• Title/Summary/Keyword: Thermal Electric

Search Result 1,754, Processing Time 0.028 seconds

Effects of SrTiO3-Modification on the Dielectric and Electromechanical Strain Properties of Lead-Free Bi1/2Na1/2TiO3-BiAlO3 Piezoceramics (Bi1/2Na1/2TiO3-BiAlO3 무연 압전 세라믹스의 유전 및 전기 기계적 변형 특성에 대한 SrTiO3 첨가 효과)

  • Lee, Sang Sub;Lee, Chang-Heon;Duong, Trang An;Kim, Dong Hyeok;Kim, Byeong Woo;Han, Hyoung-Su;Lee, Jae-Shin
    • Korean Journal of Materials Research
    • /
    • v.31 no.10
    • /
    • pp.562-568
    • /
    • 2021
  • (Bi1/2Na1/2)TiO3 (BNT)-based ceramics are considered promising candidates for actuator application owing to their excellent electromechanical strain properties However, to obtain large strain properties, there remain several issues such as thermal stability and high operating fields. Therefore, this study investigates a reduction of operating field in (0.98-x)Bi1/2Na1/2TiO3-0.02 BiAlO3-xSrTiO3 (BNT-2BA-100xST, x = 0.20, 0.21, 0.22, 0.23, and 0.24) via analyses of the microstructure, crystal structure, dielectric, polarization, ferroelectric and electromechanical strain properties. The average grain size of BNT-${\underline{2}}$BA-100xST ceramics decreases with increasing ST content. Results of polarization and electromechanical strain properties indicate that a ferroelectric to relaxor state transition is induced by ST modification. As a consequence, a large electromechanical strain of 592 pm/V is obtained at a relatively low electric field of 4 kV/mm in 22 mol% ST-modified BNT-2BA ceramics. We believe that the materials synthesized in this study are promising candidates for actuator applications.

Discovering the Knowledge Structure of Graphene Technology by Text Mining National R&D Projects and Newspapers (국가R&D과제와 신문에서 텍스트마이닝을 통한 그래핀 기술의 지식구조 탐색)

  • Lee, Ji-Yeon;Na, Hye-In;Lee, Byeong-Hee;Kim, Tae-Hyun
    • The Journal of the Korea Contents Association
    • /
    • v.21 no.2
    • /
    • pp.85-99
    • /
    • 2021
  • Graphene, called the "dream material" is drawing attention as a groundbreaking new material that will lead the era of the 4th Industrial Revolution. Graphene has high strength, excellent electrical and thermal conductivity, excellent optical permeability, and excellent gas barrier properties. In this paper, as the South Korean government recently announced Green New Deal and Digital New Deal policy, we analyze graphene technology, which is also attracting attention for its application to Corona 19 biosensor, to understand its national R&D trend and knowledge structure, and to explore the possibility of its application. Firstly, 4,054 cases of national R&D project information for the last 10 years are collected from the National Science & Technology Information Service(NTIS) to analyze the trend of graphene-related R&D. Besides, projects classified as green technology are analyzed concerning the government's Green New Deal policy. Secondly, text mining analysis is conducted by collecting 500 recent graphene-related articles from e-newspapers. According to the analysis, the field with the largest number of projects was found to be high-efficiency secondary battery technology, and the proportion of total research funds was also the highest. It is expected that South Korea will lead the development of graphene technology in the future to become a world leader in diverse industries including electric vehicles, cellular phone batteries, next-generation semiconductors, 5G, and biosensors.

