• Title/Summary/Keyword: Thermal Test Equipment

Search Result 155, Processing Time 0.037 seconds

Equipment Qualification of a Safety-related Large Induction Motor for Nuclear Power Plants (원자력발전소 안전등급 대형유도전동기의 기기검증)

  • Lee, Hyoung-Woo;Ko, Woo-Sik;Ryu, Jeong-Hyeon;Park, No-Gill
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.24 no.6
    • /
    • pp.72-77
    • /
    • 2007
  • A safety-related equipment for the nuclear power plant should be needed an equipment qualification. In this paper, the approach, methods, philosophies, and procedures for qualifying the large squirrel-cage induction electric pump motors for use in ULCHIN 5, 6 Nuclear Power Plants were presented. The method of qualification is a combination of experimental test and analytic method, which is composed of radiation exposure test, seismic simulation test, thermal aging analysis for non-metallic materials, and seismic analysis. The results showed that the motor performed its safety function with no failure mechanism under postulated service conditions.

Study on the equivalent test equipment for AC Motor (전력회생형 부하시험장치에 관한 연구)

  • 김현수;김한종;허재영;최창식;이제필;장철호;정종태
    • Proceedings of the KIPE Conference
    • /
    • 1997.07a
    • /
    • pp.295-298
    • /
    • 1997
  • In large system, design margin makes relatively price higher. So, optimal design through exact analysis of thermal behavior is needed. In this paper, we propose the equivalent load test facility using two inverter & converter system and inductors. Applying actual electrical profiles for motor drive, thermal characteristics of power converter fed AC motor drive are obtained, and the results are compared with simulation results.

  • PDF

The Research of the HERO Test and Evaluation Technique (HERO 시험평가 기법 연구)

  • Shin, Seung-Je
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.10 no.2
    • /
    • pp.76-83
    • /
    • 2007
  • This report presents the test technique using optic thermal sensor for the HERO evaluation of equipment installed EED. The calibration method of EED-thermal sensor assembly is explained by relation between the current in bridge wire and voltage in thermal sensor. And the HERO test and evaluation method is indicated based on MIL-STD-464A and MIL-STD-331C. The safety and reliability levels of EED-thermal sensor assembly are evaluated when exposed in the electromagnetic environment.

A Numerical Study on the Thermal Behavior Evaluation of Bentonite Buffer (벤토나이트 완충재의 열적 거동 평가에 관한 수치해석적 연구)

  • Yoon, Chan-Hoon;Choi, Young-Chul;Choi, Heui-Joo
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.13 no.2
    • /
    • pp.99-112
    • /
    • 2015
  • In this study, laboratory test equipment was designed and installed to evaluate the thermal behavior of bentonite, which is used as a buffer in high-level waste disposal systems. The thermal analysis was conducted to verify the test results using ABAQUS, a finite element analysis code. In view of the seasonal changes seen during the test, the thermal behavior of bentonite with a temperature of outside air was evaluated. Of the cases examined, the results of the analysis model using stainless steel (Case 3) approximates to the test results, showing an error of about 1℃. The results of the thermal analysis into seasonal temperature distributions are consistent with trends seen in lab-test results. These analyses show that the effects of the thermal conductivity of the material surrounding the buffer and outside air temperature, are very important factors in the thermal behavior of bentonite. In the future, it is expected that a moisture saturation test of a bentonite buffer containing a heat source will be carried out. Therefore, the development of a numerical analysis model is required for the prediction and verification of the laboratory test results.

Study on the characteristics of acid resistance and thermal shock for epoxy coatings (에폭시계 코팅재의 내산열충격 특성에 관한 연구)

  • Lee, Sang-Yeal;Yun, Byoung-Du
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.43 no.4
    • /
    • pp.362-369
    • /
    • 2007
  • This paper was studied on the characteristics of acid resistance and thermal shock for epoxy coatings in the strong acidic environment. The exhaust gas system, such as a air preheater, desulfurization equipment, for industrial boiler is damaged by dew point corrosion. To protect the acid corrosion, the coating using nonmetal was applied. The electrochemical polarization test, acid resistance and thermal shock test for epoxy coatings were carried out. And the acid resistance and thermal shock characteristics, aspect, and electrochemical anti-corrosion characteristics for epoxy coatings in the strong acidic environment were considered. The main results are as followings: As the epoxy glass flake coating by acidic thermal shock was damaged to the crack, blistering and elution etc., the current density of epoxy glass flake coating is high. But the damage of epoxy metal complex coating by acidic thermal shock was not occurred. Therefore the characteristics of acid resistance and thermal shock for epoxy metal complex coating is better than those for epoxy glass flake coating.

