• 제목/요약/키워드: Thermal Box

검색결과 231건 처리시간 0.022초

태양전지모듈 고장 진단 알고리즘을 적용한 모니터링시스템 (The Monitoring System with PV Module-level Fault Diagnosis Algorithm)

  • 고석환;소정훈;황혜미;주영철;송형준;신우균;강기환;최정내;강인철
    • 한국태양에너지학회 논문집
    • /
    • 제38권3호
    • /
    • pp.21-28
    • /
    • 2018
  • The objects of PV (Photovoltaic) monitoring system is to reduce the loss of system and operation and maintenance costs. In case of PV plants with configured of centralized inverter type, only 1 PV module might be caused a large loss in the PV plant. For this reason, the monitoring technology of PV module-level that find out the location of the fault module and reduce the system losses is interested. In this paper, a fault diagnosis algorithm are proposed using thermal and electrical characteristics of PV modules under failure. In addition, the monitoring system applied with proposed algorithm was constructed. The wireless sensor using LoRa chip was designed to be able to connect with IoT device in the future. The characteristics of PV module by shading is not failure but it is treated as a temporary failure. In the monitoring system, it is possible to diagnose whether or not failure of bypass diode inside the junction box. The fault diagnosis algorithm are developed on considering a situation such as communication error of wireless sensor and empirical performance evaluation are currently conducting.

스팀-에어 레토르트의 온도분포에 미치는 공정 변수 영향 (The Effect of Various Processing Conditions on Temperature Distribution in Steam-air Retort)

  • 이선영;신해헌;인예원;조형용
    • 산업식품공학
    • /
    • 제23권2호
    • /
    • pp.87-93
    • /
    • 2019
  • 공기 주입식 스팀-에어 레토르트 내에서 스팀온도, 내부가압, CUT 등의 공정변수가 레토르트 내부의 온도 균일성에 미치는 영향을 평가하였다. 고온살균(121℃)이 저온살균(82℃) 보다 공정구간동안 온도분포가 더 균일하고 안정적이었다. 내부 가압이 클수록 저온살균조건의 공정에서는 온도분포가 안정적이었고, 이와 반대로 고온살균조건의 공정에서 온도분포가 더 불균일한 것으로 나타났다. 승온구간을 조절한 경우에는 레토르트 내의 온도분포에는 유의적인 차이를 나타내지 않았다. 공정구간동안 레토르트 내부에서 냉점은 수직방향 1층의 위로 확인되었고, 수평방향에서는 맨 뒤쪽 중앙 부분이 가장 높은 온도를 유지하여 공정 동안 이 위치들을 주의를 할 필요가 있었다. 또한 레토르트 내부의 양 옆 위치가 다른 위치에 비해 특히 온도분포가 불안정한 것으로 확인되었으므로 레토르트 가공 공정에서 주의해야 할 것으로 판단되었다.

데이터 기반 모델에 의한 강제환기식 육계사 내 기온 변화 예측 (Data-Based Model Approach to Predict Internal Air Temperature in a Mechanically-Ventilated Broiler House)

  • 최락영;채영현;이세연;박진선;홍세운
    • 한국농공학회논문집
    • /
    • 제64권5호
    • /
    • pp.27-39
    • /
    • 2022
  • The smart farm is recognized as a solution for future farmers having positive effects on the sustainability of the poultry industry. Intelligent microclimate control can be a key technology for broiler production which is extremely vulnerable to abnormal indoor air temperatures. Furthermore, better control of indoor microclimate can be achieved by accurate prediction of indoor air temperature. This study developed predictive models for internal air temperature in a mechanically-ventilated broiler house based on the data measured during three rearing periods, which were different in seasonal climate and ventilation operation. Three machine learning models and a mechanistic model based on thermal energy balance were used for the prediction. The results indicated that the all models gave good predictions for 1-minute future air temperature showing the coefficient of determination greater than 0.99 and the root-mean-square-error smaller than 0.306℃. However, for 1-hour future air temperature, only the mechanistic model showed good accuracy with the coefficient of determination of 0.934 and the root-mean-square-error of 0.841℃. Since the mechanistic model was based on the mathematical descriptions of the heat transfer processes that occurred in the broiler house, it showed better prediction performances compared to the black-box machine learning models. Therefore, it was proven to be useful for intelligent microclimate control which would be developed in future studies.

