• Title/Summary/Keyword: Thermal air treatment

Search Result 178, Processing Time 0.041 seconds

Thermal properties of the surface-modified Inconel 617 (표면 처리에 따른 Inconel 617 합금의 고온 특성)

  • Cho, Hyun;Bang, Kwang-Hyun;Lee, Byeong-Woo
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.19 no.6
    • /
    • pp.298-304
    • /
    • 2009
  • The effect of the surface treatments on the high temperature properties of the Inconel 617, one of the promising candidate alloys for high temperature heat-transport system, has been studied. Various surface modification methods including a rapid thermal process(RTP), a hydrothermal treatment, and a physical vapor deposition($2{\mu}m$ thick TiAlN film by an arc discharge) were applied to the Inconel 617. The morphological and the structural properties of the surface-modified Inconel 617 samples after heat treatment at $1000^{\circ}C$ in the air were compared to find out whether inhomogeneous formation of $Cr_2O_3$ crust at the surface region was suppressed or not. TiAlN-coated Inconel 617 showed homogeneous microstructure and the lowest wear loss compared to bare, RTP- and hydrothermally-treated Inconel 617 by suppressing the $Cr_2O_3$ crust formation.

Evaluation of shear bond strength of repair acrylic resin to Co-Cr alloy

  • Kulunk, Safak;Kulunk, Tolga;Sarac, Duygu;Cengiz, Seda;Baba, Seniha
    • The Journal of Advanced Prosthodontics
    • /
    • v.6 no.4
    • /
    • pp.272-277
    • /
    • 2014
  • PURPOSE. The purpose of this study was to investigate the impact of different surface treatment methods and thermal ageing on the bond strength of autopolymerizing acrylic resin to Co-Cr. MATERIALS AND METHODS. Co-Cr alloy specimens were divided into five groups according to the surface conditioning methods. C: No treatment; SP: flamed with the Silano-Pen device; K: airborne particle abrasion with $Al_2O_3$; Co: airborne particle abrasion with silica-coated $Al_2O_3$; KSP: flamed with the Silano-Pen device after the group K experimental protocol. Then, autopolymerized acrylic resin was applied to the treated specimen surfaces. All the groups were divided into two subgroups with the thermal cycle and water storage to determine the durability of the bond. The bond strength test was applied in an universal test machine and treated Co-Cr alloys were analyzed by scanning electron microscope (SEM). Two-way analysis of variance (ANOVA) was used to determine the significant differences among surface treatments and thermocycling. Their interactons were followed by a multiple comparison' test performed uing a post hoc Tukey HSD test (${\alpha}=.05$). RESULTS. Surface treatments significantly increased repair strengths of repair resin to Co-Cr alloy. The repair strengths of Group K, and Co significantly decreased after 6,000 cycles (P<.001). CONCLUSION. Thermocycling lead to a significant decrease in shear bond strength for air abrasion with silica-coated aluminum oxide particles. On the contrary, flaming with Silano-Pen did not cause a significant reduction in adhesion after thermocycling.

Characteristics of perovskite-structure Sr(Ti1-xFex)O3 thick film gas sensors (페롭스카이트 구조 Sr(Ti1-xFex)O3 후막 가스센서의 특성)

  • Jin, Guang-Hu;Lee, Woon-Young;Lee, Hyun-Gyu;Park, Jin-Seong
    • Journal of Sensor Science and Technology
    • /
    • v.18 no.6
    • /
    • pp.456-461
    • /
    • 2009
  • Perovskite-structure $Sr(Ti_{1-x}Fe_x)O_3$ thick films, in which x is 0.4 or 0.6, were prepared by normal ceramic process on alumina substrate. Electrical resistance was measured as a function of thermal treatment condition including atmosphere, time, and temperature. The resistance of $Sr(Ti_{1-x}Fe_x)O_3$ films is lower than those of $SrTiO_3$ or $SrFeO_3$ films. The temperature coefficient of resistance over $550^{\circ}C$ was measured to be 0 for the $Sr(Ti_{1-x}Fe_x)O_3$ films after thermal treatment at $1100^{\circ}C$ in air. The sensing property of the films was also measured as a function of temperature and gas such as $O_2$, CO, $CO_2$, NO and $NO_2$. $Sr(Ti_{1-x}Fe_x)O_3$ films showed a good sensing property for $O_2$, but no sensing signal for CO, $CO_2$, NO and $NO_2$.