Addition of 2 mg dexamethasone to improve the anesthetic efficacy of 2% lidocaine with 1:80,000 epinephrine administered for inferior alveolar nerve block to patients with symptomatic irreversible pulpitis in the mandibular molars: a randomized double-blind clinical trial

  • Aggarwal, Vivek;Ahmad, Tanveer;Singla, Mamta;Gupta, Alpa;Saatchi, Masoud;Hasija, Mukesh;Meena, Babita;Kumar, Umesh
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.22 no.4
    • /
    • pp.305-314
    • /
    • 2022
  • Introduction: This clinical trial aimed to evaluate the anesthetic effect of the addition of 2 mg (4 mg/ml) of dexamethasone to 2% lidocaine (plain or with 1:80,000 epinephrine). The solutions were injected for a primary inferior alveolar nerve block (IANB) to provide mandibular anesthesia for the endodontic treatment of mandibular molars with symptomatic irreversible pulpitis. Methods: In a double-blinded setup, 124 patients randomly received either of the following injections: 2% lidocaine with 1:80,000 epinephrine, 2% lidocaine with 1:80,000 epinephrine mixed with 2 mg dexamethasone, or plain 2% lidocaine mixed with 2 mg dexamethasone, which were injected as a primary IANB. Ten minutes after injection, patients with profound lip numbness underwent electric and thermal pulp sensibility tests. Patients who responded positively to the tests were categorized as "failed" anesthesia and received supplemental anesthesia. The remaining patients underwent endodontic treatment using a rubber dam. Anesthetic success was defined as "no pain or faint/weak/mild pain" during endodontic access preparation and instrumentation (HP visual analog scale score < 55 mm). The effect of the anesthetic solutions on the maximum change in heart rate was also evaluated. The Pearson chi-square test at 5% and 1% significance was used to analyze anesthetic success rates. Results: The 2% lidocaine with 1:80,000 epinephrine, 2% lidocaine with 1:80,000 epinephrine mixed with 2 mg dexamethasone, and plain 2% lidocaine mixed with 2 mg dexamethasone groups had anesthetic success rates of 34%, 59%, and 29%, respectively. The addition of dexamethasone resulted in significantly better results (P < 0.001, 𝛘2 = 9.07, df = 2). Conclusions: The addition of dexamethasone to 2% lidocaine with epinephrine, administered as an IANB, can improve the anesthetic success rates during the endodontic management of symptomatic mandibular molars with irreversible pulpitis.

Development trends of Solar cell technologies for Small satellite (소형위성용 태양전지 개발 동향 및 발전 방향)

  • Choi, Jun Hee
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.5
    • /
    • pp.310-316
    • /
    • 2021
  • Conventional satellites are generally large satellites that are multi-functional and have high performance. However, small satellites have been gradually drawing attention since the recent development of lightweight and integrated electric, electronic, and optical technologies. As the size and weight of a satellite decrease, the barrier to satellite development is becoming lower due to the cost of manufacture and cheaper launch. However, solar panels are essential for the power supply of satellites but have limitations in miniaturization and weight reduction because they require a large surface area to be efficiently exposed to sunlight. Space solar cells must be manufactured in consideration of various space environments such as spacecraft and environments with solar thermal temperatures. It is necessary to study structural materials for lightweight and high-efficiency solar cells by applying an unfolding mechanism that optimizes the surface-to-volume ratio. Currently, most products are developed and operated as solar cell panels for space applications with a triple-junction structure of InGaP/GaAs/Ge materials for high efficiency. Furthermore, multi-layered junctions have been studied for ultra-high-efficiency solar cells. Flexible thin-film solar cells and organic-inorganic hybrid solar cells are advantageous for material weight reduction and are attracting attention as next-generation solar cells for small satellites.

Heating Characteristics of Carbon Fiber Polyimide-Coated by Electrophoretic Deposition (전기영동증착법으로 폴리이미드를 코팅한 탄소섬유의 발열 특성 연구)

