• Title/Summary/Keyword: Therapeutic technique

Search Result 369, Processing Time 0.025 seconds

The design for therapeutic agents of Leucine Rich Repeat protein using bioinformatics

  • Kim, Seong Yeol;Park, Beom Seok
    • International Journal of Advanced Culture Technology
    • /
    • v.7 no.4
    • /
    • pp.156-162
    • /
    • 2019
  • Rheumatoid arthritis (RA) is a chronic autoimmune disorder characterized by progressive joint deterioration; Furthermore, RA can also affect body tissues, including the skin, eyes, lungs, heart and blood vessels. The early stages of RA can be difficult to diagnose because the signs and symptoms mimic those of many other diseases. It is not known exactly what triggers the onset of RA and how to cure the disease. But recent discoveries indicate that remission of symptoms is more likely when treatment begins early with strong medications known as disease-modifying anti-rheumatic drugs (DMARDs). Tumor necrosis factor (TNF) inhibitors are typical examples of biotherapies that have been developed for RA. The substances may occur naturally in the body or may be made in the laboratory. Other biological therapies care biological response modifiers (BRMs)such as monoclonal antibodies, interferon, interleukin-2 (IL-2) and a protein binder using repeat units. These substances play significant anti-inflammatory roles. Proteins with recurrent, conserved amino acid stretches mediate interactions among proteins for essential biological functions; for example, ankyrin (ANK), Heat repeat protein (HEAT), armadillo repeat protein (ARM) and tetratricopeptide repeats (TPR). Here, we describe Leucine rich repeats (LRR) that ideally fold together to form a solenoid protein domain and is more applicable to our current study than the previously mentioned examples. Although BRMs have limitations in terms of immunogenicity and effector functions, among other factors, in the context therapeutic use and for proteomics research, We has become clear that repeat-unit-derived binding proteins will increasingly be used in biotechnology and medicine.

Predictors of intentional intoxication using decision tree modeling analysis: a retrospective study

  • Oh, Eun Seok;Choi, Jae Hyung;Lee, Jung Won;Park, Su Yeon
    • Clinical and Experimental Emergency Medicine
    • /
    • v.5 no.4
    • /
    • pp.230-239
    • /
    • 2018
  • Objective The suicide rate in South Korea is very high and is expected to increase in coming years. Intoxication is the most common suicide attempt method as well as one of the common reason for presenting to an emergency medical center. We used decision tree modeling analysis to identify predictors of risk for suicide by intentional intoxication. Methods A single-center, retrospective study was conducted at our hospital using a 4-year registry of the institute from January 1, 2013 to December 31, 2016. Demographic factors, such as sex, age, intentionality, therapeutic adherence, alcohol consumption, smoking status, physical disease, cancer, psychiatric disease, and toxicological factors, such as type of intoxicant and poisoning severity score were collected. Candidate risk factors based on the decision tree were used to select variables for multiple logistic regression analysis. Results In total, 4,023 patients with intoxication were enrolled as study participants, with 2,247 (55.9%) identified as cases of intentional intoxication. Reported annual percentages of intentional intoxication among patients were 628/937 (67.0%), 608/1,082 (56.2%), 536/1,017 (52.7), 475/987 (48.1%) from 2013 to 2016. Significant predictors identified based on decision tree analysis were alcohol consumption, old age, psychiatric disease, smoking, and male sex; those identified based on multiple regression analysis were alcohol consumption, smoking, male sex, psychiatric disease, old age, poor therapeutic adherence, and physical disease. Conclusion We identified important predictors of suicide risk by intentional intoxication. A specific and realistic approach to analysis using the decision tree modeling technique is an effective method to determine those groups at risk of suicide by intentional intoxication.

