• 제목/요약/키워드: Thermal Capacity

검색결과 1,279건 처리시간 0.029초

고강도 저열팽창 인바합금에 있어서 CO 첨가의 영향 (Effects of Co Addition in High Strength and Low Thermal Expansion Invar Alloy)

  • 김봉서;조영암;유경재;권해웅;이희웅;김병걸
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 D
    • /
    • pp.1901-1903
    • /
    • 1999
  • To investigate invar alloy as a core material for increased capacity over-head transmission line which have high strength and low thermal expansion coefficient, hardness and thermal expansion coefficient of Fe-Ni-Co alloy have been studied. It is necessary that invar alloy have low thermal expansion coefficient and high strength for increased capacity over-head transmission line. In this paper. we tried to find out the effect of Ni and Co which has ferromagnetic properties and high saturation magnetization. It was found that Ni decrease thermal expansion coefficient and hardness, Co decrease thermal expansion coefficient but increase hardness in Fe-xNi-Co system. In Fe-(29-x)Ni-Co system, the material has no low thermal expansion properties substituting Co instead of Ni in concentration range of $1\sim7$%Co.

  • PDF

고용량 리튬이온이차전지용 고내열성 분리막 코팅장비 연구 (A Study on High Thermal Stable Separator Coating Machine for High-Capacity Lithium Ion Secondary Battery)

  • 노진희;손화진;이호철;박정현
    • 한국기계가공학회지
    • /
    • 제18권12호
    • /
    • pp.45-51
    • /
    • 2019
  • As the separator becomes thinner, the role of thermal stability becomes more important in ensuring the high capacity of medium- and large-sized lithium-ion secondary batteries. In this study, we researched coating technology to improve the separator's thermal stability. We minimized the coating time by optimizing the design of a vertical two-stage coater that was thin, uniform, and capable of coating on both sides at the same time with a maximum 2㎛ thickness coating layer of fluorinated polymer (PVdF-HFP) on the bare polyethylene (PE) separator, which increased the thermal stability. In addition, during the coating process, a dual-jacket-roll method of drying was developed that increased the drying effectiveness without thermal damage to the separator. We also investigated the thermal stability of the separator manufactured from a coating machine, and studied the battery-applied performance by making a lithium-ion pouch battery.

Dynamic Thermal Rating of Overhead Transmission Lines Based on GRAPES Numerical Weather Forecast

  • Yan, Hongbo;Wang, Yanling;Zhou, Xiaofeng;Liang, Likai;Yin, Zhijun;Wang, Wei
    • Journal of Information Processing Systems
    • /
    • 제15권4호
    • /
    • pp.724-736
    • /
    • 2019
  • Dynamic thermal rating technology can effectively improve the thermal load capacity of transmission lines. However, its availability is limited by the quantity and high cost of the hardware facilities. This paper proposes a new dynamic thermal rating technology based on global/regional assimilation and prediction system (GRAPES) and geographic information system (GIS). The paper will also explore the method of obtaining any point meteorological data along the transmission line by using GRAPES and GIS, and provide the strategy of extracting and decoding meteorological data. In this paper, the accuracy of numerical weather prediction was verified from the perspective of time and space. Also, the 750-kV transmission line in Shaanxi Province is considered as an example to analyze. The results of the study indicate that dynamic thermal rating based on GRAPES and GIS can fully excavate the line power potential without additional cost on hardware, which saves a lot of investment.

열 열화한 열전도성 실리콘 고무의 전기특성 (Electric Properties of Thermal Conductive Silicone Rubber due to Thermally Degradation)

  • 이성일
    • 한국전기전자재료학회논문지
    • /
    • 제29권12호
    • /
    • pp.835-840
    • /
    • 2016
  • In this study, the electrostatic capacity and dielectric loss tangent for $20{\mu}m$ thick thermal conductivity silicone rubber which is heated at 80 degrees for 8 hours has been measured at temperature of $30^{\circ}C{\sim}170^{\circ}C$, frequency of 0.1~1 MHz. The results of degradation evaluation by this study are as follows. In low frequency, it found that the electrostatic capacity decreased with increasing temperature. On the other hand, it confirmed that the range of the electrostatic capacity narrowed with increasing frequency. It confirmed that there are the carboxylic acid structure and C-O bonding at range of wave number 1,000cm-1 to 1,300cm-1.

가압식 대용량 액체수소 저장탱크의 단열 성능과 BOR (Insulation Performance and BOR of Pressurized Large-capacity Liquid Hydrogen Storage Tank)

  • 서흥석;이영범;김동혁;박창원
    • 한국수소및신에너지학회논문집
    • /
    • 제34권6호
    • /
    • pp.650-656
    • /
    • 2023
  • In order to efficiently control boil-off rate of a liquefied hydrogen tank, the important thing is to maintain an appropriate vacuum level. however, compared to small and medium-sized storage tank, it is very difficult to create and maintain vacuum in large-capacity storage tanks. In this study, we aim to determine the target level of future large-capacity storage tank technology development and secure basic data on performance test methods by analyzing the corelation between evaporation gas and thermal conductivity of liquefied hydrogen storage tanks.

슬래브축열 시스템 설계인자의 감도해석 (A Sensitivity Analysis of Design Factors of Air-Conditioning System with Slab Thermal Storage)

  • 정재훈
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 동계학술발표대회 논문집
    • /
    • pp.590-595
    • /
    • 2008
  • In this paper, the sensitivity analysis was examined about the main factors that compose an air-conditioning system with slab thermal storage by using the analytic solution. Those factors are the insulation performance of floor slab surface, the slab thickness, the heat capacity of floor slab, the air change rate, and the insulation performance of the wall. The slab thickness and heat capacity of floor slab that minimize heating loads was gained by sensitivity analysis. It is became clear that the insulation performance of slab surface, high airtightness and high heat insulation are important design factors in air conditioning system with slab thermal storage.