Floor Heating Characteristics of Latent Heat Storage-Bioceramic Ondal - Focused on Historical research and Expermental Analysis - (잠열 축열-바이오 세라믹 온돌의 난방 특성 - 온돌의 역사적 고찰 및 실험적 분석을 중심으로 -)

  • Sone, Hyun-Kap;Ryon, Young-Sun
    • Solar Energy
    • /
    • v.15 no.1
    • /
    • pp.13-28
    • /
    • 1995
  • In this study, the history of Korean traditional Ondol was investigated and the latent heat materials and bioceramics were selected to develop the latent heat storage-bioceramics Ondol system based on the Korean traditional Ondol(sensible heat storage type), and the thermal characteristics of Ondol were analyzed experimentally The results could be summarized as follows; 1. Korean traditional Ondol has been originated in "Whaduk" which had been utilized continuously for about $2{\times}10^6$ years from the Old Stone Age to the Bronze Age, and Korean traditional Ondol using in these days has been utilized for about 976 years from the Koryu Dynasty to the Modern Ages. 2. $Na_2SO_4{\cdot}10H_2O(SSD)$ was selected as latent heat material for the latent heat storage Ondol. 3. Ondol unit was filled with the latent heat material of 0.63 kg and the dimension of Ondol unit was $400mm{\times}400mm{\times}27mm(width{\t\imes}depth{\times}height)$. 4. The comfortable surface temperature($23{\sim}29^{\circ}C$) of the latent heat storage Ondol was lasted 5 hours at the room temperature of $16{\sim}18^{\circ}C$, whereas that of sensible heat storage Ondol was lasted only 1.0 hours in the same conditions. 5. For the thermal effect of bioceramics, the Ondol air temperature i.n case of bioceramics treatment on the pannel was higher than that of without bioceramics treatment.

  • PDF

The Study of Waste Treatment using Advanced Oxygen Enriched Combustion System (산소부하 연소 시스템을 이용한 폐기물 열처리에 관한 연구)

  • Lee, Keon-Joo
    • 한국연소학회:학술대회논문집
    • /
    • 2003.05a
    • /
    • pp.231-239
    • /
    • 2003
  • In this study, the waste of landfill was treated using advanced enriched oxygen combustion system. The oxygen concentration of this study was 21%, 25%, 30% and 40% and the operating capacity was 200 g/min and the residence time was 10 minutes. As increased the oxygen concentration of combustion air. temperature of the incinerator was increased and the temperature was increased rapidly when the oxygen concentration was 30%. As increased the oxygen concentration, the NOx (ppm) of flue gas increase d for thermal NOx, however the CO (ppm) of flue gas decreased according to the increase of combustion efficiency . The optimum operation condition of incineration was obtained when the oxygen concentration is 30%${\sim}$40%. The unburned carbon of ash decreased from 10% to 4% when the oxygen concentration was increased from 21% to 30%, therefore the high combustion efficiency can be obtained if used the oxygen enriched combustion system.

  • PDF

Design of Induction Heating Coil for Automatic Hull Forming System

  • Ryu, Hyun-su
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.24 no.3
    • /
    • pp.360-366
    • /
    • 2018
  • In shipyards hull forming is performed by the line heating method using a gas torch and by cold treatment using a roll-press. However, this forming process has some issues, such as difficulties in controlling and accurately estimating the amount of the heat input, as well as a harsh working environment due to exposure to loud noises and air pollution. The induction heating method, which is introduced in this paper, exhibits good control and allows for the estimation of precise heat input. Also, workers can carry out the induction heating in a comfortable working environment. In this research, the induction heating simulation, which consists of electro-magnetic, heat transfer and thermal elasto-plastic analysis, was developed and modified through induction heating experiments. Finally, the effective heating coil was designed for the automatic hull forming system based on the results of induction heating simulation. For the purposes of a future study, if an algorithm to obtain optimal working conditions is developed, automatic systems for hull forming can then be constructed.