Recent Research Trends of Acupuncture for Wrinkle Treatment (주름 개선을 위한 침 연구의 현황분석)

  • Jung, Hyeon-Suk;Kim, Tae-Jun;Park, Ji-Yeun
    • Korean Journal of Acupuncture
    • /
    • v.38 no.2
    • /
    • pp.62-74
    • /
    • 2021
  • Objectives : The aim of this study is to analyze the effect of acupuncture and the details of acupuncture treatment methods on skin wrinkles. Methods : Search was conducted in Pubmed, KISS, and NDSL databases for acupuncture studies on skin wrinkles. The detailed therapeutic techniques of acupuncture used for skin wrinkles and the effect of acupuncture on skin wrinkle improvement were analyzed. Then, the study results using the same indicator were compared through meta-analysis in order to compare the effects of acupuncture with the control group. The quality of randomized controlled trials (RCTs) was assessed using the risk of bias (ROB) assessment tool (Ver. 1.0, Cochrane Collaboration). Results : A total of 10 RCTs and 19 case series were included in this study. The most frequently used therapeutic technique for skin wrinkle improvement was Microneedle therapy system (MTS, n=19), and they were mostly used with aesthetic solutions (13 out of 19 studies). Skin wrinkle related indexes were most commonly used to evaluate skin wrinkle improvement (n=14). Panax Ginseng pharmacopuncture showed the most remarkable effect in improving the range of skin wrinkles and the depth of skin wrinkles. MTS+epidermal growth factor improved the levels of skin hydration, skin elasticity, and variation of skin pigment the most. MTS+Endothelial precursor cell improved the number of skin melanin the most. Three RCTs included in the meta-analysis showed moderate ROB on average. Conclusions : Acupuncture treatment was effective in improving skin wrinkles. However, a precise study design using unified indicators and appropriate controls needs to be performed in further studies in order to establish more convincing evidence of the effectiveness of acupuncture for improving skin wrinkles.

Comparative Phytochemical Profiling of Methanolic Extracts of Different Parts of White Dandelion (Taraxacum coreanum) using Hybrid Ion-mobility Q-TOF MS

  • Hyemi Jang;Mira Choi;Eunmi Lee;Kyoung-Soon Jang
    • Mass Spectrometry Letters
    • /
    • v.15 no.2
    • /
    • pp.95-106
    • /
    • 2024
  • Taraxacum coreanum, known as the native Korean white dandelion, has been historically used in traditional medicine due to its various therapeutic properties. However, the specific benefits and mechanisms of white dandelion in alleviating particular symptoms or diseases remain uncertain due to the complexity of its phytochemical profile. In this study, we aimed to elucidate the phytochemical profiles of methanolic extracts of different parts of the white dandelion (flower, leaf, stem, and root) using hybrid ion-mobility Q-TOF MS. Using the trapped ion mobility-based PASEF technique, 3715 and 2114 molecular features with MS2 fragments were obtained in positive and negative ion modes, respectively, and then a total of 360 and 156 phytochemical compounds were annotated by matching with a reference spectral library in positive and negative ion modes, respectively. Subsequent feature-based molecular networking analysis revealed the phytochemical differences across the four different parts of the white dandelion. Our findings indicated that the methanolic extracts contained various bioactive compounds, including lipids, flavonoids, phenolic acids, and sesquiterpenes. In particular, lipids such as linoleic acids, lysophosphatidylcholines, and sesquiterpenoids were predominantly present in the leaf, while flavonoid glycosides and lysophosphoethanolamines were notably enriched in the flower. An assessment of the total phenolic content (TPC) and total flavonoid content (TFC) of the methanolic extracts revealed that the majority of phytochemicals were concentrated in the flower. Interestingly, despite the root extract displaying the lowest TPC and TFC values, it exhibited the highest radical scavenging rate when normalized to TPC and TFC, suggesting a potent antioxidant effect. These findings and further investigations into the biological activities and medicinal potential of the identified compounds, particularly those exclusive to specific plant parts, may contribute to the development of novel therapeutic agents derived from white dandelion.

Utilization of Tissue Compensator for Uniform Dose Distribution in Total Body Irradiation (전신방사선조사시 균등한 선량분포를 이루기 위한 조직보상체의 이용)

