• Title/Summary/Keyword: Thermal Comfort Temperature

Search Result 469, Processing Time 0.034 seconds

Development of Cool-touch Functional Dancesport Top for Middle-aged Women (중년 여성을 위한 냉감기능성 댄스스포츠 상의 개발)

  • Jun, Mi-Hwa;Jang, Jeong-Ah
    • Fashion & Textile Research Journal
    • /
    • v.22 no.5
    • /
    • pp.628-638
    • /
    • 2020
  • This study develops a cool-touch functional Dancesport top for middle-aged women by using cool-touch materials in areas where surface temperature becomes high after exercise. The post-exercise surface temperature of the developed research product was compared and analyzed. In addition, subjective evaluation of cool-touch as well as appearance and movement evaluations were performed. The results are as follows. In designing the research product, a detachable neckband was made using highly-preferred hydrated polymer crystals. A material with high moisture absorption speed was also used in F1, S1, under arm and B5, while a material with good thermal conductivity was used in other parts of the bodice. Deodorant tape with antibacterial and deodorant effects was incorporated in the armpit for additional comfort. As for wear evaluation of the research product, significant differences were found in 10 areas using a material with high moisture absorption speed to compare and analyze the post-exercise surface temperatures of the clothing. The temperature difference between the compared top and the research product in the neckband area was 9.16℃, demonstrating clear cool-touch function in using cool-touch material. In the subjective evaluation of cool-touch function, the results showed high scores when asked about the efficiency of the detachable neckband and the ease of movement when wearing the product. In the appearance evaluation, significant differences were found in 11 items, including redundant folds, tightfit, fit, and design line. The overall mean score of the movement evaluation was 4.6, indicating excellent function for movement.

Physiological Responses and Subjective Sensation of Human Body Wearing OnMapsi in Heating Environment (난방환경에서 온(溫)맵시 착용에 따른 생리적 반응 및 주관적 감각)

  • Na, Young-Joo;Lee, Ji-Yun
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.35 no.1
    • /
    • pp.1-12
    • /
    • 2011
  • This study tests the performance of the recommended winter dress OnMapsi for an office worker through the analysis of skin temperature changes according to the heating environment. We tested and compared the effects of with/without undergarments for 4 male subjects in an artificial-climate chamber with two air temperatures of $19^{\circ}C$ and $22^{\circ}C$, $50{\pm}10%$ R.H. During the 60 minute experiment that simulated office work, the subjective feelings (that included thermal, humidity and comfort sensation, and skin temperature) were measured at equal intervals. The results show that the forehead and chest skin temperatures were not affected by air temperature or clothing type, while the hand and foot skin temperatures were affected at $0.3-0.9^{\circ}C$ depending on clothing type and $1.9-2.2^{\circ}C$ depending on air temperature. The mean skin temperature was decreased by the experimental time pass more with regular formal wear than with OnMapsi. The second experiment located the ambient temperature in which subjects wearing OnMapsi show equal skin temperaturesto those without undergarments at $22^{\circ}C$. Therefore it is possible to decrease heating temperatures to $18-21^{\circ}C$ in the office for winter OnMapsi wear that produces a skin temperature and thermal sensation that is the same as those at $22^{\circ}C$.

A Development of the Performance Analysis Program Package of the Automatic Temperature Control System for Heating (난방용 자동온도조절기 성능분석용 프로그램 및 패키지 개발)

  • Kim, Yong-Ki;Woo, Nam-Sub;Lee, Tae-Won;Ahn, Byung-Cheon
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.1209-1214
    • /
    • 2009
  • Various automatic temperature control systems have been used widely in Korea for the conservation of heating energy and the enhancement of thermal comfort in residential buildings. But the heating control performance for automatic temperature control systems extensively vary with the design and operational conditions of the heating system, the climate condition and others. It was introduced in this study a numerical calculation program package to analyze heating control characteristics of the automatic temperature control system. This package is able to analyze the room air temperature, return water temperature, supplied heating flux and flow rate, and so on. One the other hand, the simulation results were verified by comparing with the field test results.

