• 제목/요약/키워드: Thermal Sensitivity

검색결과 640건 처리시간 0.033초

Local Flow Speed Measurement Using Tunable AC Thermal Anemometry

  • Chung Won Seok;Kwon Ohmyoung;Lee Joon Sik;Choi Young Ki;Park Seungho
    • Journal of Mechanical Science and Technology
    • /
    • 제19권7호
    • /
    • pp.1449-1459
    • /
    • 2005
  • This paper shows the results of local flow speed measurement using tunable AC thermal anemometry, which is suitable for the accurate measurement of wide range flow speed. The measurement accuracy is verified through the comparison between the measurement data and the analytic solution of the sensor temperature oscillation in stationary fluid. The relation between the phase lag and the flow speed is experimentally investigated at various conditions. The measurement sensitivity for low flow speed improves in a low frequency region and that for high flow speed improves in a high frequency region. Also, the sensitivity increases with decreasing thermal conductivity of the surrounding fluid. The local flow speed could be measured as low as 1.5 mm/s and the highest measurement resolution was 0.05 mm/s in the range of 4.5 $\~$5.0 mm/s at 1 Hz in this experiment.

주거용 건물의 유형에 따른 환경조절요구에 대한 분석 (An Analysis of Demand for Environmental Controls on Different Residential Building Types)

  • 이승복;원종서
    • 설비공학논문집
    • /
    • 제16권10호
    • /
    • pp.960-968
    • /
    • 2004
  • One of the most important functions of a building is to provide thermally comfortable indoor environmental conditions for the occupants. Therefore, a great deal of energy is consumed for heating and cooling to satisfy those thermal requirements. In order to provide thermal comfort with minimum heating and cooling energy consumption, optimal design of building affecting indoor climate is required. This study used the TRNSYS for modeling and simulation of the energy flows of residential building types, and examined the energy efficient measures to reduce the thermal loads. The residential building types are classified into the detached house, apartment house and high-rise residential complex. The results of the simulation show that the heating energy consumption in the detached house is especially high, whereas the cooling load is an important determinant in the apartment house and high-rise residential complex. The measures examined are the insulation thickness, various types of glazing, infiltration, natural and controlled ventilation, solar shading, orientation and etc. Comparative evaluations and sensitivity analyses revealed the effects of these variables and identified their energy efficient building design strategies.

Micromechanical 시험법과 AE를 이용한 세라믹 PZT 및 고분자 PVDF 센서에 따른 단섬유 강화 에폭시 복합재료의 비파괴 손상감지능 비교 (Comparison of Nondestructive Damage Sensitivity of Single Fiber/Epoxy Composites Using Ceramic PZT and Polymeric PVDF Sensors By Micromechanical Technique and Acoustic Emission)

  • 정진규;김대식;박종만;윤동진
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2004년도 춘계학술발표대회 논문집
    • /
    • pp.135-138
    • /
    • 2004
  • Conventional piezoelectric lead-zirconate-titanate (PZT) senor has high sensitivity, but it is very brittle. Recently polymer films such as polyvinylidene fluoride (PVDF) and poly(vinylidene fluoride­trifluoroethylene) (P(VDF-TrFE)) copolymer have been used as a sensor. The advantages of polymer sensor are the flexibility and mechanical toughness. Simple process and possible several shapes are also additional advantages. Polymer sensor can be directly embedded in a structure. In this study, nondestructive damage sensitivity of single basalt fiber/epoxy composites was investigated with sensor type and thermal damage using AE and oscilloscope. And AE waveform for epoxy matrix with various damage types was compared to each other. The damage sensitivity of two polymer sensors was rather lower than that of PZT sensor. The damage sensitivity of PVDF sensor did not decrease until thermal damage temperature at $80^{\circ}C$ and they decreased significantly at $110^{\circ}C$ However, the damage sensitivity of P(VDF-TrFE) sensor at $110^{\circ}C$ was almost same in no damage sensor. For both top and side impacts, the difference in arrival time increased with increasing internal and surface damage density of epoxy matrix.

