• Title/Summary/Keyword: Thermal Sensitivity

Search Result 640, Processing Time 0.025 seconds

Level Set based Shape Optimization using Extended B-spline Bases (확장 B-spline 기저 함수를 이용한 레벨셋 기반의 형상 최적 설계)

  • Kim, Min-Geun;Cho, Seon-Ho
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2008.04a
    • /
    • pp.391-396
    • /
    • 2008
  • A level set based topological shape optimization using extended B-spline basis functions is developed for steady state heat conduction problems. The only inside of complicated domain is identified by the level set functions and taken into account in computation. The solution of Hamilton-Jacobi equation leads to an optimal shape according to the normal velocity field determined from the sensitivity analysis, minimizing a thermal compliance while satisfying a volume constraint. To obtain exact shape sensitivity, the precise normal and curvature of geometry need to be determined using the level set and B-spline basis functions. The nucleation of holes is possible whenever and wherever necessary during the optimization using a topological derivative concept.

  • PDF

Design and Fabrication of Piezoceramic Cantilever Type Vibration Sensors (압전세라믹 외팔보형 진동센서의 설계 및 제작)

  • 정이봉;노용래
    • Journal of KSNVE
    • /
    • v.7 no.3
    • /
    • pp.377-386
    • /
    • 1997
  • A cantilever type piezoceramic vibration sensor was developed that could make up for the short-comings of current vibration sensors, such as high price, low sensitivity, and complex structure. For the design, in conjunction with piezoelectric constitutive equations, we derived full analytic response equations of the piezoelectric bimorph sensor to external forces. The external forces were supposed to take the form of either step or sinusoidal force. Based on the results, actual piezoelectric vibration sensors were fabricated and tested for verification of the theoretical results. Further, comparison of the performance of the developed sensor was made with that of a commercially available representative vibration sensor so that quantitative evaluation of its sensitivity could be made. The sensor developed in this work showed excellent sensitivity and thermal stability in addition to the merits of simple structure and low fabrication cost in comparison with conventional mass-loaded piezoelectric sensors.

  • PDF

Model Updating of an Equipment Panel with Embedded Heat Pipes (히트 파이프가 내장된 통신위성용 탑재체 패널의 해석모델 개선)

  • 양군호;최성봉;김흥배;문상무
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1998.04a
    • /
    • pp.114-121
    • /
    • 1998
  • This paper presents the model updating of an equipment panel by using modal test and sensitivity analysis. The equipment panel is one of the major structures of communication satellite, on which broadcasting and communication equipments are mounted. For high rigidity and light weight, the panel was designed as an aluminum honeycomb sandwich panel. In addition, heat pipes were embedded in the panel for thermal control. It is essential to improve the finite element model of a satellite by using modal test in order to verify the satellite is designed with adequate margin under launch environment. In this paper, Young's modulus of aluminum facesheet was selected as a modified parameter by sensitivity analysis. The effect of rotational springs of boundary points was also considered.

  • PDF

A Study on the Oil Temperature Control Errors of Precision Oil Coolers (정밀 오일냉각기의 오일온도 제어오차에 관한 연구)

  • 이상호;이찬홍;김갑순
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.451-454
    • /
    • 2003
  • The Oil Coolers is very important unit for the stable thermal performance in machine tools, semiconductor equipments and high precision measuring systems. To select a proper oil cooler for the temperature control of core unit in a machine, not only cooling ability but also static and dynamic sensitivity of temperature sensors are considered. In this paper, the relationship between cooling ability and inflow oil temperature is identified. The cooling ability is increased with the increase of inflow oil temperature. The oil temperature control errors of a cooler are influenced by mainly sensitivity of temperature sensors and heating velocity in a machine. The validity of error cause analysis for temperature control is proved by real cooling experiments with inflow and outflow temperature sensors.

  • PDF

Contribution of lysine-containing cationic domains to thermally-induced phase transition of elastin-like proteins and their sensitivity to different stimuli

  • Jeon, Won-Bae
    • BMB Reports
    • /
    • v.44 no.1
    • /
    • pp.22-27
    • /
    • 2011
  • A series of elastin-like proteins, $SKGPG[V(VKG)_3VKVPG]_n$-(ELP1-90)WP (n = 1, 2, 3, and 4), were biosynthesized based on the hydrophobic and lysine linkage domains of tropoelastin. The formation of self-assembled hydrophobic aggregates was monitored in order to determine the influence of cationic segments on phase transition properties as well as the sensitivity to changes in salt and pH. The thermal transition profiles of the proteins fused with only one or two cationic blocks (n = 1 or 2) were similar to that of the counterpart ELP1-90. In contrast, diblock proteins that contain 3 and 4 cationic blocks displayed a triphasic profile and no transition, respectively. Upon increasing the salt concentration and pH, a stimulus-induced phase transition from a soluble conformation to an insoluble aggregate was observed. The effects of cationic segments on the stimuli sensitivity of cationic bimodal ELPs were interpreted in terms of their structural and molecular characteristics.