An Experimental Study on the Characteristic of Thermal Performance according to Feed Water Conditions to of Vacuum Membrane Distillation Module using PVDF Hollow Fiber (PVDF 중공사막을 이용한 진공 막 증류 모듈의 공급수 조건에 따른 열성능 특성에 관한 실험적 연구)

  • Joo, Hongjin;Kwak, Heeyoul
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.31 no.4
    • /
    • pp.339-346
    • /
    • 2017
  • In this study, thermal performance test of VMD module was performed, prior to the construction of the demonstration plant using the vacuum membrane distillation (VMD) module of the capacity of $400m^3/day$ and to the commercialization of the VMD module. For the thermal performance test, the experimental equipment of capacity of $2m^3/day$ was constructed. The permeate flux test and thermal performance test according to feed water conditions such as temperature and flow rate were conducted. The VMD module used in the study was manufactured by ECONITY Co., LTD with PVDF hollow fiber membrane. As a result, the Performance Ratio (PR) of the VMD module showed the maximum value of 0.904 under the condition of feed water temperature of $75^{\circ}C$ and flow rate of $8m^3/h$. PR value of the VMD module using PVDF hollow fiber membrane showed linearly increasing relationship with feed water temperature and flow rate. Also, The permeate flux of the VMD module was analyzed to have maximum value of 18.25 LMH and the salt rejection was 99.99%.

Anaysis of Equipment Qualification Tests for IMCS(Integrated Monitoring & Control System) in Thermal Power Plants (화력발전소 통합감시제어시스템의 기기검증시험 사례 분석)

  • Shin, Man-Su;Lee, Joo-Hyun;Park, Du-Yong;Byun, Seung-Hyun;Choi, In-Kyu;Lee, Se-Gyeong
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1820-1821
    • /
    • 2011
  • The equipment qualification test was accomplished before application to power generating stations because troubles in applying to real system could be prevented trough the test. That is, if a system was judged to be suitable in the equipment qualification test, the system was expected to be operated stable to the designed life.

  • PDF

Durability of Nozzle Materials for Strip Casting of Amorphous Alloys (비정질합금 박판 제조용 노즐 재료의 내구성평가)

  • Kang, Bok-Hyun;Kim, Ki-Young
    • Journal of Korea Foundry Society
    • /
    • v.31 no.5
    • /
    • pp.267-273
    • /
    • 2011
  • Erosion and thermal shock resistance of several refractory materials have been investigated, which are expected to be used as nozzles in a planar flow casting equipment for amorphous alloys. The test was conducted on five materials; graphite, boron nitride, fused silica, alumina and zirconia. Test specimens were preheated and dipped into the melt of carbon steel and amorphous alloys. Some test specimens were rotated to develop high erosion and to shorten the test periods. Fused silica and boron nitride specimens showed the excellent erosion and thermal shock resistance irrespective of the kind of melt and melting atmosphere.

A study on the thermal deformation characteristics of steel plates due to multi-line heating

  • Lee, Joo-Sung;Lee, Sang-Hoon
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.10 no.1
    • /
    • pp.48-59
    • /
    • 2018
  • This paper is mainly concerned with developing the formulae of predicting thermal deformation of steel plate due to multi-line heating. By investigating the results of line heating test and numerical analysis, reasonable heat flux model has been defined. Formulae of predicting the transverse shrinkage and the angular distortion as the dominant thermal deformation types in plate forming by line heating have been derived based on the results of line heating test and numerical analysis with varying plate thickness, heating speed and distance between torches. This paper illustrates how the derived formulae are used in investigating the effect of multi-line heating upon the thermal deformation and how they can be used in defining the limit distance with that there is no interacted effect between torches. This paper ends with describing the extension of the present study.

An Experimental Study on Quality Management of Strength in High Strength Mass Concrete Structure Using Thermal Insulation Material (보온재를 사용한 고강도 매스 콘크리트의 품질관리에 관한 연구)

  • Cho, Kyu-Hyun;Back, Min-Soo;Kim, Sung-Sik;Lim, Nam-Gi;Lee, Young-Do
    • Journal of the Korea Institute of Building Construction
    • /
    • v.4 no.2
    • /
    • pp.113-118
    • /
    • 2004
  • This study is a basic experiment on quality management of the compression strength of high strength concrete, aiming. at quality management of high strength mass concrete by giving the temperature hysteresis of the mass test pieces to managerial test pieces. Different from ordinary concrete, high strength concrete generally shows the temperature high rising caused by hydration heat inside the concrete. It is known that, in mass concrete, thermal stress occurs due to the difference in temperature between the inside and the outside, which causes a significant difference in compression strength between structure beams and managerial test pieces. It is also reported that there is a large difference between the compression strength of cylindrical managerial test pieces of standard underwater curing and the strength of structure beam concrete. Thus, this study made concrete test pieces in an optimal mix ratio for each strength level, and also created thermal insulation curing box and managerial test pieces. Then it carried out comparative analysis in relation to core strength and suggested equipment and a technique that can control the strength of high strength concrete mass more conveniently and accurately.