• 제목/요약/키워드: Thermal Experiment

검색결과 1,935건 처리시간 0.035초

Numerical Simulation and Experiment of Pressure Pulsation in Kaplan Turbine

  • Yang, Wei;Wu, Shangfeng;Liu, Shuhong;Wu, Yulin
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2008년 영문 학술대회
    • /
    • pp.729-731
    • /
    • 2008
  • Three-dimensional unsteady simulation using RNG $\kappa-\varepsilon$ turbulence model is used in full flow passage of model Kaplan turbine. Then the pressure pulsation is obtained. Monitoring data of pressure pulsation in the turbine is obtained through experiment and is compared with the numerical simulation. And a good coherence is shown between the simulation and the experiment. Then the regularity of the pressure pulsation s distribution and transmission in the turbine is discussed in detail.

  • PDF

Insights into fuel behaviour during relatively fast thermal transients based on calculations for two tests of the Halden IFA-507 experiment

  • Grigori Khvostov
    • Nuclear Engineering and Technology
    • /
    • 제55권10호
    • /
    • pp.3801-3807
    • /
    • 2023
  • Outcomes of the project "Comprehensive Verification of the FALCON Code for Calculation of Nuclear Fuel Temperature" relating to calculation of fuel temperature during relatively fast thermal transients are presented. Good prediction capabilities of the FALCON MOD01 code coupled with the GRSW-A code are shown as applied to the data of the TF3 and TF5 tests from the Transient Temperature Experiment IFA-507. The IFA-507 related dataset of the OECD/NEA International Fuel Performance Experiments (IFPE) Database is extended by the reconstructed dynamics of the axial power distribution in the rods during the transient phase of the experiment. Based on the code calculation, the time constant of the thermal fuel response to a power transient is estimated.

용사에 의한 페라이트 자성재료 코팅의 .전자파 차폐특성 (Characteristic of Electromagnetic Wave Shielding Coatings by Thermal Spray)

  • 정태식;박경채
    • 대한용접접합학회:학술대회논문집
    • /
    • 대한용접접합학회 2000년도 특별강연 및 추계학술발표대회 개요집
    • /
    • pp.240-242
    • /
    • 2000
  • This study was investigated absorption properties of electromagnetic wave in thermal sprayed Sr-ferrite coatings. The experiment of this study was ; manufactured thermal spraying powder for improving absorption-efficiency, processed for increasing strength of thermal spray coatings, and measured the electromagnetic wave shielding efficiency. This study was obtained excellent absorption-efficiency by thermal sprayed Sr-ferrite coatings.

  • PDF

변동환경 대응을 위한 난방System의 쾌적 알고리즘 개발 (Development of comfort algorism for Indoor temperature chagne in Heating System)

  • 김동규;정용현;금종수
    • 수산해양교육연구
    • /
    • 제18권3호
    • /
    • pp.229-235
    • /
    • 2006
  • This study investigated physiology and psychological response of subjects, when heat pump was operated long time within comfort temperature range. Eight subjects were participated for the experiment. Their age was from 22 to 25 years old. The results of this experiment will propose basic data for improving comfort control algorithm in fluctuating environment by using heat pump. When indoor temperature was controlled by heat pump, the conclusion was as follows. 1) When votes of subjects was considered, the thermal comfort neutrality or lower range helped formation of comfort sensation for subjects. 2) When room temperature was lower, thermal comforts of shoulder, knee and foot with subjects thermal comfort showed high correlation. And when room temperature was higher, thermal comfort of face region with subjects thermal comfort showed high correlation. 3) The necessity of temperature change after 50 minutes from initially operating heat pump demands the additional analysis against the physiological signal.