  • Park, Seung-Jin;Chung, Woong-Ki;Ahn, Sung-Ja;Nam, Taek-Keun;Nah, Byung-Sik
    • Radiation Oncology Journal
    • /
    • v.12 no.2
    • /
    • pp.233-241
    • /
    • 1994
  • Purpose : This study was performed to verify dose distribution with the tissue compensator which is used for uniform dose distribution in total body irradiation(TBI). Materials and methods : The compensators were made of lead(0.8mm thickness) and aluminum(1mm or 5mm thickness) plates. The humanoid phantom of adult size was made of paraffin as a real treatment position for bilateral total body technique. The humanoid phantom was set at 360cm of source-axis distance(SAD) and irradiated with geographical field size(FS) $144{\times}144cm^2(40{\times}40cm^2$ at SAD 100cm) which covered the entire phantom. Irradiation was done with 10MV X-ray(CLINAC 1800, Varian Co., USA) of linear accelerator set at Department of Therapeutic Radiology, Chonnam University Hospital. The midline absorbed dose was checked at the various regions such as head, mouth, mid-neck, sternal notch, mid-mediastinum, xiphoid, umbilicus, pelvis, knee and ankle with or without compensator, respectively. We used exposure/exposure rate meter(model 192, Capintec Inc., USA) with ionization chamber(PR 05) for dosimetry, For the dosimetry of thorax region TLD rods of $1x1x6mm^3$ in volume(LiF, Harshaw Co., Netherland) was used at the commercially available humanoid phantom. Results : The absorbed dose of each point without tissue compensator revealed significant difference(from $-11.8\%\;to\;21.1\%$) compared with the umbilicus dose which is a dose prescription point in TBI. The absorbed dose without compensator at sternal notch including shoulder was $11.8\%$ less than the dose of umbilicus. With lead compensator the absorbed doses ranged from $+1.3\%\;to\;-5.3\%$ except mid-neck which revealed over-compensation($-7.9\%$). In case of aluminum compensator the absorbed doses were measured with less difference(from $-2.6{\%}\;to\;5.3\%$) compared with umbilicus dose. Conclusion : Both of lead and aluminum compensators applied to the skull or lower leg revealed a good compensation effect. It was recognized that boost irradiation or choosing reference point of dose prescription at sternal notch according to the lateral thickness of patient in TBI should be considered.

  • PDF

The error analysis of field size variation in pelvis region by using immobilization device (고정기구의 사용이 골반부위 방사선조사영역의 변화에 미치는 오차분석)

  • Kim, Ki-Hwan;Kang, No-Hyun;Bim, Dong-Wuk;Kim, Jun-Sang;Jang, Ji-Young;Kim, Yong-Eun;Kim, Jae-Sung;Cho, Moon-June
    • Journal of Radiation Protection and Research
    • /
    • v.25 no.1
    • /
    • pp.31-36
    • /
    • 2000
  • In radiotherapy, it may happen to radiate surrounding normal tissue because of inconsistent field size by changing patient position during treatment. We are going to analyze errors reduced by using immobilization device with Electonic portal imaging device(EPID) in this study. We had treated the twenty-one patients in pelvic region with 10 MV X-ray from Aug. 1998 to Aug. 1999 at Chungnam National University Hospital. All patients were treated at supine position during treatment. They were separated to two groups, 11 patients without device and 10 patients with immobilization device. We used styrofoam for immobilization device and measured the errors of anterior direction for x, y axis and lateral direction for z, y axis from simulation film to EPID image using matching technique. For no immobilization device group, the mean deviation values of x axis and y axis are 0.19 mm. 0.48 mm, respectively and the standard deviations of systematic deviation are 2.38 mm, 2.19 mm, respectively and of random deviation for x axis and y axis are 1.92 mm. 1.29 mm, respectively. The mean deviation values of z axis and y axis are -3.61 mm. 2.07 mm, respectively and the standard deviations of systematic deviation are 3.20 mm, 2.29 mm, respectively and of random deviation for z axis and y axis are 2.73 mm. 1.62 mm, respectively. For immobilization device group, the mean deviation values of x axis and y axis are 0.71 mm. -1.07 mm, respectively and the standard deviations of systematic deviation are 1.80 mm, 2.26 mm, respectively and of random deviation for x axis and y axis are 1.56 mm. 1.27 mm, respectively. The mean deviation values of z axis and y axis are -1.76 mm. 1.08 mm, respectively and the standard deviations of systematic deviation are 1.87 mm, 2.83 mm, respectively and of random deviation for x axis and y axis are 1.68 mm, 1.65 mm, respectively. Because of reducing random and systematic error using immobilization device, we had obtained good reproducibility of patient setup during treatment so that we recommend the use of immobilization device in pelvic region of radiation treatment.

