• Title/Summary/Keyword: Thermal Time Scale

Search Result 251, Processing Time 0.027 seconds

건축물에너지 효율을 위한 조적조 열교 차단 브라켓의 성능 평가 연구 (A Study on Performance Evaluation of Masonry Thermal Bridge Blocking Brackets for Building Energy Efficiency)

  • 김웅회;김형규;이태규;이재현;김규용
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2023년도 봄 학술논문 발표대회
    • /
    • pp.175-176
    • /
    • 2023
  • The masonry structure is constructed by cement mortar binding material of brick objects and uses reinforced hardware(connected hardware or wall tie) together when building. However, over time, the corrosion of reinforced steel and the deterioration of joint mortar as well as bricks cause the risk of collapse. In particular, when the externally decorated brick wall is installed on the concrete girder for each floor, the angle bracket is not constructed or corroded, the full-layer weight load is applied to the wall of 0.5B, which is an example of full-scale or collapse. As a result of the evaluation, it was confirmed that the performance was improved compared to the existing bracket, and we plan to carry out a real-life test and long-term performance review of the building using the bracket in the future.

  • PDF

고전압 펄스 전기장 처리된 미생물 세포의 생리특성 (Physiological Properties of Microbial Cells Treated by Pulsed Electric Field(PEF))

  • 김경탁;김성수;최희돈;홍희도;하상도;이영춘
    • 한국식품과학회지
    • /
    • 제31권2호
    • /
    • pp.368-374
    • /
    • 1999
  • 식품공정에 있어서 비가열 살균 기술로 개발되고 있는 고전압 펄스 전기장(pulsed electric fields, PEF)을 과실주스의 품질 향상에 응용하고자 pilot-scale의 고전압 펄스 전기장 살균장치를 개발하였으며, 이것을 과실 주스의 모델로 선정한 사과주스의 대표적 오염지표균 또는 품질을 저하시키는 미생물 중 Escherichia coli, Bacillus subtilis, Rhodotorula minuta에 적용시켜 세포의 생리특성을 조사하였다. 내염성, 자외선 흡수 물질, 세포염색, 세포의 회복도, 세포의 표면구조 등을 조사함으로서 PEF의 미생물 생리특성에 대한 영향을 규명하고자 하였다. E. coli, B. subtilis, R. minuta를 40 kV/cm, 84 pulse, $10{\mu}s$ pulse duration의 PEF 조건에서 처리하여 내염성을 조사한 결과 1 log cycle 정도의 생존율 감소를 나타내었다. PEF 처리에 의한 세포 내부 성분의 유출 여부를 살펴본 자외선 흡수물질 측정결과 260 nm, 280 nm에서 모두 PEF 처리 세포가 무처리구에 비하여 현저하게 증가된 흡수물질 농도를 나타내었다. PEF 처리된 R. minuta를 세포 염색하여 관찰한 결과 세포막이 터져서 개열됨에 따라 염색시약이 세포 내, 외부로 고루 염색되어 세포 본래의 형태를 관찰할 수가 없었다. PEF 처리후 세포의 회복도는 무처리구에 비하여 E. coli와 B. subtilis가 약 5시간, R. minuta가 약 8시간 정도 지연된 lag time을 보였다. 그리고 PEF 처리후의 E. coli, B. subtilis, R. minuta는 정상적인 세포와는 달리 세포막이 상당한 손상을 입어 허물어진 상태를 관찰할 수 있었다.

