원전 케이블용 절연재료의 열분석과 등가수명 (Thermal Analysis and Equivalent Lifetime Prediction of Insulation Material for Nuclear Power Cable)

  • 김지연;양종석;박경흠;성백용;방정환;박대희
    • 한국전기전자재료학회논문지
    • /
    • 제29권1호
    • /
    • pp.17-22
    • /
    • 2016
  • The activation energy of a material is an important factor that significantly affects the lifetime and can be used to develop a degradation model. In this study, a thermal analysis was carried out to evaluate and collect quantitative data on the degradation of insulation materials like EPR and CSP used for nuclear power plant cables. The activation energy was determined from the relationship between log ${\beta}$ and 1/T based on the Flynn.Wall.Ozawa method, by a TGA test. The activation energy was also derived from the relationship between ln(t) and 1/T based on isothermal analysis, by an OIT test. The activation energy of EPR derived from thermal analysis was used to calculate the accelerated aging time corresponding to the number of years of use, employing the Arrhenius equation, and determine the elongation corresponding to the accelerated aging time.

전력용 변압기의 열화에 의해 생성된 부산물의 분석 (Analysis of Produced By-products Due to Oil/Paper Degradation on Power Transformers)

  • 김재훈;한상옥
    • 전기학회논문지
    • /
    • 제56권9호
    • /
    • pp.1561-1565
    • /
    • 2007
  • According to thermal degradation on power transformers, it is known that electrical, mechanical and chemical characteristics for power transformer's oil-paper are changed. In the chemical property, especially, when the kraft paper is aged, the cellulose polymer chains break down into shorter lengths. It causes decrease in both tensile strength and degree of polymerization of paper insulation. Also the paper breakdown is accompanied by an increase in the content of various furanic compounds within the dielectric liquid. It is known that furanic components in transformer oil come only from the decomposition of insulating paper rather than from the oil itself. Therefore the analysis of furanic degradation products provides a complementary technique to dissolved gas analysis for monitoring transformers when we evaluate the aging of insulating paper by the total concentration of carbon monoxide and carbon dioxide dissolved in oil only. Recently, the analysis of furanic compounds by high performance liquid chromatography(HPLC) using IEC 61198 method for estimating degradation of paper insulation in power transformers has been used more conveniently for assessment of oil-paper. It is know that the main products which is produced by aging are 2-furfuryl alcohol, 2-furaldehyde(furfural), 2-furoic acid, 2-acetylfuran, 5-methyl-2-furaldehyde, and 5-hydroxymethyl-2-furaldehyde. For investigating the accelerated aging process of oil-paper samples we manufactured accelerating aging equipment and we estimated variation of insulations at $140^{\circ}C$ temp. during 500 hours. Typical transformer proportions of copper, silicon steel and iron have been added to oil-paper insulation during the aging process. The oil-paper insulation samples have been measured at intervals of 100 hours. Finally we have analyzed that 2-furoic acid and 2-acetylfuran products of furanic compounds were detected by HPLC, and their concentrations were increased with accelerated aging time.

전기철도용 견인전동기의 복합가속열화 상태진단에 관한 연구 (A Study on the Complex Accelerating Degradation and Condition Diagnosis of Traction Motor for Electric Railway)

  • 왕종배
    • 한국전기전자재료학회논문지
    • /
    • 제15권1호
    • /
    • pp.93-101
    • /
    • 2002
  • In this study, the stator form-winding sample coils based on silicone resin and polyimide were made for fault prediction and reliability estimation on the C-Class(200$\^{C}$ ) insulation system of traction motors. The complex accelerative degradation was periodically performed during 10 cycles, which was composed of thermal stress, fast rising surge voltage, vibration, water immersion and overvoltage applying. After aging of 10 cycles, the condition diagnosis test such as insulation resistance '||'&'||' polarization index, capacitance '||'&'||' dielectric loss and partial discharge properties were investigated in the temperature range of 20 ∼ 160$\^{C}$. Relationship among condition diagnosis tests was analyzed to find a dominative degradation factor and an insulation state at end-life point.

견인전동기의 복합가속열화 상태진단에 의한 고장예측 및 신뢰성 평가 (Fault Prediction & Reliability Estimation of the Traction Motor by the Complex Accelerating Degradation and Condition Diagnosis)

  • 왕종배;김명룡
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 하계학술대회 논문집
    • /
    • pp.763-766
    • /
    • 2000
  • In this paper, stator form-winding sample coils based on silicone resin and polyimide were made for fault prediction and reliability estimation on the 200 Class insulation system of traction motors. The complex accelerative degradation was performed by periods during 10 cycles, which was composed of thermal stress, fast rising surge voltage, vibration, water immersion and overvoltage applying. After aging of 10 cycles, condition diagnosis test such as insulation resistance & polarization index, capacitance & dielectric loss and partial discharge properties were investigated in the temperature range of 20∼160$^{\circ}C$. Relationship among condition diagnosis test was analyzed to find an dominative degradation factor and an insulation state at end-life point.

  • PDF

고온인가에 따른 에폭시 복합체의 열화 및 유전특성평가 (Estimation of Degradation and Dielectric Properties for Epoxy Composites doe to Applying High Temperature)

  • 왕종배;이준웅;김재환
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1995년도 추계학술대회 논문집
    • /
    • pp.175-178
    • /
    • 1995
  • Distribution of relaxation time is presented in the Cole-Cole arc diagram with frequency parameter. In the case of estimation of activation energy for main chains, maximum loss frequencies of ${\alpha}$ peaks, f$\sub$m/(${\alpha}$) display curved change according to the WLF type with variations of temperature. Structural change by the filling of filler and degradation by the thermal aging can be estimated from the WLF factors, C$_1$and C$_2$in Log f$\sub$m/-1/T curves which reflect the variations of free volume and thermal expansivity of composites.