  • PDF

Code development on steady-state thermal-hydraulic for small modular natural circulation lead-based fast reactor

  • Zhao, Pengcheng;Liu, Zijing;Yu, Tao;Xie, Jinsen;Chen, Zhenping;Shen, Chong
    • Nuclear Engineering and Technology
    • /
    • 제52권12호
    • /
    • pp.2789-2802
    • /
    • 2020
  • Small Modular Reactors (SMRs) are attracting wide attention due to their outstanding performance, extensive studies have been carried out for lead-based fast reactors (LFRs) that cooled with Lead or Lead-bismuth (LBE), and small modular natural circulation LFR is one of the promising candidates for SMRs and LFRs development. One of the challenges for the design small modular natural circulation LFR is to master the natural circulation thermal-hydraulic performance in the reactor primary circuit, while the natural circulation characteristics is a coupled thermal-hydraulic problem of the core thermal power, the primary loop layout and the operating state of secondary cooling system etc. Thus, accurate predicting the natural circulation LFRs thermal-hydraulic features are highly required for conducting reactor operating condition evaluate and Thermal hydraulic design optimization. In this study, a thermal-hydraulic analysis code is developed for small modular natural circulation LFRs, which is based on several mathematical models for natural circulation originally. A small modular natural circulation LBE cooled fast reactor named URANUS developed by Korea is chosen to assess the code's capability. Comparisons are performed to demonstrate the accuracy of the code by the calculation results of MARS, and the key thermal-hydraulic parameters agree fairly well with the MARS ones. As a typical application case, steady-state analyses were conducted to have an assessment of thermal-hydraulic behavior under nominal condition, and several parameters affecting natural circulation were evaluated. What's more, two characteristics parameters that used to analyze natural circulation LFRs natural circulation capacity were established. The analyses show that the core thermal power, thermal center difference and flow resistance is the main factors affecting the reactor natural circulation. Improving the core thermal power, increasing the thermal center difference and decreasing the flow resistance can significantly increase the reactor mass flow rate. Characteristics parameters can be used to quickly evaluate the natural circulation capacity of natural circulation LFR under normal operating conditions.

Enhancement of Electrochemical Activity of Ni-rich LiNi0.8Mn0.1Co0.1O2 by Precisely Controlled Al2O3 Nanocoatings via Atomic Layer Deposition

  • Ramasamy, Hari Vignesh;Sinha, Soumyadeep;Park, Jooyeon;Gong, Minkyung;Aravindan, Vanchiappan;Heo, Jaeyeong;Lee, Yun-Sung
    • Journal of Electrochemical Science and Technology
    • /
    • 제10권2호
    • /
    • pp.196-205
    • /
    • 2019
  • Ni-rich layered oxides $Li(Ni_xCo_yMn_z)O_2$ (x + y + z = 1) have been extensively studied in recent times owing to their high capacity and low cost and can possibly replace $LiCoO_2$ in the near future. However, these layered oxides suffer from problems related to the capacity fading, thermal stability, and safety at high voltages. In this study, we use surface coating as a strategy to improve the thermal stability at higher voltages. The uniform and conformal $Al_2O_3$ coating on prefabricated electrodes using atomic layer deposition significantly prevented surface degradation over prolonged cycling. Initial capacity of 190, 199, 188 and $166mAh\;g^{-1}$ is obtained for pristine, 2, 5 and 10 cycles of ALD coated samples at 0.2C and maintains 145, 158, 151 and $130mAh\;g^{-1}$ for high current rate of 2C in room temperature. The two-cycle $Al_2O_3$ modified cathode retained 75% of its capacity after 500 cycles at 5C with 0.05% capacity decay per cycle, compared with 46.5% retention for a pristine electrode, at an elevated temperature. Despite the insulating nature of the $Al_2O_3$ coating, a thin layer is sufficient to improve the capacity retention at a high temperature. The $Al_2O_3$ coating can prevent the detrimental surface reactions at a high temperature. Thus, the morphology of the active material is well-maintained even after extensive cycling, whereas the bare electrode undergoes severe degradation.

PVDF 중공사막을 이용한 진공 막 증류 모듈의 공급수 조건에 따른 열성능 특성에 관한 실험적 연구 (An Experimental Study on the Characteristic of Thermal Performance according to Feed Water Conditions to of Vacuum Membrane Distillation Module using PVDF Hollow Fiber)

  • 주홍진;곽희열
    • 상하수도학회지
    • /
    • 제31권4호
    • /
    • pp.339-346
    • /
    • 2017
  • In this study, thermal performance test of VMD module was performed, prior to the construction of the demonstration plant using the vacuum membrane distillation (VMD) module of the capacity of $400m^3/day$ and to the commercialization of the VMD module. For the thermal performance test, the experimental equipment of capacity of $2m^3/day$ was constructed. The permeate flux test and thermal performance test according to feed water conditions such as temperature and flow rate were conducted. The VMD module used in the study was manufactured by ECONITY Co., LTD with PVDF hollow fiber membrane. As a result, the Performance Ratio (PR) of the VMD module showed the maximum value of 0.904 under the condition of feed water temperature of $75^{\circ}C$ and flow rate of $8m^3/h$. PR value of the VMD module using PVDF hollow fiber membrane showed linearly increasing relationship with feed water temperature and flow rate. Also, The permeate flux of the VMD module was analyzed to have maximum value of 18.25 LMH and the salt rejection was 99.99%.