  • PDF

A Comparison of Heating Control Characteristics by Temperature Sensing Methods for Thermostatic Valves with the Proportional Control Mode (비례제어식 자동온도조절기의 온도감지방식별 난방제어 특성 비교)

  • Kim, Yong-Ki;Lee, Tae-Won;Kang, Sung-Ju
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.161-166
    • /
    • 2007
  • Various thermostatic valves have been used widely in Korea for conservation of heating energy and enhancement of thermal comfort in residential buildings. But heating control performances of thermostatic valves extensively vary with the design and operational conditions of the heating system, climate condition and others. An experimental method was carried out in this study to analyze heating control characteristics by temperature sensing methods of thermostatic valves for various parameters, such as supply temperatures and flow rate of hot water, the position of room thermostats and outdoor air temperatures. As a result, the heat flow rate per day of S-Valve($34^{\circ}C$-Type) of water temperature sensing method was liked that of C-Valve of indoor air temperature sensing method with stage 3.3 of room thermostat in case supply temperature of hot water was $45^{\circ}C$, flow rate was 1.3 L/min and outdoor air temperature was $7.8^{\circ}C$.

  • PDF

Thermoregulatory Behaviors of Obese Children According to Temperature Change (환경온 변화에 따른 비만 아동의 체온조절 행동)

  • Jeong, Woon Seon;Lee, Hye Sang;Park, Ung Im
    • The Korean Journal of Community Living Science
    • /
    • v.25 no.4
    • /
    • pp.487-494
    • /
    • 2014
  • This study investigates thermoregulatory behaviors of obese children for their thermal comfort. Nine normal-weight children (NWC) and nine obese children (OC) participated in the study. All subjects were fourth-graders and sixth-graders in elementary school. An informed consent form was obtained from each child and his or her mother. The questionnaire method was used, and the experiment was conducted to determine the preferred amount of clothing at $17^{\circ}C$ and the preferred temperature at $33^{\circ}C$. According to the results, OC were more susceptible to heat than NWC, whereas there was no significant difference in their susceptibility to cold. There were no significant differences of the oral temperature and the mean skin temperature between the two groups, but changes in forearm blood flow were less in OC than in NWC. There was no significant difference in the preferred amount of clothing between OC and NWC, and the preferred temperature was higher in NWC than in OC. The results based on the questionnaire are consistent with those based on the experiment. A compositive study of physical exercise, eating behavior, and wearing behavior should be useful for developing programs for preventing and treating obese children.

Study on the International Climatic Testing Standard for Passenger Car (철도차량의 국제 기후환경 시험규격의 수행방안 연구)

  • Yoon, Young-Kwan;Cho, Young-Min;Choi, Jin-Sik;Jung, Woo-Sung;Kwon, Soon-Bark;Park, Duck-Shin
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.1327-1334
    • /
    • 2011
  • subway has became citizen's feet which can transport over 24 million people since the era of high oil price started. Because the request of passengers for more comfortable thermal comfort is drastically increasing, the importance of comfortable environment in the passenger car is more stressed. This paper suggests an indicator whether railroad car is fitted with suitable cooling and heating equipment by applying the international climatic testing method, UIC 553, 553-1. Specified ambient temperature, humidity, solar irradiation condition, as well as extreme outside condition, can be achieved by using an environmental chamber. The change temperature and humidity in the passenger space can be monitored to judge if the passenger room is nicely air-conditioned.

  • PDF

A Study on the Application of the Optimal Control System for Heat Source and HVAC System (열원 및 공조설비의 최적제어시스템 현장 적용성에 관한 연구)

  • Baek, Seung-Jae;Kim, Jin;Ahn, Byung-Cheon;Song, Jae-Yeob
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.1014-1019
    • /
    • 2009
  • The optimal control system for heat source and HVAC system has been developed for minimizing energy consumption while maintaining the comfort of indoor thermal environment in terms of the environmental variables such as time varying indoor load and outdoor temperatures. The optimal set-points of control parameters are supply air temperature and chilled or hot water temperatures. The optimal control study has been implemented for biosafety laboratory by using TRNSYS simulation program in order to investigate energy performance for heat source and HVAC system.