  • PDF

주상변압기 절연유의 경년열화반응 속도론에 관한 연구 (A Study on the Age Degradation Kinetics of Pole Transformer Oil)

  • 남영우
    • 한국조명전기설비학회지:조명전기설비
    • /
    • 제11권1호
    • /
    • pp.99-105
    • /
    • 1997
  • 본 논문에서는 주상변압기 절연유의 가속열화반응을 수행하였다. 유중가스를 air bubbling 법으로 추출하여 가스크로마토크라프로 성분을 분석하였으며 가스농도는 각 가스의 추출율을 감안하여 보정하였다. 절연재료의 열화는 열분해반응과산화반응에의하여 진행되었으며 두 종류의 반응은 모두 0차반응의 특성을 보였고 탄화수소류, CO+{{{{ { CO}_{2 } }}}} 및 수소가스의 생성속도식을 얻었다. 유중가스 분석과 UV-Visible 분광광도법에 의하여 변압기내의 철심과 동코일이 열화과정에서 촉매역활을 함을 확인하였다.

  • PDF

알루미나 분말의 첨가에 따른 실리콘고무수지 함침 마이카시트의 특성 (Effects of Alumina Powder on the Properties of Mica Sheet Impregnated with Silicone Rubber Resin)

  • 박효열;강동필;안명상;명인혜
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제54권12호
    • /
    • pp.561-566
    • /
    • 2005
  • This paper describes electrical resistivity, dielectric strength, thermal conductivity, thermal stability and tensile strength of mica sheet impregnated with silicone rubber resin or silicone rubber resin containing alumina powder. The mica sheet impregnated with silicone rubber resin had higher electrical resistivity, dielectric strength and tensile strength than those of virgin mica sheet. Electrical resistivity of mica sheet impregnated with silicone rubber resin containing alumina increased with increasing the amount of alumina. However, dielectric strength and tensile strength of mica sheet impregnated with silicone rubber resin containing alumina decreased with increasing the amount of alumina. The mica sheet impregnated with silicone rubber resin had lower thermal conductivity than that of virgin mica sheet. However, thermal conductivity of mica sheet impregnated with silicone rubber resin conatining alumina increased with increasing the amount of alumina. In the case of thermal stability, thermal degradation of virgin mica sheet and impregnated mica sheet with silicone rubber resin did not occur up to $1100^{\circ}C$ and $400^{\circ}C$, respectively.

절연물의열화에 의한 변압기유의 가스분석 (Gas detection of transformer oil according to degradation characteristic of insulation material)

  • 황규현;서호준;이석우;이동희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2005년도 하계학술대회 논문집 Vol.6
    • /
    • pp.574-574
    • /
    • 2005
  • To found out the degradation characteristic of transformer insulation, insulation material was depisited into transformer oil and heated. Due to the thermal stress which added to insulation, the density of carbon dioxide which included in transformer oil was mesured by using the gas density detection equipment of gas sensor and air circulation method. As a result, it didn't match with the transformer supervision standard. But it was found that as thermal stress increased, the density of carbon dioxide propertionally increased.

  • PDF

복합열화에 의한 형권 고정자권선의 절연신뢰성에 관한 연구 (A Study on the Insulation Reliablity of Form-Wound Stator Windings by Complex Degradation)

  • 이헌돈;김상걸;오현석;왕종배;김기준;이준웅
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 하계학술대회 논문집
    • /
    • pp.152-155
    • /
    • 2000
  • PWM inverter-fed traction motor is able to occur problems by additive transient surge stress and harmonic loss in contrast with motor driven by 60Hz sine wave alternating source. Therefore in this paper, test method and standard of existed already were investigate, "thermal + electric" complex degradation test that considered additive degradation occurred by inverter drive carried out in order to obtain insulation reliability of traction motor driven by inverter. It seems that this test method confers large value of application at reliability estimation which the subject of complete motor not windings sample from now on.

  • PDF

Improvement of Degradation Characteristics in a Large, Racetrack-shaped 2G HTS Coil for MW-class Rotating Machines

  • Park, Heui Joo;Kim, Yeong-chun;Moon, Heejong;Park, Minwon;Yu, Inkeun
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권3호
    • /
    • pp.1166-1172
    • /
    • 2018
  • Degradation due to delamination occurs frequently in the high temperature superconductors (HTS) coil of rotating machines made with 2nd generation (2G) HTS wire, and the authors have observed other similar cases. Since an HTS field coil for a rotating machine is required to have stable current control and maintain a steady state, co-winding techniques for insulation material and epoxy resin for shape retention and heat transfer improvement are applied during coil fabrication. However, the most important limiting factor of this technique is delamination, which is known to be caused by the difference in thermal expansion between the epoxy resin and 2G HTS wire. Therefore, in this study, the experimental results of mixing the ratio of epoxy resin and alumina ($Al_2O3$) filler were applied to the fabrication of small and large test coils to solve the problem of degradation. For the verification of this scheme, eight prototypes of single pancake coils with different shapes were fabricated. They showed good results. The energization and operation maintenance tests of the stacked coils were carried out under liquid neon conditions similar to the operation temperature of an MW-class rotating machine. In conclusion, it was confirmed that the alumina powder mixed with epoxy resin in an appropriate ratio is an effective solution of de-lamination problem of 2G HTS coil.