• Title/Summary/Keyword: Thermal Resolution

Search Result 465, Processing Time 0.025 seconds

Local Flow Speed Measurement Using Tunable AC Thermal Anemometry

  • Chung Won Seok;Kwon Ohmyoung;Lee Joon Sik;Choi Young Ki;Park Seungho
    • Journal of Mechanical Science and Technology
    • /
    • v.19 no.7
    • /
    • pp.1449-1459
    • /
    • 2005
  • This paper shows the results of local flow speed measurement using tunable AC thermal anemometry, which is suitable for the accurate measurement of wide range flow speed. The measurement accuracy is verified through the comparison between the measurement data and the analytic solution of the sensor temperature oscillation in stationary fluid. The relation between the phase lag and the flow speed is experimentally investigated at various conditions. The measurement sensitivity for low flow speed improves in a low frequency region and that for high flow speed improves in a high frequency region. Also, the sensitivity increases with decreasing thermal conductivity of the surrounding fluid. The local flow speed could be measured as low as 1.5 mm/s and the highest measurement resolution was 0.05 mm/s in the range of 4.5 $\~$5.0 mm/s at 1 Hz in this experiment.

A Study on Effect of Improvement Plan for Wind Energy Forecasting (풍력 발전 예보 정확도 향상을 위한 국지 기상장 수치모의 개선 방안 연구)

  • Jung, Ji-A;Lee, Hwa-Woon;Jeon, Won-Bae;Kim, Dong-Hyeok;Kim, Hyun-Goo;Kang, Young-Heack
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.31 no.1
    • /
    • pp.1-14
    • /
    • 2015
  • This study investigates the impact of enhanced regional meteorological fields on improvement of wind energy forecasting accuracy in the southwestern coast of the Korean Peninsula. To clarify the effect of detailed surface boundary data and application of analysis nudging technique on simulated meteorological fields, several WRF simulations were carried out. Case_LT, which is a simulation with high resolution terrain height and land use data, shows the most remarkable accuracy improvement along the shoreline mainly due to modified surface characteristics such as albedo, roughness length and thermal inertia. Case_RS with high resolution SST data shows accurate SST distributions compared to observation data, and they led to change in land and sea breeze circulation. Case_GN, grid nudging applied simulation, also shows changed temperature and wind fields. Especially, the application of grid nudging dominantly influences on the change of horizontal wind components in comparison with vertical wind component.

A High-Resolution Heterodyne Interferometer using Beat Frequency between Two-Axial Modes of a HeNe Laser (2-종모드 레이저를 이용한 고분해능 헤테로다인 간섭계)

  • Kim, Min-Seok;Kim, Seung-Woo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.19 no.4
    • /
    • pp.195-201
    • /
    • 2002
  • We propose a new scheme of high-resolution heterodyne interferometer that employs the two-axial mode He-Ne laser with an inter-mode beat frequency of 600~1000 MHz. An electronic RF-heterodyne circuit lowers the beat frequency down to 5 MHz, so that the phase change of the interferometer output is precisely measured with a displacement resolution of 0.1 nanometer without significant loss of dynamic bandwidth. A thermal control scheme is adopted to stabilize the cavity length with ainus to suppress frequency drifts caused by the phenomena of frequency pulling and polarization anisotropy of the two-axial made laser to a stability level of 2 parts in $10^9$. The two-axial mode HeNe laser yields a high output power of 2.0 mW, which allows us to perform multiple measurements of up to 10 machine axes simultaneously.

Spatial Downscaling of MODIS Land Surface Temperature: Recent Research Trends, Challenges, and Future Directions

  • Yoo, Cheolhee;Im, Jungho;Park, Sumin;Cho, Dongjin
    • Korean Journal of Remote Sensing
    • /
    • v.36 no.4
    • /
    • pp.609-626
    • /
    • 2020
  • Satellite-based land surface temperature (LST) has been used as one of the major parameters in various climate and environmental models. Especially, Moderate Resolution Imaging Spectroradiometer (MODIS) LST is the most widely used satellite-based LST product due to its spatiotemporal coverage (1 km spatial and sub-daily temporal resolutions) and longevity (> 20 years). However, there is an increasing demand for LST products with finer spatial resolution (e.g., 10-250 m) over regions such as urban areas. Therefore, various methods have been proposed to produce high-resolution MODIS-like LST less than 250 m (e.g., 100 m). The purpose of this review is to provide a comprehensive overview of recent research trends and challenges for the downscaling of MODIS LST. Based on the recent literature survey for the past decade, the downscaling techniques classified into three groups-kernel-driven, fusion-based, and the combination of kernel-driven and fusion-based methods-were reviewed with their pros and cons. Then, five open issues and challenges were discussed: uncertainty in LST retrievals, low thermal contrast, the nonlinearity of LST temporal change, cloud contamination, and model generalization. Future research directions of LST downscaling were finally provided.