  • PDF

Real Time Near Optimal Control Application Strategy of Central Cooling System (중앙냉방시스템의 실시간 준최적제어 적용에 따른 실험적 연구)

  • Ahn, Byung-Cheon;Song, Jae-Yeob;Joo, Yong-Duk;Kim, Jin
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.7
    • /
    • pp.470-477
    • /
    • 2008
  • The near-optimal control algorithm for central cooling system has been developed for minimizing energy consumption while maintaining the comfort of indoor thermal environment in terms of the environmental variables such as time varying indoor cooling load and outdoor temperatures. The optimal set-points of control parameters with near-optimal control are supply air and chilled water temperatures. The near optimal control algorithm has been implemented by using LabVIEW program in order to analyze energy performance for central cooling control system.

Piglets' Surface Temperature Change at Different Weights at Birth

  • Caldara, Fabiana Ribeiro;dos Santos, Luan Sousa;Machado, Sivanilza Teixeira;Moi, Marta;de Alencar Naas, Irenilza;Foppa, Luciana;Garcia, Rodrigo Garofallo;de Kassia Silva dos Santos, Rita
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.27 no.3
    • /
    • pp.431-438
    • /
    • 2014
  • The study was carried out in order to verify the effects of piglets' weight at birth on their surface temperature change (ST) after birth, and its relationship with ingestion time of colostrum. Piglets from four different sows were weighed at birth and divided into a totally randomized design with three treatments according to birth weight (PBW): T1 - less than 1.00 kg, T2 - 1.00 to 1.39 kg, and T3 - higher than or equal to 1.40 kg. The time spent for the first colostrum ingestion was recorded (TFS). Images of piglets' surface by thermal imaging camera were recorded at birth (STB) and 15, 30, 45, 60, and 120 min after birth. The air temperature and relative humidity were recorded every 30 min and the indexes of temperature and humidity (THI) were calculated. A ST drop after 15 min from birth was observed, increasing again after sixty minutes. Positive correlations were found between the PBW and the ST at 30 and 45 min after birth. The PBW was negatively correlated with the TFS. The THI showed high negative correlations (-0.824 and -0.815) with STB and after 15 min from birth. The piglet's surface temperature at birth was positively correlated with temperature thereof to 15 min, influencing therefore the temperatures in the interval of 45 to 120 min. The birth weight contributes significantly to postnatal hypothermia and consequently to the time it takes for piglets ingest colostrum, requiring special attention to those of low birth weight.

Comparison of Rooftop Surface Temperature and Indoor Temperature for the Evaluation of Cool Roof Performance according to the Rooftop Colors in Summer: Using Thermal Infrared Camera Mounted on UAV (옥상 색상에 따른 쿨루프 성능평가를 위한 여름철 옥상 표면 및 실내온도 비교 분석 : 무인항공기에 장착된 열적외선 카메라를 이용하여)

  • Lee, Ki Rim;Seong, Ji Hoon;Han, You Kyung;Lee, Won Hee
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.37 no.1
    • /
    • pp.9-18
    • /
    • 2019
  • The intensity and the number of days of high temperature occurrence are also high and record heat occurred. In addition, the global warming phenomenon is intensifying globally, and especially in South Korea, the urban heat island phenomenon is also occurring due to rapid urbanization due to rapid industrial development. As the temperature of the city rises, it causes problems such as the comfort of the residential living and the cooling load. In this study, the cool roof performance is evaluated according to the roof color to reduce these problems. Unlike previous studies, UAV(Unmanned Aerial Vehicle) thermal infrared camera was used to obtain the surface temperature (white, grey, green, blue, brown, black) according to the rooftop color by remote sensing technique. As a result, the surface temperature of white color was $11{\sim}20^{\circ}C$ lower than other colors. Also air conditioning temperature of white color was $1.5{\sim}4.4^{\circ}C$ lower than other colors and the digital thermometer of white color was about $1.5{\sim}3.5^{\circ}C$ lower than other colors. It was confirmed that the white cool roof performance is the best, and the UAV and the thermal infrared camera can confirm the cool roof performa.