  • Geon-Joo Jeong;Tae-Yoo Kim;Seung-Boo Jung;Kwang-Seok Kim
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.30 no.1
    • /
    • pp.90-94
    • /
    • 2023
  • Carbon fiber(CF) with excellent thermal conductivity and electrical conductivity is attracting attention as an alternative material because metal heating elements have problems such as high heat loss and fire risk. However, since CF is oxidized and disconnected at about 200℃ or higher, the application of heating elements is limited, and CF heating elements in the form of vacuum tubes are currently used in some commercial heaters. In this work, polyimide(PI) with high heat resistance was coated on the surface of carbon fiber by electrophoretic deposition to prevent oxidation of CF in the atmosphere without using a vacuum tube, and the coating thickness and heat resistance were investigated according to the applied voltage. The heater made by connecting the PI-coated CF heating elements in series showed stable heating characteristics up to 292℃, which was similar to the heating temperature result of the heat transfer simulation. The PI layer coated by the electrophoretic deposition method is effective in preventing oxidation of CF at 200℃ or higher and is expected to be applicable to various heating components such as secondary batteries, aerospace, and electric vehicles that require heat stability.

Measurement and Prediction of Combustion Characteristics of DEC(Diethyl Carbonate) + DMMP(Dimethyl Methylphosphonate) for Secondary Battery Solutions (2차전지 용액인 DEC(Diethyl Carbonate) + DMMP(Dimethyl Methylphosphonate)계의 연소특성치 측정 및 예측)

  • Y. S. Jang;Y. R. Jang;J. J. Choi;D. J. Jeon;Y. G. Kim;D. M. Ha
    • Journal of the Korean Society of Safety
    • /
    • v.38 no.5
    • /
    • pp.8-14
    • /
    • 2023
  • Lithium ions can induce the thermal runaway phenomenon and lead to reignition due to electrical, mechanical, and environmental factors such as high temperature, smoke generation, explosions, or flames, which is extremely likely to create safety concerns. Therefore, one of the ways to improve the flame retardancy of the electrolyte is to use a flame-retardant additive. Comparing the associated characteristic value of existing substances with the required experimental value, it was found that these values were either considerably different or were not documented. It is vital to know a substance's combustion characteristic values, flash point, explosion limit, and autoignition temperature (AIT) as well as its combustion characteristics before using it. In this research, the flash point and AIT of materials were measured by mixing a highly volatile and flammable substance, diethyl carbonate (DEC), with flame-retardant dimethyl methylphosphonate (DMMP). The flash point of DEC, which is a pure substance, was 29℃, and that for DMMP was 65℃. Further, the lower explosion limit calculated using the measured flash point of DEC was 1.79 Vol.%, while that for DMMP was 0.79 Vol.%. The AIT was 410℃ and 390℃ for DEC and DMMP, respectively. In particular, since the AIT of DMMP has not been discussed in any previous study, it is necessary to ensure safety through experimental values. In this study, the experimental and regression analysis revealed that the average absolute deviation (ADD) for the flash point of the DEC+DMMP DEC+DMMP system is 0.58 sec and that the flash point tends to increase according to changes in the composition employed. It also revealed that the AAD for the AIT of the mixture was 3.17 sec and that the AIT tended to decrease and then increase based on changes in the composition.

MEASUREMENT OF PULPAL BLOOD FLOW USING A LASER DOPPLER FLOWMETER (Laser Doppler flowmeter를 이용한 치수혈류 측정)