  • PDF

Postoperative Radiation Therapy in the Soft-tissue Sarcoma (연부 조직 육종의 수술 후 방사선 치료 결과)

  • Kim Yeon Shil;Jang Hong Seok;Yoon Sei Chul;Ryu Mi Ryeong;Kay Chul Seung;Chung Su Mi;Kim Hoon Kyo;Kang Yong Koo
    • Radiation Oncology Journal
    • /
    • v.16 no.4
    • /
    • pp.485-495
    • /
    • 1998
  • Purpose : The major goal of the therapy in the soft tissue sarcoma is to control both local and distant tumor. However, the technique of obtaining local control has changed significantly over the past few decades from more aggressive surgery to combined therapy including conservative surgery and radiation and/or chemotherapy. We retrospectively analyzed the treatment results of the postoperative radiation therapy of soft tissue sarcoma and its prognostic factor. Materials and Methods : Between March 1983 and June 1994, 50 patients with soft tissue sarcoma were treated with surgery and postoperative radiation therapy at Kang-Nam St. Mary's hospital. Complete follow up was possible for all patients with median follow up duration 50 months (range 6-162 months). There were 28 male and 32 female patients. Their age ranged from 6 to 83 with a median of 44 years. Extremity (58$\%$) was the most frequent site of occurrence followed by trunk (20$\%$) and head and neck (12$\%$). Histologically malignant fibrous histiocytoma (23$\%$), liposarcoma (17$\%$), malignant schwannoma (12$\%$) constitute 52$\%$ of the patients. Daily radiation therapy designed to treat all areas at a risk for tumor spread upto dose of 4500-5000 cGy. A shrinking field technique was then used and total 55-65 Gy was delivered to tumor bed. Twenty-five patients (42$\%$) received chemotherapy with various regimen in the postoperative period. Results : Total 41 patients failed either with local recurrence or with distant metastasis. There were 29 patients (48$\%$) of local recurrence. Four patients (7$\%$) developed simultaneous local recurrence and distant metastasis and 8 patients (13$\%$) developed only distant metastasis. Local recurrence rate was rather higher than of other reported series. This study included patients of gross residual, recurrent cases after previous operation, trunk and head and neck Primary This feature is likely explanation for the decreased local control rate. Five of 29 Patients who failed only locally were salvaged by re-excision and/or re-irradiation and remained free of disease. Factors affecting local control include histologic type, grade, stage, extent of operation and surgical margin involvement, lymph node metastasis (p<0.05). All 21 patients who failed distantly are dead with progressive disease at the time of this report. Our overall survival results are similar to those of larger series. Actuarial 5 year overall survival and disease free survival were 60.4 $\%$, 30.6$\%$ respectively. Grade, stage (being close association with grade), residual disease (negative margin, microscopic, gross) were significant as a predictor of survival in our series (p<0.05). Conclusion : Combined surgery and postoperative radiation therapy obtained 5 year survival rate comparable to that of radical surgery.

  • PDF

The evaluation of dose of TSEI with TLD and diode dector of the uterine cervix cancer (열형광선량계와 반도체검출기를 이용한 전신피부전자선조사의 선량평가)

  • Je Young Wan;Na Keyung Su;Yoon IL Kyu;Park Heung Deuk
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.17 no.1
    • /
    • pp.57-71
    • /
    • 2005
  • Purpose : To evaluate radiation dose and accuracy with TLD and diode detector when treat total skin with electron beam. Materials and Methods : Using Stanford Technique, we treated patient with Mycosis Fungoides. 6 MeV electron beam of LINAC was used and the SSD was 300 cm. Also, acrylic speller(0.8 cm) was used. The patient position was 6 types and the gantry angle was 64, 90 and $116^{\circ}$. The patient's skin dose and the output were detected 5 to 6 times with TLD and diode. Result : The deviations of dose detected with TLD from tumor dose were CA $+\;6\%$, thigh $+\;8\%$, umbilicus $+\;4\%$, calf $-\;8\%$, vertex $-\;74.4\%$, deep axillae $-\;10.2\%$, anus and testis $-\;87\%$, sole $-\;86\%$ and nails shielded with 4mm lead $+4\%$. The deviations of dose detected with diode were $-4.5\%{\sim}+5\%$ at the patient center and $-1.1\%{\sim}+1\%$ at the speller. Conclusion : The deviation of total skin dose was $+\;8\%{\sim}-\;8\%$ and that deviation was within the acceptable range(${\pm}\;10\%$). The boost dose was irradiated for the low dose areas(vertex, anus, sole). The electron beam output detected at the sootier was stable. It is thought that the deviation of dose at patient center detected with diode was induced by detection point and patient position.

