• Title/Summary/Keyword: Thermal Displacement

Search Result 507, Processing Time 0.027 seconds

Examination of Airflow and Thermal Environment Characteristic around Human Body in a Room with Displacement Ventilation (치환환기되는 실내에 있어서 인체주변의 기류 및 온열환경 특성에 대한 검토)

  • Yang, Jeong-Hoon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.4
    • /
    • pp.299-306
    • /
    • 2007
  • Recently, the numerical analysis using person shape model for CFD (Computational Fluid Dynamic) has been researched widely for the thermal comfort and inhaled air quality of human body in the indoor environments. The purpose of this research is to examine the characteristic of airflow and thermal environment around human body by the experiment of displacement ventilation that assumes the indoor environment of natural convection. In this study, thermal manikin was used instead of real human body. The Airflow characteristic around human body was measured in precision by PIV (Particle Image Velocimetry). This experimental result will be used as data for CFD benchmark test using person shape model.

Study on the Thermal Deformation of the Air-conditioner Indoor Unit Assembly Using 3D Measurement and Finite Element Analysis (에어컨 실내기 사출 조립품의 열 변형 3D측정과 유한요소해석)

  • Hong, Seokmoo;Hwang, Jihoon;Kim, Cheulgon;Eom, Seong-uk
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.24 no.2
    • /
    • pp.251-255
    • /
    • 2015
  • Thermal deformation, such as bending and twisting, occurs among the polymer parts of air-conditioner indoor units because of repetitive temperature change during heating operation. In this study, a numerical method employing finite-element analysis to efficiently simulate the thermal deformation of an assembly is proposed. Firstly, the displacement of an actual assembly produced by thermal deformation was measured using a 3D optical measurement system. The measurement results indicated a general downward sag of the assembly, and the maximum displacement value was approximately 1 mm. The temperature distribution was measured using a thermographic camera, and the results were used as initial-temperature boundary conditions to perform temperature-displacement analysis. The simulation results agreed well with the measured data. To reduce the thermal deformation, the stiffness increased 100%. As the results, the maximum displacement decreased by approximately 5.4% and the twisting deformation of the holder improved significantly.

A Theoretical Study for the Thermal Diffusivity Measurement of Solid Material using Photothermal Displacement Method (광열변위법을 이용한 재료의 열확산계수 측정에 대한 이론적 연구)

  • Jeon, Pil-Soo;Lee, Eun-Ho;Lee, Kwang-Jai;Yoo, Jai-Suk;Kim, Ki-Hyun
    • Proceedings of the KSME Conference
    • /
    • 2000.04b
    • /
    • pp.132-137
    • /
    • 2000
  • A complete theoretical treatment of the photothermal displacement technique has been performed for thermal diffusivity measurement in solid materials. The influence of parameters - radius and modulation frequency of pump beam and thickness of material - on the phase lag was studied. The phase decreases up to a certain position, then starts to increase and does have an asymptotic value. The position, where phase has the minimum value, is a function of thermal diffusion length thickness of sample, and radius of pump beam. A new method based on minimum phase lag is described to determine the thermal diffusivity of solid material.

  • PDF

Thermal Diffusivity Measurement for Metal Using Phase Curve of Photothermal Displacement (광열변위의 위상곡선을 이용한 금속재료의 열확산계수 측정)

  • Lee, Eun-Ho;Lee, Gwang-Jae;Yu, Jae-Seok
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.1
    • /
    • pp.47-53
    • /
    • 2001
  • As the technology has developed and new materials have been produced, it is important to measure the thermal diffusivity of material and to predict the heat transfer in the solid subject to thermal processes. This measurement can be done in a non-contact way using photothermal displacenent spectroscopy. In this study, photothermal displacement method was used to measure the thermal diffusivity quantitatively. The specimens used in this study were the pure materials. The Ar-ion laser was used as an energy source and the periodical deformation induced by this pump laser was detected by the He-Ne laser. The magnitude and the phase angle of deformation gradient were measured. The thermal diffusivity was obtained by analyzing the phase angle of deformation gradient. As the result, comparing with the literature value, the thermal diffusivities of materials measured were showed about 2% error.

Large Displacement Polymer Bimorph Actuator for Out-of-Plane Motion

  • Jeung Won-Kyu;Choi Seog-Moon;Kim Yong-Jun
    • Journal of Electrical Engineering and Technology
    • /
    • v.1 no.2
    • /
    • pp.263-267
    • /
    • 2006
  • A new thermal bimorph actuator for large out-of-plane displacement is designed, fabricated and tested. The deflecting beam is composed of polyimide, heater, and polyvinyl difluorides with tetrafluoroethylene (PVDF-TrFE). The large difference of coefficient of thermal expansion (CTE) of two polymer layers (polyimide and PVDF-TrFE) can generate a significant deflection with relatively small temperature rise. Compared to the most conventional micro actuators based on MEMS (micro-electro mechanical system) technology, a large displacement, over 1 mm at 20 mW, could be achieved. Additionally, we can achieve response time of 14.6 ms, resonance frequency of 12 Hz, and reliability ability of $10^5$ cycles. The proposed actuator can find applications where a large vertical displacement is needed while maintaining compact overall device size, such as a micro zooming lens, micro mirror, micro valve and optical application.

