• Title/Summary/Keyword: Thermal Imaging

Search Result 626, Processing Time 0.029 seconds

Characterisation of Tensile Deformation through Infrared Imaging Technique

  • B. Venkataraman, Baldev Raj;Mukhophadyay, C.K.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.22 no.6
    • /
    • pp.609-620
    • /
    • 2002
  • It is well known that during tensile testing, a part of the mechanical work done on the specimen is transformed into heat energy. However, the ultimate temperature rise and the rate of temperature rise is related to the nature of the material, conditions of the test and also to the deformation behaviour of the material during loading. The recent advances in infrared sensors and image/data processing techniques enable observation and quantitative analysis of the heat energy dissipated during such tensile tests. In this study, infrared imaging technique has been used to characterise the tensile deformation in AISI type 316 nuclear grade stainless steel. Apart from identifying the different stages during tensile deformation, the technique provided an accurate full-field temperature image by which the point and time of strain localization could be identified. The technique makes it possible to visualise the region of deformation and failure and also predict the exact region of fracture in advance. The effect of thermal gradients on plastic flow in the case of interrupted straining revealed that the interruption of strain and restraining at a lower strain rate not only delays the growth of the temperature gradient, but the temperature rise per unit strain decreases. The technique is a potential NDE tool that can be used for on-line detection of thermal gradients developed during extrusion and metal forming process which can be used for ensuring uniform distribution of plastic strain.

Current on the Heat Loss in Greenhouses during Winter Season - Case Study Based on Gyeongnam Area - (동절기 온실의 열 손실에 관한 실태조사 - 경남지역을 중심으로 -)

  • Im, Jae Un;Yun, Sung Wook;Kim, Hyeon Tae;Yoon, Yong Cheol
    • Journal of Bio-Environment Control
    • /
    • v.22 no.1
    • /
    • pp.73-79
    • /
    • 2013
  • An experiment was conducted to study incidences of heat loss in greenhouse in Gyeongnam province using thermal imaging camera in order to determine ways minimizing greenhouse heat loss. Measurements of this work showed that temperature differences between two experiment zones before and after installation of thermal curtains were about $2.0{\sim}3.0^{\circ}C$ and $1.0{\sim}2.0^{\circ}C$ respectively. There was a high correlation between the temperature data measured using a thermal imaging camera and a temperature sensor. There was no serious difference among areas, but between places on the first and second floor with thermal curtains for heat insulation, there was a relatively larger heat loss on the first floor than the second floor. Then in general the greenhouse types had no particular bearing on this matter, there was a relatively large heat loss in the parts of side wall window, the gaps and the parts folded of horizontal thermal curtains, the gutter parts, and the gaps of thermal curtain in the side wall window and facade back side for heat insulation, aren't completely sealed. It was found that there was a substantial heat loss due to infiltration through cracks on covering material, doors, ventilating openings, roof gables and floors, in particular.

The Clinical Studies on the Irritable Syndrome by Using D.I.T.I. (과민성대장증후군(過敏性大腸症候群) 환자(患者)에 대한 적외선(赤外線) 체열영상촬영기기(體熱映像撮影器機)( D.I.T.I)의 응용연구)