  • PDF

Dose Characteristics of Stereotactic Radiosurgery in High Energy Linear Accelerator Proton Beam (고에너지 선형가속기에 의한 입체방사선수술의 선량특성)

  • Choi, Tae-Jin;Kim, Ok-Bae
    • Radiation Oncology Journal
    • /
    • v.10 no.2
    • /
    • pp.137-145
    • /
    • 1992
  • Three-dimensional dose calculations based on CT images are fundamental to stereotactic radiosurgery for small intracranial tumor. In our stereotactic radiosurgery program, irradiations have been performed using the 6 MV photon beam of linear accelerator after stereotactic CT investigations of the target center through the beam's-eye view and the coordinates of BRW frame converted to that of radiosurgery. Also we can describe the tumor diameter and the shape in three dimensional configuration. Non-coplanar irradiation technique was developed that it consists of a combination of a moving field with a gantry angle of $140^{\circ}$, and a horizontal couch angle of $200^{\circ}C$ around the isocenter. In this radiosurgery technique, we provide the patient head setup in the base-ring holder and rotate around body axis. The total gantry moving range shows angle of 2520 degrees via two different types of gantry movement in a plane perpendicular to the axis of patient. The 3-D isodose curves overlapped to the tumor contours in screen and analytic dose profiles in calculation area were provided to calculate the thickness of $80\%$ of tumor center dose to $20\%$ of that. Furtheremore we provided the 3-D dose profiles in entire calculation plane. In this experiments, measured isodose curves in phantom irradiation have shown very similiar to that of computer generations.

  • PDF

Studies on Veterinary Acupuncture in Korea (한국 수의침술에 관한 조사연구)

  • Nam Tchi-Chou;Jo Choong-Ho;Choi Hee-In;Sung Jai-Ki;Kweon Oh-Kyeong
    • Journal of Veterinary Clinics
    • /
    • v.9 no.1
    • /
    • pp.283-299
    • /
    • 1992
  • Since successive operations under the acupuncture analgesia have been reported In China 1971, veterinary acupuncture was brought to the attention over the world and then its research and clinical use have markedly developed. Veterinary acupuncture and moxibustion was originated in China and Korea, but the research activities on them were not very significantly advanced. In this study, status of veterinarians on veterinary acupuncture and moxibustion, acupunctures which has been practiced by civil acupuncturist, therapeutic effects of acupuncture for the animal diseases in the field, and effects of electric acupuncture on the lumen motility in ruminants, etc. were Investigated. One-fifty of veterinarians of private clinics in Korea was interested in acupuncture and moxibustion in veterinary medicine. A lot of veterinarians required the scientific, systemic technique and knowledge or acupuncture. Civil acupuncturists who have been practiced acupuncture and moxibustion were 20 persons, and most of them were very old. They used chiefly three edged needles which were made by themselves and utilized old traditional technique in which the acupoints were stimulated and bled. Treatment with acupuncture for the digestive, muscular locomotive and febrile diseases was very effective. Until nowadays, the research on veterinary acupuncture in Korea has not much progressed. However, the Korean Societh of Veterinary Acupuncture and Moxibustion was organized in 1990. Valuable development for acupuncture through the society are expected. Electroacupuncture regional analgesia on the combinations of Yao-Pang 1, 2 and 4 acupoints was very effective for abdominal operations in cattle. But a lot of experiences and studies on the acupuncture anesthesia were required for clinical use in the future. Therapeutic effects of about 80% were obtained from electroacupuncture on the combinations of Tian Ping-Bai Hui-Shi Zhang, and Guan Yuan Yu acupoints in cattle with luminal atony and tympany In the field. Electroacupuncture on the combination of Tian Ping-Bai Hui-Qi Men, and Tian Ping-Bai Bui-Wei Gen for the treatment of downer cow was not so effective. The effects of stimulation and bleeding from acupoint by three edged needle was excellent for febrile diseases. The luminal contractile movement was accentuated by electroacupuncture on Tian Ping-Bai Hui-Shi Zhang combination and Guan Yuan Yu acupoint. It was concluded that veterinary acupuncture and moxibustion should be utilized for veterinary practice, and the advanced scientific research and clinical experiences must be followed.

  • PDF