MIRIS 우주관측카메라의 기계부 개발 (DEVELOPMENT OF THE MECHANICAL STRUCTURE OF THE MIRIS SOC)

  • 문봉곤;정웅섭;차상목;이창희;박성준;이대희;육인수;박영식;박장현;남욱원;;;양순철;이선희;이승우;한원용
    • 천문학논총
    • /
    • 제24권1호
    • /
    • pp.53-64
    • /
    • 2009
  • MIRIS is the main payload of the STSAT-3 (Science and Technology Satellite 3) and the first infrared space telescope for astronomical observation in Korea. MIRIS space observation camera (SOC) covers the observation wavelength from $0.9{\mu}m$ to $2.0{\mu}m$ with a wide field of view $3.67^{\circ}\times3.67^{\circ}$. The PICNIC HgCdTe detector in a cold box is cooled down below 100K by a micro Stirling cooler of which cooling capacity is 220mW at 77K. MIRIS SOC adopts passive cooling technique to chill the telescope below 200 K by pointing to the deep space (3K). The cooling mechanism employs a radiator, a Winston cone baffle, a thermal shield, MLI (Multi Layer Insulation) of 30 layers, and GFRP (Glass Fiber Reinforced Plastic) pipe support in the system. Optomechanical analysis was made in order to estimate and compensate possible stresses from the thermal contraction of mounting parts at cryogenic temperatures. Finite Element Analysis (FEA) of mechanical structure was also conducted to ensure safety and stability in launching environments and in orbit. MIRIS SOC will mainly perform Galactic plane survey with narrow band filters (Pa $\alpha$ and Pa $\alpha$ continuum) and CIB (Cosmic Infrared Background) observation with wide band filters (I and H) driven by a cryogenic stepping motor.

Cloning된 효모의 RNAI 유전자의 특성에 관하여 (Characterization of the cloned RNA1 gene of Saccharomyces cerevisiae)

  • 송영환;김대영;김진경
    • 한국어병학회지
    • /
    • 제6권2호
    • /
    • pp.93-101
    • /
    • 1993
  • 효모의 RNAI유전자는 RNA processing에 관여 하는지 혹은 RNA transport에 관여 하는지 아직까지 유전자의 기능이 정확히 알려져 있지 않은 실정이다. 효모의 RNAI 유전자의 기능을 파악하기 위한 방법으로 본 연구에서는 rna1-1 mutant gene을 cloning하여 이에 대한 DNA sequence를 조사함으로써 RNAI 유전자와 rna1-1 유전자의 차이점을 이해하고자 하였다. rna1-1 marker를 갖는 yeast strain(R49)로 부터 genomic DNA를 추출하여 이를 BglII로 절단하여 genomic southern blotting을 행한 결과 wild type의 경우와 동일하게 3.4 kb에서 hybridization되는 signal을 얻었으며, RNAl 및 rna1-1이 yeast genome내에 single site로 존재함을 보여 주는 결과를 얻었다. mutant strain으로 부터 얻은 3.4 kb의 BglI fragment를 pUC19의 BamHI site에 subcloning하여 transformant들을 얻었고, wild type RNAl 유전자를 probe로 하여 rna1-1 mutant 유전자를 cloning할 수 있었다. pUC19에 cloning된 RNA1유전자 및 rna1-1유전자로부터 다양한 Ba131유도체를 얻어 이들에 대한 염기 서열을 비교한 결과 transcription initation site에서부터 down stream쪽으로 17 아미노산위치에 TCC가 TTC로 대치되어 있었으며 그 결과 serine이 phenylalanine으로 변환되는 결과를 얻었다. Wild type RNAI gene의 5'-region에는 3군데의 TATA-like sequence가 true TATA box인지 확인하기 위하여 Bal3I deletion에 의해 -103nt까지 deletion된 유도체를 얻었으며 ${\Delta}RNAI$, rna1-1, 81-2-6 clone이 rna1-1 allele와 complementation한지 확인하였으나 ${\Delta}RNAI$은 TS-complementation을 하지 못하였다. 따라서 현재까지 TATA-box라고 알려진 부분은 promoter로 작용하지 못함을 확인하였다.