  • PDF

알루미늄 지지대에 고정된 융착 광섬유 커플러의 열팽창을 이용한 온도 센서 (Fiber Optic Temperature Sensor Based on the Thermal Expansion Effect of Fused Optical Fiber Coupler Fixed on a Al Support)

  • 김광택
    • 센서학회지
    • /
    • 제26권5호
    • /
    • pp.338-341
    • /
    • 2017
  • We have investigated a temperature sensor on a thermal expansion effect of a fused optical fiber coupler. Both side of the fused tapered region of the coupler were fixed on a metal support to induce the high thermal expansion effect. The sensor showed that the peak coupling wavelengths were shifted to shorted wavelength region with increased of environmental temperature. The sensitivity of the sensor was $0.12nm/^{\circ}C$.

ASPEN PLUS®를 이용한 태양열 유기랭킨사이클 열병합 발전시스템의 공동주택 적합도 분석 (Feasibility of a Solar Thermal Organic Rankine Cycle Power Plant for an Apartment Complex with Aspen Plus®)

  • 임석연;김형근;유상석
    • 대한기계학회논문집B
    • /
    • 제39권4호
    • /
    • pp.317-324
    • /
    • 2015
  • 본 연구에서는 아파트단지에 적용되는 태양열 급탕 시스템의 에너지 활용도를 높이기 위해 유기랭킨사이클을 적용하여 해석적 연구를 수행하였다. 시스템 해석은 Aspen $Plus^{(R)}$을 활용하였으며 태양열집열기는 급탕 온도와 유기랭킨 사이클의 운전 조건을 고려하여 진공관형 집열기를 적용하였다. R134a, R141a, R245fa 등의 냉매를 작동유체로 선정하였으며, 시스템 성능해석을 통하여 R245fa 냉매가 적용가능성이 가장 높게 나타났다. 비가역성 해석과 민감도 해석을 통해 유기랭킨 사이클 시스템의 효율 및 성능 확보를 위해서는 증발기와 터빈에 대한 기술 개발이 매우 중요하다는 것을 밝혀냈으며, 순수 급탕으로만 활용하는 시스템에 전기 생산 설비를 추가하게 되면 약 50%의 추가적인 경제성이 확보됨을 확인하였다.

EXPERIMENTS ON THE PERFORMANCE SENSITIVITY OF THE PASSIVE RESIDUAL HEAT REMOVAL SYSTEM OF AN ADVANCED INTEGRAL TYPE REACTOR

  • Park, Hyun-Sik;Choi, Ki-Yong;Choi, Seok;Yi, Sung-Jae;Park, Choon-Kyung;Chung, Moon-Ki
    • Nuclear Engineering and Technology
    • /
    • 제41권1호
    • /
    • pp.53-62
    • /
    • 2009
  • A set of experiments has been conducted on the performance sensitivity of the passive residual heat removal system (PRHRS) for an advanced integral type reactor, SMART, by using a high temperature and high pressure thermal-hydraulic test facility, the VISTA facility. In this paper the effects of the opening delay of the PRHRS bypass valves and the closing delay of the secondary system isolation valves, and the initial water level and the initial pressure of the compensating tank (CT) are investigated. During the reference test a stable flow occurs in a natural circulation loop that is composed of a steam generator secondary side, a secondary system, and a PRHRS; this is ascertained by a repetition test. When the PRHRS bypass valves are operated 10 seconds later than the secondary system isolation valves, the primary system is not properly cooled. When the secondary system isolation valves are operated 10 or 30 seconds later than the PRHRS bypass valves, the primary system is effectively cooled but the inventory of the PRHRS CT is drained earlier. As the initial water level of the CT is lowered to 16% of the full water level, the water is quickly drained and then nitrogen gas is introduced into the PRHRS, resulting in the deterioration of the PRHRS performance. When the initial pressure of the PRHRS is at 0.1MPa, the natural circulation is not performed properly. When the initial pressures of the PRHRS are 2.5 or 3.5 MPa, they show better performance than did the reference test.

태양열 발전시스템 경제성 분석 (Economic Assessment of Solar Thermal Power System)

  • 김진수;강용혁;김종규
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2008년도 추계학술발표대회 논문집
    • /
    • pp.25-29
    • /
    • 2008
  • Economic assessment of solar thermal power generation systems was carried out by calculating the levelized electricity cost. Four different commercial (or near commercial) solar thermal power systems (parabolic trough system, power tower system with saturated steam, power tower system with molten salts, and dish-stilting system) were considered for assessment. The assessment also included sensitivity analysis covering the effects of system capacity, direct normal insolation, and the system efficiency.