파카의 보온성에 따른 착용감에 관한 연구 (The Effects of Parka on Subject Wear Sensation as to Thermal Resistance)

  • 이윤정;이순원
    • 한국의류학회지
    • /
    • 제13권3호
    • /
    • pp.295-303
    • /
    • 1989
  • This study is to measure the thermal resistance of 7 types of Parka of different materials with thermal manikin and to compare their effects on physiological responses & subjective wear sensations. Following are the results obtained from the experiments 1) From the thermal manikin experiment, i) As an outer layer, although not significant, water proof fabric was warmer than water proof-vapor permeable fabric. ii) In case of insulating material, down was better for thermal resistance than polyester wadding of the same thickness. Moreover, as the down was thicker, it had more efficiency in thermal resistance. However, the marginal efficiency of thickness was found to be decreasing. 2) From the male-subject experiments, i) Chest temperature, mean skin temperature & microclimate temperature showed the same results on thermal resistance as those of the thermal manikin experiment. ii) Only during rest periods, there was a significant difference among 5 insulating materials in the sense of microclimate humidity. The almost same conclusion was obtained from the above experiments. Even the outer layer did not significantly affect thermal resistance & subjective wear sensation, insulating materials had a significant influence upon them. But in case of 3.5 cm down, it gave less comfortable than that of the thinner. Therefore the optional one for the best comfort & thermal resistance among 7 combinatins is the outer layer of water proff-vapor permeable & insulating material of 2.1 cm down.

  • PDF

커튼월 스팬드럴용 진공유리의 열파손에 대한 비교실험 (A Comparative Experiment on Thermal Stress Failure of Vacuum Glazing applied in Curtain Wall at Spandrel area)

  • 김승철;윤종호;신우철;안정혁
    • KIEAE Journal
    • /
    • 제16권3호
    • /
    • pp.121-128
    • /
    • 2016
  • Purpose: The vacuum glazing should constantly retain the gap in vacuum state to maintain high thermal performance. To do so, pillars are used to prevent the glazing from clinging to each other by the atmospheric pressure and therefore surface of the vacuum glazing is consistently affected by residual stress. The vacuum glazing could be applied to curtain wall systems at spandrel area to fulfill a rigorous domestic standard on U-value of the external wall. However, this can lead to high glazing temperature increase by heat concentration at a back panel and finally thermal stress breakage. This study experimentally determined weakness of the vacuum glazing systems on the thermal stress breakage and investigated effect of the residual stress. Method: The experiment first built two scale-down mock-up facilities that replicate the spandrel area in curtain wall, and then installed single low-e glass and vacuum glazing respectively. The two mock-up facilities were exposed to outside to induce the thermal stress breakage. Result: The experiment showed that the temperature occurred the thermal stress breakage was $114.4^{\circ}C$ for the single low-e glass and $118.9^{\circ}C$ for the vacuum glazing respectively. The result also showed the vacuum glazing reached the critical point earlier than the single low-e glass, which means that the vacuum glazing has high potential to occur the thermal shock breakage. In addition, the small temperature difference between two glazing indicates that the residual stress scarcely affects breakage of the vacuum glazing.

운동복의 기능성과 쾌적성에 관한 연구 (Sportswear Physiological Optimization: Effects of Clothing ease, local heating and materiales)

  • 이영숙;안태환
    • 한국의류학회지
    • /
    • 제15권2호
    • /
    • pp.127-138
    • /
    • 1991
  • The aim of the present stud)r has been to obtain new and additional data allolwing a better design of sports garments as well as a better choice among some materiales, through measure-ment of body surface changes in the upper trunk in movement, measurement on the effects of local heating on other parts of the body and measurement of the thermal resistance of 6 types of materials applied on a manikin. In the first experiment, the upper trunk was divided in 32 Parts, the surface of which was measured by the tape method for two upper limb positions: extension at $90^{\circ}$ and $180^{\circ}$. In the second experiment, skin temperature, local thermal sensations and whole body thermal sensation were measured every 5 minutes during 40 minutes. The four areas of the shoulder, abdomen, hande and feet were heated with the hot pack at $50^{\circ}C$. In the third experiment, the regional thermal resistance of the various materials selected, in two different cases of clothing ease, have been measured by using a thermal manikin. Resultes of experiments were: 1. Extensions cause the upper front part of the trunk surface to lengthen vertically while the back tends to stretch in width. 2. Skin temperatures of the upper limbs are influenced by the abdomen and shoulder boatings. The correlation between the whole body thermal sensation and the upper trunk thermal sensation is significantly asserted. 3. Ceramic and aluminium coated materiales offer the most effective thermal resistance; ease in clothing increases the thermal resistance at the breast and the abdomen as well as the clo value of the materials.