  • PDF

The Coating Effects of Al2O3 on a Li[Li0.2Mn0.54Co0.13Ni0.13]O2 Surface Modified with (NH4)2SO4

  • Oh, Ji-Woo;Oh, Rye-Gyeong;Hong, Jung-Eui;Yang, Won-Geun;Ryu, Kwang-Sun
    • Bulletin of the Korean Chemical Society
    • /
    • 제35권5호
    • /
    • pp.1516-1522
    • /
    • 2014
  • A series of 20 wt % $(NH_4)_2SO_4$ and 3 wt % $Al_2O_3$ surface treatments were applied to $Li[Li_{0.2}Mn_{0.54}Co_{0.13}Ni_{0.13}]O_2$ substrates. The $Li[Li_{0.2}Mn_{0.54}Co_{0.13}Ni_{0.13}]O_2$ substrates were synthesized using a co-precipitation method. Sample (a) was left pristine and variations of the 20 wt % $(NH_4)_2SO_4$ and 3 wt % $Al_2O_3$ were applied to samples (b), (c) and (d). XRD was used to verify the space group of the samples as R$\bar{3}$m. Additional morphology and particle size data were obtained using SEM imagery. The $Al_2O_3$ coating layers of sample (b) and (d) were confirmed by TEM images and EDS mapping of the SEM images. 2032-type coin cells were fabricated in a glove box in order to investigate their electrochemical properties. The cells were charged and discharged at room temperature ($25^{\circ}C$) between 2.0V and 4.8V during the first cycle. The cells were then charged and discharged between 2.0V and 4.6V in subsequent cycles. Sample (d) exhibited lower irreversible capacity loss (ICL) in the first charge-discharge cycle as compared to sample (c). Sample (d) also had a higher discharge capacity of ~250 mAh/g during the first and second charge-discharge cycles when compared with sample (c). The rate capability of the $Al_2O_3$-coated sample (b) and (d) was lower when compared with sample (a) and (c). Sample (d), coated with $Al_2O_3$ after the surface treatment with $(NH_4)_2SO_4$, showed an improvement in cycle performance as well as an enhancement of discharge capacity. The thermal stability of sample (d) was higher than that of the sample (c) as the result of DSC.

유기섬유의 용융 및 기화에 따른 초고강도 콘크리트의 폭렬 특성 평가 (Evaluation on Spalling Properties of Ultra High Strength Concrete with Melting and Vaporization of Fiber)

  • 김규용;최경철;이주하;이승훈;이태규
    • 콘크리트학회논문집
    • /
    • 제24권2호
    • /
    • pp.173-183
    • /
    • 2012
  • 최근 고강도 콘크리트의 폭렬현상에 관한 메커니즘의 연구와 더불어 폭렬을 방지하는 방법으로써 섬유혼입에 의한 콘크리트의 수증기압을 낮추는 방법이 선호되고 있는 실정이다. 주로 단일 형태의 폴리프로필렌 섬유를 혼입하여 폭렬을 저감하는 방법들이 사용하고 있으나 초고강도 콘크리트 영역에서는 실제로 급격하게 온도가 상승하는 경우에 있어서 폭렬 및 급격한 수증기 팽창압을 고려할 수 없다는 점을 들 수 있다. 따라서 이 연구에서는 콘크리트 내부온도상승조건에 따라 섬유의 용융점에 따른 공극의 형성 및 폭렬의 상관성을 분석하고자 하였으며, W/B 12.5%의 초고강도 콘크리트를 대상으로 용융점이 다른 PE섬유, PP섬유, 나일론섬유를 각각 0.15vol%, 0.25vol% 혼입하여 폭렬 성상, 수증기압, 시차열 중량 분석, 해석적 검토를 행하였다. 실험 결과, 동일 섬유 혼입률 조건에서 섬유의 용융점이 낮더라도 초고강도 콘크리트에서는 섬유의 기화에 의한 섬유의 중량손실이 발생하지 않으면 초기 폭렬의 방지가 어렵고, 가열시간 10분 전후의 빠른 공극을 형성하는 섬유가 폭렬의 방지에 효과적인 것으로 나타났다.