  • PDF

Pilot Scale 김치순간살균장치(瞬間殺菌裝置)에서의 살균효과분석(殺菌效果分析) 및 Simulation (Thermal Process Evaluation and Simulation in a Pilot Scale Kimchi Pasteurizer)

  • 길광훈;김공환;전재근
    • Applied Biological Chemistry
    • /
    • 제27권2호
    • /
    • pp.55-63
    • /
    • 1984
  • Pilot scale 연속식(連速式) 김치순간살균장치(瞬間殺菌裝置)를 사용한 무우김치살균시(殺菌時) 살균효과(殺菌效果)를 분석(分析)하기위해 살균시간(殺菌時間)에 따른 생균수(生菌數)의 변화(變化)를 측정(測定)하였으며 simulation model을 설정(設定)하여 김치내(內) 생균수(生菌數)의 감소(減少)를 예측(豫測)하고 실제 실험치(實驗値)와 비교(比較) 분석(分析)함으로써 simulation model의 적용타당성(適用妥當性)을 검정(檢定)하였다. 1. 김치숙성균(熟成菌)의 D값은 가열온도(加熱溫度) 60, 64, 70, 75, $80^{\circ}C$에서 각각(各各) 2.21, 1.62, 0.73, 0.32, 0.21분(分)이었으며 z값은 $19^{\circ}C$였다. 2. 김치시료(試料)를 4 l/min의 유속(流速)으로 1cycle 살균처리(殺菌處理)하는데 소요(所要)되는 시간(時間)은 0.99분(分)으로 약 1분(分)이 소요(所要)되었다. 3. 총살균효과(總殺菌效果)에서 예열부(豫熱部)에서의 살균효과(殺菌效果)가 차지하는 비율(比率)은 30%, 살균(殺菌) 예냉(豫冷) 냉각부(冷却部)에서의 살균효과(殺菌效果)가 차지하는 비율(比率)은 70%이었다. 4. 살균부(殺菌部)의 온도(溫度)가 65, $70^{\circ}C$일때 관내(管內)를 통과하는 김치액(液)의 시간(時間)에 대한 직선적(直線的) 온도변화(溫度變化)와 지수적(指數的) 온도변화(溫度變化)로부터 유도(誘導)된 두개의 simulation model equation에 의한 예측치(豫測値)와 실제 실험치(實驗値)가 비교적(比較的) 잘 일치(一致)하였다.

  • PDF

과열증기 열처리 낙엽송재의 물리·역학적 성능 및 내후성능 평가 (Evaluation of Physico-mechanical Properties and Durability of Larix kaempferi Wood Heat-treated by Superheated Steam)

  • 박용건;박준호;양상윤;정현우;김현빈;한연중;장윤성;김경중;여환명
    • Journal of the Korean Wood Science and Technology
    • /
    • 제44권5호
    • /
    • pp.776-784
    • /
    • 2016
  • 본 연구에서는 pilot scale에서 과열증기를 이용하여 실대재 낙엽송 생재 각재를 열처리하고, 열처리된 낙엽송재의 다양한 물리 역학적 성능과 내후성능을 측정하였다. 또한, 이를 고온 열기 열처리한 낙엽송재의 물성과 비교하였다. 생재로부터 할렬 발생이 억제된 상태로 과열증기 열처리된 낙엽송재의 갈색부후균과 백색부후균에 대한 저항성과 종압축강도는 증가한 반면에 밀도와 평형함수율 및 수축률과 휨강도는 관행 열처리재보다 낮게 측정되었다. 과열증기 목재 열처리는 다량의 수분에 의해 열전달이 빠르고 열가수분해가 촉진되기 때문에 유사한 시간과 온도에서 열기를 이용하여 관행 열처리한 경우보다 열처리 효과가 높게 나타났다. 따라서 과열증기 열처리 방법은 생재를 할렬 없이 열처리할 수 있으며, 관행 열처리 방법보다 낮은 온도 또는 짧은 열처리 시간으로도 동일한 열처리 효과를 발현시킬 수 있다. 즉, 열처리에 소요되는 시간과 에너지를 줄일 수 있다.