Thermal Analysis of Rotary Kiln Incinerator of Municipal Solid Waste (로타리 킬른형 도시 쓰레기 소각로의 전열해석)

  • 박상일;박영재
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.15 no.6
    • /
    • pp.2100-2108
    • /
    • 1991
  • A hear transfer model was developed to calculate the temperature distribution in the rotary kiln incinerator of municipal solid waste. The thermo-gravimetric characteristics of waste and the gas-to-waste heat transfer coefficient were determined by comparing the experimental results and model prediction. With this, heat transfer rates by existing heat transfer mechanisms were calculated to be compared each other. The effects of treatment capacity, calorific value of waste, and flow rate and temperature of combustion air on the temperature distribution in the rotary kiln incinerator were predicted by the model developed in this work.

EffEct of vacuum annealing on an oxidation of milled WC-Co powder (분쇄된 초경합금 분말의 산화에 미치는 진공열처리 효과)

  • 김소나
    • Journal of Powder Materials
    • /
    • v.3 no.2
    • /
    • pp.91-96
    • /
    • 1996
  • The effect of vacuum annealing on the oxidation behavior of milled WC-15%Co powder mixture has been studied. A cobalt component in the milled powder mixture was oxidized preferentially above 175$^{\circ}C$ in air. The specimens showed a steady increase in weight at 175$^{\circ}C$ but did constant weight followed by rapid increase in specimen weight at the beginning above 20$0^{\circ}C$. Oxidation of the milled powder mixture was significantly suppressed by vacuum annealing at 30$0^{\circ}C$ for 10 h. Suppression of oxidation by vacuum annealing and different oxidation behaviors of the milled powder mixture between 175$^{\circ}C$ and 20$0^{\circ}C$, were attributed to removal of strain energy stored in the cobalt powder during vacuum annealing or oxidation treatment above 20$0^{\circ}C$. The role of stored strain energy on oxidation of milled WC-15%Co powder mixture was proved by X-ray diffraction method and differential thermal analysis.

  • PDF

J-aggregates of Merocyanine Dye : formation and structural change on chemical and thermal treatments (메로시아닌 색소의 J-회합체 ; 형성과 열.화학적인 처리에 의한 변화)

  • Shin, Hoon-Kyu;Kwon, Young-Soo
    • Proceedings of the KIEE Conference
    • /
    • 1998.07d
    • /
    • pp.1398-1400
    • /
    • 1998
  • The physical properties of the LB films with merocyanine dyes have been published and attract attention due to the possibility of molecular structure control. The evaluation of the thin films was focused for the purpose of molecular structure control. The molecular structure in the case of the thin films with dyes can be examine by optical absorption spectra measurements. In the case of optical absorption spectra of the LB films by the heat treatment at $70^{\circ}C$ in the air, both of the shifted absorption bands decay and a monomer absorption peak of about 530 nm appears instead. And, the formation and dissociation of J-aggregates, anisotropic behavior was no longer observed in the heat treated merocyanine dyes LB films. In the results, study of the merocyanine dyes LB films using optical absorption spectra would an interesting problem of absorption peak shifts and mixed components.

  • PDF

Effect of vacuum regeneration of activated carbon on volatile organic compound adsorption

  • Pak, Seo-Hyun;Jeon, Yong-Woo
    • Environmental Engineering Research
    • /
    • v.22 no.2
    • /
    • pp.169-174
    • /
    • 2017
  • Vacuum swing adsorption (VSA) is a promising treatment method for volatile organic compounds (VOCs). This study focuses on a VSA process for regenerating activated carbon spent with VOCs, and then investigates its adsorption capacities. Toluene was selected as the test VOC molecule, and the VSA regeneration experiments results were compared to the thermal swing adsorption process. Cyclic adsorption-desorption experiments were performed using a lab-scale apparatus with commercial activated carbon (Samchully Co.). The VSA regeneration was performed in air (0.5 L/min) at 363.15 K and 13,332 Pa. The comparative results depicted that in terms of VSA regeneration, it was found that after the fifth regeneration, about a 90% regeneration ratio was maintained. These experiments thus confirm that the VSA regeneration process has good recovery while operating at low temperatures (363.15 K) and 13,332 Pa.