응축형 복합레진 수복시 유동성 레진 이장이 변연부 미세누출에 미치는 영향 (THE EFFECT OF FLOWABLE RESIN LINING ON THE MARGINAL MICROLEAKAGE OF CONDENSABLE RESIN RESTORATION)

  • 문주훈;고근호
    • Restorative Dentistry and Endodontics
    • /
    • 제26권1호
    • /
    • pp.16-22
    • /
    • 2001
  • The purpose of this study was to evaluate the marginal microleakage of condensable composite resin restorations according to flowable resin lining of internal cavity wall. The eighty extracted human molar teeth without caries and/or restorations are used The experimental teeth were randomly assigned into four groups of ten teeth each. Eighty caries-free extracted human molars were used in this study. The conventional class II cavities (box-shaped on mesial and distal surface, faciolingual width : 3mm, gingival wall depth : 1.5mm) were prepared 1mm below cementoenamel junction with a # 701 carbide bur. The teeth were divided into four groups, and then each group were subdivided into A & B group according to flowable resin & compomer lining ; Group 1-A : Tetric Ceram filling, Group 1-B : Tetric Flow lining and Tetric Ceram filling, Group 2-A Ariston pHc filling, Group 2-B : Tetric Flow lining and Ariston pHc filing, Group 3-A SureFil filling, Group 3-B : Dyract Flow lining and SureFil filling, Group 4-A : Pyramid filling, Group 4-B : Aeliteflo lining and Pyramid filling. To simulate as closely as possible the clinical situation during retoration placement, a "restoration template" was fabricated, and the condensable resin was filled using a three-sited light-curing incremental technique. All the materials used were applied according to the manufacturers' instructions. The specimens were stored in the 100% humidity for 7 days prior to thermocycling (100 thermal cycles of 5~55$^{\circ}C$ water with a 30-second dwell time) The specimens were immersed in 2% metyleneblue dye for 24 hours, and then embedded in transparent acrylic resin and sectioned mesiodistally with diamond wheel saw. The degree of marginal leakage was scored under stereomicroscope ($\times$20) and the data were analyzed by Kruskal-Wallis test and Wilcoxon signed ranks test. The results were as follows : 1. In the gingival margins of all the group, microleakage of subgroup B was less than subgroup A. 2. In the group 1, 2, 4, there was significant differences between subgroup A and B (p<0.05), but in the group 3, there was not significant different between group 3-A (SureFil) and group 3-B (Dyract flow/SureFil) (p>0.05). 3. In the subgroup A and B, there was significant different between all group except group 4 of subgroup A. From the results above, it was suggested that the cavity lining of flowable resin and flowable compomer in condensable resin restoration decrease microleakage at gingival margin, and does improve their ability to seal the gingival margin of class II preparation.

  • PDF

조경용 차양 재료의 공극률이 하절기 옥외공간 평균복사온도에 미치는 영향 (The Influence of the Landscaping Shade Materials' Porosity on the Mean Radiant Temperature(MRT) of Summer Outdoors)