  • PDF

Thermal Fluid Mixing Behavior during Medium Break LOCA in Evaluation of Pressurized Thermal Shock

  • Jung, Jae-Won;Bang, Young-Seok;Seul, Kwang-Won;Kim, Hho-Jung
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1998년도 춘계학술발표회논문집(1)
    • /
    • pp.635-640
    • /
    • 1998
  • Thermal fluid mixing behavior during a postulated medium-size hot leg break loss of coolant accident is analyzed for the international comparative assessment study on pressurized thermal shock (PTS-ICAS) proposed by OECD-NEA. The applicability of RELAP5 code to analyze thermal fluid mixing behavior is evaluated through a simple modeling relevant to the problem constraints. Based on the calculation result, the onset of Thermal stratification is investigated using Theofanous's empirical correlation. Sensitivity calculations using a fine node model and crossflow model are also performed to evaluate the modeling capability on multi-dimensional characteristics related to thermal fluid mixing.

  • PDF

샘플링 기반 민감도를 이용한 국부 유도 가열용 코일의 최적 설계 (Optimal Design of Local Induction Heating Coils Based on the Sampling-Based Sensitivity)

  • 최낙선;김동욱;김동훈
    • 한국자기학회지
    • /
    • 제23권3호
    • /
    • pp.110-116
    • /
    • 2013
  • 본 논문에서는 전자기 결합 문제에 대한 효율적인 최적 설계를 위하여 샘플링 기반 민감도법을 제시하였다. 전자기 해석과 열/구조 해석 사이의 결합 특성에 무관하게 최적해를 도출하기 위하여 블랙박스 개념에 기초한 설계기법이 적용되었다. 현 설계점을 중심으로 초입방체 국부 영역에서 크리깅 근사모델을 생성하고 근사모델의 기저함수의 미분을 통하여 설계민감도 값을 도출하였다. 제안된 설계기법은 샘플링 기반 설계기법과 민감도 기반 설계기법의 장점만을 취한 혼합형 설계기법으로 열/구조 특성과 강성 결합된 전자기 문제의 최적 설계에도 적용이 가능하다. 제안된 방법은 비선형성이 강한 수학 예제 및 과도상태 해석이 요구되는 국부 유도가열용 코일 설계에 적용하여 그 정확성과 타당성을 검증하였다.

Optical Sensitivity of TL Glow Peaks Separated Using Computerized Glow Curve Deconvolution for RTL Quartz

  • Kim, Myung-Jin;Kim, Ki-Bum;Hong, Duk-Geun
    • Journal of Radiation Protection and Research
    • /
    • 제43권3호
    • /
    • pp.114-119
    • /
    • 2018
  • Background: The retrospective dosimetry using RTL quartz can be improved by information for an optical sensitivity of sample connected with the equivalent dose determination. Materials and Methods: The quartz sample from a volcanic rock of Japan was used. After correcting the thermal quenching effect, RTL peaks of quartz were separated by the CGCD method cooperated with the general order kinetics. The number of overlapped glow peaks were ascertained by the $T_m-T_{stop}$ method. The optical sensitivity was examined by comparing the change of intensity on RTL glow peaks measured after exposure to light from a solar simulator with various illumination times. Results and Discussion: Seven glow peaks appeared to be overlapped on the RTL glow curve. The general order kinetics model was appropriate to separate glow peaks. After exposure to light from a solar simulator from a few minutes to 416 hr, the signals for peaks P4 and P5 decayed following the form of $f(t)=a_1e^{-{\lambda}1t}$, while the signals for peaks P6 and P7 decayed by the form of $f(t) = a_1e^{-{\lambda}1t}+a_2e^{-{\lambda}2t}+a_3e^{-{\lambda}3t}$. Conclusion: For dosimetric peaks, the times taken to reduce the RTL signal to half of its initial value were 70 sec for the peak P4, 54 s for the peak P5, 9,840 sec for the peak P6 and 26,580 sec for the peak P7, respectively. We conclude that the optical sensitivity of peaks P4, and P5 gives much higher than that of peaks P6 and P7.