An Analytical Investigation on the Build-up of the Temperature Field due to a Point Heat Source in Shallow Coastal Water with Oscillatory Alongshore-flow

  • Jung, Kyung-Tae;Kim, Chong-Hak;Jang, Chan-Joo;Lee, Ho-Jin;Kang, Sok-Kuh;Yjm, Ki-Dai
    • Ocean and Polar Research
    • /
    • 제25권1호
    • /
    • pp.63-74
    • /
    • 2003
  • The build-up of the heat field in shallow coastal water due to a point source has been investigated using an analytical solution of a time-integral form derived by extending the solutions by Holley(1969) and also presented in Harleman (1971). The uniform water depth is assumed with non-isotropic turbulent dispersion. The alongshore-flow is assumed to be uni-directional, spatially uniform and oscillatory. Due to the presence of the oscillatory alongshore-flow, the heat build-up occurs in an oscillatory manner, and the excess temperature thereby fluctuates in that course and even in the quasi-steady state. A series of calculations reveal that proper choices of the decay coefficient as well as dispersion coefficients are critical to the reliable prediction of the excess temperature field. The dispersion coefficients determine the absolute values of the excess temperature and characterize the shoreline profile, particularly within the tidal excursion distance, while the decay coefficient determines the absolute value of the excess temperature and the convergence rate to that of the quasi-steady state. Within the e-folding time scale $1/k_d$ (where $k_d$ is the heat decay coefficient), heat build-up occurs more than 90% of the quasi-steady state values in a region within a tidal excursion distance (L), while occurs increasingly less the farther we go to the downstream direction (about 80% at 1.25L, and 70% at 1.5L). Calculations with onshore and offshore discharges indicate that thermal spreading in the direction of the shoreline is reduced as the shoreline constraint which controls the lateral mixing is reduced. The importance of collecting long-term records of in situ meteorological conditions and clarifying the definition of the heat loss coefficient is addressed. Interactive use of analytical and numerical modeling is recommended as a desirable way to obtain a reliable estimate of the far-field excess temperature along with extensive field measurements.

Investigation of TaNx diffusion barrier properties using Plasma-Enhanced ALD for copper interconnection

  • 한동석;문대용;권태석;김웅선;황창묵;박종완
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2010년도 제39회 하계학술대회 초록집
    • /
    • pp.178-178
    • /
    • 2010
  • With the scaling down of ULSI(Ultra Large Scale Integration) circuit of CMOS(Complementary Metal Oxide Semiconductor)based electronic devices, the electronic devices become more faster and smaller size that are promising field of semiconductor market. However, very narrow line width has some disadvantages. For example, because of narrow line width, deposition of conformal and thin barrier is difficult. Besides, proportion of barrier width is large, thus resistance is high. Conventional PVD(Physical Vapor Deposition) thin films are not able to gain a good quality and conformal layer. Hence, in order to get over these side effects, deposition of thin layer used of ALD(Atomic Layer Deposition) is important factor. Furthermore, it is essential that copper atomic diffusion into dielectric layer such as silicon oxide and hafnium oxide. If copper line is not surrounded by diffusion barrier, it cause the leakage current and devices degradation. There are some possible methods for improving the these secondary effects. In this study, TaNx, is used of Tertiarybutylimido tris (ethylamethlamino) tantalum (TBITEMAT), was deposited on the 24nm sized trench silicon oxide/silicon bi-layer substrate with good step coverage and high quality film using plasma enhanced atomic layer deposition (PEALD). And then copper was deposited on TaNx barrier using same deposition method. The thickness of TaNx was 4~5 nm. TaNx film was deposited the condition of under $300^{\circ}C$ and copper deposition temperature was under $120^{\circ}C$, and feeding time of TaNx and copper were 5 seconds and 5 seconds, relatively. Purge time of TaNx and copper films were 10 seconds and 6 seconds, relatively. XRD, TEM, AFM, I-V measurement(for testing leakage current and stability) were used to analyze this work. With this work, thin barrier layer(4~5nm) with deposited PEALD has good step coverage and good thermal stability. So the barrier properties of PEALD TaNx film are desirable for copper interconnection.