  • PDF

액체식 PV/Thermal 복합모듈의 성능실험연구 (An Experimental Study of a Water Type PV/Thermal Combined Collector Unit)

  • 이현주;김진희;김준태
    • 한국태양에너지학회 논문집
    • /
    • 제27권4호
    • /
    • pp.105-111
    • /
    • 2007
  • Hybrid PV/Thermal systems consisting of photovoltaic module and thermal collector can produce the electricity and thermal energy. The solar radiation increases the temperature of PV modules, resulting in the decrease of their electrical efficiency. Accordingly hot air can be extracted from the space between the PV panel and roof, so the efficiency of the PV module increases. The extracted thermal energy can be used in several ways, increasing the total energy output of the system. This study describes a basic type of PV/T collector using water. In order to analyze the performance of the collector, the experiment was conducted. The result showed that the thermal efficiency was 17% average and the electrical efficiency of the PV module was about $10.2%{\sim}11.5%$, both depending on solar radiation, inlet water temperature and ambient temperature.

Optimization of arc brazing process parameters for exhaust system parts using box-behnken design of experiment

  • Kim, Yong;Park, Pyeong-Won;Park, Ki-Young;Ryu, Jin-Chul
    • Journal of Welding and Joining
    • /
    • 제33권2호
    • /
    • pp.23-31
    • /
    • 2015
  • Stainless steel is used in automobile muffler and exhaust systems. However, in comparison with other steels it has a high thermal expansion rate and low thermal conductivity, and undergoes excessive thermal deformation after welding. To address this problem, we evaluated the use of arc brazing in place of welding for the processing of an exhaust system, and investigated the parameters that affect the joint characteristics. Muffler parts STS439 and hot-dipped Al coated steel were used as test specimens, and CuAl brazing wire was used as the filler metal for the cold metal transfer (CMT) welding machine, which is a low heat input arc welder. In addition, a Box-Behnken design of experiment was used, which is a response surface methodology. The main process parameters (current, speed, and torch angle) were used to determine the appropriate welding quality and the mechanical properties of the brazing part was evaluated at the optimal welding condition. The optimal processing condition for arc brazing was 135A current, 51cm/min speed and $74^{\circ}$ torch angle. The process was applied to an actual exhaust system muffler and the prototype was validated by thermal fatigue, thermal shock, and endurance limit tests.

알루미늄 열용사 코팅된 AA5083-H321의 내식성 평가 (Corrosion Resistance Evaluation of Aluminum Thermal Spray Coated AA5083-H321)

  • 박일초;김성준;한민수
    • Corrosion Science and Technology
    • /
    • 제22권2호
    • /
    • pp.108-114
    • /
    • 2023
  • In this study, anti-corrosion effect was investigated through various electrochemical experiments after applying Al thermal spraying technology to AA5083-H321. Open circuit potential and anodic polarization curves were analyzed through electrochemical experiments in natural seawater. The shape of the surface was observed using a scanning electron microscope (SEM) and a 3D microscope before and after the experiment. Component and crystal structure were analyzed through EDS and XRD. As a result, the surface roughness of AA5083-H321 and the Al thermal sprayed coating layer increased due to surface damage caused by anodic dissolution reaction during the anodic polarization experiment. The corrosion rate of AA5083-H321 was relatively low because the Al thermal spray coating layer contained structural defects such as pores and crevices. Nevertheless, the open circuit potential of the Al thermal spray coating layer in natural seawater was measured about 0.2 V lower than that of AA5083-H321. Thus, a sacrificial anode protection effect can be expected.