• Title/Summary/Keyword: Thermal Power Generation

Search Result 626, Processing Time 0.023 seconds

Analysis of Electrical Characteristics of Amorphous Silicon Thin Film Photovoltaic Module Exposed Outdoor (옥외 설치된 비정질 실리콘 박막태양전지모듈의 전기적 출력 특성 분석)

  • Kim, Kyung-Soo;Kang, Gi-Hwan;Yu, Gwon-Jong
    • Journal of the Korean Solar Energy Society
    • /
    • v.28 no.4
    • /
    • pp.62-67
    • /
    • 2008
  • In this study, we analyze the electrical characteristics of amorphous silicon thin film photovoltaic module which are installed about 5 years ago. Four modules from PV system are extracted and measured the maximum power change ratio using solar simulator(Class A). Also, infrared camera is used to get thermal distribution characteristics of system. The external appearance change is compared with initial module by naked eye examination. Through this experiment, 31% maximum output power drop is observed. The detail description is specified as the following paper.

Collaboration and Confucian Reflexivity in Local Energy Governance: The Case of Seoul's One Less Nuclear Power Plant Initiatives

  • Lee, Youhyun;Bae, Suho
    • Journal of Contemporary Eastern Asia
    • /
    • v.18 no.1
    • /
    • pp.153-174
    • /
    • 2019
  • South Korea's energy policy has been historically established through an energy production structure that relies on thermal and nuclear power generation in relation to a centralized 'Hard Energy System'. However, climate change issues are forcing the transition to renewable energy, and it is crucial for local governments to enable this. This study analyses Seoul city's local energy governance, which is known as One Less Nuclear Power Plant Initiative, by applying the collaborative governance framework inspired by Ansell and Gash (2008) and the Reflexivity framework of Confucianism. It is considered that the local energy governance model of Seoul city can be used as a model by other local governments, and it will eventually lead to a decentralized energy system in this era of energy transition.

Examination of the Cause of Damage to Capacitors for Home Appliances and Analysis of the Heat Generation Mechanism (가전용 커패시터의 소손원인 규명 및 발열 메커니즘 해석)

  • Park, Hyung-Ki;Choi, Chung-Seog
    • Journal of the Korean Society of Safety
    • /
    • v.26 no.6
    • /
    • pp.13-19
    • /
    • 2011
  • The purpose of this study is to examine the cause of damage to electrolytic capacitors and to present the heat generation mechanism in order to prevent the occurrence of similar problems. From the analysis results of electrolytic capacitors collected from accident sites, the fire causing area can be limited to the primary power supply for the initial accident. From the tests performed by applying overvoltage, surge, etc., it is thought that the fuse, varistor, etc., are not directly related to the accidents that occurred. The analysis of the characteristics using a switching regulator showed that the charge and discharge characteristics fell short of standard values. In addition, it is thought that heated electrolytic capacitors caused thermal stress to nearby resistances, elements, etc. It can be seen that the heat generation is governed by the over-ripple current, application of AC overvoltage, surge input, internal temperature increase, defective airtightness, etc. Therefore, when designing an electrolytic capacitor, it is necessary to comprehensively consider the correct polarity arrangement, appropriate voltage application, correct connection of equivalent series resistance(ESR) and equivalent series inductance(SEL), rapid charge and discharge control, sufficient margin of dielectric tangent, etc.

Performance Simulation of Motorcycle Engine Exhaust Heat Recovery System using Thermoelectric Element (열전소자를 이용한 모터사이클용 엔진 배기 폐열 회수 시스템 성능 해석)

  • Lee, Moo-Yeon;Kim, Kihyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.2
    • /
    • pp.695-701
    • /
    • 2018
  • Research into exhaust heat recovery has been actively carried out to improve the thermal efficiency of internal combustion engines. In this study, the performance of thermoelectric generation from exhaust heat recovery for motorcycle engines was analyzed by 1-D thermo-fluid simulation. GT-SUITE, which was developed by Gamma Tech., was used for the simulation of the internal combustion engine and thermoelectric generation system. The basic performance of the engine was analyzed in the range of engine speed of 1000~7000 rpm and engine load of 0~100%. The ratio of exhaust heat energy to fuel chemical energy was found to be about 40~60%. A combined simulation of the engine model and thermoelectric generation model was carried out to analyze the voltage, current and power generated by the thermoelectric material. The generation characteristics of the thermoelectric material was dominantly affected by the exhaust gas temperature. The maximum generated power of the current thermoelectric generation system was found to be about 2.2% of the total exhaust heat energy. The design optimization of the thermoelectric generation system will be carried out to maximize its power generation and economic feasibility.

An Experimental Study on LTD Stirling Engine (MM-7) for the Development of TM Electric Conversion System (TM발전변환기 개발을 위한 저온도차 스털링엔진(MM-7)의 성능실측 연구)

  • Kim, Yeongmin;Chen, Kuan;Chun, Wongee
    • Journal of Energy Engineering
    • /
    • v.25 no.1
    • /
    • pp.9-14
    • /
    • 2016
  • This study has been carried out to develop TM (Thermal to Mechanical) conversion systems for electric power generation using one of the Low Temperature Differential (LTD) Stirling engines called MM-7 capable of harnessing low temperature waste heat whose temperature is only $20{\sim}30^{\circ}C$ above the ambient. Measurements were made on the torque and rpm for a number of temperature differentials between the engine hot and cold ends, which could be effectively applied in developing the most suitable configuration for the high performance TM (Thermal to Mechanical) conversion system.