  • PDF

Rapid full-scale expansion joint monitoring using wireless hybrid sensor

  • Jang, Shinae;Dahal, Sushil;Li, Jingcheng
    • Smart Structures and Systems
    • /
    • 제12권3_4호
    • /
    • pp.415-426
    • /
    • 2013
  • Condition assessment and monitoring of bridges is critical for safe passenger travel, public transportation, and efficient freight. In monitoring, displacement measurement capability is important to keep track of performance of bridge, in part or as whole. One of the most important parts of a bridge is the expansion joint, which accommodates continuous cyclic thermal expansion of the whole bridge. Though expansion joint is critical for bridge performance, its inspection and monitoring has not been considered significantly because the monitoring requires long-term data using cost intensive equipment. Recently, a wireless smart sensor network (WSSN) has drawn significant attention for transportation infrastructure monitoring because of its merits in low cost, easy installation, and versatile on-board computation capability. In this paper, a rapid wireless displacement monitoring system, wireless hybrid sensor (WHS), has been developed to monitor displacement of expansion joints of bridges. The WHS has been calibrated for both static and dynamic displacement measurement in laboratory environment, and deployed on an in-service highway bridge to demonstrate rapid expansion joint monitoring. The test-bed is a continuous steel girder bridge, the Founders Bridge, in East Hartford, Connecticut. Using the WHS system, the static and dynamic displacement of the expansion joint has been measured. The short-term displacement trend in terms of temperature is calculated. With the WHS system, approximately 6% of the time has been spent for installation, and 94% of time for the measurement showing strong potential of the developed system for rapid displacement monitoring.

다양한 전처리에 따른 중온혐기-고온호기 복합 슬러지 처리공정의 슬러지 처리효율 및 메탄 생성량 변화 (Effects of diverse Pre-treatment methods on the sludge digestion and methane production in combined mesophilic anaerobic and thermophilic aerobic sludge digestion process)

  • 하정협;박종문;박상규;조현욱;장현민;최석순
    • 유기물자원화
    • /
    • 제21권3호
    • /
    • pp.43-52
    • /
    • 2013
  • 본 연구에서는 유입 슬러지에 다양한 전처리 방법을 적용하여 전처리 방법이 중온혐기-고온호기 복합 슬러지 처리 공정의 슬러지 소화효율과 메탄가스 생성량에 미치는 영향을 비교 검증하였다. 실험실 규모의 슬러지 소화장치를 제작하여 서로 다른 유입 슬러지 전처리방법을 적용하여 4단계로 실험을 진행하였다. 1단계에서는 전처리를 하지 않은 슬러지를 공급하였고, 2, 3, 4단계에서는 각각 열처리, 열-알칼리처리, 장기 알칼리 처리(7일)를 거친 유입 슬러지를 공급하였다. 실험 결과, 1단계에서 4단계까지 진행되는 동안 총COD 제거율은 44%에서 76%까지 증가하였으며, 메탄 생성량 또한 101mL/L/day에서 165, 256mL/L/day까지 크게 증가하였다. 한편, 4단계에서는 7일간의 장기 알칼리 처리를 하였음에도 불구하고 3단계에 비해 총COD 제거율과 메탄 생성량이 증가하지 않았다. 결론적으로, 유입 슬러지의 전처리를 통해 복합 슬러지 처리 공정의 슬러지 제거 효율과 메탄생성량을 크게 증가시킬 수 있었으며, 여러 가지 전처리 방법 중 열-알칼리 처리법이 가장 효율적임을 실험결과를 통해 알 수 있었다.