  • Kim, Dal-Rae;Baik, Tai-Hyun
    • The Journal of Internal Korean Medicine
    • /
    • v.21 no.1
    • /
    • pp.7-12
    • /
    • 2000
  • Objectives : This studies were performed to investigate the correlation between the treatment effects and the changes of the thermal differences at the pre and post-treatment by using the digital infrared computer thermographic imaging (D.I.T.I) to the irritable colon syndrome 30 patients. Methods : The extracts of the gwakhyangjunggisan were administerd to the patients by oral method three times per day during four weeks. we selected the Chung-Wan($CV_{12}$), Chunchu($S_{25}$). Hapkok($LI_4$), Naegwan($P_6$), Yongdo($H_4$) acupoints and treated the patients two times per week during four weeks. One week later, we investigated the changes of the pressure pain around left side Pokkyol($SP_{14}$), the symptoms. and the skin temperature changes on Pokkyol($SP_{14}$) and Kimun($LR_{14}$) around, by using the D.I.T.I. Results : In the correlation between the severity of the pressure pain around left side Pokkyol($SP_{14}$) and the thermal differences on Pokkyol($SP_{14}$) and Kimun($LR_{14}$) around, before the treatment, the more the pain was severe, the more the skin temperature was differential significantly. In the correlation between the severity of the symptoms and the thermal differences on Pokkyol($SP_{14}$) and Kimun($LR_{14}$) around, before the treatment, the more the symptom was severe, the more the skin temperature was differential significantly. In the changes of the pressure pain around left side of Pokkyol($SP_{14}$), the improved were significantly higher than the unimproved. In the changes of the symptoms, the improved were significantly higher than the unimproved. In the correlation between the changes of the pressure pain around left side Pokkyol($SP_{14}$) and the changes of the thermal differences at the pre and post- treatment, the more the pain was improved, the more the thermal change was widened significantly. In the correlation between the changes of the symptoms and the changes of thermal differences at the pre and post-treatment, the more the symptom was improved. the more the thermal change was widened significantly. Conclusions : Above the results, the treatments was effective and the digital infrared computer thermographic imaging (D.I.T.I) was useful to prove the improvements of the pressure pain and the symptom with the irritable bowel syndrome patients.

  • PDF

Development of Smart-phone based Thermal Imaging Diagnostic System for Monitoring Disc Pads of Crane (크레인 디스크 패드 모니터링을 위한 스마트폰 기반의 열영상 진단 시스템 개발)

  • Oh, Yeon-Jae;Park, Kyoung-Wook;Kim, Eung-Kon
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.9 no.12
    • /
    • pp.1397-1404
    • /
    • 2014
  • Grab cranes are used for multi-purpose when the sand and soil are deposited into harbor wharf or the undersea construction is performed. Among the components of crane grab, the wire drum and disc brake pad are key expendables and have disadvantages that lot of heat is generated and very expensive when replacing them. In this study, the thermal image analysis for the disc brake, which works with wire drum of the crane is suggested. The suggested system performs the pad thermal diagnosis through the thermal image using the characteristics that the disc and pad surface temperatures are distributed abnormally before the brake failure and the disc pad damage. Therefore, the damage by the failure can be prevented by discovering the abnormality of the machine parts before failure and the life cycle of the pad and the cost can be extended and saved by operating the crane performing constant checkup for the overload.

Study on Grain Boundaries in Single-layer Graphene Using Ultrahigh Resolution TEM

  • Lee, Zong-Hoon
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.107-107
    • /
    • 2012
  • Recently, large-area synthesis of high-quality but polycrystalline graphene has been advanced as a scalable route to applications including electronic devices. The presence of grain boundaries (GBs) may be detrimental on some electronic, thermal, and mechanical properties of graphene, including reduced electronic mobility, lower thermal conductivity, and reduced ultimate mechanical strength, yet on the other hand, GBs might be beneficially exploited via controlled GB engineering. The study of graphene grains and their boundary is therefore critical for a complete understanding of this interesting material and for enabling diverse applications. I present that scanning electron diffraction in STEM mode makes possible fast and direct identification of GBs. We also demonstrate that dark field TEM imaging techniques allow facile GB imaging for high-angle tilt GBs in graphene. GB mapping is systematically carried out on large-area graphene samples via these complementary techniques. The study of the detailed atomic structure at a GB in suspended graphene uses aberration-corrected atomic resolution TEM at a low kV.

  • PDF

Temperature Measurement of Photovoltaic Modules Using Non-Contact Infrared System

  • Jovanovic, Ugljesa;Mancic, Dragan;Jovanovic, Igor;Petrusic, Zoran
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.2
    • /
    • pp.904-910
    • /
    • 2017
  • This paper presents temperature measurement of solar photovoltaic modules using the custom-made system composed of an infrared temperature sensor and a microcontroller. The obtained measurement results are processed, displayed and stored on a PC using the custom-made virtual instrument. The proposed system overcomes some of the problems related to the contact sensor application, and at the same time offers accurate readings and better flexibility. The proposed system is especially suitable for applications where the cost is a limiting factor in the choice of measuring system. The conducted analysis and the obtained results have shown an excellent accuracy of the proposed system in comparison to a high quality thermal imaging camera used as the reference instrument.