Thermal Conductivity and Dielectric Strength Measurement of the Impregnating Materials for the Next Generation Winding Type Superconducting Fault Current Limiter (차세대권선형한류기를 위한 함침용 재료의 열전도도 및 절연 내력 측정)

  • Yang Seong Eun;Bae Duck Kweon;Ahn Min Cheol;Kang Hyoung Ku;Seok Bok Yeol;Chang Ho Myung;Kim Sang Hyun;Ko Tae Kuk
    • Progress in Superconductivity and Cryogenics
    • /
    • v.7 no.1
    • /
    • pp.42-46
    • /
    • 2005
  • The resistive type high temperature superconducting fault current limiter (HTSFCL) limits the fault current using the resistance generated by fault current. The generated resistance by fault current makes large pulse power which makes the operation of HTSFCL unstable. So, the cryogenic cooling system of the resistive type HTSFCL must diffuse and eliminate the pulse energy very quickly. Although the best way is to make wide direct contact area between HTS winding and coolant as much as possible, HTS winding also needs the impregnation layer which fixes and protects it from electromagnetic force. This paper deals with the thermal conductivity and dielectric strength of some epoxy compounds for the impregnation of high temperature superconducting (HTS) winding in liquid nitrogen. The measured data can be used in the optimal design of impregnation for HTS winding. Aluminar filling increased the thermal conductivity of epoxy compounds. Hardener also affected the thermal and electric characteristic of epoxy compounds.

Estimation of C(t) -Integral Under Transient Creep Conditions for a Cracked Pipe Subjected to Combined Mechanical and Thermal Loads Depending on Loading Conditions (열응력 및 기계응력이 작용하는 균열배관의 하중조건에 따른 천이 크리프 조건 C(t)-적분 평가)

  • Oh, Chang-Young;Song, Tae-Kwang;Kim, Yun-Jae
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.35 no.6
    • /
    • pp.609-617
    • /
    • 2011
  • There is a trend towards the progressive use of higher operating temperatures and stresses to achieve improved efficiencies in power-generation equipment. It is important to perform the crack assessment under hightemperature and high-pressure conditions. The C(t)-integral is a key parameter in crack assessment for transient creep states. The estimation of the C(t)-integral is complex when considering the mechanical and thermal loads simultaneously. In this paper, we study estimation of C(t)-integral under combined mechanical and thermal load depending on loading conditions.

Operational Properties and Microbial Inactivation Performance of Dielectric Barrier Discharge Plasma Treatment System (유전체장벽방전 플라즈마 장치의 조작특성과 살균력)

  • Mok, Chulkyoon;Lee, Taehoon
    • Food Engineering Progress
    • /
    • v.15 no.4
    • /
    • pp.398-403
    • /
    • 2011
  • A dielectric barrier discharge plasma (DBDP) treatment system was fabricated and the optimum operating conditions for the plasma generation were determined in order to explore the potential of cold plasma as a non-thermal proessing technology. The microbial inactivation performance of the system was also evaluated against Staphyloocus aureus. The system consisted of power supply, transformer, electrode assembly and sample treatment plate. The input power was 220 V single phase AC and amplified to 10.0-50.0 kV on a transformer. A pulsed sine wave of frequency 10.0-50.0 kHz was introduced to the electrode embedded in ceramic as a dielectric barrier material in order to generate plasma at atmospheric pressure. Higher currents and consequently greater power were required for the plasma generation as the frequencies increased. A homogeneous and stable plasma was generated at currents of 1.0-2.0, and frequencies of 32.0-35.3 kHz. The optimum electrode-gaps for the plasma generation were 1.85 mm without loaded samples. More power was consumed as the electrode-gaps increased. The practically optimum electrode- gap was, however, 2.65 mm when samples were treated on slide-glasses for microbial inactivation. The maximum temperature increase after 10 min treatment was less than 20$^{\circ}C$, indicating no microbial inactivation effect by heat and thereby insuring a non-thermal method. The DBDP inactivation effect against Staphyloocus aureus increased linearly with treatment time up to 5 min, but plateaued afterward. More than 5 log reduction was achieved by 10 min treatment at 1.25 A.

Ancillary Service Requirement Assessment Indices for the Load Frequency Control in a Restructured Power System with Redox Flow Batteries

  • Chandrasekar, K.;Paramasivam, B.;Chidambaram, I.A.
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.6
    • /
    • pp.1535-1547
    • /
    • 2016
  • This paper proposes various design procedures for computing Power System Ancillary Service Requirement Assessment Indices (PSASRAI) for a Two-Area Thermal Reheat Interconnected Power System (TATRIPS) in a restructured environment. In an interconnected power system, a sudden load perturbation in any area causes the deviation of frequencies of all the areas and also in the tie-line powers. This has to be corrected to ensure the generation and distribution of electric power companies to ensure good quality. A simple Proportional and Integral (PI) controllers have wide usages in controlling the Load Frequency Control (LFC) problems. So the design of the PI controller gains for the restructured power system are obtained using Bacterial Foraging Optimization (BFO) algorithm. From the simulation results, the PSASRAI are calculated based on the settling time and peak over shoot concept of control input deviations of each area for different possible transactions. These Indices are useful for system operator to prepare the power system restoration plans. Moreover, the LFC loop coordinated with Redox Flow Batteries (RFB) has greatly improved the dynamic response and it reduces the control input requirements and to ensure improved PSASRAI, thereby improving the system reliability.