대구경 현장타설 에너지파일의 열교환 성능과 시공성 및 경제성 분석 (Evaluation on Thermal Performance Along with Constructability and Economic Feasibility of Large-diameter Cast-in-place Energy Pile)

  • 박상우;성치훈;이동섭;정경식;최항석
    • 한국지반공학회논문집
    • /
    • 제31권5호
    • /
    • pp.5-21
    • /
    • 2015
  • 에너지파일이란 새로운 형식의 지중열교환기로서, 건물의 기초 구조물인 말뚝 내부에 열교환 파이프를 삽입하고 파이프 내부로 유체를 순환시켜 지반과 말뚝 매질사이의 열교환을 유도한다. 에너지파일은 기존의 기초 구조물을 활용하여, 구조물의 지지 기능과 지중열교환기로서의 기능을 동시에 수행하는 에너지 구조체이다. 본 연구에서는 에너지파일의 실증연구를 위하여 총 6가지 형태의 열교환 파이프가 삽입된 실규모 현장타설 에너지파일을 시험 시공하였다. 열교환 파이프의 형태는 다양한 형태별 성능 및 시공성 비교를 위해 병렬 U형 3본(5쌍, 8쌍, 10쌍), 코일형 2본(피치간격 200mm와 500mm), S형 1본으로 선정하였다. 총 6가지 형태의 열교환 파이프를 시공하면서 시공 소요시간, 인력 소요, 필요 부대시설, 특이사항 등을 정리하여 각 형태별 시공성을 평가하였다. 또한 시공된 현장타설 에너지파일에 대한 열교환 성능 평가시험을 수행하였다. 열교환 성능 평가시험은 실제 상업 건물의 냉방 부하를 모사하기 위하여 8시간 가동 16시간 휴지의 간헐적 가동을 통하여 수행하였다. 열교환 성능 평가시험 결과를 통하여 각 현장타설 에너지파일의 열교환량을 산정하였으며, 이를 에너지파일 근입 깊이 및 열교환 파이프 길이로 정규화하여 각 형태별 열교환 효율을 평가하였다. 마지막으로 현장타설 에너지파일의 경제성을 분석하기 위하여 각 형태별 에너지파일의 시공비와 에너지파일 단위 길이 당 열교환 성능을 통해 1W/m 당 소요 비용을 산정하였다.

반밀폐된 구획에서 발열량 변화에 따른 비정상 화재특성 (Effects of Change in Heat Release Rate on Unsteady Fire Characteristics in a Semi-Closed Compartment)

  • 황철홍
    • 한국화재소방학회논문지
    • /
    • 제26권2호
    • /
    • pp.75-83
    • /
    • 2012
  • 반밀폐된 구획에서 발열량 변화에 따른 환기부족화재의 비정상 열 및 화학적특성에 관한 실험적 연구가 수행되었다. 이를 위해 실규모 ISO 9705 표준화재실의 출입구 폭이 0.1 m로 축소되었으며, 구획 중앙에 설치된 분사노즐을 통해 헵탄 연료의 유량은 선형적으로 증가되었다. 구획 내부의 온도, 열유속, 화학종농도 그리고 발열량의 연속적 측정이 이루어졌으며, 비정상 열 및 화학적특성을 표현하기 위하여 총괄 당량비의 개념이 적용되었다. 주요 결과로서, 총괄 연소효율과 구획 내부의 국부 연소효율은 시간에 따라 매우 다른 결과를 보이며, 이론과 측정된 발열량을 통한 총괄 당량비 역시 큰 차이를 보이게 된다. 온도, 열유속 및 화학종 농도의 시간에 따른 변화는 총괄 당량비 개념를 통해 표현될 수 있었다. 구획 내부에서 CO의 농도는 총괄 당량비 2.0~3.0의 범위에서 최대값을 보이며, 보다 과농한 조건에서 점차적으로 감소되는 현상이 발견되었다. 추가로 본 실험을 통해 얻어진 반밀폐된 구획화재의 비정상 열 및 화학적 거동은 향후 현실적인 화재 모델링을 위한 검증 데이터로 활용될 수 있을 것으로 기대된다.