  • Ban, Tae-Whan;Lee, Jae-Sang;Kim, Sung-Kyo
    • Restorative Dentistry and Endodontics
    • /
    • v.24 no.4
    • /
    • pp.560-569
    • /
    • 1999
  • Blood supply rather than nerve supply implies pulp vitality. To evaluate pulp vitality clinically, electric pulp test and thermal test which are based on sensory nerve response have been used in addition to many auxiliary data such as past dental history, visual inspection, radiographic examination, percussion, palpation and transillumination test. However, reactivity of the nerves to the stimulation is not synonymous with normalcy. Therefore measurement of pulpal blood flow using a laser Doppler flowmeter became a new trial to test the pulp vitality. The purpose of the present study was to evaluate normal pulpal blood flow level of maxillary teeth in adult to provide a guideline in determining the vitality of dental pulp. Pulpal blood flow was measured in maxillary central and lateral incisors, canines, first and second premolars and first molars of seventy nine adults of 22 - 30 years old using a laser Doppler flowmeter (PeriFlux 4001, Perimed Co., Stockholm, Sweden, 780 nm infrared laser, 1mW). For directly-made splints, silicone rubber impressions were taken directly from the mouth. For indirectly-made splints, alginate impressions were taken from the mouth and stone cast were made. After making depressions on the buccal surfaces of the cast teeth to indicate the hole positions, second impressions with vinyl polysyloxane putty were taken from the cast. Holes for the laser probes were made at the putty impressions 4mm above the gingival level. Laser probe (PF416 dental probe, 1.5mm) was inserted in the prepared hole and the splint was set in the mouth. After 10 minutes of patient relaxing, pulpal blood flow was recorded for 5 minutes on each tooth. The recorded flow was saved in the computer and calculated with a software 'Perisoft' version 5.1. Pulpal blood flow was also recorded in six teeth of five individuals with no response to electric pulp test and cold test, with periapical radiolucency, or with history of root canal treatment to compare with nonvital teeth. The difference between the mean flow values of each group of teeth were analyzed using one-way ANOVA and Duncan's Multiple Range test. The results were as follows: 1. The average pulpal blood flow values of all the tested teeth of each location were between 9 - 16 Perfusion Unit. Pulpal blood flow value was highest in maxillary lateral incisors, followed by first premolars, second premolars, canines, central incisors, and then first molars (p<0.01). 2. In six anterior teeth, indirectly-made splint group showed higher pulpal blood flow values than directly-made splint group (p<0.01). In posterior teeth, however, there was no significant flow value difference between directly-made splint group and indirectly-made splint one (p>0.05). 3. Teeth with vital pulps showed higher signal values than teeth with nonvital pulps (p<0.01), and the flow photographs showed heartbeat-synchronous fluctuations and vasomotions, while those were absent in non vital tooth.

  • PDF

Energy Saving Effect for High Bed Strawberry Using a Crown Heating System (고설 딸기 관부 난방시스템의 에너지 절감 효과)

  • Moon, Jong Pil;Park, Seok Ho;Kwon, Jin Kyung;Kang, Youn Koo;Lee, Jae Han;Kim, Hyung Gweon
    • Journal of Bio-Environment Control
    • /
    • v.28 no.4
    • /
    • pp.420-428
    • /
    • 2019
  • This study is the heating energy saving test of the high-bed strawberry crown heating system. The system consists of electric hot water boiler, thermal storage tank, circulation pump, crown heating pipe(white low density polyethylene, diameter 16mm) and a temperature control panel. For crown heating, the hot water pipe was installed as close as possible to the crown part after planting the seedlings and the pipe position was fixed with a horticultural fixing pin. In the local heating type, hot water at $20{\sim}23^{\circ}C$ is stored in the themal tank by using an electric hot water boiler, and crown spot is partially heated at the setting temperature of $13{\sim}15^{\circ}C$ by turning on/off the circulation pump using a temperature sensor for controlling the hot water circulation pump which was installed at the very close to crown of strawberry. The treatment of test zone consisted of space heating $4^{\circ}C$ + crown heating(treatment 1), space heating $8^{\circ}C$(control), space heating $6^{\circ}C$ + crown heating(treatment 2). And strawberries were planted in the number of 980 for each treatment. The heating energy consumption was compared between November 8, 2017 and March 30, 2018. Accumulated power consumption is converted to integrated kerosene consumption. The converted kerosene consumption is 1,320L(100%) for space $8^{\circ}C$ heating, 928L(70.3%) for space $4^{\circ}C$ + crown heating, 1,161L($88^{\circ}C$) for space $6^{\circ}C$ + crown heating). It was analyzed that space $4^{\circ}C$ + pipe heating and space $6^{\circ}C$ + crown heating save heating energy of 29.7% and 12% respectively compared to $8^{\circ}C$ space heating(control).