System Design of Sunshield on the MSC

  • Kim, Young-Soo;Lee, Eung-Shik;Woo, Sun-Hee
    • Proceedings of the KSRS Conference
    • /
    • 2002.10a
    • /
    • pp.815-820
    • /
    • 2002
  • MSC as a payload of KOMPSAT-2 is an optical telescope for earth imaging on a sun-synchronous orbit. The MSC is a Ritchey-Chretien type telescope composed of hyperbolic primary and secondary mirrors with focal correcting lenses. Their relative positions should be kept aligned during imaging operation. However, the MSC is exposed to adverse thermal environment on orbit which can have some impacts on optical performance as well as structural endurance. Solar incidence can cause non-uniform temperature rise on the tube which entails unfavorable thermal distortion. Three options were proposed, which were internal shield, external mechanical shield and spacecraft maneuvering. After the trade-off studies, internal sun shield was selected as a realistic and optimal solution to minimize the effect of the solar radiation. In this paper, pros and cons are explained for the three possible choices and a design of the internal shield is discussed.

  • PDF

Effect of Tracer Composition on Spectrum and Intensity of Burning Flame (예광제 조성이 연소 불꽃의 스펙트럼 및 광도에 미치는 영향)

  • Kwon, Soon-Kil;Hwang, Jun-Sik;Lee, Sang-Mu
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.9 no.4
    • /
    • pp.90-96
    • /
    • 2006
  • Computer simulation was carried out to develop the tracer composition of a high performance to be able to be observed by not only the naked eye but also the thermal imaging system attached to the weapon system. The results of computer simulation show that the optimum Mg content among the trace compositions is about 40% and the formulation consisted of Viton A has a higher flame temperature compared with that of chloride compound. But the only use of Viton A radiates a yellow light and the composition adding a chloride compound radiates the red light. The light intensity of the tracer composition involving Viton A is higher than that of chloride compound. The tracer composition involving Viton A shows more clear images in case of all tests.

Improvement Residual Non-uniformity in Thermal Imaging System Using Correlated Double Sample Signal Processing (상관이중표본화 신호처리를 이용한 적외선 열상시스템의 잔여불균일성 개선)

  • Suk, Jung-Youp;Jang, Sung-Kun;Kim, Sung-Un;Yeou, Bo-Yeoun
    • Proceedings of the IEEK Conference
    • /
    • 2008.06a
    • /
    • pp.1043-1044
    • /
    • 2008
  • In this study, a novel algorithm of the improvement residual non-uniformity (RNU) in thermal imaging system is proposed using correlated double sample signal processing. The proposed method attempts to eliminate offset variation of ROIC in IR detector causing the variation of FPA (focal plane array) temperature and suppling power. Experimental results show that the proposed method confirmed a better performance than the existing RNU system.

  • PDF

Clinical Observation on 1 Case of Both Leg Paralysis Patient Diagnosed Wei Symptom (위증(療證)으로 진단한 하지마비 환자의 치험 1례)

  • Wei, Tung-Sheun
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.20 no.3
    • /
    • pp.748-752
    • /
    • 2006
  • Wei symptom(?證) is symptom that reveals muscle relaxation without contraction and muscle relaxation occurs in the lower or upper limb, in severe case, leads to death. This is the clinical report about the Wei symptom(?證)-patient doubt as Transverse Myelitis and Conversion Disorder. The patient was treated by acupuncture, moxibustion, herb medication(十全大補湯), electriccal stimulation theraphy, Bee Venom acupuncture, and had significant improvement in Wei symptom(?證). these results suggest the surface temperature differ remarkably from before being treated. The temperature is measured by using Digital Infrared Thermal Imaging(DITI). The results suggest that oriental medicare is an effective treatment for Wei symptom. We expected that therapeutic value of treatment of both leg Paralysis in the oriental medicine will be higher if more clinical studies and researches are accomplished.