Pre-and Post-Curing of Readout Layer of Super Resolution Disc

  • Kim, Sun-Hee;Kwak, Keum-Cheol;Lee, Chang-Ho;Song, Ki-Chang
    • Transactions of the Society of Information Storage Systems
    • /
    • v.3 no.3
    • /
    • pp.113-117
    • /
    • 2007
  • 재생층이 상변화물질로 이루어진 초해상 광디스크에 있어서, 기록 전과 후에 thermal curing 을 실시하여 신호품질과 재생안정성이 크게 향상되었다. Pre-curing으로 수천 회 이하에서 나타나는 short-term stability가 향상되었고, post-curing 한 후 mid-term stability 가 향상되었다. 그리고, pre- and post-curing 후 noise level 은 전반적으로 $1{\sim}2dB$가 낮아졌고, CNR은 $2{\sim}3dB$, jitter 는 $2{\sim}3%$ 가 향상되었다.

  • PDF

REFOCUSING FOR ON-ORBIT MTF COMPENSATION OF REMOTE SENSING CAMERA

  • Jang Hong-Sul;Jeong Dae-Jun;Lee Seunghoon
    • Proceedings of the KSRS Conference
    • /
    • 2005.10a
    • /
    • pp.601-603
    • /
    • 2005
  • Refocusing methods are used to compensate optical performance degradation of high resolution satellite camera during on-orbit operation. Due to mechanical vibration during launch and thermal vacuum environment of space where camera is exposed, the alignment of optical system may have error. The focusing error is dominant of misalignment and caused by the de-space error of secondary mirror of catoptric camera, which is most sensitive to vibration and space environment. The high resolution camera of SPOT, Pleiades and KOMPSAT2 have refocusing device to adjust focusing during orbital operation while QuickBird of US does not use on orbit refocusing method. For the Korsch type optical configuration which is preferred for large aperture space remote sensing camera, secondary mirror and folding mirror are available as refocusing element.

  • PDF

Optimal Barrier Coating Processes to maximize the Alignment of Layers on Plastic Substrates

  • Lee, Woo-Jae;Hong, Mun-Pyo;Seo, Jong-Hyun;Rho, Soo-Guy;Hong, Wang-Su;Jeon, Hyung-Il;Kim, Sang-Il;Chung, Kyu-Ha
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2005.07b
    • /
    • pp.988-990
    • /
    • 2005
  • A 5.0-inch plastic TFT-LCD with the resolution of $400{\times}3{\times}300$ lines (120ppi) was developed. The device is a transmissive type with the transparent PES plastic substrates. The PES films with one side barrier coating were used for the device. In order to produce the high resolution display device, the alignments between all the layers for the TFT and CF are essential. The fundamental shrinkage effect and the thermal expansion behavior of the plastic substrates with and without the barrier coatings were studied. The proper annealing processes followed by immediate second bar-rier coating processes provide the optimal alignment between all the layers of the TFT and CF..

  • PDF

Temperature Measurement of Silicon Wafers Using Phase Estimation of Acoustic Wave (음향파의 위상 추정을 이용한 실리콘 웨이퍼의 온도 측정)

  • Joonhyuk Kang;Lee, Seokwon
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.52 no.11
    • /
    • pp.493-495
    • /
    • 2003
  • Accurate temperature measurement is a key factor to implement the rapid thermal processing(RTP). A temperature estimation method using acoustic wave has been proposed to overcome the inaccuracy and contamination problem of the previous methods. The proposed method, however, may suffer from the offset and low resolution problem since it is implemented in the time domain. This paper presents a temperature estimation method using the phase detection of acoustic wave. Based on the frequency domain approach, the proposed technique increases the resolution of the measured temperature and reduces the effect of noise. We investigate the performance of the proposed method via experiments.

Fiber Bragg grating sensor using a Mach-Zehnder interferometer (Mach-Zehnder 간섭계를 이용한 광섬유 브래그 격자 센서)

  • 송민호;이상배;최상삼;이병호
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.34D no.3
    • /
    • pp.105-113
    • /
    • 1997
  • We constructed a very accurate fiber bragg grating sensor system using an unbalanced mach-zehnder interferometer which converts the measurand-induced bragg wavelength shift to phase change of th einterference signal. With a shielded reference grating, output phase drift which orginates from the thermal drift on the interferometer was compensated. Mesured accuracy of the constructed system was 0.03 .deg. C and 0.26.mu. strain for temperature and strain measuremtn, respectively. It is over 300 times better resolution compared to the conventional optical spectrum analyzer which has 0.1nm wavelength resolution capability.

  • PDF

Partial Purification and Characterization of Thermostable Esterase from the Hyperthermophilic Archaeon Sulfolobus solfataricus

  • Chung Young Mi;Park Chan B.;Lee Sun Bok
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.5 no.1
    • /
    • pp.53-56
    • /
    • 2000
  • A thermostable esterase from the hyper thermophilic archaeon Sulfolobus solfataricus was partially purified 590-fold with $16.2\%$ recovery. The partially purified esterase had a specific activity of $29.5\;{\mu}mol\;min^{-1}mg^{-1}$ when the enzyme activity was determined using p-nitrophenyl butyrate as a substrate. The apparent molecular weight was about 100 kDa, while the optimum temperature and pH for esterase were $75^{\circ}C$ and 8.0, respectively. The enzyme showed high thermal stability and solvent tolerance in comparison to its mesophilic counterpart. The enzyme also showed chiral resolution activity for (S)-ibuprofen, indicating that S. solfataricus esterase can be used for the production of commercially important chiral drugs.

  • PDF