Development of Electret to Improve Output and Stability of Triboelectric Nanogenerator (마찰대전 나노발전기의 출력 및 안정성 향상을 위한 일렉트렛 개발)

  • Kam, Dongik;Jang, Sunmin;Yun, Yeongcheol;Bae, Hongeun;Lee, Youngjin;Ra, Yoonsang;Cho, Sumin;Seo, Kyoung Duck;Cha, Kyoung Je;Choi, Dongwhi
    • Korean Chemical Engineering Research
    • /
    • v.60 no.1
    • /
    • pp.93-99
    • /
    • 2022
  • With the rapid development of ultra-small and wearable device technology, continuous electricity supply without spatiotemporal limitations for driving electronic devices is required. Accordingly, Triboelectric nanogenerator (TENG), which utilizes static electricity generated by the contact and separation of two different materials, is being used as a means of effectively harvesting various types of energy dispersed without complex processes and designs due to its simple principle. However, to apply the TENG to real life, it is necessary to increase the electrical output. In addition, stable generation of electrical output, as well as increase in electrical output, is a task to be solved for the commercialization of TENG. In this study, we proposed a method to not only improve the output of TENG but also to stably represent the improved output. This was solved by using the contact layer, which is one of the components of TENG, as an electret for improved output and stability. The utilized electret was manufactured by sequentially performing corona charging-thermal annealing-corona charging on the Fluorinated ethylene propylene (FEP) film. Electric charges artificially injected due to corona charging enter a deep trap through the thermal annealing, so an electret that minimizes charge escape was fabricated and used in TENG. The output performance of the manufactured electret was verified by measuring the voltage output of the TENG in vertical contact separation mode, and the electret treated to the corona charging showed an output voltage 12 times higher than that of the pristine FEP film. The time and humidity stability of the electret was confirmed by measuring the output voltage of the TENG after exposing the electret to a general external environment and extreme humidity environment. In addition, it was shown that it can be applied to real-life by operating the LED by applying an electret to the clap-TENG with the motif of clap.

A Study on the Extraction of Monasil PCA using Liquid CO2 (액체 이산화탄소 이용한 Monasil PCA 추출에 대한 연구)

  • Cho, Dong Woo;Oh, Kyoung Shil;Bae, Won;Kim, Hwayong;Lee, Kab-Soo
    • Korean Chemical Engineering Research
    • /
    • v.50 no.4
    • /
    • pp.684-689
    • /
    • 2012
  • Poly(acrylic acid) (PAA) microspheres is one of the widely-used polymeric materials for the bio-field application and the electric materials. For the synthesis of PAA microspheres, the polymerization technique using surfactants is applied. After the synthesis, the purification and separation processes are required for the removal of surfactant. When general organic solvents were used, many problems, such as huge amount of waste solvent, additional separation processes, and the possibility of residual media, were occurred. Thus, High-pressure Soxhlet extraction using liquid $CO_2$ was developed to solve these problems. In this study, High-pressure Soxhlet extraction of the synthesized PAA microspheres using liquid $CO_2$ was conducted for the removal of Monasil PCA which is used for the dispersion polymerization of acrylic acid in compressed liquid Dimethyl ether (DME). The morphology of the extracted PAA particles was checked by field emission scanning electron microscopy (FE-SEM) and the residual concentration of Monasil PCA was analyzed by inductively coupled plasma - Optical Emission Spectrometer (ICP-OES). For studying the effect of the solvent effect, Soxhlet extraction was conducted using n-hexane, liquid DME, and liquid $CO_2$. In case of n-hexane, some extracted PAA microspheres were produced. However, deformation was also occurred due to the high thermal energy of n-hexane vapor. Liquid DME could not remove Monasil PCA. When using liquid $CO_2$, the extracted PAA microspheres which were free for the residual solvent were produced without deformation. For finding the optimum operating condition, high-pressure Soxhlet extraction was conducted for 8 hours with changing the temperature of reboiler and condenser. When the extractor temperature is $19.6{\pm}0.2^{\circ}C$ and the pressure is $51.5{\pm}0.5$ bar, the best removal efficiency was obtained.