Kinetic and Thermodynamic Studies of Brilliant Green Adsorption onto Carbon/Iron Oxide Nanocomposite (탄소/산화철 나노복합재료의 Brilliant Green 흡착에 대한 반응속도론적, 열역학적 연구)

  • Ahmad, Rais;Kumar, Rajeev
    • Journal of the Korean Chemical Society
    • /
    • v.54 no.1
    • /
    • pp.125-130
    • /
    • 2010
  • In the present work, we have investigated the adsorption efficiency of carbon/iron oxide nanocomposite towards removal of hazardous brilliant green (BG) from aqueous solutions. Carbon/iron oxide nanocomposite was prepared by chemical precipitation and thermal treatment of carbon with ferric nitrate at $750^{\circ}C$. The resulting material was thoroughly characterized by TEM, XRD and TGA. The adsorption studies of BG onto nanocomposite were performed using kinetic and thermodynamic parameters. The adsorption kinetics shows that pseudo-second-order rate equation was fitted better than pseudo-first-order rate equation. The experimental data were analyzed by the Langmuir and Freundlich adsorption isotherms. Equilibrium data was fitted well to the Langmuir model with maximum monolayer adsorption capacity of 64.1 mg/g. The thermodynamic parameters were also deduced for the adsorption of BG onto nanocomposite and the adsorption was found to be spontaneous and endothermic.

Emission Characteristics of Odorous Sulfur Gases from Food Types: A Case Study on Boiled Egg, Milk, Canned Meat, and Strawberry (음식물의 악취 황화합물 발생특성 조사: 계란, 우유, 고기통조림, 딸기에 대한 사례 연구)

  • Kim, Bo-Won;Ahn, Jeong-Hyeon;Kim, Ki-Hyun;Jo, Sang-Hee
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.29 no.5
    • /
    • pp.615-624
    • /
    • 2013
  • In this study, the emission patterns of reduced sulfur compounds (RSC) were investigated using four different types of food samples (boiled egg, milk, canned meat and strawberry) between fresh and decaying stages. To this end, the concentrations of RSCs were measured at storage days of 0, 1, 3, 6, and 9 under room temperature. Four sulfur compounds ($H_2S$, $CH_3SH$, DMS and DMDS) were selected as target compounds along with two reference compounds ($CS_2$ and $SO_2$). Their concentrations were quantified using GC-PFPD equipped with thermal desorption (TD) system. The boiled egg showed the highest concentration of $H_2S$ (3,655 ppb) at D-1, while $CH_3SH$ reached its maximum value of 64.4~78.5 ppb after 3 days. In milk samples, concentration of $CH_3SH$, DMS, and DMDS went up to 487, 16.3, and 578 ppb, respectively with the progress of decay (D-9). In case of canned meat, concentration of $H_2S$ and $CH_3SH$ peaked in the beginning (D-0) such as 345 and 66.6 ppb. In case of strawberry, $CH_3SH$ and DMDS showed the maximum concentrations 135 and 50.5 ppb at D-1, respectively. The olfactometry dilution-to-threshold (D/T) ratio by air dilution sensory (ADS) test showed similar patterns when sum of odor intensity (SOI) was derived via conversion of odorant concentration data. The results of this study confirm that the time of strong RSC emissions is distinguished for each food type between fresh (e.g., strawberries) and decaying conditions (e.g., milk).

The Development of Exposure Assessment Tools for Risk Assessment of Volatile Organic Compounds (VOCs의 위해성 평가를 위한 노출분석 방법 연구)