  • 이춘석;류남형
    • 한국조경학회지
    • /
    • 제45권2호
    • /
    • pp.60-67
    • /
    • 2017
  • 하절기 옥외공간에서 조경용 차양 소재의 공극률 차이에 따른 온열환경의 개선 효과를 객관적 물리량으로 검증하기 위해, 도심 건물 옥상에 조성된 암상자 상단에 공극률을 달리한 흑색 막소재의 차양을 설치하고, 그 하부의 평균복사온도의 차이를 계측하여 비교하였다. 적용된 공극률은 각각 0.5, 1. 2, 4, 8, 16, 32% 였으며, 2016년 8월에서 11월까지 세 조씩 순차적으로 비교되었다. 일 최고 흑구온도가 $30^{\circ}C$ 이상인 날의 오전 11시부터 오후 3시까지의 자료를 비교한 결과, 차양과 측벽이 설치되지 않는 개방구의 평균복사온도가 $44.26^{\circ}C$일 때, 무측벽-유차양구, 유측벽-무차양구, 유측벽-유차양구의 값은 각각 33.08, 45.80, $42.03^{\circ}C$로 차양과 측벽 유무에 의한 명확한 차이가 확인되었다. 측정 시기별 평균복사온도 기준치를 보정하기 위하여 대조구의 값을 공변량으로 공극률에 따른 값을 공분산분석(ANCOVA)한 결과, 유측벽-무차양구의 평균 값이 $45.80^{\circ}C$일 때, 0.5, 1, 2, 4, 8, 16, 32% 공극률 차양 하부의 값은 각각 43.40, 43.10, 41.49, 40.43, 39.61, 37.91, $38.12^{\circ}C$로 계산되었다. 공극률과 평균복사온도 사이에는 약 22.5%의 공극률을 최저점으로 하는 U자형의 2차 함수의 관계가 있는 것으로 분석되었다. 결론적으로, 본 연구를 통해서 차양의 공극률이 높아질수록 일정 수준까지는 평균복사온도를 저감시키는 효과가 있음을 확인할 수 있었으며, 그 한계값은 물리적 측정치로는 16%였으며, 통계적 추정치로는 약 22.5%였다.

핵융합로부품 시험을 위한 고열부하 시험시설 KoHLT-1 구축 (Development of a High Heat Load Test Facility KoHLT-1 for a Testing of Nuclear Fusion Reactor Components)

  • 배영덕;김석권;이동원;신희윤;홍봉근
    • 한국진공학회지
    • /
    • 제18권4호
    • /
    • pp.318-330
    • /
    • 2009
  • 본 한국원자력연구원에서는 국제열핵융합실험로(ITER)의 일차벽을 개발하기 위해 그라파이트 히터를 이용한 고열부하 시험시설 KoHLT-1(Korea Heat Load Test facility-1)을 구축하였으며, 현재 정상적으로 가동되고 있다. KoHLT-1의 주목적은 Be-CuCrZr-SS의 이종 금속이 HIP 방법에 의해 접합된 ITER 일차벽 mockup의 접합 건전성을 확인하는데 있다. KoHLT-1은 판형 그라파이트 히터, 냉각 jacket이 부착된 상자형 시험용기, 직류 전원, 냉각계통, He 기체 공급계통과 각종 진단계통으로 구성되어 있으며, 이 모든 시설은 Be 처리가 가능한 특수 정화계통이 설치된 실험실에 설치되었다. 그라파이트 히터는 두개의 시험 대상물 사이에 설치되며, 시험대상물과의 거리는 $2{\sim}3\;mm$이다. 시험 대상물의 크기와 요구되는 열유속에 따라 여러 가지의 그라파이트 히터를 설계, 제작하였으며, 전기 저항은 고온 운전 중에 $0.2{\sim}0.5{\Omega}$이 되도록 하였다. 히터는 100V/400 A의 직류전원에 연결되어 있으며, PC와 multi function module로 구성된 전류 조정계통에 의해 미리 프로그램되어 있는 패턴으로 전류를 자동 조절하게 된다. 두 시험대상물에 인가되는 열유속은 calorimetry법에 의해 냉각수의 입, 출구 온도와 유량을 측정하여 얻게 된다. 여러 가지 형태의 ITER 일차벽 Be mockups에 대해 고열부하 시험을 수행하였으며, 시험을 통하여 KoHLT-1 고열부하 시험 시설의 성능이 확인되었고, 24시간 이상의 연속 운전에 있어서도 그 신뢰성이 입증되었다.