Temperature Dependence of Magnetostriction in Terfenol-D (Terfenol-D의 온도에 따른 자기변형 특성)

  • 박영우;금기경;한승현
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.275-278
    • /
    • 2002
  • The performance of Terfenol-D, the commercially available magnetostrictive material, is highly dependent on the prestress, magnetic field intensity and temperature. This paper presents an experimental investigation of the temperature effect on the magnetostriction in Terfenol-D. The effects of both prestress and magnetic field on the magnetostriction are also presented. Experimental results show that both the prestress and magnetic field on the magnetostriction are significant. It is also observed that the displacement decreases slightly to around 40$^{\circ}C$, then increases to 80$^{\circ}C$. It indicates that the displacement decreases due to the reduced magnetization, and increases due to the thermal expansion, as the temperature increases. It means that the reduced magnetization affects more in the displacement change up to 40$^{\circ}C$, and the thermal expansion affects more in the displacement change beyond 40$^{\circ}C$.

  • PDF

Large Displacement Bimorph Actuator Using MEMS Technology (멤스 기술을 이용한 대변형 바이모프 구동기)

  • 정원규;최석문;김용준
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.1286-1289
    • /
    • 2004
  • A new thermal bimorph actuator for large out-of-plane displacement is designed, fabricated and tested. The deflecting beam is composed of polyimide, heater, and polyvinyl difluorides with tetrafluoroethylene(PVDF-TrFE). The large difference of coefficient of thermal expansion(CTE) of two polymer layers (polyimide and PVDF-TrFE) can generate a large deflection with relatively small temperature rising. Compared to the most conventional micro actuators based on MEMS(micro-electro mechanical system) technology, a large displacement, over 1 mm at 20 mW, could be achieved. The proposed actuator can find applications where a large vertical displacement is needed while keeping compact overall device size, such as a micro zooming lens.

  • PDF

Design of Thermal Displacement Compensation Sensor for High Reliability Machine Tools (고신뢰 머시닝센터를 위한 열변위 보상 센서 설계기술)

  • Kim, Il-Hae;Jang, Dong-Young;Park, Jeong-Hoon;Park, Sung-Wook;Shim, Poong-Soo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.28 no.8
    • /
    • pp.886-893
    • /
    • 2011
  • To increase the reliability and positional accuracy of a machine tool, a novel capacitive displacement sensor having a cylindrical shape is presented to measure the axial displacement of a machine tool spindle. Characteristics of the sensor were analyzed by numerical simulation. The sensor was built into a specific machine tool spindle and its performance was experimentally investigated. The accuracy of a thermal error compensation system of a machine tool can be enhanced greatly using proposed sensor.

A study on the electrical properties of lipid monolayers by displacement current method (변위전류법에 의한 지질단분자막의 전기특성에 관한 연구)

  • 이경섭;권영수
    • Electrical & Electronic Materials
    • /
    • v.9 no.5
    • /
    • pp.450-454
    • /
    • 1996
  • Maxwell-Displacement-Current(MDC) measuring technique has been applied to the study of monolayers of Dilauroylphosphatidylcholine (L-.alpha.-DLPC) and Dimyristoylphosphatidylcholine (L-.alpha.-DMPC). The displacement current was generated from monolayers on a water surface by monolayer compression. Displacement current was generated when the area per molecule was about 250.angs.$^{2}$, 280.angs.$^{2}$. Displacement current was generated in the gas state, gas/liquid state, and liquid state in the course of monolayer compression. The orientational change of molecules in monolayers was discussed on the basis of the MDCs obtained. Finally, we measured differential thermal analysis of sample.

  • PDF

Numerical and Experimental Studies on Thermal Strain Analysis of Al Alloy Casting Mold using Metal Foundry (금형주조기를 이용한 알루미늄 합금 금형의 수치해석적 열변형 해석과 실험에 관한 연구)

  • Oh, Yool-Kwon;Kim, Yong-Bum;Yoon, Hee-Sung
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2050-2054
    • /
    • 2007
  • This study numerically and experimentally investigated on thermal strain analysis of aluminum alloy casting mold using metal foundry. To predict the numerical result of thermal strain in Al alloy casting mold during the cooling process, it is performed the investigation of temperature distribution, stress and displacement based on the physical properties of Al alloy. In results of this study, Al alloy casting mold represented rapidly cooling graph during initial 20minutes after beginning cooling process, therefore value of stress and displacement is rapidly changed during initial 20minutes after beginning cooling process. In addition to, temperature distribution obtained by experiment confirmed corresponding pattern then compared numerical analysis with experiment. These results are distribute to make the effective and the high precision casting mold.

  • PDF