeHee;Kim, Hye young;Park, Chul-Kyu;Kang, Youngnam;Oh, Seog Bae;Na, Heung Sik
    • The Korean Journal of Physiology and Pharmacology
    • /
    • 제22권2호
    • /
    • pp.173-182
    • /
    • 2018
  • Recent studies have provided several lines of evidence that peripheral administration of oxytocin induces analgesia in human and rodents. However, the exact underlying mechanism of analgesia still remains elusive. In the present study, we aimed to identify which receptor could mediate the analgesic effect of intraperitoneal injection of oxytocin and its cellular mechanisms in thermal pain behavior. We found that oxytocin-induced analgesia could be reversed by $d(CH_2)_5[Tyr(Me)^2,Dab^5]$ AVP, a vasopressin-1a (V1a) receptor antagonist, but not by $desGly-NH_2-d(CH_2)_5[D-Tyr^2,Thr^4]OVT$, an oxytocin receptor antagonist. Single cell RT-PCR analysis revealed that V1a receptor, compared to oxytocin, vasopressin-1b and vasopressin-2 receptors, was more profoundly expressed in dorsal root ganglion (DRG) neurons and the expression of V1a receptor was predominant in transient receptor potential vanilloid 1 (TRPV1)-expressing DRG neurons. Fura-2 based calcium imaging experiments showed that capsaicin-induced calcium transient was significantly inhibited by oxytocin and that such inhibition was reversed by V1a receptor antagonist. Additionally, whole cell patch clamp recording demonstrated that oxytocin significantly increased potassium conductance via V1a receptor in DRG neurons. Taken together, our findings suggest that analgesic effects produced by peripheral administration of oxytocin were attributable to the activation of V1a receptor, resulting in reduction of TRPV1 activity and enhancement of potassium conductance in DRG neurons.

축열조용 복합 다층 단열재의 단열 성능 연구 (A Study on the Insulation Performance of Composite Multilayer Insulation by Applciation of Heat Storage Tank)

  • 최규홍;황승식;신동훈;박우성;박대웅;손승길;정태용
    • 에너지공학
    • /
    • 제23권3호
    • /
    • pp.82-87
    • /
    • 2014
  • 적층 단열재(multi-layer insulation, MLI)는 초전도 마그넷과 초전도 전력 케이블과 같은 초전도 응용기기의 냉각에 사용되는 저온유지장치(cryostat)에 외부 열침입을 차단하여 단열성능을 향상시키기 위해 사용된다. 적층 단열재는 인공위성에 사용되는 단열재로 적층단열재를 구성하는 자재의 종류와 적층층수 등에 따라 단열 성능이 변화한다. 본 연구에서는 적층 단열재의 원리를 이용한 축열조용 복합 다층 단열재(composite multilayer insulation, CMI)의 구성 재질 종류를 변경하고 적층 방식을 바꿈으로서 단열 성능이 바뀌는 것을 확인하였다. 실험은 KS C 9805의 방법을 이용하였으며, 복합 다층 단열재의 단열 성능 확인을 위해 동일한 조건의 축열조에 스티로폼을 적용하여 비교하였다. 또한, 실험 결과를 분석하기 위한 방법으로 기존 단열재에 대한 등가 두께를 비교하고 type별 CMI의 열전도율을 구해 비교하였다. 그 결과 복합 다층 단열재의 등가 두께는 스티로폼 보다 작아 동일 두께인 경우 스티로폼 보다 단열성능이 더 우수함을 확인할 수 있었다. 또한, 복합 다층 단열재의 구성 소재 및 적층 방식에 따라 전도, 대류 및 복사와 관련된 값들의 변화가 총괄 열전달계수에 영향을 미치는 것을 확인할 수 있었다.

표면 습식 식각 및 열처리에 따른 GaN 단일 나노로드 소자의 전기적 특성변화 (The Electrical Properties of GaN Individual Nanorod Devices by Wet-etching of the Nanorod Surface and Annealing Treatment)

  • 지현진;최재완;김규태
    • 한국전기전자재료학회논문지
    • /
    • 제24권2호
    • /
    • pp.152-155
    • /
    • 2011
  • Even though nano-scale materials were very advantageous for various applications, there are still problems to be solved such as the stabilization of surface state and realization of low contact resistances between a semiconducting nanowire and electrodes in nano-electronics. It is well known that the effects of contacts barrier between nano-channel and metal electrodes were dominant in carrier transportation in individual nano-electronics. In this report, it was investigated the electrical properties of GaN nanorod devices after chemical etching and rapid thermal annealing for making good contacts. After KOH wet-etching of the contact area the devices showed better electrical performance compared with non-treated GaN individual devices but still didn't have linear voltage-current characteristics. The shape of voltage-current properties of GaN devices were improved remarkably after rapid thermal annealing as showing Ohmic behaviors with further bigger conductivities. Even though chemical etching of the nanorod surfaces could cause scattering of carriers, in here it was shown that the most important and dominant factor in carrier transport of nano-electronics was realization of low contact barrier between nano-channel and metal electrodes surely.