  • Jo, Seong-Joon;Shin, Dong-Chun;Chung, Yong;Lee, Duck-Hee;Breysse, Patrick N.
    • Environmental Analysis Health and Toxicology
    • /
    • v.17 no.2
    • /
    • pp.147-160
    • /
    • 2002
  • Volatile organic compounds (VOCs) are an important public health issue in Korea and many important questions remain to be addressed with respect to assessing exposure to these compounds. Because they are ubiquitous and highly volatile, special techniques must be applied in their analytic determination Valid Personal exposure assessment methods are needed to evaluate exposure frequency, duration and intensity, as well as their relationship to personal exposure characteristics. Biological monitoring is also important since it may contribute significantly in risk assessment by allowing the estimation of effective absorbed doses. This study was on ducted to establish the environmental measurement, personal dosimetry and biological monitoring methods for VOCs. These methods are needed to compare blood, urinary and exhalation breath VOC levels and to provide tools for risk assessment of VOC exposure. Passive monitors (badge type) and a active samplers (trap) for the VOCs collection were used for air sampling. Methods development included determining the minimum detectable amounts of VOCs in each media, as well as evaluating collection methods and developing analytical procedures. Method reliability was assessed by determining breakthrough volumes and comparing results between laboratories and with other methods. A total capacity of trap used in this study was 60ι. Although variable by compound, the average breakthrough was 20%. Also, there was no loss of compounds in trap even if keep for 45 day in -7$0^{\circ}C$. The recovery of active and passive methods was 69% ~ 126% and method detection limit was 0.24 $\mu\textrm{g}$/trap and 0.07 $\mu\textrm{g}$/badge. There was no statistical difference (P > 0.05) between active and passive methods.

The Analysis of Sulfur Compounds of Odorous Material in Kunsan Industrial Complex

  • Kim, Seong-Cheon;Kim, Ki-Hyun;Choi, Yeo-Jin
    • Proceedings of the Korean Environmental Health Society Conference
    • /
    • 2005.06a
    • /
    • pp.399-405
    • /
    • 2005
  • In this study, we investigated the gas chromatography (GC) and pulsed flame photometric detection (PFPD) system for the analysis of four major reduced S compounds including hydrogen sulfide ($H_2S)$; methyl mercaptan ($CH_3SH$); dimethyl sulfide (DMS); and dimethyl disulfide(DMDS) contained in environmental samples. To analyze these compounds in high concentration range (above ppb level), we developed a high mode analytical setting with the loop-injection system. By contrast, we also established a low mode setting for the analysis of low concentration samples (ppt-level samples from ambient air) by the combination with thermal desorption unit(TDU). Comparative analysis of both settings revealed that relative detection properties of four S compounds are systematic enough. The results of high mode analysis indicated that the patterns were systematic among compounds: H2S exhibited the lowest sensitivity, while DMBS showed the strongest one. The results were also compared in terms of sensitivity reductions for all compounds by dividing slope ratios between low and high mode system. Although low mode system exhibited significant reductions on the order of a few tens times, their detection characteristics were highly consistent as it was shown in the high mode setting. To learn more about absolute and relative relations between two different modes of S analysis, future studies may have to be directed to cover more complicated nature of GC/PFPD performance. Hydrogen sulfide($H_2S$) was over in summer about low level of olfactory sense 410 ppt, Methyl mercaptan(C$H_3SH$) was over in apring and summer about low level of olfactory sense 70, Dimethyl sulfide(DMS) was not over in four season about low level of olfactory sense 2,200 ppt. Carbon disulfide($CS_2$) was not over in four deason about Tow level of olfactory sense 210,000, Dimethyl disulfide(DMDS) was not over in summer about low level of olfactory sense2,000.

  • PDF

Characterization of Volatile Organic Compounds(VOCs) Concentrations in Jinju (진주시 대기중 휘발성 유기화합물의 농도특성 기초조사)

  • Park, Jeong-Ho;Park, Hyung-Gun;Suh, Jeong-Min
    • Journal of Environmental Science International
    • /
    • v.22 no.1
    • /
    • pp.91-98
    • /
    • 2013
  • In order to study the seasonal patterns and possible origins of air concentrations of volatile organic compounds(VOC), measurements were taken with GC-MS at 3 sampling sites in Jinju for 12 months from Mar. 2010 to Feb. 2011. Atmospheric VOC are sampled on tubes containing solid adsorbents(Tenax TA) with a time resolution of 2hrs. Composition and concentration of VOC are analysed with a GC system equipped with thermal desorption apparatus(ATD). The most abundant compound appeared to be Toluene, Ethylbenzene and m,p-Xylene. The mean concentrations of Benzene were 0.20 ppb at GN site, 0.18 ppb at DA site, and 0.25 ppb at SP site, respectively. VOC concentration showed a strong seasonal variation, with higher concentrations during the spring and lower concentrations during the summer. The results showed that monthly fluctuations in measured VOC concentrations depended on variations in the strength of sources, as well as on photochemical activity and meteorological conditions. In Jinju, the total VOC emissions for 2009 were estimated to be 4,407 ton/year by Clean Air Policy Support System(CAPSS). It is shown that solvent use 57.5%(2,534 ton/yr), waste treatment and disposal 23.3%(1,025 ton/yr), and mobil source-road traffic 12.2%(537 ton/yr) are the most significant anthropogenic source.