Preparation and Swelling Behaviors of Hydrogel Composed of Alginate, Poly(N-isopropylacrylamide) and Polyaniline

  • Lee, Young Moo;Seo, Sung Mi;Lee, Sang Bong
    • Korean Membrane Journal
    • /
    • v.6 no.1
    • /
    • pp.37-43
    • /
    • 2004
  • Comb-type graft hydrogels composed of alginate and poly(N-isopropylacrylamide) (PNIPAAm) were prepared to manifest rapid temperature and pH sensitivity. To appear the electro-sensitivity, the polyaniline, conducting polymer, was added into the matrix. The swelling kinetics and ratios were compared under the various compositions of polyaniline. The swelling behaviors revealed that conducting polymer/hydrogel composites could control the swelling ratio and kinetics. The addition of polyaniline in the matrix improved the thermal stability in comparison with that of the hydrogel without polyaniline. In temperature sensitivity, the adding the polyaniline into the matrix decreased the degree of change in the swelling ratio. The swelling ratios continuously increased with increasing pH values. The drug release rate from the hydrogel increased with the adding the polyaniline and the applying the direct voltage to the hydrogels.

A comparative study of three different viability tests for chemically or thermally inactivated Escherichia coli

  • Park, Seon Yeong;Kim, Chang Gyun
    • Environmental Engineering Research
    • /
    • v.23 no.3
    • /
    • pp.282-287
    • /
    • 2018
  • Three different methods of bacterial viability monitoring were compared to detect chemically or thermally inactivated Escherichia coli. Direct colony enumeration, live/dead bacterial cell staining with a fluorescent dye, and the dehydrogenase activity assay were compared with respect to their ease of use and time required to perform the three different tests. The green (live cell)/red (dead cell) ratio obtained from the fluorescent bacterial cell staining approach showed a linear relationship with the colony forming units; the result obtained with dehydrogenase was similar to those. The sensitivity of the monitoring methods to detect bacterial deactivation varied with different disinfection conditions. After thermal treatment, the sensitivity of the staining approach was lower, while that of the dehydrogenase activity assay was the highest. After chemical treatment, the sensitivity of detection for both methods was similar.

Model Updating of an Equipment Panel with Embedded Heat Pipes (히트 파이프가 내장된 통신위성용 탑재체 패널의 해석모델 개선)

  • 양군호;최성봉;김홍배;문상무
    • Journal of KSNVE
    • /
    • v.9 no.2
    • /
    • pp.248-257
    • /
    • 1999
  • This paper presents the model updating of an equipment panel by using modal test and sensitivity analysis. The equipment panel is one of the major structures of communication satelite, on which broadcasting and communication equipments are mounted. For high rigidity and light weight, the panel was designed as an aluminum honeycomb sandwich panel. In addition, heat pipes were embedded in the panel for thermal control. It is essential to improve the finite element model of a spacecraft structure by using modal test in order to verify that the satellite is designed and fabricated with adequate margin under launch environment. In this paper, Young's modulus of aluminumfacesheet was selected as a modified parameter in the sensitivity analysis. The effect of boundary conditions on model improvement was also investigated.

  • PDF

Sensitivity Analysis for Allowable Operating Period Based on the Flaw Tolerance Evaluation of ASME BPVC Section XI Appendix L (ASME BPVC Section XI Appendix L의 결함허용평가에 따른 허용운전주기 민감도 분석)

  • Changsik Oh;Dooho Cho;Myung Jo Jhung
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.17 no.2
    • /
    • pp.126-136
    • /
    • 2021
  • During operation of nuclear power plants, the fatigue assessment should be conducted repeatedly, considering changes of operating environments. For the case that cumulative usage factors (CUFs) may exceed the acceptance limit, flaw tolerance evaluation can be an alternative method to meet the regulatory requirements. In this respect, this paper analyzes the effects of the input variables for flaw tolerance evaluation based on ASME BPVC Section XI Appendix L. The reference analysis is performed for the example problem in NUREG/CR-6934. Then effects of the crack orientation, stress intensity factor solutions, thermal stress profiles, fatigue stress decomposition and fatigue crack growth curves are considered for the sensitivity analysis. The results show that the stress analysis considering the actual environment plays a crucial role in flaw tolerance evaluation.

Application of Graphene Platelets on Electronic Controlled Thermostat of TGDI Engine for Improving Thermal Sensitivity (TGDI엔진용 전자식 수온조절기의 감온성능 향상을 위한 그래핀 소재의 적용)

  • Kim, SeoKyu;Kim, YongJeong;Joung, Heehwa;Jeon, Wonil;Jeong, Jinwoo;Jeong, SooJin
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.25 no.1
    • /
    • pp.66-73
    • /
    • 2017
  • In this work, graphene platelets were introduced into wax in an automotive electronic controlled thermostat for the purpose of enhancing its thermal-conductive property and improving response performance. Graphene content ranging from 10 % to 20% was added into and mixed with the wax to investigate the effect of graphene amounts on the performance of an automotive electronic controlled thermostat in terms of response time, hysteresis and melting temperature. The experimental results revealed that graphene in wax contributed to a reduction in the response time and hysteresis of an automotive electronic controlled thermostat. As a consequence, important improvement in thermal sensitivity, full lift, melting temperature and hysteresis were obtained. The thermal response of wax with graphene content of 20 % was improved by 25 %, as compared to that of wax with Cu content of 20 %. Hysteresis of wax with graphene was reduced by $0.6^{\circ}C$ as compared to that of wax with Cu content. The melting temperature of wax is lowered and hysteresis is also improved with increased graphene content of wax in an electronic controlled thermostat. We hope that this study can help further the transition of nano-fluid technology from small-scale research laboratories to industrial application in the automotive sector.