차량 내 탑승자 상태 인식용 적외선 센서의 제조 및 특성 (Fabrications and Characteristics of Infrared Sensor for Passenger Conditional Detection in Vehicle)

  • 이성현;남태운
    • 한국전기전자재료학회논문지
    • /
    • 제22권3호
    • /
    • pp.222-229
    • /
    • 2009
  • A noble infrared sensor was studied for passenger conditional detection in vehicle, This research relates to uncooled infrared sensors for detecting the presence, type and temperature of occupants in vehicle. It sense that the occupants purpose to control the smart airbag for safety in the case of adult or child and to control the automatic air conditioning for convenience. This paper described the design and the fabrication of microbolometers which were composed of 2 by 8 elements using the surface micromachining technology. The characteristics of the array were investigated in the spectral region of $8{\sim}12{\mu}m$. The fabricated detectors exhibited the thermal mass of $7.05{\times}10^{-9}\;J/K$, the thermal conductance of $1.03{\times}10^{-6}\;W/K$, the thermal time constant of 6.8 ms, the responsivity of $2.96{\times}10^4\;V/W$ and the detectivity of $1.01{\times}10^9\;cmHz^{1/2}/W$, at the chopper frequency of 10 Hz and the bias current of $4.4{\mu}A$. We could successfully detect the human body condition in the divided zone. As a results, we concluded that microbolometer optimized in this research could be useful for the application of passenger conditional detection in vehicle.

Temperature Dependent Behavior of Thermal and Electrical Contacts during Resistance Spot Welding

  • Kim, E.
    • International Journal of Korean Welding Society
    • /
    • 제2권1호
    • /
    • pp.1-10
    • /
    • 2002
  • The thermal contact conductance at different temperatures and with different electrode forces and zinc coating morphology was measured by monitoring the infrared emissions from the one dimensionally simulated contact heat transfer experiments. The contact heat transfer coefficients were presented as a function of the harmonic mean temperature of the two contacting surfaces. Using these contact heat transfer coefficients and experimentally measured temperature profiles, the electrical contact resistivities both for the faying interface and electrode-workpiece interface were deduced from the numerical analyses of the one dimension simulation welding. It was found that the average value of the contact heat transfer coefficients for the material with zinc coating (coating weight from 0 g/$mm^2$to 100 g/$mm^2$) ranges from 0.05 W/$mm^2$$^{\circ}C$ to 2.0 W/$mm^2$$^{\circ}C$ in the temperature range above 5$0^{\circ}C$ harmonic mean temperature of the two contacting surfaces. The electrical contact resistivity deduced from the one dimension simulation welding and numerical analyses showed that the ratio of electrical contact resistivity at the laying interface to the electrical contact resistivity at the electrode interface is smaller than one far both bare steel and zinc coated steel.

  • PDF

Spectroscopic, Thermal and Biological Studies of Zn(II), Cd(II) and Hg(II) Complexes Derived from 3-Aminopyridine and Nitrite Ion

  • Dhaveethu, Karuthakannan;Ramachandramoorthy, Thiagarajan;Thirunavukkarasu, Kandasamy
    • 대한화학회지
    • /
    • 제57권6호
    • /
    • pp.712-720
    • /
    • 2013
  • Microwave assisted syntheses of Zn(II), Cd(II) and Hg(II) complexes with 3-aminopyridine (3AP) and nitrite ($NO_2{^-}$) ions have been reported. The metal complexes were characterized by elemental analyses, molar conductance, IR, Far-IR, electronic, NMR ($^1H$, $^{13}C$), thermal and electron impact mass spectral studies. The spectroscopic studies reveal the composition, the nature of nitrite ligand in the complexes, electronic transitions, chemical environments of C and H atoms thermal degradation of the complexes. On the basis of characterization data, distorted tetrahedral geometry is suggested for Zn(II), Cd(II) and Hg(II) complexes. The organic ligand (3AP) and their metal complexes were screened against gram negative pathogenic bacteria and fungi in vitro. The results are compared with our previous report J. Korean Chem. Soc. 2013, 57, 341 on 4-aminopyridine and nitrite ion complexes of the same metal ions.

λ/4 흡수층 구조를 갖는 NDIR 이산화탄소 가스센서용 적외선 센서의 제조 및 특성 (Fabrications and Characteristics of Infrared Sensor Composed of λ/4 Absorbing Structure for the Application of NDIR CO2 Gas Sensor)

  • 이성현;남태운
    • 한국전기전자재료학회논문지
    • /
    • 제21권11호
    • /
    • pp.1005-1009
    • /
    • 2008
  • A noble infrared $\lambda/4$ absorbing structure using metal reflector was studied for uncooled infrared sensors. This paper described the design and the fabrication of IR uncooled detectors which were composed of 21 by 21 elements using the surface micromachining technology. The characteristics of the array were investigated in the spectral region of 4.26 ${\mu}m$. The fabricated detectors exhibited the thermal mass of $9.75\times10^{-9}$ J/K, the thermal conductance of $1.31\times10^{-6}$ W/K, the thermal time constant of 7.4 ms, the responsivity of $1.07\times10^5$ V/W and the detectivity of $1.04\times10^9$ $cmHz^{1/2}/W$, at the chopper frequency of 10 Hz and the bias current of 9.22${\mu}A$. Finally the absorptance efficiency of $\lambda/4$ absorbing structure was about 23.2 % higher than that of absence absorbing structure.