Fragrance Composition in Six Tree Peony Cultivars

  • Zhao, Jing;Hu, Zeng-Hui;Leng, Ping-Sheng;Zhang, Hui-Xiu;Cheng, Fang-Yun
    • Horticultural Science & Technology
    • /
    • v.30 no.6
    • /
    • pp.617-625
    • /
    • 2012
  • Tree peony is a traditional famous flower of China, and plays an important role in Chinese traditional culture. But the floral scent of tree peony in vivo is little known. In this study, in order to explore the floral composition of tree peony, floral volatiles of six cultivars, including Paeonia suffruticosa 'Zhaofen' (ZF), P. suffruticosa 'Luoyanghong' (LYH), P. ostii 'Fengdanbai' (FDB), P. ${\times}$ lemonei 'High noon' (HN), P. ${\times}$ lemonei 'Renown' (R), and P. rockii 'Gaoyuanshenghuo' (GYSH) were collected by dynamic headspace and then identified by Automated Thermal Desorption-Gas Chromatography/Mass Spectometry. The results showed that floral fragrances of the six cultivars were qualitatively and quantitatively distinct. A total of 105 volatiles involving ten categories were detected. But not all volatile categories were emitted from these cultivars. The six peony cultivars emitted some shared compounds and peculiar compounds. The total released amounts of volatiles emitted from six cultivars were found significantly different, which was greatest for 'GYSH'. The most abundant volatile compounds detected from 'ZF', 'LYH', 'FDB', 'HN', 'R', and 'GYSH' were respectively ${\alpha}$-pinene, 2,3-dihydroxy propanal, 3-methyl-1-butanol, 2-ethyl-1-hexanol, acetic acid 1-methylethyl ester, and 5-ethyl-2,2,3-trimethyl heptane. This result may contribute to exploring the biosynthesis and emission mechanism of floral scent in tree peony.

Remediation of Bunker Fuel Oil C Contaminated Soil with Microwave Radiation and Heating Elements (마이크로파 조사와 발열체를 이용한 벙커C유 오염토양의 복원)

  • Oh, Da-kyung;Lee, Tae-jin
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.37 no.8
    • /
    • pp.458-464
    • /
    • 2015
  • Total petroleum hydrocarbon (TPH) removal and temperature variations in bunker fuel oil C contaminated soil were investigated by using microwave radiation in the presence of triiron oxide or activated carbon as a heating element. Temperature increments of $1.4{\sim}1.6^{\circ}C/Watt$ were observed, when 100~500 watt of microwave radiation was applied for the contaminated soil in the presence of triiron oxide or activated carbon. Temperature variation of the soil was more rapid in the presence of triiron oxide than activated carbon. 10% or 25% of heating element content was required to reach the temperature of thermal desorption for triiron oxide and activated carbon respectively. After radiation, 44.1% and 89.4% of initial TPH in soil was removed in the presence of triiron oxide and activated carbon respectively. It was observed that activated carbon was more reactive than triiron oxide for the removal of high molecular carbon of bunker fuel oil C.

Temporal Characteristics of Volatile Organic Compounds in Newly-Constructed Residential Buildings: Concentration and Source

  • Shin, Seung-Ho;Jo, Wan-Kuen
    • Environmental Engineering Research
    • /
    • v.18 no.3
    • /
    • pp.169-176
    • /
    • 2013
  • The present study was designed to examine the concentrations, emission rates, and source characteristics of a variety of volatile organic compounds (VOCs) in 30 newly-constructed apartment buildings by measuring indoor and outdoor VOC concentrations over a 2-year period. For comparison, seven villa-type houses were also surveyed for indoor and outdoor VOC concentrations over a 3-month period. Indoor and outdoor air samples were collected on Tenax-TA adsorbent and analyzed using a gas chromatograph (GC)/mass spectrometer system or a GC/flame ionization detector system coupled to a thermal desorption system. The long-term change in indoor VOC concentrations depended on the type of VOCs. Generally, aromatic (except for naphthalene), aliphatic, and terpene compounds exhibited a gradual deceasing trend over the 2-year follow-up period. However, the indoor concentrations of the six halogenated VOCs did not significantly vary with time changes. Similar to these halogenated VOCs, the indoor naphthalene concentrations did not vary significantly with time changes over the 2-year period. Unlike the halogenated VOCs, the indoor naphthalene concentrations were much higher than the outdoor concentrations. The indoor concentrations of aliphatic and aromatic compounds were higher for the villa-type houses when compared to those of apartment buildings. In addition, four source groups (floor coverings and interior painting, household products, wood paneling and furniture, moth repellents) and three source groups (floor coverings and interior painting, household products, and moth repellents) were considered as potential VOC sources inside apartment buildings for the first- and second-year post-occupancy stages, respectively.

Characterization of Atmospheric Concentrations of Volatile Organic Compounds in Industrial Areas of Pohang and Gumi Cities (포항과 구미의 대규모 산단지역 대기 중 휘발성 유기화합물 농도 분포 특성에 관한 연구)

  • Baek Sung-Ok;Kim Soo-Hyun;Kim Mi-Hyun
    • Environmental Analysis Health and Toxicology
    • /
    • v.20 no.2 s.49
    • /
    • pp.167-178
    • /
    • 2005
  • This study was carried out to evaluate the temporal, spatial, and seasonal variations of VOC, and to characterize the VOC concentrations in two large industrial complexes located in Pohang and Gumi cities. Twenty -four hours continuous sampling of selected VOC was made with STS 25 sequential tube samplers and double-bed adsorbent tubes. Air samples were collected every three hour interval for 7 consecutive days in each site during summer and winter. VOC were determined by thermal desorption coupled with GC/MS. A total of 27 VOCs of environmental concern were determined, including aliphatic, aromatic and halides. Generally. concentrations of toxic VOC were higher in Gumi than Pohang, and VOC levels in industrial areas were typically several-fold higher than those in residential areas. The most abundant VOC appeared to be toluene for both cities. However, chlorinated VOC were higher in Gumi than Pohang, while aromatic VOC were more abundant in Pohang than in Gumi. Two cities showed relatively different variations of VOC concentrations within a day. It is likely that traffic related sources are major factors affecting the VOC in Pohang, and industrial solvents usages are important sources in Gumi. These results imply that the occurrence and levels of atmospheric VOC are strongly dependent on the type of industries in each city. Therefore, in order to develop any control strategies or to establish the priority rankings for VOC in large industrial complexes, the type of industries and the occurrence of VOC in the atmosphere should be taken into consideration.

Safety Profile Assessment and Identification of Volatile Compounds of Krill Eupausia superba Oil and Residues Using Different Extraction Methods

  • Haque, A.S.M. Tanbirul;Kim, Seon-Bong;Lee, Yang-Bong;Chun, Byung-Soo
    • Fisheries and Aquatic Sciences
    • /
    • v.17 no.2
    • /
    • pp.159-165
    • /
    • 2014
  • In this study, Krill Eupausia superba oil was extracted using different solvents and supercritical carbon dioxide (SC-$CO_2$). During SC-$CO_2$ extraction, the pressure was set at 40 MPa and temperatures ranged from $40^{\circ}C$ to $55^{\circ}C$. We examined the differences in volatile compounds and safety profiles among extraction methods. Volatile compounds were determined using the thermal desorption system integrated with gas chromatography-mass spectrometry (GC-MS). Heavy metal content was analyzed by inductively coupled plasma mass spectrometry (ICP-MS). According to our results 10 volatile compounds were identified in krill sample. After SC-$CO_2$ extraction of oil, the concentrations of volatile compounds decreased, but increased after solvent extraction. In krill, heavy metal concentrations remained within the permissible limit. Moreover, Zn and Fe which have health benefits were detected at high concentrations. During a 90 days storage period at different temperatures, microbial activity was found to be lowest in SC-$CO_2$ extracted residues. Thus, the quality of krill oil and the residues obtained using SC-$CO_2$ extraction was higher and the oil was safer than those obtained using conventional solvent extraction. These results can be applied to the food industry to maintain high quality krill products.